HomeMy WebLinkAboutCOR-2009-Open Joists - Hello TJ, Thanks for the information. After reviewing ESR 1035 it very clearly states in item 5.7" Evaluation of the use of Open Joist 2000 trusses as a component of fire resistive-rated roof or floor assemblies is outside the scope of this report".This is also stated in the letter dated Dec 3, 2009; the report only deals with the structural properties of the joists. However,the information provided indicates WHI certification as a 1 Hr, FR assembly consistent with ASTM—E119, also consistent with the 2006 IBC. In the past the architect has provided the WHI listing and assembly detail. The other item is sound transmission, IBC Section 1207.2 requires an STC rating of not less than 50 and an IIC rating of not less than 50. While it appears there may have been sound testing I am not able to find that information. In short, it appears the Fire Rating, with a WHI Listing, works, however the sound transmission ratings are not shown and we will need to confirm that the ratings are consistent with the 2006 IBC. Please note the architect of record will need to sign off on this as well. Thanks, Don Measamer City of Anacortes Assistant Director, Planning& Community Development, Building Official Don@cityofanacortes.org Phone 360.293.1901 Fax 360.293.1938 From:TJ Mellema [mailto:t m@exxelpacific.com] Sent Thursday, December 03, 2009 12:12 PM To: don@CityofAnacortes.org Cc: Casey Dixon Subject: Open Joists 2000 for Chandler's Square Don, Please see attached documentation regarding the fire rating for the Open Joists 2000 that we are planning to use on the Chandler's Square Project. Please review the information and give me a call with any questions. If you have technical questions regarding the testing please feel free to contant Glen Walker at the number below. I appreciate you looking into this. Please let me know as soon as possible if this is approved. Thanks, T.J. Mellema Exxel Pacific, Inc 360-734-2872 360-815-3940 From: G Walker [mailto:gwalker@e-buildingsystems.com] Sent: Thursday, December 03, 2009 11:44 AM To: Grant Buchanan; q@exxelpacific.com; David Routt; ependland@sbcglobal.net; jporostosky@e-buildingsystems.com Subject: Importance: High Glen Walker Engineered Building Systems (EBS) P.O. Box 2391 Prescott, AZ 86302 480-323-6670 (Cell) gwalker@e-buildingsystems.com www.e-buildingUstems.com OPEN JOIST o Distribution Open Joist 2000 Inc. 1970 rue Des Toitures, Ste-Marthe-du-Cap(QC) G8V 1V9 O Tel. (800)567-8644 Fax(819)374-4527 0 www.openjoist2000.com 1600 PI Socrate,Brossard (Quebec)J4X 1M2 334 Cornelia St. Suite 338,Plattsburgh,NY 12901 Tel. (800)263-7265 Fax(514)990-0078 Reengineering Wood Components To Whom It May Concern: Dec 3 2009 Please find the attached: 1)The ES Report(ICC Evaluation Services Inc. www.icc-es.org)ESR-1035 This is legacy a report that conforms with 2006 IBC,2006 IRC, 1999 BNBC, 1999 SBC and 1997 UBC specific to the Open Joist 2000 product and is now in accordance and recognized by the ICC. This legacy report deals with the structural properties only of and for Open Joist 2000. This report has had re-examination by ICC and waiting for ICC to re-issue the report,but is still valid. 2)ITS Directory of Listed Products Listing Open Joist 2000 is tested by the ICC accredited third party testing agency of Intertek Testing Services(Inchcape,WHI, ITS)for fire and sound and is tested in accordance with the following standards and bears the mark of WHI Certification: ASTM-E 119 i CAN/ULC-S 101 NFPA-251 UBC-7-1 (formerly 43-1) UL-263 UL or Underwriters Laboratories was not engaged to perform theses tests although Open Joist 2000 has been tested in accordance to the above listed assemblies of UL. Please don't hesitate to contact me at the phone or email below with any further questions. Regards, Glen Walker 480-323-6670 gwalker@e-buildingsystems.com Peace of mind underfoot- ESR-1035 , REPORTT'"S Reissued February 1, 2007 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. Business/Regional Office■5360 Worlamn Mill Road,Whittier,California 90601 ■(562)699-0543 Regional Office■900 Montclair Road,Suite A,Birmingham,Alabama 35213 ■(205)599-98W WWW.ICc-@S.ora Regional Office■4051 West Flossmoor Road,Country Club Hills,Illinois 60478■(708)799-2305 DIVISION: 06—WOOD AND PLASTIC 2.0 USES Section:06170—Prefabricated Structural Wood The Open Joist 2000 parallel chord trusses are used as REPORT HOLDER: structural repetitive members in roof or floor assemblies. 3.0 DESCRIPTION DISTRIBUTION OPEN JOIST 2000 INC. 3.1 General: 1970 RUE DES TOITURES TROIS-RIVIERES, QUEBEC G8V 1V9 The Open Joist 2000 is a parallel chord truss, consisting of CANADA solid-sawn lumber top and bottom chords and diagonal and (800)263-7265 vertical web members. Chord members are continuous and www.openioist2000.com are fabricated with finger-joints located along the joist. The mike(cDopenioist2000.com minimum distance between chord finger-joints is 24 inches (610 mm). Web members are continuous, with no finger- EVALUATION SUBJECT: joints. Each end of the web member is finger-joined into the top and bottom chords and glued with a resorcinol adhesive. OPEN JOIST 2000—ENGINEERED WOOD PRODUCT Chord and web dimensions and grade are dependent upon joist depth, span and design loads. Open Joist 2000 trusses are manufactured to depths of 93/" 117/" 13, 14 and 16 ADDITIONAL LISTEES: inches(238, 301,330,356 and 406 mm).See Figures 1 and 2 for configuration details. UNIVERSAL FOREST PRODUCTS(305)INC. ROAD Open Joist 2000 trusses are fabricated by Open Joist 2000 16783 THORNDALE R THORN DALE, ONTAR 2P0 Inc. or by one of the additional listees specified in this ADA evaluation report. Grade-stamped lumber used to fabricate CAN CAN 461-1180 the trusses is reinspected at the manufacturing plant prior to its use.The moisture content is verified and individual lumber www.ufpi.com pieces are machined to pattern and redried to a moisture UNIVERSAL FOREST PRODUCTS(273)INC. content of less than 16 percent. 3778 ONEIDA VALLEY ROAD 3.2 Materials: EMLENTON, PENNSYLVANIA 16373 3.2.1 Chord Members:Top and bottom chords are made of (724) 867-1100 nominally 2-by-3 or 2-by-4, visually graded spruce-pine-fir www.ufpi.com (SPF), No. 2 or better, or machine-stress-rated (MSR) SPF 2100f-1.8E or MSR SPF 2400f-2.OE. UNIVERSAL FOREST PRODUCTS(310) INC. 3.2.2 Diagonal Web Members:Diagonal webs are made of 68956 U.S. HIGHWAY 131 nominally 2-by-2, 2-by-3 or 2-by-4 visually graded lumber in WHITE PIGEON, MICHIGAN 49099 accordance with the approved quality control manual. (269)483-2222 www.ufpi.com 3.2.3 Vertical Web Members: Both ends of the truss are manufactured with solid vertical web members made of 1.0 EVALUATION SCOPE nominally 2-by-8 SPF, No. 2 or better, or a laminated wood panel manufactured from SPF solid-sawn lumber meeting the Compliance with the following codes: requirements specified in the approved quality control manual 2006 International Code" for the fabrication of Open Joist 2000 trusses. ■ 3.2.4 Adhesive: The adhesive used to fabricate the Open ■ 2006 International Residential Code®(IRC) Joist 2000 trusses is two-component modified resorcinol ■ BOCA®National Building Code/1999(BNBC) formaldehyde, complying with ANSI/AHC A190.1-, CSA 0112.7-M, and ASTM D 2559. ■ 1999 Standard Building Code®(SBC) 4.0 DESIGN AND INSTALLATION ■ 1997 Uniform Building CodeTm (UBC) 4.1 Design: Properties evaluated: The Open Joist 2000 trusses shall be designed to resist loading requirements as specified in the tables shown in this Structural report. Details for rim joists, bridging and blocking at the joist REPORTS" are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by/CC Evaluation Service,Inc.,express or implied,as to any fending or other matter in this report,or as to any product covered by the report. a) .. e.q.. niaouercannraoe Copyright©2007 Page 1 of 10 Page 2 of 10 ESR-1035 ends, to prevent roll-over and to transfer lateral and vertical published installation instructions. Manufacturer's loads, shall be provided in accordance with the design recommendations relating to rim joists, bridging or drawings and calculations submitted to the building official. blocking that are not within the scope of this report shall Tables 1,2,3,4 and 5 of this report provide design live load be verified by engineering analysis. tables for truss depths of 93/" 117/" 13, 14 or 16 inches(238, 5.2 Design calculations, drawings, and details for specific 301, 330, 356 or 406 mm), respectively. The tables are applications,demonstrating compliance with this report, applicable only to uniformly loaded, simple-span joists, shall be submitted to the code official.The calculations, installed as repetitive members in floor or roof assemblies, drawings and details shall be prepared by a registered where minimum 5/8 inch-thick(15.9 mm)sheathing is attached design professional where required by the statutes of to the top flanges in accordance with the applicable code.The the jurisdiction in which the project is to be constructed. repetitive member factor, C,equals 1.0 when the Open Joist Design shall be in accordance with Tables 1 through 5 2000 trusses are installed in accordance with this report. of this report and the applicable code. 4.2 Installation: 5.3 Damaged or defective joists shall not be used. Open Joist 2000 trusses shall be delivered to the jobsite with 5.4 Conditions of use for Open Joist 2000 trusses shall be an assembly plan and a set of installation instructions covered,dry conditions of use.Dry conditions of use are published by the manufacturer. those conditions of use represented by sawn lumber in Open Joist 2000 trusses are permitted to be used only as which the moisture content is less than 19 percent. repetitive members in a roof or floor assembly.To comply as 5.5 Cutting or notching of any member of the joist is a repetitive member, the trusses shall be installed in an prohibited, except that up to 51/2 inches (140 mm) is assembly of repetitive trusses, spaced not more than 24 permitted to be removed from each end of the joist inches(610 mm), not less than three in number, and joined (closed end). by minimum 5/,-inch-thick (15.9 mm) sheathing attached to the top flanges in accordance with the applicable code. 5.6 Fire-retardant-treated or preservative-treated wood shall Required bearing length shall be the longer of the bearing not be used in the manufacture of these products. length calculated based on the bearing capacity of the 5.7 Evaluation of the use of Open Joist 2000 trusses as a supports or 1.5 inches(38 mm).The ends of the joist member component of fire-resistance-rated roof or floor are permitted to be field-cut(closed end)to the desired length assemblies is outside the scope of this report. to a maximum adjustment of 51/2 inches (140 mm) at each 5.8 Joists are produced by Open Joist 2000 Inc. or one of end. the additional listees specified in this report, under a Maximum bearing permitted is such that the inside face of quality control program with inspections by Intertek the bearing does not extend beyond 11 inches(279 mm)into Testing Services, NA, Inc. the span from the end of an uncut joist,or beyond 51/2 inches 6.0 EVIDENCE SUBMITTED (140 mm)into the span from the end of a joist that has its end cut the maximum amount. 6.1 Installation instructions. Manufacturer's recommendations relating to rim joists, 6.2 Data in accordance with the ICC-ES Acceptance bridging, blocking, and other framing details, that are not Criteria for Prefabricated Parallel Chord Wood Trusses within the scope of this report,shall be verified by engineering (AC224), dated October 2005. analysis. 6.3 Quality control manuals. 5.0 CONDITIONS OF USE 7.0 IDENTIFICATION The Open Joist 2000 trusses described in this report comply with,or are suitable alternatives to what is specified in,those The Open Joist 2000 shall be identified with a stamp noting codes listed in Section 1.0 of this report, subject to the the name or logo of the report holder(Distribution Open Joist following conditions: 2000 Inc.) or one of the additional listees specified in this report,and the plant location or identifier;the product name; 5.1 The trusses are installed in accordance with this report the production date; the name of the inspection agency and the manufacturer's published installation (IntertekTesting Services,NA,Inc.);and the evaluation report instructions. The provisions of this report shall govern number(ESR-1035). should there be any conflict with the manufacturer's Page 3 of 10 ESR-1035 OPM JOWT W TABLE 1 -ALLOWABLE LIVE LOAD( PSF) FOR OPEN JOIST 2000(')(4) TABLE1a AL=L/360 At=L/240") JOIST DEPTH:9319" DEAD LOAD-19 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACMG ec SPACNG o.c. SPACMG ex. SPACNG ac. M3x SPE S L ' 24' 12" 16" 19,2' 4" 6` 92" 4" 12- B" 192" 4" SPF#2 11'-01 183 134 109 84 178 129 104 79 173 124 99 74 168 119 94 69 SPF 02 12'-0' 147 110 92 73 t47 110 90 60 147 107 86 63 t46 102 00 58 SPF 13V 115 86 ?2 58 115 86 72 58 115 86 72 115 86 70 50 SPF#2 14-0' 94 71 59 47 94 71 59 Q 94 71 59 45 94 71 58 40 SPF#2 15'-0' 77 58 48 38 77 58 48 1 38 77 58 1 48 1 37 77 56 48 32 3 x 2 I SPF N2 161-0" 64 46 40 32 64 48 40 32 64 48 40 31 64 48 40 26 4 x 2 SPF 44 17-0' 70 53 44 35 70 44 35 7 53 44 31 70 53 40 26 4 x 1 1. 1 ' " 4 x 2 SPF 210041.0E 19'-0" 61 46 38 30 61 46 38 30 61 46 37 25 61 44 32 20 4 x 2 SPF 210%1 ft 20'-0" 53 40 33 3i 53 40 33 26 53 33 23 53 40 30 18 TABLE1b AL=L/480 At=L/240(3) JOIST DEPTH:9 3f8" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 �CNORDS --" MYINUF SPACING ox- SPACMG o.c. SPACMG o.c. SPACING O.C. SIZE 9 S! E MGM 12' 16' 92" 4' " 19 ' 24" 12" 16" 1 2" 4" 12' " 1 2" 24" 3 x 2 SPF#2 11. 139 104 87 70 [770 104 87 70 139 104 87 70 139 104 87 69 3 x 2 SPF#2 12' 110 83 69 55 83 69 56 110 83 f39 65 110 83 69 55 3 x 2 SPF#2 1310, 86 65 54 43 65 64 43 86 65 64 43 136 66 64 43 3 x 2 SPF#2 14'-0' 70 53 44 35 53 44 35 70 53 44 35 70 534 x F#2 15-0' 78 69 39 4 99 49 39 49 39 4 x 2 SPF 02 16'-0' 66 49 41 33 49 41 33 66 49 41 33 66 49 41 32 4 x 2 SPF 210041.8E 17'-0' 66 49 41 33 49 41 66 49 41 33 66 49 41 30 4x2 SPF210041.8E 18-0" 64 41 34 27 4t 34264 41 34 27 64 4t 34 26 4 x2 SPF 210041.8E 19'-0' 46 35 29 23 35 29 23 46 35 29 23 46 35 29 20 4 x 2 5PF2100418E 20-0' 40 30 25 20 30 25 20 40 30 25 20 40 30 25 18 (1)Table is based on the assumption multiple foists(repetdive members)are installed in a floor or roof system with minimum5/&nch sheathing attached to the top flanges. No increase in allowable load for repelitrve member use or durabon of load allowed. (2)Allowable load values in the table shall be reduced if repaid"member conddionS are not met(20 percent for 3x2 and 13 percent far 4x2) (3)Loads noted in the table are linsted by live load deflection( 4 L)and total load deflection(A 1) (4)"Manufactured length'refers to overall length which includes the possibiNy of a 1Q.inch bearing on both ends.To compute the allowable'clear span"substract 11 inches from the tabulated manufactured length. (5)Siconversions 1inch=25.4mm 1foot=304>3min 1psf=479Ntn2 Page 4 of 10 ESR-1035 OM Jow TABLE 2-ALLOWABLE LIVE LOAD( PSF)FOR OPEN JOIST 2000(1)(4) TABLE2a AL=L/360 At= L/240(3) JOIST DEPTH:11 718" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACING ax. SPACING ox- SPACING ox. SPACING ox SPECIES/GRADEEN 12" 16' 4" 12' ' 1 ' 24" 16* 24" 6' 1 24' x 3x2 SPF AR 11=0- 212 155 127 99 207 150 122 94 202 j71 117 89 197 140 112 84 3x2 SPF#2 12�0' 188 137 112 87 183 132 107 82 188 102 77 173 122 97 72 3 x 2 SPF Al2 t 3=0' 1fa4 119 97 75 159 111 92 70 154 87 65 149 104 82 60 3 x 2 SPF 012 14=0' 145 105 85 65 140 100 80 60 135 75 55 130 90 70 50 04x2 SPF Al2 15, 120 90 75 57 120 89 70 52 119 66 47 114 78 60 42 SPF AQ 16,0' 102 77 64 49 102 76 60 44 102 55 39 98 66 500 34 SPF A4 17'0' Be 66 55 43 88 66 52 3e W 61 47 33 86 55 42 28 1 41 1 82 54 40 26 SPF 44 19'-0' 84 59 47 35 037 74 49 37 25 69 " 32 20 SPF 2100(-1.8E 20'Do 93 70 58 43 --Er92 63 48 33 97 58 43 28 SPF 2100f-1.8E 21'-0" 78 59 49 39 78 55 42 29 77 50 37 24 SPF2f0061.8E 22=0' 67 50 42 34 67 49 37 25 67 44 32 20 SPF 2100f-1.lI 23=0' 59 44 37 M Sg 4q 35 23 59 42 30 18 TABLE2b AL=L/480 At= L/240(3) JOIST DEPTH:1171811 DEAD LOAD-15 DEAD LOAD-20 OF-AD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACING ex. SPACING ox- SPACING o.c. SPACING ax- S E SP CI S/ BADE LENGTH 12" 16" 192" 24' 12" 16" 19 4" 12' 116" 1 - 4" 12' 16" 19 " 24" 98 3x2 SPF A4 11'-0' 212 155 1 127 1 99 207 160 1 122 1 94 202 146 1 117 1 89 197 140 1 112 1 84 3x2 SPF A4 1210• 179 134 112 1 87 179 132 107 i 82 178 127 102 77 173 122 97 1 72 3x2 SPF 02 13=0• 1 141 106 88 70 1 141 106 88 70 1,11 106 87 65 141 104 82 60 3x2 SPF 42 14'0' 115 86 72 58 1 115 86 72 58 1 115 86 72 55 115 86 70 50 3x20SPF2100f.I.BE SPF 42 15'-0' 90 67 56 45 90 67 56 45 90 67 56 45 90 67 56 42 3 z2 1610' 77 58 48 38 17 58 48 38 77 58 48 38 77 59 48 34 3 x 2 1710' 66 49 41 33 66 49 41 33 66 49 41 33 66 49 41 20 4 x 18'0' 78 49 78 69 45 31 40 26 4 x 2 19,0• 67 50 42 34 67 50 42 30 67 49 37 25 67 44 32 20 4 x 2 IIE 2010' 70 53 44 35 70 53 44 35 70 63 44 33 70 53 43 28 4 x 2 1.HE 21'.0' 59 44 37 30 59 " 37 30 59 44 37 29 59 44 37 24 4 x 2 1.8E 22=0' 51 38 32 26 51 33 32 26 51 38 32 25 51 38 32 2D 4.2 SPF 2100f-1.8E 23=0' 45 34 28 22 45 34 28 22 45 34 28 22 45 34 28 18 (I)Table is based on the assumption multiple joists(repetitive members)are installed in a floor or roof system with minimum 5,ew nch sheathing attached Io the top flanges No increase in allowable load for repetitive member use or duration of load allowed. (2),111lowable load values in Me table shall be reduced drepentive member conditions are not met(20 percont for 3x2 and 13 percent for dx2) (3)Loads noted in the table are limited by live load deflection( A L)and total load deflection(A t) (4)'Manufactured length'refers to overall length which includes the possibility of a 51l2-inch bearing on both ends.To compute the allowable clear span'substract 11 inches from the tabulated manufactured length (5)8lconversions linch=25,4nm Ilbot=3040mm Ipsf-470N1m2 Page 5 of 10 ESR-1035 OM roar &erTABLE 3-ALLOWABLE LIVE LOAD( PSF )FOR OPEN JOIST 2000" t4) TABLE 3a d L= L/360 s t= L/240(3) JOIST DEPTH:13" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACING o-c. SPACING ox. SPACING o a SPACING ex. S E d /GRAD L. GTH 12" 16" 2" 24" 12" 16" 192" 2" 16* 9 ' 24' 12" 16" 192" 24" 3 x2 SPF Al2 14'-0' 24i 177 145 113 236 172 140 108 231 167 135 103 226 162 130 98 3 x2 SPF Art 120-W 212 156 127 99 207 150 122 94 202 145 117 89 197 140 112 84 3 x2 SPF#2 13'-0' 188 137 112 87 183 132 107 82 178 127 102 77 173 122 97 72 3 x 2 SPF Art 14'-D" 169 123 100 77 164 118 95 72 159 113 90 67 154 108 85 62 3 x2 SPF#2 16-V 150 109 88 67 145 104 83 62 140 99 78 57 135 94 73 52 3 x2 SPF#2 16'-0' 128 93 75 57 124 88 70 52 119 83 65 47 114 78 60 42 3 x 2 SPF 42 17'-0' 1D6 79 65 49 106 76 60 44 103 71 55 39 96 66 50 34 3 x 2 SPF#2 18'-0' 91 68 57 43 91 66 52 38 90 M 85 56 42 28 4 x2 SPF A4 1TV 102 73 58 43 97 58 53 38 92 87 58 43 28 4 x 2 SPF A2 20'.0' 91 64 51 38 86 59 46 33 87 76 49 36 23 4 x 2 SPF#2 21'-0' 80 59 47 35 79 54 4230 71 69 44 32 20 4 x 2 SPF2100f-1.8E 22'-0' 83 62 52 39 83 62 48 34 83 79 52 38 24 4 x 2 SPF 2100f-1,8E 23'A' 74 55 46 36 74 55 44 31 74 72 47 34 21 4 x 2 SPF 210061.8E 24'-0' 64 48 40 32 64 48 40 28 64 6442 30 18 4 x 2SPF 2IM-1 8E 25'•0' 58 43 36 29 58 43 36 26 58 38 27 16 TABLE M A L= L/480 e t= L/240 131 JOIST DEPTH:13" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACING o.c. SPACING et. SPACING o.c, SPACING ex. SQE SPEdE /GRADE LENGTH 12" 16" 192" 24" 12" 18' 192" 24" 12" 16' 19.2' 24" 12' 16" 192' 24' 5FF AIR 4rm 273 201 1 165 1 129 268 1 196 1 169 1 124 263 1191 4 3 x2 SPF 42 11'-0' 241 177 145 1 113 236 172 140 1 108 231 167 135 103 226 162 130 98 3 x2 SPF#2 12'-0' 212 155 127 99 207 150 122 94 202 145 /17 89 197 140 112 84 3 x2 SPF AQ 13'-0' 171 128 107 86 171 128 107 82 171 127 102 77 171 122 97 72 3 x2 SPF AR 14%0' 142 107 89 71 142 107 89 71 142 107 89 67 142 107 85 62 3 x2 SPF A4 15'-0' 114 85 71 57 114 85 71 57 114 85 71 5T 114 85 71 52 3 x2 SPF#2 16'-0' 96 72 60 48 96 72 60 46 96 72 60 47 96 72 60 42 3 x 2 SPF Art 17'-0' 80 W 50 40 80 60 50 40 80 60 50 39 80 60 50 34 3 x2 SPF#2 181-0' 69 52 43 34 69 52 43 34 69 52 43 33 69 52 42 28 1 x2 S #2 t ,-w 80 60 50 40 80 6D 43 28 4 x2 SPF 02 20'-0' 69 52 43 34 69 52 43 33 69 52 41 28 69 49 36 23 4 x 2 SPF 210041 8E 21'-0' 72 54 45 36 72 54 45 36 72 54 45 33 72 54 43 28 4 x 2 SPF 2100f-1.BE 22'-0' 64 48 40 32 64 48 40 32 64 48 40 29 64 48 38 24 4 x 2 SPF 21M-1 8E 23'-0' 56 42 35 28 56 42 35 28 56 42 35 26 56 42 34 21 4 x2 SPF2l0Ul-1.8E 24'-0' 48 36 30 24 48 36 30 24 48 36 30 23 48 36 30 18 4 x 2 SPF 21 •1.8E 25'-0- 43 32 27 22 43 32 27 43 32 2T 21 43 32 27 16 (1)Table is based on the assumption munipie joists(repebtive members)are installed in a floor or roof system with rrimmum 5B-inch sheathing attached to the top flanges No increase in allowable bad for repetitive member use or duration of load allowed. (2)Allowable load values in the table shall be reduced if repeltive member conditions are not met(20 percent for 3x2 artd 13 percent fpr 4x2) (3)Loads noted in the table are limited by We load deflection( e L)and total load deflection(At) (4)'Manufactured length'refers to overall length which includes the passibility of a 5 112-inch bearing on both ends To compute the allowable"clear span"substract 11 inches from the tabulated manufactured length (5)Sl conversions.I inch=25,4mm I foot=304,8mm Ipsf=47,9N/mit Page 6 of 10 ESR-1035 Or= JOW &4re TABLE 4-ALLOWABLE LIVE LOAD(PSF )FOR OPEN JOIST 2000")(4) TABLE 4a A L=L/360 A t= L/240(3) JOIST DEPTH:14" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS 19ANUF SPACNG o.a SPACING o . SPACING o c. SPACNIG o.c. S 4' 16" 191, 24, 1 x 3 x2 SPF 42 11'-0' 241 177 145 1 113 236 172 140 108 231 167 135 103 226 162 130 96 3 x2 SPF AQ 12'-0" 212 I55 127 99 207 150 122 94 202 146 117 9- 197 140 112 84 3 x2 SPF#2 1TV 188 137 112 87 183 132 1D7 82 178 127 102 77 173 122 97 72 3 x 2 SPF 44 14'-0' 169 123 100 77 164 118 95 72 159 113 90 67 154 108 85 62 3 x2 SPF tr2 75'-0' 150 109 08 67 145 101 83 51 140 99 78 57 135 94 73 52 3.2 SPF AQ 16'-0' 128 93 75 57 124 88 70 62 119 83 66 47 114 78 60 42 3 x2 SPF AQ 17'-0' 106 79 65 1 49 106 76 60 44 103 71 55 39 98 1 66 50 34 3 x 2 SPF AQ 16'-01 91 68 57 1 43 91 66 52 1 38 90 61 1 47 1 33 86 56 42 28 4x2 SPF A4 19'-0' 102 73 58 1 43 97 68 53 38 92 63 18 33 87 58 43 28 4 x 2 SPF 49 20'-0' 91 64 51 38 86 59 46 33 81 54 41 28 76 49 36 23 4 x 2 SPF 02 21'-0' 80 59 47 35 79 54 42 30 74 49 37 25 69 N 32 20 4 x 2 SP mot.1.eE 22'-0" 83 62 52 39 03 62 48 34 83 57 43 29 79 52 38 24 1 x2 SPF 2f0pF1.8E 74 55 46 36 74 55 44 31 74 52 39 26 72 47 34 21 4 x 2 SPF 210Df•1.8E 2d'-0' 64 48 40 32 64 48 40 28 64 47 36 23 64 42 30 18 d x ?i •1.8 25'-0 5 43 36 43 36 26 —Sr 4 32 21 3e 27 16 TABLE U A L=L/480 A t= L/240(3) JOIST DEPTH:14" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACING e.c SPACING a c. SPACING o c. SPACING ox- SIZE S/GRADLENGTH 12" 16" 192" 24" 12" 16" 192" 24" 12" 16" 19 4" 12" 16* 192" 24" x 3 x2 SPF 82 111-0' 241 177 145 113 236 172 140 1 108 231 167 135 103 226 162 130 1 98 3 x 2 SPF 42 12'-0" 212 155 127 99 207 150 122 94 202 145 117 89 197 140 112 84 3 x 2 SPF 412 13'-0" 171 128 107 f 171 123 107 62 171 127 102 77 171 122 97 72 3 x2 SPF 44 id'-0' 142 107 89 71 142 107 89 71 142 107 t39 67 142 107 85 62 3 x2 SPF A2 15'4" 114 85 71 57 114 85 71 57 114 86 71 57 114 85 71 52 3 x 2 SPF AQ /6'-0' 96 72 60 48 96 72 60 48 96 72 6D 47 % 72 60 42 3 x2 SPF 42 17'-0' 00 60 50 40 90 60 50 40 8D 60 50 39 80 60 50 34 3 x 2 SPF 42 16'-0" 69 52 43 34 89 52 43 34 69 52 43 33 68 52 1 42 2e 4 x 2 SPF 412 19 so 60 1 So 1 40 60 80 GO 1 33 00 55 43 4x2 SPF A2 ary 69 52 43 34 69 52 43 33 69 52 41 28 69 49 36 23 4 x 2 SPF 2100f-1.8E 21'-0" 72 54 45 36 72 54 45 36 72 54 45 33 72 54 43 28 4x2 SPF2100f•1.8E 274P 64 48 40 32 64 48 40 32 64 48 40 29 fi4 48 38 24 4 x 2 SPF 2100f-12E 23'-0' 56 42 35 28 56 42 35 28 56 42 35 2C, 56 42 34 21 4x2 SPF2100f•1,8E 24'-0" 46 36 30 24 48 36 30 24 46 36 30 23 40 36 30 18 4 x 2 8PF 210X-1.8E 25'-0" 43 32 27 22 43 32 27 22 43 32 27 21 43 32 27 16 (1)Table is based on the assumption multiple joists(repetitive members)are installed in a floor or roof system with rrinimum 5A1•inch sheathing attached lathe lop flanges. No increase in allowable bad for repetili re member use or duration of load allowed. (2)Allowable load values in theta"shall be reduced S repelAne member conditions are not met(20 percent for 3x2 and 13 percent for 4x2) (3)Loads noted in the table are limited by Ive load deflection( a L)and total load deflection(All (4)*Manufactured length'refers to overall length which includes the possibility of a 5 1Q•inch bearing on both ends To compute the allowable'clear span'subsbact 11 inches from the tabulated manufactured length. (5)Slcomersions:1 nch=25,4 mm 1 foot=304,8mm 1 psf=47.9N/m2 Page 7 of 10 ESR-1035 orals roar oo° TABLE 5-ALLOWABLE LIVE LOAD ( PSF)FOR OPEN JOIST 2000(1)(4) TABLE5a AL=L/360 At= L/240) JOIST DEPTH:16" DEAD LOAD-15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD-30 CHORDS MANUF SPACING oc. SPACNGo.c. SPACNGo.c. SPACING ox- SIZESPECIES/GRADE LENGTH 12" 16" 192" 24" 12" 16" 192" 24" 12" 16" 192" 24" 12" 16" 19.2" 24" 3 x 2 SPF#2 10'-0" 201 207 170 133 276 202 165 128 271 197 460 1 33 266 192 155 118 3 x2 SPF#2 11'-0" 241 177 145 113 236 172 140 108 231 167 135 103 226 162 130 98 3 x2 SPF#2 12'0" 212 155 127 99 207 550 122 94 202 145 117 89 197 140 112 84 3 x2 SPF#2 13'-0" 188 137 112 87 183 132 107 82 178 127 102 77 173 122 97 72 3 x2 SPF#2 14'0' 169 123 100 77 164 118 95 72 159 113 90 67 154 108 85 62 3 x 2 SPF#2 15,0" 153 Ill 90 69 148 106 85 64 143 101 80 59 138 % 75 54 3 x2 SPF#2 16,a" 145 105 85 65 140 100 80 60 135 95 75 55 130 90 70 50 3 x 2 I SPF 4112 17'-0" 142 1 103 83 63 137 1 98 1 78 58 132 93 73 53 127 1 88 66 48 4x2 SPF#2 18'-0" 169 123 100 77 164 118 95 1 72 159 1 113 1 90 67 154 108 85 62 4x2 SPF 42 19'-0" 161 117 95 73 1 156 112 90 66 151 107 85 63 146 102 80 58 4x2 SPF#2 20'-0" 154 112 91 70 1 149 107 86 65 144 102 81 60 1 139 97 76 55 4x2 SPF#2 21'0" 148 107 87 67 143 102 82 62 138 97 77 57 133 92 1 72 52 4x2 SPF#2 22'0" 137 99 80 61 1 132 94 75 56 127 09 70 51 122 84 65 46 4 x 2 SPF 2100E 1.8E 23'0" 127 91 74 56 122 86 69 51 1 77 81 64 46 112 76 59 41 4x2 SPF 2100f-1.8E 24'0" 104 78 65 52 102 76 64 47 94 70 59 42 86 64 54 37 4x2 SPF2100f1.8E 25'-0" 96 1 72 60 47 92 1 6958 1 42 84 63 53 37 76 57 48 32 4 x 2 SPF 2100f 1.8E 26'-0" 83 62 52 42 81 61 51 37 It 73 55 1 46 32 65 49 41 27 4 x 2 SPF 240%2.0E 27'-0" 83 62 52 42 81 61 51 1 37 73 55 46 1 32 65 49 41 27 4x2 SPF2400f-2.0E 28=0" 75 56 47 38 im 46 34 65 49 41 29 60 45 38 24 � 4 x 2 SPF 2400f-2.0E 29'0" 64 48 40 32 40 32 64 48 40 27 56 42 35 22 774 x 2 SPF 2400f-2.0E 30'0" 56 42 35 28 35 28 56 42 35 23 48 36 30 1 B TABLE 5b A L=L 1480 A t=L/240 9) JOIST DEPTH:16" DEAD LOAD=15 DEAD LOAD-20 DEAD LOAD-25 DEAD LOAD=30 CHORDS MANUF SPACING oz. SPACING o.c. SPACING o.c. SPACING oz. SIZE SPECIES/GRADE LENGTH 12" 16" 192" Zd" 12" 16" 192" 24' 12" 16" 192" 24" 12" 16" 191" 24" 3 x2 SPF#2 10'-0" 281 207 1 170 133 276 202 165 128 271 197 160 133 266 192 155 118 3 x2 SPF 42 111•0" 241 177 145 113 236 172 140 108 231 167 135 103 226 162 130 98 3 x2 SPF#2 12'0" 212 155 127 99 207 150 122 94 202 145 117 89 197 140 112 84 3 x2 SPF#2 13'0" 188 137 112 87 183 132 107 82 178 127 102 77 173 122 97 72 3 x2 SPF#2 14'0" 169 123 100 77 164 118 95 72 159 113 90 67 154 108 85 62 3 x2 SPF#2 15,0" 153 Ill 90 69 148 106 85 64 143 101 80 59 136 96 75 54 3 x2 SPF#2 16'0" 145 105 85 65 140 100 80 60 135 % 75 55 130 90 70 50 3 x2 SPF 42 17'-0" 142 103 83 63 137 98 78 58 132 93 73 53 127 88 68 48 4x2 SPF#2 18'0" 169 123 100 77 164 110 95 72 169 113 90 67 154 100 85 62 4x2 SPF#2 1910" 144 108 90 73 144 106 90 66 139 103 85 63 134 98 80 58 4 x2 SPF#2 20'-0" 128 96 80 64 128 96 80 64 128 96 80 60 123 91 75 55 4x2 SPF 42 21'-0" 112 84 70 56 112 84 70 56 112 84 70 56 112 84 70 52 4 x 2 SPF 42 22'-0" 88 66 55 44 88 66 55 44 88 66 55 44 88 66 55 44 4 x 2 SPF 2100f-1-8E 23'0" 80 60 50 40 80 60 50 40 80 60 50 40 80 60 50 40 4x2 SPF2100f1.8E 24'0" 75 56 47 38 t36 38 75 56 4T 38 75 56 47 37 4 x 2 SPF 2100E 1.8E 25'-0" 70 52 44 35 35 70 52 44 35 70 52 44 32 4 x 2 SPF 2100E 1.8E 26'0" 64 48 40 32 32 64 48 40 32 64 48 40 27 j 4x2 SPF2400f2.0E 2T-0" 60 45 38 30 30 60 45 38 30 60 d5 38 27 4 x 2 SPF 2400f-2-OE 26=0" 54 40 34 27 27 54 40 34 27 54 40 34 24 4 x 2 SPF 2400f-2.0E 29'0' 48 36 30 24 24 48 36 30 24 48 6 30 224 x2 SPF2400f2.DE 30'•0" 41 3126 21 21 41 31 26 21 41 31 26 18 (1)Table is based on the assumption multiple joisls(repetitive members)are installed in a floor or roof system with minimum 5/8-inch sheathing attached to the top flanges. No increase in allowable load for repetitive member use or duration of load allowed. (2)Allowable load values in the table shall be reduced f repetitive member conditions are not met(20 percent for3x2 and 13 percent for 4x2) (3)Loads noted in the table are limited by live load deflection( A L)and total load deflection(A I) (4)"Manufactured length"refers to overall length which includes the possibility of a 5 10-inch bearing on both ends.To compute the allowable"dear span"substract 11 inches from the tabulated manufactured length. (5)Sl conversions:I inch=25,4mm I foot=3048mm 1psf=47PN/m2 Page 8 of 10 ESR-1035 T 00 10, q y I I I r' i � I � n � I M N " M rt � M 00 I N w N \ M / N N N Y � .r i N N N Go! N � pp f M N U O�1 I N N / N r r i / N ry {p W N N / •+ M N � MI N N N ry q O rn a � n O � O� EC T O I FIGURE 1—TYPICAL TRUSSES Page 9 of 10 ESR-1035 b i " TYPE 'A" 'YPE "B" f 0 L_1 � a � �' i S3Q 125 l.253a.1250 1 ,7 0.6P530.125 ^ a c6..0E25 '�T;- �.5E-Sta^500 i--59-39i • L JIM f0mm TYPE "B" TYPE "`° TYPE "C"' i II �1 �� �J u FINGER JOINT DETAILS ales:aoeu —__---j at� MODEL. 9 318" OPEN JO1S'r h 0 SECTION "X" SECTION DATE 15/04J96 FIGURE 2—TYPICAL TRUSS DETAILS o� ^ w*^�mo � l ' | * | / . - ------ ! - -- — - ) ---------------- —'l Pvoc- T' ` ! ~J�---T--------- .|�----- -� --' �- ^ " _,. "� � . ` . -oaum 5 � / | | | � ,*m*m . �' /" | opnN —'-' .�~�e', ' | FIGURE o--TYPn:AL TRUSS DETAILS K:onunueu OPEN JOIST ® Distribution Open Joist 2000 Inc. O 1970, Route St-Maurice Nord Ste-Marthe-du-Cap O (Quebec,Canada)G8V 1V9 O E-mail address:oj2000@openjoist2000.com Phone:(819)374-8784 Fax:(819)374-45274527 Fire Endurance 1 2 3 •,. a i i 4 7 5 6 U480, 60 minutes (#OJ/FCA 60-02) 1-Topping: Topping is optional can be lightweight or proprietary topping. 2-Sub flooring: 5/8"tongue and groove plywood or oriented strandboard (OSB). 3-Structural members: Open Joist 2000®,from a minimum depth of 9 1/4"to a maximum depth of 16", installed up to 24"on center, maximum load design according to manufacturer U480 load tables, with structural graded 3x2 or 4x2 chords per NLGA grading rules for Canadian Lumber or graded by an inspection bureau or agency approved by the United States Department of Commerce Board of Review of the American Lumber Standards Committee with chord sizes of 3x2 or 4x2. Structural members should bear the WHI certification mark. 4- Bridging: Continuous 2x4 lumber nailed to the bottom chord and the sides of the diagonals with 3" long nails. 5- Resilient channel: (Optional -for acoustic performance only) Rigid steel furring channels(inverted hat-type)spaced 16"on center and attached to the bottom chord by means of 2 Type W screws. Channels overlap on 10" at the end and are attached to each other by a 1'/" Type S screw. 6-Gypsum board: 1 layer of 5/8"Type X. Long edges located between joists perpendicular to the resilient channels. Short edges are staggered by 4 feet. Sheets are fastened to the resilient channels by means of 1'/2"Type S screw located 11/"away from the long edges. Screws are spaced 6" on center. Joints are taped and finished with 2 layers of compound. 7- Insulation: Insulation material is optional for acoustic and/or thermal protection. Results obtained have been performed by Inchcape Testing Services NA Ltd-Wamock Hersey and are in accordance with ASTM E-119,CAN/ULC S-101 and UL-263. Reengineering Wood Components