BLD-2010-0064 - FIRE ALARM
1005302-2 0013 02/23/2010 001 1 -A, © Permit Fees 007752 $646.02 G _ City of Anacortes Permit#: BLD-2010-0064 904 6th Street Issue date: 02/19/2010 � �s. P.O.Box 547 02,' Anacortes, WA 98221-0547 Expire date: 08/18/2011 (360) 293-1901 z:. Job Address: 1300 0 AVE Permit Type: Fire Alarm Permit ANACORTES WA 98221-2187 Project: APN: P55246 Remarks: Fully functional new addressable fire alarm systme in both the existing facility and the new addition. Owner: ANACORTES SENIOR HOUSING LLC Contractor: COMMERCIAL FIRE PROTECTION INC Address: 816 NE 87TH AVE Address: PO BOX 128 VANCOUVER WA 98664-1991 MOUNT VERNON WA 98273-0128 Phone: Phone: (360)848-9093 License#: COMMEFP132MM General Information: Fees: Building Valuation 33130 Plan Review Fee 252.72 Building Permit Fee 388.80 State Building Code Fee 4.50 Total Calculated: 646.02 Deposits/Receipts: 0.00 Total Due: 646.02 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. f, i SIGNATURE OF OWNEII OR RIZED AGENT ISSUED rage i or Measamer, Don From: Pete Kovach [Director@chandlersquare.com] Sent: Tuesday, February 09, 2010 3:39 PM To: 'Chad Houtz'; 'Measamer, Don'; 'Harju, Dan' Cc: 'Mark Christ'; tjm@exxelpacific.com Subject: RE: Fire Alarm Plans Review comments All, FYI—when the new building opens we intend to increase staffing from one to two NOC shift Caregivers(11:OOPM— 7:OOAM). It is hoped that this will enhance in-house response time for fire and other emergencies. It has been my experience that our in-house ability to respond in timely fashion and to direct/assist with any required evacuation are and will be effective in the event of a genuine emergency. In contrast,the risks associated with a (potentially unnecessary) unassisted evacuation by 80, 90 and 100+YO residents attempting to negotiate stairs or venture outside in inclement weather preclude this as a realistic option. As such, I hope to extend the existing"shelter in place" policy to the new building. -Pete Pete Kovach Director Chandler's Square Retirement Community Director@ChandlerSquare.com (360)293-1300 From: Chad Houtz [mailto:Chad@cfirepro.com] Sent: Tuesday, February 09, 2010 3:15 PM To: Measamer, Don; Harju, Dan Cc: Pete Kovach; Mark Christ; tjm@exxelpacific.com Subject: Fire Alarm Plans Review comments Gentleman, As per Dan Harju's suggestion I'm outlining my design criteria as it relates to the cities red line comments in their preliminary review of the fire alarm system project at Chandler Square (comments dated 2/5/10) 1 —Three Annunciator Locations. One is placed as per my verbal conversation with Dan Harju on 3/8/09. This one is placed for the fire dept response to North wing emergencies in stair well #100. (1 understand first response for the rest of the facility will be and always has been the main FACP in Lobby 291 on the 2"d floor). The other two annunciators are voluntary new additions to the system to better help nursing staff respond to emergencies. This is in line with the intent of WAC 212-12-035. 2 - No smoke detectors are shown in the facility trash rooms currently. Smoke detectors can be added to these locations though there is a very relevant concern for false alarming due to air particulates in such places. This poses two issues, unduly requiring fire department resources to investigate nuisance alarms, and the considerable impact of evacuating so many residents with special care needs. 3—Area of Rescue Assistance is shown as two systems: the existing system—no change, and the new system. At this time no method seems plausible to tie the two systems together. New ADA codes require different equipment than what is installed in the existing system so we can't use phone handsets and merely extend the existing system. Upgrading the existing system is very cost prohibitive, especially considering the facilities extensive upgrades of other life safety systems that are being,proposed. Also the value of such an upgrade is negligible since the facility is already upgrading the emergency call system. This system will provide wireless pendants to each resident which greatly exceeds the functionality of any fixed AOR station in case of emergency. These are the criteria for the basis of my design, at least as it relates to the redline comments. As always we are fully willing to cooperate with the City's direction, knowing everyone's bottom line is life safety. Thanks for your time in considering these things. WI 1/1)Ol n rage /- of Regards, Chad Houtz Commercial Alarm & Detection 360-848-1533 ext.106 360-848-1072 Fax chad@cfirepro.com Yes, Looks good. Chad it will be ready to pick up today. Don Measamer City of Anacortes Assistant Director, Planning& Community Development, Building Official Don@cityofanacortes.org Phone 360.293.1901 Fax 360.293.1938 From: Harju, Dan Sent: Friday, February 19, 2010 7:38 AM To: 'Chad Houtz'; Harju, Dan Cc: Measamer, Don Subject: RE: Fire Alarm Plans Review comments I'm sorry. I thought I had sent back that reply. Does the pendant system meet the ADA requirements? That is a Don Measamer call I believe. believe everything else looks okay to me, with the understanding that the intent of the two new annunciators are for staff utilization purposes, and the north wing will have one in the east stairwell for fire use. Dan Harju Assistant Chief Anacortes Fire (360) 293-1932 From: Chad Houtz [mailto:Chad@cfirepro.com] Sent: Thursday, February 18, 2010 4:31 PM To: Harju, Dan Cc: Measamer, Don Subject: FW: Fire Alarm Plans Review comments Dan, I'm under a lot of pressure to meet a cover inspection for the new portion of this building and I still don't have a permit. Are you waiting on me for anything else? Thanks, Chad Houtz Commercial Alarm & Detection 360-848-1533 ext.106 360-848-1072 Fax chad@cfirepro.com From: Chad Houtz Sent: Tuesday, February 09, 2010 3:15 PM To: 'Measamer, Don'; 'Harju, Dan' Cc: 'Pete Kovach'; 'Mark Christ'; 'lm@exxelpacific.com' Subject: Fire Alarm Plans Review comments Gentleman, As per Dan Harju's suggestion I'm outlining my design criteria as it relates to the cities red line comments in their preliminary review of the fire alarm system project at Chandler Square (comments dated 2/5/10) 1 —Three Annunciator Locations. One is placed as per my verbal conversation with Dan Harju on 3/8/09. This one is placed for the fire dept response to North wing emergencies in stair well #100. (1 understand first response for the rest of the facility will be and always has been the main FACP in Lobby 291 on the 2"d floor). The other two annunciators are voluntary new additions to the system to better help nursing staff respond to emergencies. This is in line with the intent of WAC 212-12-035. 2 - No smoke detectors are shown in the facility trash rooms currently. Smoke detectors can be added to these locations though there is a very relevant concern for false alarming due to air particulates in such places. This poses two issues, unduly requiring fire department resources to investigate nuisance alarms, and the considerable impact of evacuating so many residents with special care needs. 3—Area of Rescue Assistance is shown as two systems: the existing system—no change, and the new system. At this time no method seems plausible to tie the two systems together. New ADA codes require different equipment than what is installed in the existing system so we can't use phone handsets and merely extend the existing system. Upgrading the existing system is very cost prohibitive, especially considering the facilities extensive upgrades of other life safety systems that are being proposed. Also the value of such an upgrade is negligible since the facility is already upgrading the emergency call system. This system will provide wireless pendants to each resident which greatly exceeds the functionality of any fixed AOR station in case of emergency. These are the criteria for the basis of my design, at least as it relates to the redline comments. As always we are fully willing to cooperate with the City's direction, knowing everyone's bottom line is life safety. Thanks for your time in considering these things. Regards, Chad Houtz Commercial Alarm & Detection 360-848-1533 ext.106 360-848-1072 Fax chad@cfirepro.com l 1 CHANDLER SQUARE ANACORTES, WA MATERIAL SUBMITTAL PREPARED BY: COMMERCIAL ALARM &DETECTION, INC. PO BOX 128 MOUNT VERNON, WA 98273 360-848-1533 CONTACT: CHAD HOUTZ CHANDLER SQUARE MATERIAL SUBMITTAL INDEX '# FIRE ALARM SYSTEM A. SILENT KNIGHT CONTROL PANEL 5820XL B. SILENT KNIGHT REMOTE ANNUNCIATOR 5860 C. SILENT KNIGHT POWER MODULE 5496 D. FIRE ALARM PULL STATION E. SILENT KNIGHT SMOKE SENSORS F. SILENT KNIGHT MONITOR G. SILENT KNIGHT RELAY H. HORN STROBES I. MINI-HORNS INTELLIKNIGHT FIRE ALARM CONTROL PANEL t $a IntelliKnight° Model 5820XL h,I' ti Addressable Fire Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, Call 203-484-7161. Description �'� •i �r 5820XL is an intelligent addressable fire alarm control panel(FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander,5824 3 serial/parallel printer interface module(for printing system reports), and 5895XL intelligent power module. 5820XL supports Hochiki or SK devices. 5820XL also features a powerful built-in dual line fire M communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 127 Hochiki devices or 99 SK detectors and 99 SK modules, expandable to 508 Hochiki devices or 396 SK detectors and 396 SK modules. • Uses standard wire no shielded or twisted pair required • Built-in digital communicator • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® • FlexputTM 1/0 circuits • Supports Class B(Style 4)and Class A(Style 6)configuration for SLC, Model 5820XL SBUS, and Flexput circuits • Distributed, intelligent power Installation • Drift compensation The 5820XL can be surface or flush mounted • 13 pre-programmed output cadences(including ANSI-3.41)and 4 programmable outputs Compatibility • Built-in annunciator with The 5820XL SLC supports multiple device 80-character LCD display types of the same protocol: • RS-485 bus provides communication to system accessories Hochiki • Built-in RS-232 and USB interface for programming via PC SK • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC • Improvements in SKSS software deliver five times faster You cannot mix Hochiki and SK devices on a uploads/downloads FACP. However, any combination of • Two built-in Form C programmable relays rated at 2.5 amps at 27.4 addressable devices of the same protocol can VDC. be used on the 5820XL. • Supports sounder bases • 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) • Programmable date setting for Daylight Saving Time • Plex-1 door option combines a dead front cabinet door with a clear SILENT window, limiting access to the panel while providing single button KNIGHT operation of the reset and silence functions 0" by Honeywell INTELLIKNIGHT FIRE ALARM • •• PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights Flexput circuits on 5820XL control can required to start a new system.The General Alarm (Red): Flashes when in be individually programmed to function built-in keypad and 5860 remote alarm; solid when alarm silenced as notification circuits, auxiliary power annunciator give on-site access to all outputs,or initiation circuits that programming.You can also program Supervisory(Yellow): Flashes when a support both 2-and 4-wire smoke remotely using the 5660 Silent Knight supervisory condition exists; solid when detectors. Software Suite,which is Windows®- supervisory silenced The 5820XL system operates on non- based software. System Troubles(Yellow): Flashes twisted, unshielded cable when wired when a trouble condition exists; solid in compliance with standard wiring when trouble silenced practices as called out in the National Built-In Digital Communicator Electric Code 760-51 specifications for 5820XL features a built-in UL listed System Silenced (Yellow): On when an power-limited fire protective signalling digital communicator for remote alarm,trouble or supervisory condition cables. No special wiring is required. reporting of system activity and system has been silenced but not yet cleared 5820XL provides 13 preset notification programming.The communicator has System Power(Green): Flashes for AC cadence patterns(including ANSI 3.41) the ability to seize two telephone lines failure; solid when power systems are and four user programmable selections to report alarms and troubles to a normal for fire alarm notification. monitoring facility.The communicator Two programmable general purpose supervises two phone lines and will System Application Form C relay outputs are provided on activate a trouble signal if a line failure is sustained for more than 45 seconds. 5820XL.5820XL has one built-in signalling line circuit(SLC)which supports 127 Additionally,the IntelliKnight system Other communication features include: retry if communication fails, two phone devices.Three additional loops can be features a built-in walk test and auto- number capability, download phone added using the 5815XL SLC programming. Its innovative, dead-front number capability and Touch-Tone or expanders to increase overall capacity cabinet design allows for flush or rotary dialing.The communicator is to 508 devices. surface mounting. System maintenance compatible with SIA and Ademco The 5820XL SLC loops support is easy to perform. Contact ID.The format is selectable by multiple device types, including: User Interface account number. • Addressable photoelectric smoke The 5820XL built-in annunciator with detector 80 character LCD display and large • Addressable ionization smoke easy-to-use tactile touchpad can be detector used for system operation, • Addressable heat sensor programming and maintenance. It has five LEDs for alarm, supervisory, • Addressable duct smoke detector system trouble, system silenced and • Contact module system power. System operations • Relay output module include silencing alarms and troubles, resetting alarms and the display of • Addressable notification module alarm troubles and memory.The The following advanced sensor system's non-volatile event history capabilities are available with 5820XL: buffer stores 1000 events for viewing from the built-in or remote annunciator. • Automatic drift compensation System operation can be initiated with Approvals • Maintenance alert a mechanical firefighter's key or a valid NFPA 13, NFPA 15, NFPA 16, 4-to 7-digit operator's code. NFPA 72: Central Station; Remote • Built-in sensor test to comply with Signalling; Local Protective Signalling NFPA 72 calibration testing Programming Systems;Auxiliary Protected Premises requirements The IntelliKnight system offers several Unit; &Water Deluge Releasing 5820XL features a 6 am options to simplify and speed u Service. Suitable for automatic, p power supply p p fY p p sprinkler and maximum battery charging programming.The JumpStarl®feature manual, waterflow, s P capacity of 35 amp hours.An additional minimizes programming supervisory(DACT non-coded) cabinet enclosure(PN RBB)is required signalling services. for batteries in excess of 18 amp hours. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol.VI; FM Approved IINTELL]KNIGHT FIRE ALARM CONTROLPANEL B IntelliKnight Model 5820XL = . Addressable Fire Alarm Control Panel Intel[ Knight 5820XL Addressable Fire Alamn System 6b-a.9l.se gtaW xaa�j MnwpwaK 9sxs<aro M14kf`la1�Ra'Bfvw4 '� tC%-?�2 11' 3$0� '9/Y� pa3urnan sduex �'S7QI��v: Kay"ss➢.xxi.«r� UF�ri'WWrA[ 5C9hll Nlixyn ?.3•Wire C.'NxNj1 t SYxa 4 ,af.a f+rWlr+'aaVwYfMa�21. ...... 5515%i. tq scalrsar..�r sic r Ina+aw 0 [ 4 � n G f ��.��s�, Gr�?e.4tFw.x.rrnma.aw;d lti(x Z 3Y1 Ydxaasrp 2:aaar.�tauraN &stv— t azka JMRa'A>': �.... SWOS-APS SCI M$IS SOWS-ffSS 3t)60$"S so$01$-t40M Mtxewx sue.new .ses..a«a.. ft:amw.aalA.«a asw.•. G+sueib+ trNeaeu —..---� atxt�:ennr»cawx S[}."a041f> S03a9d.AJi�.4 EG#r@SORB 50303=L7�5QSp5-GSA➢' . � .. leb rrx4it.vav+ Hays ecs�...s I I I I I I i _v _a _.s . .... I r I 5sb� 5[?S4�.pttC7R SG34d�s S 5S SDSb4�-A11hd BC��1.iA.ttk1 4uffi�4fb-1.5A I aal4 M3»toNEa 3ry NM1 Ca�x ..�Cwrr.Ha .e#ar.mrab4 4S,tiY'?taYSt%P '1s+93.4bs `afkMilPHfnaia tgbJ1�B,,yrPA (ilk/�A?1.haE I.i?A IS#32t I w"N}4a4 h'�Jd :k+dCMF0ea1'S I I I i Uge Me 5—WO W Wn1fQ1 U £a54 1 I l5if ze+�cee+ar i , r iRrul�iex L I --________a ALARMINTELLIKNIGHT FIRE RO PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz,2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using a Total Accessory Load: 6A @ 27.4 VDC, and 586OR is red. PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system.5820XL supports three (SKSS) Flexput Circuits: 5815XLs. Each 5815XL can support 127 Powerful end-user facility management Six programmable circuits which can be devices. software allows viewing of detector programmed individually as: 5895XL Intelligent Power Module status and event history via modem or Notification circuits: 3A @ 27.4 VDC per Adds 6 amps of power, 6 Flexput 1/0 direct connection. circuit, power-limited circuits and 2 Form C relay circuits to a Plex-1 Auxiliary power circuits: 3A @ 27AVDC 5820XL system. Dead front cabinet door with clear per circuit, power-limited 5496 Intelligent Power Module window to limit access to the FACR Initiation Circuits: 100 mA @ 27AVDC A 6 amp notification power expander that RBB per circuit, power limited provides four power-limited notification Remote battery box accessory cabinet. appliance circuit outputs. Use if backup batteries are too large to Physical 5880 LED/10 Module fit into FACP cabinet. Dimensions: Flush Mount Dimensions: Features 40 LED outputs, 8 normally 16"W x 10" H x 6"D 14.5"W x 24.75"H x 3.9"D open dry contact inputs, and one piezo (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm) output. SD505-DTS-K 5865-3 and 5865-4 Remote test switch. Used with Overall Dimensions: Remote LED Annunciator SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Features 30 programmable LED (15 red operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) and 15 yellow)outputs, and a piezo of detector alarm. sounder.The 5865-4 adds a silence and Hochiki and SK Devices Weight: 28 lbs. (12.8 kg) reset switch to the package. See the specification sheets listed below 5883 Relay Board for a complete listing of the Hochiki and Color: Red Features 10 general purpose Form C SK devices. relays. Used with 5880 module. 53624 Hochiki Devices Battery Charging Capacity: 7.0-35 AH 5824 Serial/Parallel Printer Specification Sheet Interface Module 53623 SK Device Protocol Battery Size: 18 AH max allowed in Provides one parallel and one RS-232 Devices control panel cabinet. Larger capacity serial port for connecting a printer to the Specification Sheet batteries can be housed in RBB 5820XL. Use to print a real-time log of accessory cabinet. system events, detector status reports, and event history. Interfaces with Telephone Requirements: building control system. FCC Part 15 and Part 68 approved Type of Jack: RJ31X(two required) SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all Made in America KNIC1 T requirements.All specifications are subject to change without notice.For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 Phone:(203)484-7161, PN 350210 Rev F Honeywell Fax:(203)484-7118.www.silentknight.com. ECN 09-520 09/09 by IntelliKnight&JumpStart are Registered Trademarks of Silent Knight ©2009 Honeywell International Inc. Flexput is a Trademark of Silent Knight INTELLIKNIGHT O. 5860 Remote Annunciator Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The RS-485 interface to panel annunciator is ergonomically • Operation and appearance is designed with over-sized buttons identical to 5860 built-in for the most frequently used annunciator features, like Reset and Silence. On-board piezo sounder audibly 3 indicates alarms, troubles, and In addition to status messages displayed on the LCD, there are supervisories five LEDs for alarm, supervisory, • Five status LEDs for alarm, supervisory, trouble, silence and ` trouble, silence, and AC power AC power conditions status. 5860 • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP(depending on wire Color to match virtually any decor and gauge and number of devices on 5860R: Red red for applications where the SBUS) 5860: Gray annunciator must stand out. The • UL listed, complies with NFPA 72 • CSFM approved Environmental annunciator enclosure can be pp Operating Temperature: 32°F— surface or flush mounted.A trim Electrical Specifications 120°F (0°C—49°C) ring kit is available for surface Operating Voltage: 24 VDC Humidity: 10% — 93% non- mounting. Standb Current: 20 mA max Y condensing Features Alarm Current: 25 mA Approvals • 80-character backlit LCD display Wiring Distance: 6,000 max. from NFPA 72; UL Listed; (4 lines with 20 characters on FACP(depending on wire gauge each line) ( p 9 g 9 CSFM 7170-0559: 135; • Tactile and audible feedback and number of devices on the MEA 429-92-E Vol. IX; • Accepts user codes or fire SBUS) FM Approved fighter's key Max Per System: 8 • Larger keypad buttons for system Mechanical Specifications STLEW reset and silence Physical 9.1" W x 7.4" H x 1.5" D KNICHT • Install up to eight 5860s per (23.1 W x 18.8 H x 3.8 D cm) FACP °Hats ► '.' Shipping Weight: 2.8 Ibs (1.3 kg) II ACCESSORY5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Epp to 600 Feel From FACIP SBUS 5ti p to Bot SM9,Pet System Campaftft la"Km4w fA Compatibility Ordering Information Accessories IntelliKnight 5820XL FACP 5680R Remote Annunciator 5860TR Red Trim Ring IntelliKnight 5808 FACP Four line LCD annunciator with 20 For surface mounting. IntelliKnight 5700 FACP characters per line. Red. 5860TG Gray Trim Ring 5680 Remote Annunciator. For surface mounting. Four line LCD annunciator with 20 characters per line. Gray. SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350224 Rev C,05/06 subject to change without notice. For more information,contact Silent Knight 7550 Meridian Circle Suite 100,Maple Grove,MN 55369A927. ©2007 Honeywell International Inc. Phone: (800)328-0103, Fax: (763)493-6475. FIRE SYSTEM ACCESSORY 5496 Intelligent Power Module A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most- powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from Gentex®, System Sensor®, Faraday, AMSECO and Wheelock® — what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-446-6444. Model 5496 3 amps per output circuit Intelligent Power Module Ground fault detector The model 5496 is a 6 amp notification Communicates to the FACP via 4- power expander that provides its own wire SBUS (wire runs up to 6000 ft) AC power connection, battery charging AC loss delay option shuts off power circuit, and backup battery for use with to non-essential high-current fire and security controls such as the accessories like magnetic door IntelliKnight Model 5808 Fire Control holders /Communicator. The 5496 is the cost- Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). UL 864,1481 & 1971 listed The 5496 has built-in ANSI cadence pattern, which can upgrade older ANSI Cadence pattern output control panels that lack cadence capability built-in capability. The Output circuits can be Specifications programmed as Notification Appliance AC Input 120 VAC at 2.7 A Circuits, or as Auxiliary Power Output: 24 VDC at 6 amps (configurable for, constant, resettable, or door holder power). Curren: 40 mA Model 5496 Intelligent Sta Features Alarm y 160 mA Power Module UL Listed for 6 amps of notification Ambient Temp.: 32'to 120'F Notification/Aux. power 0°to 49°C Power supply's advanced switch Power circuits: 4 Dimensions: 12.25"W x 16"H x mode design reduces damaging Output 3"D(30.88 cm W heat and manages power up to 50% configuration: 2 Class A(Style Z) x 40.64 cm H x more efficiently than other systems 4 Class B(Style Y) 7,62 D cm) (1 Class A& Built-in synchronization for 2 Class B) Approvals: UL appliances from AMSECO, GentexF, Faraday, System Sensor�F, and Amps per CSFM Wheelock"% output circuit: 3.0(6.0 amps total) MEA 429-92-E vol. XIV • 24 VDC filtered output voltage Notification Four power-limited notification circuit output: 20.4 to 27.3 VDC outputs; 2 Class A or 4 Class B, or 1 @ 3.0 amps each, 4.7k EOL resistor Class A and 2 Class B required on each NACs are programmable as Class B circuit , Notification Appliance Circuits, or as Batttery charging SILENENT auxiliary power to be used as capacity: 35.0 AH constant, resettable, or door holder power by ey"11 SK-Pull-SA ` �i and SK-Pull-DA Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA/SA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103 or in Connecticut, call (203)484-7161. Description I The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[131) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility The SK-Beam and SK-Beam-T are compatible appears, clearly indicating the station has been pulled with the following IntelliKnight FACP's: • Rotary address switches for fast installation 5700 5808 • UL Listed, including UL 38, Standard of Manually Actuated 5820XL Signaling System SILL" INIT by ell INTELLIKNIGHT ACCESSORY Model SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21OLP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. y ) i s RAI l f 3 t y a E t 0 I 9 � �s • 3 9 1 a _............-c...=•M.,....».._..,...,,_....... ----••......„ ,»�..-,�-,-,.ate A�. SILE1447T This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KN14G HI" keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject FORM#350118 Rev A, to change without notice. For more information,contact Silent Knight 12 ©2009 Honeywell International Inc. by Ho Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. www.silentknight.com FIRE SYSTEM O. Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Wputs pr r mmabl r as Auxiltary Pore <)Uw I dd , SBUSCorriffhInicatim to a CmVatibfe Output _ __ i rA fit FACP '141111111O tit Auxillwy power can be programmedto be,constarit reseltable, or do of Compatible FACPs IntelliKnight 5700 IntelliKnight 5808 IntelliKnight 5820XL I SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA fKNI JyRr to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350387 Rev C subject to change without notice. For more information,contact Silent ©2008 Honeywell International Inc. by Han Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone:(800)328-0103, Fax:(763)493-6475. www.silentknight.com SK-Monitor P ` Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103 or in Connecticut, call (203) 484-7161. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor is intended for use in t, intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble ." x conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised SK-Monitor • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate Compatibility The SK-Monitor is compatible with the following • Rotary address switches for fast installation IntelliKnight FACP's: • SEMS screws for easy wiring 5700 • UL Listed 5808 5820XL Installation The SK-Monitor mounts directly into a 4"square electrical box. The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor0 PN SMB500) is available from Silent Knight. L SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SK-Pull-Da and SK-Pull-SA Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. y 9§fr'E 3 f A FACP IP ¢t - SaI Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5" (14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 321— 120OF (0°C—49°C) Bi-Colored LED: Humidity: 10% —93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-1/0 Surface backbox This document is not intended to be used for installation purposes.We try to SILEW keep our product information up-to-date and accurate.We cannot cover all MADE IN AMERICA JCIIaT specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight FORM#350135 Rev A 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, ©2009 Honeywell International Inc. by Horwywell Fax:(203)484-7118. www.silentknight.com ACCESSORYINTELLIKNIGHT SK-Photo sA and SK-Photo-T Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, call (203)484-7161. Description Plug-in mounting provides ease of SK-Photo and SK-Photo-T are plug-in installation type smoke sensors that combine a Tamper-proof feature available on photoelectric sensing chamber with mounting bases addressable analog communications. Listed for use in duct applications $ Point ID capability allows each detector's address to be set with rotary Rotary address switches for fastn tf address switches, providing exact installation detector locations for selective UL Listed ;` maintenance when chamber T= contamination reaches unacceptable FM Approved m . levels. Specifications ry SK-Photo and SK-Photo-T have a ° unique optical sensing chamber that is Physical engineered to sense smoke produced Height:2.0"(5.0 cm) by a wide range of combustion Diameter:4.1"(10.4 cm) sources. In the SK-Photo-T, dual Shipping Weight: 5.2 oz. (147 g) SK-Photo (Base included) electronic thermistors add 135OF (57°C) Electrical thermal technology to maximize Operating Voltage: 15-32 VDC Compatibility detection. Standby Current: The SK-Photo and SK-Photo-T are compatible with the following Features 300 pA @ 24 VDC Maximum IntelliKnight FACPs: • Sleek, low-profile design Alarm Current: 6.5 mA @ 24 VDC max 5700 • Base included (with LED on) 5808 • Reliable analog communications for Environmental 5820XL trouble-free operation Operating Temperature SK-Photo and SK-Photo-T are • Age resistant polymer housing SK-Photo:321—120°F (0°C—49°C) compatible with the following detector SK-Photo-T.321— 1001F (0°C—38°C) bases: • Dual electronic thermistor design on Humidity: 10%—93% non-condensing B210LP (included)6"base the SK-Photo-T B501 2 wire base reliability y • Superior EMI resistance for Other Ratings B501 BHT-2 Temporal base SK-Photo-T Thermal: Fixed 6224RB Relay base • Simple field cleaning for code temperature set point 1350F (57°C) B224BI Isolator base compliance Velocity:0—4000 fpm (0—20 m/sec) B501 BH-2 Sounder base • Variety of mounting options to meet SK-Photo Insect Screen.Hole Size: any application 0.016"(0.41 mm) nominal • Dual LED indicators for 3601 visibility SILENT • Detector transmits signal to indicate KNIGHT maintenance is required • Optional remote LED annunciator 17 Honeywel (System Sensor@ PN RA100Z) INTELLIKNIGHT ACCESSORY Model SK-Monitor To Nett Devk e - a Class a ', • 8 710rmIkin IMmCompotihle Silent Knight I—Of Previous Device n sa and tanvtcA' 'to"1)ro.*r ilmiteet 23 t2 VDC Max Q Class A Wring, �"• To Next Aevite 4 Class a ring; Any N uffibw of UL Listed Contact Closure LM Haw es May Be Used.0o"Wx Fire Alarm inNiAfftg 13eaatee3,Sulter .ser.st seeuetty 004kes l.f 1 j on lh*Sa du , s e From Cwnplillibk SUentX,rlght g s + FACP or Previous l vlce Ed7i1.R@B�ESf is Iplmrrvr�C ("'�at T ems Q a 9 "�) � 00 ' WirinD SX Moduln Specifications 5.5 mA(with LED latched on) Physical LED Current: 5.5 mA(with LED latched on)End-of-Line Height: 4.5" (11.4 cm) Resistance:47K Width:4"(10.2 cm) Initiating Device Circuit Wiring Resistance: 1,500 max Depth: 1.25"(3 cm) SLC Loop Resistance:40 max. Shipping Weight: 6.3 oz(196 g) Environmental Electrical Operating Temperature: 320F— 120OF (0°C—49°C) Operating Voltage: 15—32 VDC Humidity: 10%—93% non-condensing Current Draw (LED on): 5.0 mA max Operating Current(LED flashing): 375 pA Ordering Information Standby Current: SK-Monitor Monitoring Module 400 pA max @ 24 VDC (one communication every 5 sec with Accessories 47K EOL) SMB500 4"Square Surface Mount Electrical Box 550 pA max @ 24 VDC (one communication every 5 sec with EOL<1K) This document is not intended to be used for installation purposes.We try to MADE IN AMERICA SI LEW. keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight FORM#350131 Rev A - 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, ©2009 Honeywell International Inc. by Honeyweil Fax:(203)484-7118. www.silentknight.com NTELUMIGHT ACCESSORY SK-Relay k Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the Intelliknight system, or to locate you nearest source, please call 800-328-0103 or in Connecticut, call (203)484-7161. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated " sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. L3!" The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK-Relay is with a unique signaling line circuit SLC loop programmed q g 9 ( ) P 51 address. When an event occurs that controls the SK-Relay, the SK-Relay relay is triggered by the FACP. Installation Features The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2-1/8".A surface mount electrical box • Rotary address switches for fast installation (System Sensor@ PN SM6500) is available • Contacts are rated for a variety of amps (see Specifications) from Silent Knight • Panel controlled status LED that flashes green in normal state and is solid red in alarm Compatibility The SK-Relay is compatible with the following • Relay programming is completely flexible—can be mapped to IntelliKnight FACP's: zone conditions 5700 5808 • Polling LED visible through the cover plate 5820XL • Attractive ivory cover plate • SEMS screws for easy wiring SILENT J • UL Listed KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SK-Relay To Next device + 41 ---�-- If Any Wiring to Terminals 3—9 is Not Power Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, ..01 Which dust Be Placed Over the Power Limited 00 0 lz� Terminal Inton-nation on the Name Plate Label, Relay Common 2 F yFi, Normally Closed 2 `. • Normally Opert 2 Relay Co►r mot1 1 '.1 ••'"' From Compatible FACP Normally Closed 1 s ,, + or Previous Device Module Does Not Supervise Normally Open 1 Controlled Circuits � "� t✓ Wiring the SK•Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA(with LED latched on) Depth: 1.1" SLC Loop Resistance: 40Q max. Shipping Weight: 6.3 oz(196 g) Relay Contact Ratings Electrical 3.OA @ 30 VDC resistive Operating Voltage: 15—32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current: 0.5A @ 125 VAC inductive (PF = .35) 230 pA(LED flashing)direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA(LED flashing)group poll This document is not intended to be used for installation purposes.We try to SILENT keep IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight FORM#350127 Rev A by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, ©2009 Honeywell International Inc. Fax: (203)484-7118. www.silentknight.com SYSTEM SENSOR' Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert®Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTARM Riert Features The SpectrAlert Advance series of notification appliances is Electrically compatible with existing SpectrAlert products designed to simplify installations,with features such as plug in ® Automatic selection of 12-or 24-volt operation at 15 and 15/75 designs,instant feedback messages to ensure correct installation of candela individual devices,and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. •Plug-in design •Field selectable candela settings on wall and ceiling units:15,15/75, When installing Advance products,first attach a universal mounting 30,75,95,110,115,135,150,177,185 plate to a four-inch square,four-inch octagon or double-gang Same mounting plate for wall-and ceiling-mount units junction box.The two-wire mounting plate attaches to a single-gang •Shorting spring on mounting plate for continuity check before junction box. installation Next,connect the notification appliance circuit wiring to the SEMS •Tamper resistant construction terminals on the mounting plate. Outdoor wall and ceiling products rated from—40°F to 151°F •Design allows minimal intrusion into the back box Finally,attach the horn,strobe or horn/strobe to the mounting plate Horn rated at 88+dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Rotary switch for horn tone and three volume selections mounting plate's terminals.The device will temporarily hold in place •Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) with a catch until it is secured with a captured mounting screw. outdoor requirements Outdoor products NEMA 4X rated The SpectrAlert Advance series includes outdoor notification •Compatible with MDL sync module appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or Agency Listings dry applications. srcxauxc 7125-1653:186 Bndoor strobes) UCF M MEA 7120-:653:1 B3 tho /str bes, ) 7125-1653:1 B3 Qfo elstroes, LISTED approved chlme/strobesl LISTED APPROVED 7135-1653.189 horns,chimes) 54011 3023572 MEA452-05-E 55512 53593 SpectrAlert Advance Specifications Arch itect/Engi neer Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1 Yz-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x I IA-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,1 15,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon Flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,Flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 41'/16 x 41'1 x 21/s-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F VC to 49°C) K Series Operating Temperature —40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 Flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wail mount dimensions(including lens) 5.61 x 4.7 W x 2.5 D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wail-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x 5.0"W x 2.2-D(151 mm L x 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.25"high(180 mm diameter x 57 mm high) Wail-mount weatherproof back box dimensions(SA-WBB) 5.71 x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) Wail-mount trim ring dimensions(TR-HS,TRW-HS) 51-L x 4.812 W x 0.351)046 mm L x 122 W mm x 9 D mm) Ceiling-mount trim ring dimensions(TRC-HS,TRCW-HS) 6.9-diameter x 0.35 high(176 mm diameter x 9 mm high) j Notes: i 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. i I A05-0395-nos I i UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current t 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts k Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 % Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current rHorn/Strobe,Standard Candela Range(15-115 cd) 8-17.5Volts 16-33Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,High Candela Range 0 35-185 cd) 16-33 Volts 16-33 Volts DC input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candelaHorn Horn/Strobe Output(dBA) ratings must be reduced in accordance with this table. 24 Volt Nominal 8-17.5 16-33 Strobe Output(cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-407 Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 37F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8t Coded Medium 78 78 85 85 90 90 97 98 150 150 9t Coded Low 75 75 81 81 88 85 96 92 177 F77 tSettin95 7,8,and 9 are not available on 2-wire horn/strobe. 185 A05-0395-005 S ectrAlert Advance Dimensions 2.5' 6.6" 1..-�4.T. � Di.. 2.5" Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1- 7.1' �2.25+1 ,2,0• Dia. 5.05"—ter �2.23:1 Dia. `o o o O \ 00.0 p 2.0 0 0 s ® ®0 6.2" 5.98' O o p 0 0 O Q o O �.—5.1"—� Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn/Strobes Ceiling Horn/Strobes(contd.) P2R*t 2-wire Horn/Strobe,Standard cdt,Red PC4W 4-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P2111<*° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P2RHK° 2-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red '1 P2WH* 2-wire Horn/Strobe,High cd,White SCRK° Strobe,Standard cd,Red,Outdoor i P4R* 4-wire Horn/Strobe,Standard cd,Red SCRHK° Strobe,High cd,Red,Outdoor P4RH* 4-wire Horn/Strobe,High cd,Red SCW*t Strobe,Standard cd,White PORK' 4-wire Horn/Strobe,Standard cd,Red,Outdoor SCWH*t Strobe,High cd,White P4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor Horns P4W* 4-wire Horn/Strobe,Standard cd,White HR Horn,Red P4WH* 4-wire Horn/Strobe,High cd,White HRK° Horn,Red,Outdoor Wall Strobes HW Horn,White SR*t Strobe,Standard cd,Red Accessories SRH*t Strobe,High cd,Red BBS-2 Back Box Skirt,Wall,Red SRK° Strobe,Standard cd,Red,Outdoor BBSW-2 Back Box Skirt,Wall,White SRHK Strobe,High cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red SW* Strobe,Standard cd,White BBSCW-2 Back Box Skirt,Ceiling,White SWH* Strobe,High cd,White TR-HS Trim Ring,Wall,Red Ceiling Horn/Strobes TRW-HS Trim Ring,Wall White PC2R* 2-wire Horn/Strobe,Standard cd,Red TRC-HS Trim Ring,Ceiling,Red PC2RH* 2-wire Horn/Strobe,High cd,Red TRCW-HS- Trim Ring,Ceiling,White PC2RK° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Notes: PC2RHK° 2-wire Horn/Strobe,High cd,Red,Outdoor *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g., PC2W*t 2-wire Horn/Strobe,Standard cd,White P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. PC2WH*t 2-wire Horn/Strobe,High cd,White #"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 PC4R 4-wire Horn/Strobe,Standard cd,Red candela settings."High cd,"refers to strobes that include 135,150,177,and 185 PC4RH 4-wire Horn/Strobe,High cd,Red candela settings. proof back box. PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor ❑ll outdoor PC4RHK° 4-wire Horn/Strobe;High cd,Red,Outdoor o model dnumber for weatherproof rerplacement device(no back box included). �1 SYSTEM ®znos sY=` 5 „ 3825 Ohio Avenue•St.Charles,IL 60174 ..entproa.°oss r ndudi n ye imoftems<n,sheet, , SEN.SORr curtznt�roduc[inramanon,indu35.8/3 -#2test version of this data sheet, Phone. •Fax:630-377-6495 nns o3es-oas 8/�H xzmr3 "STEM Z,4, ,SENSOR Mini-Horns The SpectrAlert'Advance series of mini-horn sounders are designed to simplify installations to provide A primary and secondary signaling for fire and security applications. SPECTf��ert A p, N C___E Features The MHR and MHW mini-horns operate at 12 and 24 volts and are 12 and 24V operation ideal for hotel,motel or residential fire system applications,where © a smaller notification device is desired.The mini horns offer high High and low volume settings and low volume settings,and temporal or non-temporal tones.The Temporal and non-temporal tones horns can be mounted to single gang back boxes for aesthetically Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. Compatible with MDL sync module Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-Alert"sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.The.y are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings u� FM MEA 0 LISTED APPROVED approved h1FJ?-J7-E "35-IEi3'1W SpectrAlert"Advance Mini-Horn Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box.Mini- horn shall be listed to Underwriter's Laboratories Standard 1.4.464 for fire protective signaling systems,Mini-horns shall operate between 32 and 120 degrees Fahrenheit fron)a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Synr Gicuit"Module,12-volt rated notification appliance circuit outputs shall operate between nine and 1 T5 volts 24-volt.rated notification appliance circuit outputs shall operate between 1/and 33 volts. Physical Specifications Dimensions 4.61 x 2.9 vV x.45"D Weight 2.67 oz. Operating Temperature Range 327 to 1207(0°C to 49°C) Mounting Surface:single-gang back box Flush.4-x 4 BBD deep back box(2!4"deep) Electrical Specifications Input Terminals 12 to 18 NvVG Nominal Voltage Regulated 12DC/FWR or regulated 24DC7FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data SounderOutput • Switch Setting Pattern Output Level 8-175 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White SYSTEM zca c s 3825 Ohio Avenue•St.Charles,IL 60174 e d,,�I �ra srrl I rr I _nsc �_�-•.r,r nrtr t I rfuci-(on aici I i�iix]tE it 1n.c o ihi•Aila h��i `l1r".1`,jY►y� SENSOR• Phone:800-SENSOR2•Fax:630-377-6495 cos c Inrro• c al Series MIZ Piezoelectric Mini Horns and Mini Strobe Horns Wheelock's MIZ Series piezoelectric Mini Horns and Mini Strobe Horns are compact electronic alarm signals that arer Listed under UL 464 for Audible Appliances and UL 1971 for Emergency Devices for the Hearing Impaired for use in pub- lic mode Fire Protection Systems. They are ideal for alarm signaling in individual rooms, apartments, hotels, offices- where attractive appearance, dependable performance and economical installation are prime concerns. MIZ Series Mini Horns produce high sound output (90 dBA at 10 feet) with minimum current draw, just 12 milliamps at 24 volts, 8 mA at 12 volts, and they are available with integral strobes to meet the latest code and ADA requirements for visible signaling. All Mini Horn models are designed for easy installation with convenient mounting to standard single-gang boxes and in- out screw terminals for fast wiring. They are ruggedly constructed of high impact thermoplastic and are available in fire alarm red or off-white color to blend with room decor. Features • High sound output for enhanced audibility (90 dBA at 10 feet). • Listed under UL Standard 1971 for Emergency Devices for the Hearing Impaired and UL 464 for Audible Appliances. • Designed to meet or exceed NFPA/ANSI Standards and ADA Accessibility Guidelines. ?_ • Low current draw with low temperature compensation to re- duce power consumption and wiring costs. • Mini Horn Strobe models available with 15, 15/75, 30, 75 and 110 candela ratings for single input activation. • Wheelock's patented LS, LSM, MS, IS and HSW Series ffR , strobe designs (with additional patents pending) offer fire alarm system designers, specifiers and installers the indus-try's widest selection of UL 1971 Listed strobe products. • 12 VDC and 24 VDC models with wide Listed voltage, fik tered DC and FWR. • Polarized inputs for compatibility with standard reverse po- Series larity type supervision of circuit wiring by an alarm panel. MIZ+HSW Low cost installation via standard electrical boxes. Attractive Series MIZ+LS/LSM/MSpS flush or surface mounting options. • No additional trimplate required for flush mounting. Easy in- stallation with In/Out screw terminals using#12 to#18 AWG. • Compliance with RFI limits in FCC Part 15,Class B for com- patibility with sensitive detection and communication circuits. Specification Information • Mini Horn and Mini Strobe Horn models are Listed for indoor use with a temperature range of 321 F to 1201 F (0° C to 49* C) and maximum humidity of 85% RH. • Rated input voltage(either filtered DC or unfiltered full-wave-rectified FWR): Strobes are designed to flash at 1 flash per second mini- mum from 20-31 VDC (for 24 VDC models)or 12-15.6 VDC(for 12 VDC models). Note that ADA guidelines presently specify a flash rate of 1 to 3 flashes per second.Check the minimum and maximum output of the power supply and standby battery and subtract the voltage drop from the circuit wiring resistance to determine the applied voltage to the strobes. Mini Strobe Horn Current Re uirement Am s Rated Avera a Current Rated Peak Current Rated Inrush Current Voltage LS MS LSM IS HSW LS MS LSM IS HSW LS MS LSM IS HSW 20 VDC .088 .143 .123 .248 .288 168 .296 .258 .508 .696 .218 .288 .233 .658 .558 24 VDC .092 .147 .127 .237 .242 .202 .308 .272 .462 .582 .262 .292 .282 .672 .672 31 VDC .102 .157 .137 _217 .254 .232 .318 .288 .392 .542 .342 .322 .382 .902 .872 20 VFWR .092 .147 .137 .252 .292 .222 .402 .362 .712 .972 .332 .402 .327 .932 d72 24 VFWR .098 .152 .142 .242 .247 233 .407 .382 .657 .847 .397 .407 .397 947 31 VFWR R16 .162 .152 .222 .217 .267 .417 .392 .547 .777 .477 .447 .527 1.277 10.5 VDC .226 - .346 .566 .476 --- --- .306 .506 .446 ---241 - 12 VDC .228 348 .568 .478 --- --- .308 .508 .448.243 --- 15.6 VDC .245 .230 - 350 570 .480 - .400 .660 .450 --10.5VFWR 248 -:.238 --- -- 483 73& : .668 . .708 488.. 743 .673,; .. &43b. 12VFWR. : ,.253 .243 - --15.6 VFWR .265 .253 --- --- 490 .745 1 .675 --- -- .560 .925 .675 -- -- V 12 whee lock Ordering Information Mounting A pr?o!valrs MIZ Model Voltage Order Strobe Current M Signals Code VDC Code Candela @ 10 ft Am s 0 tions UL 7" 008 A.B.- X 12—- 12 4478,"- M IZ-1 012 MIZ-24-R 24 4208 90 MIZ-24-W 24 4479 90 MIZ-24-LS-VFR 24 5191 15 90 24 VDC MIZ-24-LSM-VFR 24 5190 MIZ-24-MS-VFR 24 5376 MIZ-24-IS-VFR 1 24 1 53513 MIZ-24-H';W-HFR I 24 5192 110 90 x.Nou �X X" Dec- MIZ-I2=LS-VFRt 14 77: MIZ_,JZ V Nov-LSM-VF MIZ�i 2-MS-VFR_;"�. 12 NOTES 1. Models code suffix:v=vertical lens,H=horizontal lens;F=fire lettering;R=red plate. 2. Approval codes:UL=Underwriter Laboratories;cFm=California state Fire marshal;FM=Factory Mutual;MEA=New York City Materials and Equipment Acceptance;BFP=Chicago Bureau of Fire Prevention. SEE PAGE 4 FOR GENERAL AND TECHNICAL INFORMATION. Mounting Options _FLUSH B. SURFACE(MIZ-12/24) C. FLUSH(MIZ-Strobe Horn) D. SURFACE(MIZ-Strobe Horn) 15 cd 30 cd 15 Cd 75 ed I cd I S(75 Cd 56�' 7501 Cd Id IW75 cd • 0 c 0 DOUBLE-GANG.1-3/4' DEEP W IIEM.L. SINGLE-GANG 36 \X 0-41 SINGLE-GANG X 1-3/4' SINGLE-GANG 0-IZ DEEP WIREMOLD SINGLE-GANG x 3-1/2' DEEP WIREMOLD LENS OR DOUBLE GANG x 3-10 BACKBOX DEEP BACKBOX BACKBOX DEEP BACKBOX LENS MMMuMNUMaLRffSQftDU01M MMLMUKjuMft2kF CONDUCTORS MAXIMUM NLLMOE OF CONDUCTORS II f14 AWG,132 AWG.JIB AWG 116 AWG 114 AWG 012 AWG#1 AWG.#15 AW0314 AWG,112 AWG,11 AWG.116 AWG,#14 AWG,11 AM 11 AWG.11 4 4 4 4 4 4 _ 4 4 4 4 4 4 4 4 4 4 E FLUSH(MIZ-Strobe Horn(110 cd)) F. FLUSH(MIZ-Strobe Horn(110 cd)) o LENS LENS *I SINGLE-GANG x 3-112' f 2-GANG x 3-1/2' DEEP BACKBOX DEEP BACKBOX MAXIMI IM NUI OF CONDUCTOR MAXIMUM NUMBERDLONDLIUMS AWG.fIS AWS,#16 AWG.014 AWG-112 AMI136 AWS 016 AM 114 AWG 012 4 4 4 4 4 4 4 4 Mounting Note For Fire Alarm applications using white MIZ-Horns,a red"Fire"label is provided.Affix this label to the front of the mounting plate to identify the fun( tion of the alarm signal. wheebck SERIES MIZ Mini-Horns (Vheelock's MIZ SERIES piezoelectric Mini-Horns and Mini-Strobe Horns are compact electronic 117 CANDELA STROBE MODEL alarm signals that are UL listed for use in Fire Protection Systems.They are ideal for alarm signaling in individual rooms—apartments, hotels, motels,offices—where attractive appearance, ,,;ti dependable performance and economical I; installation are prime concerns: All models are designed for easy installation with MIZ convenient mounting to standard single-gang boxes and in-out screw terminals for fast wiring. They are ruggedly constructed of high impact thermoplastic and are available in fire alarm red or off-white color to blend with room decor. I FEATURES ■ High sound output for enhanced audibility (90 dBA at 10 feet). ■ Convenient flush mounting to standard single-gang ■ Low current draw to save on power supply and wire bdckboxes or surface mounting to Wiremold boxes. costs (15 milliamps max). ■ Wide operating voltage range for compatibility with ■ Fully assembled Strobe Horn models to save on unfiltered and unregulated power supplies. installation time-117 candela strobes. ■ Completely electronic design to minimize in-rush current ■ Just two screw terminals on all models for fast and and RFI noise. secure in-out wiring. ■ UL Listed for Fire Protective Service. ■ 117 candela strobe model for ADA applications ORDERING INFORMATION AND SPECIFICATIONS Model Order Color Volta a DC Current dBA @ Rated Mounting Approvals' Number Code (VDC (AMPS) 10 Feet Candela Options MIZ-12-R 4209 Red 12 0.010 88 MIZ-12-W 4478 White 12 0.010 88 A B UL, CFM, ULC MIZ-24-R 4208 Red 24 0.015 90 NYC, FM, BFP MIZ-24-W 4479 White 24 0.015 90 MIZ-24-WM-VF-R 4916 Red 24 0.103 90 117 C, D UL, CFM NYC, FM, BFP 'See Note 6 NOTES(see page 5 for general information and technical notes): 1. All 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC.All DC models can be used with filtered or unfiltered(full wave rectified)voltage. 2. dBA is measured at 10 feet in an anechoic chamber with peak meter response.Nominal output frequency is 2900 Hz. 3. Use standard 21/2"deep gang boxes for flush mounting.Use 13/51 deep wire mold boxes for surface mounting(13/4"deep for rear conduit entrance). 4. Strobes operate only in unison with the audible signal using continuous non-interrupted)input voltage. 5. All models are polarized for line supervision. 6. Approvals:UL = Underwriter's Laboratories, CFM = California Fire Marshal,NYC = New York City,ULC = Underwriters Laboratories of Canada(0.065A for 24 VDC ULC strobe horns with 3.0 candela strobe),FM = Factory Mutual,BFP = City of Chicago(Red grille only). MOUNTING OPTIONS A FLUSH B SURFACE C RUSH D SURFACE W LE GANG SINGLE GANG SINGLE GANGOUBLEWDOU�aLE GANG BACKBOX WIREMOLO BACKBOXMOLD BACKBOX BACKBOX 10 Z i caj ------------------ Sri r' �j PA:A!'j CHANDLER SQUARE ANACORTES, WA i EMERGENCY CALL SYSTEM PAGING SYSTEM AREA OF RESCUE ASSISTANCE SYSTEM MATERIAL SUBMITTAL PREPARED BY: COMMERCIAL ALARM&DETECTION, INC. PO BOX 128 MOUNT VERNON, WA 98273 360-848-1533 CONTACT: CHAD HOUTZ CHANDLER SQUARE MATERIAL SUBMITTAL INDEX Emergency Call System A. Tek-CARE 500 Call System A. TekTone NC501 ES Master Station Computer B. TekTone NC510ES Receiver C. TekTone SF501 ES Water-Resistant Call Transmitter D. TekTone SF502ES Wall-Mounted Call Transmitter E. TekTone SF531ES Wireless Emergency Call Station f F. TekTone NC511 ES Repeater/Locator 1 u� Paging System A. Tek-Paging On-Site UHF Paging System B. TekTone NC369 UHF Paging Transmitter C. TekTone NC399P Alphanumeric Pager Area of Rescue Assistance System A. TekTone NC 150R Master Station Panel B. TekTone Remote Call Stations K one Tek-CARE®500 Wireless Emergency Call System with EchoStream technology for foc .. wd err+ i Specification Sheets Submittal Package as of 12/10/2009 www.tektone.com Copyright©2003-2009 TekTone"'Sound& Signal Mfg., Inc.,All rights reserved. No part of these publications may be copied without the express written permission of TekTone®Sound&Signal Mfg., Inc.The contents of these specification sheets are Phone: (828)524-9967 furnished for informational use only, are subject to change without notice, and should Toll-Free: (800)327-8466 not be construed as a commitment by TekTone®Sound &Signal Mfg., Inc.TekTone® Tech Support: Option 2 Sound & Signal Mfg., Inc. assumes no responsibility or liability for any errors or Sales: Option 3 inaccuracies that may appear in this documentation. TekTone,the TekTone logo,Tek-Call,Tek-Care,Tek-Check-In,Tek-Com,Tek-Digicare, Tek-Door,Tek-Entry III,Tek-Guard,Tek-Micro,Tek-Micro II,Tek-MMARS II,Tek-NIOS, 277 Industrial Park Road Tek-NIOS II,Tek-Paging,Tek-Phone, Tek-Safe,Tek-Select II, Tek-Sentry,Tek-Sound, Franklin, NC 28734 Tek-Status and Tek-View are either registered trademarks or trademarks of TekTone` tektone@tektone.net Sound&Signal Mfg.,Inc.in the United States and/or other countries.All othertrademarks Fax:(828)524-9968 are the property of their respective owners. re �F I L801 NC501 ES Master Station Computer Section E Specification Sheet Rev.7-12/2009 FEATURES The NC501ES Master Station Computer is the Tek-CARE"500 Wireless Emergency Call System'scentral _ point for component integration.The NC501ES interprets NC501 ES data received by the NC510ES Receiver and alerts staff via video display and audio ifa transmitteris activated,develops i a a problem,or leaves the coverage area.The monitor displays the locations ofpl aced calls(exact location for wall-mounted {' transmitters;nearest NC511 ES Repeater/Locator forpendant transmitters)and other pertinent information about calls in progress.Call information is stored in a historical record for later retrieval and analysis.The NC501 ES also sends event information to optional staff pagers via an NC369 Pager Transmitter.Software is included to provide remote event monitoring and reporting on up to 9 networked computers. TheNC501ES supportsavarietyofsystemdevices,including receivers,repeater/locators,pendant call transmitters,wall- mounted call transmitters,wireless smoke detectors,motion O ARCHITECTS' AND ENGINEERS' detectors, door/window egress transmitters, maintained SPECIFICATION N.O.andmomentatyN.O.universal transmitters,emergency stations,and pocket pagers with pager transmitter. The master station computer shall be TekTone�r NC501 ES or approved equal.The NC501ES shall use the Windows SPECIFICATIONS XP operating system and shal I have at minimum an 800 MHz processor, 128 MB of RAM,a CD-ROM drive,an SVGA PC using Windows XP with: 800x600 video adapter and monitor, a keyboard and a 28 MHz minimum processor 1 mouse.The NCSOIES Master Station Computer shall be a 28 MB of RAM or higher dedicated system for the Tek-CARE9500 Wireless SVGA800x600minimumvideoadapterandmonitor Emergency Call System. CD-ROM drive • Keyboard and mouse TheNC501ES central computerand software shall interpret data received by theNC510ES Receiver,and shall display REQUIRED COMPONENTS all patient/resident,transmitter and pager information.The NC510ES Receiver software shall alert staff via video display and speaker audio if a transmitter is activated,develops a problem,or Tek-CARE peripherals leaves the coverage location.Themonitor shall displaythe TekTone' has designed Tck-CARE"500 to work as a system. Its location of placed calls(exact location for wall-mounted master station computer has been carefully designed and matched to transmitters; nearest NC511ES Repeater/Locator for work with Tek-CARE"500 wireless and wired peripherals.TekTone`` pendant transmitters)and otherpertinent information about will not wan-ant or support components of Tek-CARE1500 that are purchased separately unless the components are add-ons to previously calls in progress. Call information shall be stored in a sold systems.TekTone will also not warrant or support a system that historical record for later retrieval and analysis.TheNC501ES is a mix of TekTone'''and Non-TekTone''parts,unless prior permission shall be able to send event information to optional staff has been obtained. A site survey must be performed and submitted pagers via an NC369 Pager Transmitter. before ordering a Tek-CARE'500 system. In order to track our systems and to inform facilities of software upgrades, full site information (site name, address and phone number) will be required when ordering.Site information and master station computer warranty numbers will also be required when requesting technical support. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • tektone@tektone.net Phone: (828)524-9967 • Fax: (828)524-9968 • Tech Support: Choose option 2 • Sales: Choose option 3 TekTone®'s quality system is registered by UL'I to the ISO 9001 standard.(Reference#10001510.) re MOW IL802 NC510ES Receiver Section E Specification Sheet Rev.4-12/2009 FEATURES The NC510ES Receiver enables communication between „rotl may` transmitters and the NC50 1 ES Master Station Computer in a Tek-CARE"500 Wireless Emergency Call System.The NC510ES facilitates the supervision ofall transmitters.The ' NC510ES's 900 MHz spread-spectrum radio provides reliability,even in hostile or difficult radio environments. Echostream technology with diversity reception and advance signal processing minimizes nulls or dead spots. The NC510ES Receiver includes slots through the side and bottom ofthe case for wiring.Transmitters are programmed using default information stored in the receiver. NCSIOES Facilitates supervision of transmitters 900 MHz spread-spectrum radio • Snap-on/pry-off cover SPECIFICATIONS Dimensions: 6.5"W x 3.5"H x 1.0"D ARCHITECTS' AND ENGINEERS' (165 mm x 89mm x 25 mm) SPECIFICATION Weight: 5.3 oz. Power Required: 12 VDC provided by PK510 Power The receiver shall be TekTone'NC510ES or approved Supply/PC Interconnect Assembly equal.The receiver shall intetface with the NC501AMaster Frequency: 902-928 MHz frequency-hopping Station Computer. A serial data interface shall translate spread spectrum messages from the wireless receiver to theNC501A.The Environment: 0°-60°C (32°-140°F) and up to receiver shall manage signals between end devices,high- 90%non-condensing relative humidity power repeaters,and the NC501 A Master Station Computer. The receiver shall report the following transmitter fault conditions:low battery,tamper and missing.The receiver REQUIRED COMPONENTS shall use a frequency-hopping spread spectrum with an operating frequency of 902-928 MHz. Tek-CARE'S00 Wireless Emergency Call System TekTone1° has designed Tek-CARE1500 to work as a system. Its master station computer has been carefully designed and matched to work with Tek-CARE'500 wireless and wired peripherals.TekTone" will not warrant or support components of Tek-CARE'�'500 that are purchased separately unless the components are add-ons to previously sold systems.TekTone"'will also not warrant or support a system that is a mix of TekTone`and Non-TekTone°parts,unless prior permission has been obtained. A site survey must be performed and submitted before ordering a Tek-CARE1500 system. In order to track our systems and to inform facilities of software upgrades, full site information (site name, address and phone number)will be required when ordering.Site information and master station computer warranty numbers will also be required when requesting technical support. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 tektone@tektone.net Phone: (828)524-9967 • Fax: (828)524-9968 • Tech Support: Choose option 2 • Sales: Choose option 3 TekTone®'s quality system is registered by ULe to the ISO 9001 standard.(Reference#10001510.) re R I L805 SF501 ES Water-Resistant Section E Single Button Call Transmitter Rev.4-12/2009 Specification Sheet FEATURES The SF501ES Single Button Call Transmitter pendant lop features the great range and reliability of900 MHz in a small, water-resistant package.Users can wear the pendant in the shower or bathtub,outside in the rain,or other environments where the pendant may be splashed with water or 4 momentarily submerged.A single-button design with"press and one-second hold"activation makes the product very •, easy to use, yet still reduces false alarms. When the SF501ES is activated,it continues to send an alarm signal until its reset button,located on the back,is pressed. The SF501ES is especially suited for assisted living SF501ES installations. Weighing less than 1.4 ounces, it includes both a neck cord and a belt clip, and can easily be converted by the end user. An optional wristband allows the pendant to be worn on the wrist or arm. The SF501ES features a fully supervised RF link to ensure ARCHITECTS'AND ENGINEERS' reliability.The built-in LED flashes with all transmissions, ® SPECIFICATION including supervision,so the user can see that the transmitter is still functioning.The battery is a customer-replaceable Thewireless call transmitter shall beTekTone"SF501ESor 3V lithium type. approved equal. It shall use the 900MHz frequency for signal transmission, and shall include a transmission Fully supervised wireless 900MHztransmitter indicator LED.No physical wiring connections shall be Water-resistant required to transmit a call.When activated,the SF501ES Large alarm button with alarm activation delay shall continue to send an alann signal until its reset button, Low battery warning before battery depletion located on the back,is pressed.The transmitter shall also Flashing LED indicator during alann activation include a neck chain,belt clip,and 3V lithium battery.The Continuous alarm signal until reset button pressed transmittershallbenolargerthar12.2"x1.9"x0.72"andshall Field-replaceable,3V lithium battery be lightweight enough to be worn comfortably. SPECIFICATIONS Dimensions: 2.2"H x 1.9"W x 0.72"D (56 mm x 48 mm x 18 mm) TekTone''' has designed Tek-CARE''500 to work as a system. Its Weight: 1. oz. master station computer has been carefully designed and matched to work with 1'ek-CAREN'500 wireless and wired peripherals.TekTone'n Range: I mile,open field will not warrant or support components of Tek-CARG1500 that are Environment: 0°C-600C purchased separately unless the components lire add-ons to previously Battery: 3V Lithium(BA501) sold systems.TekTone will also not warrant or support a system that is a inix of TekTone"and Non=rekTone'"parts,unless prior pennission has been obtained. A site survey must be performed and submitted REQUIRED COMPONENTS before ordering a Tek-C ARE"500 system. In order to track our systems and to inform facilities of software upgrades, full site information (site name, address and phone number) will be required Tek-CARE`"500 WtrelessEmergencyCallSystem when ordering.Site information and master station computer warranty numbers will also be required when requesting technical support. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • tektone@tektone.net Phone: (828)524-9967 • Fax: (828)524-9968 • Tech Support: Choose option 2 Sales: Choose option 3 TekTone's quality system is registered by ULI to the ISO 9001 standard.(Reference#10001510.) Te kCn IL806 SF502ES Wall-Mounted Section E Call Transmitter Rev.4-12/2009 Specification Sheet FEATURES The SF502ES Wall-Mounted Call Transmitter is for use as a call button or check-in button with the Tek-CARE"1500 WirelessEmergency Call System.The SF502ES Transmitter ' has a sleek, smart design with simple, single-button activation.The SF502ES requires no wiring connections and operates on the 900 MHz frequency. The LED flashes on all transmissions,including supervision, y so the user has a visual signal that the unit is transmitting. The transmitter can be supervised.It can be easily mounted for fixed position signaling,and also includes a neck cord for use as a pendant. The 3V lithium battery is user replaceable. Fully supervised Wireless 900MHz transmitter. Large alarm button with alarm activation delay. • Low battery warning before battery depletion. • Flashing LED indicator during all transmissions. SF502ES Field-replaceable 3V lithium battery. SPECIFICATIONS Dimensions: 311H x 1.611W x 0.72"D ARCHITECTS'AND ENGINEERS' (76 mm x 41 mm x 18 mm) Weight: 1.7 oz. SPECIFICATION Battery: 3V Lithium(BA502) The wall-mounted call transmitter shall be TekTone"' SF502ES or approved equal. It shall use the 900M14z REQUIRED COMPONENTS frequency for signal transmission and shall include a transmission indicator LED. No physical wiring Tek-CARE-*500 Wireless Emergency Call System connections shall be required to transmit a call. The transmitter shall also include a neck chain and a 3V lithium battery. The transmitter shall be no larger than 3"x 1.6"x 0.72". TekTonen has designed Tek-CARE®500 to work as a system. Its master station computer has been carefully designed and matched to work with Tek-C.ARE*500 wireless and wired peripherals.TekTonex will not warrant or support components of Tek-CARE10500 that are purchased separately unless the components are add-ons to previously sold systems.TekTone"will also not warrant or support a system that is a mix of TekTone a and Non-TekTone parts,unless prior permission has been obtained. A site survey must be performed and submitted before ordering a Tek-CAW500 system. In order to track our systems and to inform facilities of software upgrades, full site information(site name, address and phone number)will be required when ordering.Site information and master station computer warranty numbers will also be required when requesting technical support. www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • tektone@tektone.net Phone: (828)524-9967 • Fax: (828) 524-9968 • Tech Support: Choose option 2 • Sales: Choose option 3 TekTonel's quality system is registered by UL` to the ISO 9001 standard.(Reference#10001510.) � I L840 SF531 ES Wireless Section E Q Emergency Call Station Rev. 4 - 12/2009 Specification Sheet FEATURES t11"1�� The SF531ES Wireless Emergency Call station features the great range and reliability of 90OMHz signaling.This unit can be wall mounted near any resident location for call placement (stainless steel and other metal fixtures may interfere with the signal transmission). Calls are latched locally to ensure that residents receive direct staff attention.The device includes a call assurance ' LED.The pull cord supplied may be used for emergency :. call activation,or if desired,the large 1.1"(28 mm)red pull-down lever may be used. The SF531ES features a fully supervised RF li A to ensure rel iabil ity and to monitor " battery state. The battery is a customer replaceable 3V nu lithium. Fully supervised wireless 90OMHz transmitter Low battery warning before battery depletion . .�;. Call assurance LED SF531ES Wireless Emergency Call Station Field replaceable 3V lithium battery (Cord Not Shown) SPECIFICATIONS Dimensions: Height: 4.5" (114 min) ARCHITECTS' AND ENGINEERS' Width: 2.75" (69 min) SPECIFICATION Depth: 2.25" (58 min) Projects: 0,4375 (11 mm) The Wireless Emergency Call station shall beTekTone"s Construction: Flame-retardant(L1L'"94V-0)plastic SF531ES or approved equal. It shall use the 90OMHz Housing: Plastic single-gang box frequency band for signal transmission and shall include Battery: 3.OV Lithium(BA505) an LED call assurance indicator.Operation of emergency signal s shall be accomplished by a short pull on the nylon REQUIRED COMPONENTS cord or by pulling down on the red lever marked EMERGENCY. Calls shall be locally latched and require Tek-CARE`1500 Wireless Emergency Call System local reset to clear.No physical wiring connections shall be required to transmit a call.The station shall include a 3V lithium battery. Tek'.I one'has designed 1ek-CARE'a500 to work as a system.its master station computer has been carefully designed and matched to work with Tek-CAREr°500wireless and wiredperipherals.TekTonertB will not warrant or support components of Tek-CAREx'500 that are purchased separately unless the components are add-ons to previously sold systems."1'ekfone will also notwarrant or support a system that is a mix of7'ek'foneand Non- TekTone''r parts,unless prior permission has been obtained.A site survey must be performed and submitted before ordering a Tek-CARE1500 system.In order to track our systems and to inform facilities of software upgrades,full site information(site name,address and phone number)will be required when ordering.Site information and master station computer warranty numbers will also be required when requesting technical support. JU www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • tektone@tektone.net Phone:(828)524-9967 • Fax:(828)524-9968 • Tech Support: Choose option 2 • Sales:Choose option 3 TekTonO's quality system is registered by UL®to the ISO 9001 standard.(Reference#10001510.) re kToMT I L803 NC511 ES Repeater/Locator Section E Specification Sheet Rev.3-12/2009 FEATURES i The NC511 ES is a high power repeater and locator for the . .&�1� - Tek-CARE'`500 Wireless Emergency Call System. The 1 NC51 I ES repeater/locator al low s greater distances between the Tek-CARE1500 Transmitters and Receiver,and also provides general transmitterlocation information.Its range T makes the repeater/locator apractical solution for open-air !' installations such as campuses, buildings with multiple ' wings, and other large wireless projects. The NC51 IES �„ ;•r.��� �' � Repeater/Locator uses signal strength to distinguish between virgin and retransmitted signals,to ensure that the NC511ES NC510ES Receiver is sent accurate location information. Wireless radio protocols and Signal Synchronization Technology'"allow the repeater/locatorto act intell igently, amplifying transmission from any Tek-CARE"'500 ARCHITECTS' AND ENGINEERS' transmitter while ignoring background noise. SPECIFICATION Enhances wireless transmission range • Provides general location of calling transmitters The repeater/locator shall be TekToner" NC511ES or Signal synchronization processing minimizes approved equal.The repeater/locator shall increase alarm excessive signal generation transmission range,and shall provideat least 200milliwatts Easy to install just mount and plug in of effective radiated RF power.It shall also detennine the Supervised radio link to home receiver general area from which an alarm transmission is sent,and Includes integral backup battery shall transmit that information to the NC510ES Receiver and/or other NC511ES Repeater/Locators.The repeater/ locator shall distinguish between virgin and retransmitted SPECIFICATIONS signals, to ensure that the NC510ES Receiver is sent accurate location information.Alarm and supervisory check- Dimensions: 3.5"H x 6.5"W x VD signals from transmitters shall be maintained reliably (89min x 165 min x 25 min) with multiple repeater/locators in the system.The repeater/ Weight: 7.14oz. locator shall not require a home-run wire back to the Environment: -4°F-1400F,0%-90%non-condensing receiver or panel. relative humidity Power Required: 12-16.5 VAC or VDC (transformer included) Backup Battery: 2450mAH @ 3.7V lithium-ion(included) TekTone'a has designed Tek-CARE''500 to work as a system. Its Backup Time: Up to 24 hours(varies depending upon master station computer has been carefully designed and matched to repeater usage) work with Tek-CARE".500 wireless and wired peripherals.TekTone" will not warrant or support components of Tek-CARE*500 that are purchased separately unless the components are add-ons to previously REQUIRED COMPONENTS sold systems.TekTone will also not warrant or support a system that is a mix of TekTone"and Non-fekTone'parts,unless prior permission Tek-CARE"500 Wireless Emergency Call System has been obtained. A site survey must be performed and submitted before ordering a Tek-CARE11500 system. In order to track our ACCESSORIES systems and to inform facilities of software upgrades, full site information (site name, address and phone number) will be required when ordering.Site information and master station computer warranty IH511 Weatherproof Housing numbers will also be required when requesting technical support. BA511 Replacement Backup Battery www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • tektone@tektone.net Phone: (828)524-9967 • Fax: (828)524-9968 • Tech Support: Choose option 2 • Sales: Choose option 3 TekTone®'s quality system is registered by UL11to the ISO 9001 standard.(Reference#10001510.) rekTo""n'"W Tek-PAGING° On-Site UHF Paging System Communications for today... and tomorrow Specification Sheets Submittal Package as of 07/08/2009 0 www.tektone.com Copyright©2001-2009 TekTonel'Sound& Signal Mfg., Inc., All rights reserved. No part of these publications may be copied without the express written permission of TekTone-Sound &Signal Mfg., Inc.-The contents of these specification sheets are Phone: (828)524-9967 furnished for informational use only, are subject to change without notice, and should Toll-Free: (800)327-8466 not be construed as a commitment by TekTonel Sound & Signal Mfg., Inc.TekTone® Tech Support: Option 2 Sound & Signal Mfg., Inc. assumes no responsibility or liability for any errors or Sales: Option 3 inaccuracies that may appear in this documentation. TekTone,the TekTone logo,Tek-Call,Tek-Care,Tek-Check-In,Tek-Com,Tek-Digicare, 277 Industrial Park Road Tek-Door,Tek-Entry III,Tek-Guard,Tek-Micro,Tek-Micro II,Tek-MMARS II,Tek-NIOS, Tek-NIOS 11, Tek-Paging, Tek-Phone,Tek-Safe,Tek-Select 11, Tek-Sentry,Tek-Sound, LoFranklin, NC 28734 Tek-Status and Tek-View are either registered trademarks or trademarks of TekTone' tektone@tektone.net Sound&Signal Mfg.,Inc.in the United States and/or other countries.All other trademarks Fax: (828)524-9968 are the property of their respective owners. Tek o�W IL670 NC369 UHF Paging Transmitter Section E Specification Sheet Rev. 8 -07/2009 FEATURES The NC369 UHF Paging Transmitter receives alphanumeric messages and patient call information via serial interface and transmits the information directly to pagers.Information is sent to the transmitter at 9600 baud to minimize bottlenecks. Call type and location are determined by the system supplying information to the transmitter.Up to 1000 pager IDs are supported.Battery backup is also available.Programming is simple using a PC or laptop and web based programming screens. Dipswitches are also available on the unit for minimal function onsite setup. a;= ` The system's range depends upon the site and the transmitter's location. To determine the exact coverage, conduct a site NC369 survey. Estimate a range of up to one mile under ideal conditions. The unit includes a '/-wave BNC-terminated antenna to provide coverage that meets most requirements. The optional CAI 33 Antenna is suited for installations that require good building penetration and range.On average,the CA 133 Antennaadds about 25%to thetransmission footprint, and because it comes with approximately 10 feet of cable,it can be mounted in more locations. ARCHITECTS' AND ENGINEERS' SPECIFICATIONS SPECIFICATION Dimensions: 2.7" X 101, X 8" The UHF on-site paging system transmitter/control unit (6.86 cm X 25.4 cm X 20.32 cm) shall be TekTone*NC369 or approved equal.TheNC369 Construction: Electronic components mounted on a shall support one Tek-CARE"'NC300II,Tek-CARE'`400 PCB enclosed in an ABS housing or Tek-CARE"500 system.The paging information shall Connections: Plug-in RJ45 to DB9 be supplied to the unit at 9600 baud and shall be transmitted Housing: Surface or shelf mounted to the radio pagers at 1200 baud on 457.550 Mhz. Frequency: Programmable for 440-470 MHz Information such as call type,location and priority shall RF Power Output: Up to 2 watts be sent to the pagers in its entirety. LEDs shall indicate Voltage: 12VDC at 2A Input 115 VAC transmitter activity. FCC ID No.: T5GPT5 IC(Canada): IC4767A-PT5 The paging system shall support up to 1000 pager IDs and BAUD Rate: 9600 serial input, 1200 transmit shall have adjustable transmission strength of up to two watts(site survey recommended). REQUIRED COMPONENTS NC399P Pagers Tek-CARE"'400 Nurse Call System -or- Tek-CARENC300II Nurse Call System -or- Tek-CARE"NC110/150/200 Nurse Call System Paging is an ancillary method of call annunciation,and is not intended (requires NC375 Transmitter Interface) to replace the primary annunciation provided by the nurse call system. -or- Tek-CARE"500 Wireless Emergency Call System www.tektone.com 277 Industrial Park Road • Franklin, NC 28734 • Phone(828)524-9967 • Fax(828)524-9968 Email:tektone@tektone.net • Technical Assistance Email:teksupt@tektone.net TekTonel's quality system is registered by UL®to the ISO 9001:2000 standard.(File#A10766.) re k7�onlF IL734 NC399P Alphanumeric Pager Section E CommtechWireless 7900 Rev. 5-04/2009 --- Specification Sheet FEATURES The NC399P alphanumeric pager is a radio pager receiver with a large 2-line display, and is designed for use with TekToneO's Tek-CARE"'500 Wireless Emergency Call System,andTekTone'sTek-CARE�400,NC300H,NC200, ......... NCI 50 and NCI 10 Nurse Call Systems.The pager stores up to 60 messages. Messages may be selectively deleted or locked into memory.Messages not locked into memory are automatically deleted as new messages arrive(beyond the 60 message limit),with the oldest messages being deleted first.The NC399P may be configured for annunciation via vibration or audible tones, and has one alarm for daily NC399P annunciation. It can be programmed to turn on and off at preset times each day. The NC399P has been pre-programmed to receive call information from TekTone systems.Its CAP code may be reprogrammed in the field. O Alphanumeric 2-line backlit display Easy to use large 4-button design • Configurable for audible or vibration alerts • Field programmable • Includes holster belt clip and safety cord ARCHITECTS' AND ENGINEERS' SPECIFICATION SPECIFICATIONS The alphanumeric pager shall be a TekTone"NC399P,or Dimensions: Height: 1.9" (49 mm) approved equal.It shall have a large two-line display and without holster belt clip shall be capable of storing up to 60 messages. The unit Width: 2.7 (70 mm) shall have a four-button design for ease of operation and Depth: 0.7 (19 mm) shall provide a choice of tone and vibrate modes for page Construction: Electronic components surfacemounted annunciation.A holster belt clip shall be provided with to PCBenclosed in ABS plastic housing each unit. Operating Freq.: 457.550 Mhz The pager shall be pre-programmed to receive patient call Power supply: 1.5 vDC(1 AA cell) information from TekTonel"s Tek-CARE*500 Wireless Emergency Call System or TekTone's Tek-CARE0400, APPLICABLE SYSTEMS NC30011,NC200,NC150 orNCI 10 Nurse Call System, via TekTonell's NC365/A/AT or NC366A/AT Tek-CARE*500 Wireless Emergency Call System Transmitter/Control Units.The pager's CAP code shall Tek-CARE'400,NC300111,NC200,NC150,NCI 10 be reprogrammable in the field. Alphanumeric patient Nurse call systems call information shall be displayed as generated by the NC365/A/AT Transmitter/Control Unit emergency or nurse call system and the pager shall NC366A/AT Transmitter/Control Unit generate annunciation by sound or vibration. NC375 Transmitter Interface Paging is an ancillary method of call annunciation,and is not intended to replace the primary annunciation provided by the nurse call system. www.tektone.com 277 Industrial Park Road - Franklin, NC 28734 - Phone(828)524-9967 - Fax(828)524-9968 Email:tektone@tektone.net - Technical Assistance Email:teksupt@tektone.net TekTonel's quality system is registered by UL®to the ISO 9001:2000 standard. (File#A10766.) rek o` IL559 ' NC150R Master Station Panel Section D Specification Sheet Rev. 8 -03/2008 for Tek-SAFE'" Area of Rescue Assistance System FEATURES The Tek-SAFE' NC150R Area of Rescue Assistance a System provides communication between areas of rescue ( assistance(in protected stairwells)and the building lobby. E Calls are indicated at the NC150R master station by both visual and audible signals. The master station also has talk,call and selectorbuttons fortwo-way communication with up to eight IR15OSS series remote call stations. (Larger masters are available.) Meets ADA requirements (check local codes for additional requirements) • Audible and visual annunciation • Voice communication and monitoring • Push button operation Sensitive speaker/microphone Solid-state circuitry.. SPECIFICATIONS Dimensions: Height: 13.25" (337 mm) -- Width: 6.25" (159 mm) - Depth: 4.25" (108 mm) Housing Cutout: Height: 11.625" (295 mm) Width: 4.4375" (113 mm) Construction: Rugged extruded aluminum NC15OR Connections: Screw terminals REQUIRED COMPONENTS ARCHITECTS' AND ENGINEERS' SPECIFICATION NC150R Master Station Panel OH150 Flush Mount Housing Area of rescue assistance system shall be TekToner IR15OSS series Remote Call Stations NC150R Tek-SAFE ° or approved equal. It shall have IH151NK Junction box with: push button controlled circuits and indicator lights for talk • PK151 A Power&Control Unit and cal I functions.The master station shall include controls, • SS106 Transfonner,24 VAC amplifier,selector modules,test button,panel and frame, and shall provide visual and audible indication when calls are placed.The system shall allow for connection of eight IR150SS series Remote Call Stations,and shall provide a two-way audio communication path to each call station (when properly selected). www.tektone.NET 277 Industrial Park Road • Franklin, NC 28734 • Phone(828)524-9967 • Fax(828)524-9968 Email:tektone@tektone.net • Technical Assistance Email:teksupt@tektone.net TekTonel"s quality system is registered by ULI to the ISO 9001:2000 standard.(File#A10766.) Tek o u IL765 ' IR15OSS, IR15OSS/S Section D f. Remote Call Stations Rev.4-11/2008 Specification Sheet FEATURES Used withTekTone"sTek-SAFE`"NC150RAreaofRescue Assistance System,IR15OSS and IR150SS/S Remote Call Stations provide efficient communication between areas of rescue assistance(in protected stairwells)and the building lobby. rR IR 150SS and IR150SS/S Remote Call Stations are located i n * ' areas of rescue assistance to provide two-way hands-free communication to a central location from which help may besummoned.Calls are placed by pressing a large,2.36"(60 imm)mushroom-style momentary push button.Solid state indicators on the panel indicate when a call has been placed and when the intercom is in use. • Push button calling via large mushroom-style button IR15OSS flush mount Call-placed indicator (IR150SS/S surface mount also available) Audio-on indicator • Cancel button • Sensitive speaker/microphone Attractive and durable stainless steel panel Weather resistant when properly installed SPECIFICATIONS ARCHITECTS' AND ENGINEERS' SPECIFICATION Dimensions: Height: 5" (127 mm) Width: 11.2" (284 mm) The remote call station shall be TekTone"'s IR15OSS, Depth: 1.75" (45 mm) IR150SS/S, or approved equal. The remote call station Projects: 1.5"(38 mm)above mounting shall provide a call-placement indicator,a 2.36"(60 mm) surface (IR15OSS) mushroom-style call push button,a cancel button and an Projects:3.5"(89 mm)above mounting audio-on indicator.The station shall also include a 3.5" surface (IR150SS/S) Mylar"' speakerhnicrophone with voice response. The Construction: Durable stainless steel panel Finish: Brushed stainless remote call station electronics shall be mounted on a durable brushed stainless steel panel. Connections shall Speaker: 3.2.3 (60 be made via screw terminals.The station shall be weather Button: 6-screw w t rmi diameter resistant. Connections: 6-screw terminal block Housing: TekTone"'OH600orequalforIR150SS; none required for IR15OSS/S REQUIRED COMPONENTS Tek-SAFE- Area of Rescue Assistance System www.tektone.NET 277 Industrial Park Road • Franklin, NC 28734 • Phone(828)524-9967 • Fax(828)524-9968 Email: tektone@tektone.net • Technical Assistance Email: teksupt@tektone.net TekTone'"s quality system is registered by UL®to the ISO 9001:2000 standard.(File#A10766.) Fire Alarm Panel DESIGN CRITERIA Main Lobby obb DESIGNED PER IFC - 2006 EDITION/WAC 51-54 DESIGNED PER WAC 388-78A-2930 Power Expansion Panel 11 Power Expansion Panel I TO AC INSTALLED PER NFPA 72 - 2007 EDITION INSTALLED PER NFPA 70 - 2005 EDITION/WAC 296-46B 2nd Fir Electrical 2nd Fir Electrical 5820 �ACP '@o� EXISTING FACILITY: s11 R-4, LC-7, A-3 OCCUPANCIES o II - Win MW 7F 1 0 ❑C ® ' • 58,473 SQ. FT. SPRINKLER SYSTEM -T • 0 0 SM wrtx v� FSouth Win South Win ' _ • • g g .^ South Wing NEW ADDITION: ® ® © ® �� R-2 OCCUPANCY r�1 ,� 30,365 SQ. FT. SPRINKLER SYSTEM n ?irY BO � � 3 . Key �r AUTOMATIC FIRE DETECTION: 002 001 fA IN THE NEW ADDITION CORRIDORS WHERE EXISTS 97' 0003000000 "� BEAMS RUNNING PERPINDICULAR TO CORRIDOR LENGTH, NO REDUCTION OF SPACING IS PLANNED TM ElpTo L Loop To phone lines Grpund st�ltt ° z F FROM PRESCRIPTIVE REQUIREMENT (30' AS PER re a soc e '. ,.. s 000 0 000000000000000000000 J0 � ' 72-A.5.7.3.2.3.1 AS PERMITTED BY 72-A.5.7.3.2.4.2 3 0?1d�. . J D. o�54 23i22�,� 1918A7B 15X 1131 117 a o 6 o X Center Win Center Wing R Y RELAY 2 A6IM �6� D , I/O 2 I/O 3 4 I/O 5 I/O 6ft- 9 Center Wing - MIN o F WORK 3 3 � $ SCOPE O O 3 x ; North Win g : n North Wing N Ut N N N to �„'� ` Ga to COMMERCIAL ALARM & DETECTION (CAD)WILL PROVIDE A FULLY !J U U O q s 3 Q U 6a FUNCTIONAL NEW ADDRESSABLE FIRE ALARM SYSTEM IN BOTH THE Q 04 GI "0 `� KS � � EXISTING FACILITY AND THE NEW ADDITION. THIS SYSTEM WILL lL z x (A M E M W 4 p - 2nd F I Floor r Fire ACCOMPLISH SITE EVACUATION, MANUAL ALARM CAPABILITY AND Ir �` ` = 7, 1 st Floor Fire 3rd Floor Fire SPRINKLER SUPERVISORY SERVICE. ALSO PROVIDED WILL BE Q CJ ty AUTOMATIC FIRE DETECTION IN COMMON AREAS AND CORRIDORS. p 0 0 ' �' W N '5 0 � � Zone Layout Zone Layout Zone Layout THE EXISTING FIRE ALARM SYSTEM WILL BE REMOVED AND ALL U Z .p U. tY � ul a V) FUNCTIONALITY OF THIS SYSTEM WILL BE REPLACED OR EXCEEDED Er 10 y, a 0 0 G. � R, M 6 U BY THE NEW SYSTEM. SYSTEM DOWN TIME WILL BE PLANNED DURING LU BUSINESS HOURS WHEN FACILITY IS FULLY STAFFED AND CAD _J LL pq tb tii 4 TECHNICIANS ARE ON SITE. DOWN TIME WILL BE CAREFULLY U �Y tN 4� CORDINATED WITH FACILITY MANAGEMENT AND THE ANACORTES FIRE Q " ry Ry C 1y k! DEPARTMENT. _ kA ADDITIONAL LOW VOLTAGE SYSTEMS TO BE INSTALLED BY CAD: U E C!} WIRELESS EMERGENCY CALL SYSTEM (ENTIRE FACILITY). EACH 5$ RESIDENT WILL BE GIVEN A MOBILE CALL PENDANT. BATHROOMS WILL BE PROVIDED WITH PULL CORD CALL STATIONS. ADDITIONALLY EACH Annunciator 2nd SLC Expander Board UNIT WILL BE PROVIDED WITH A CALL STATION TO BE LOCATED PER Power Expansion Panel III THE RESIDENTS NEED AND OR PREFERNECE. 'Tat FirWiWing �IOr � t Fir 1� AREA OF RECUE ASSITANCE (NEW ADDITION ONLY) = -- -T F GENERAL NE ALANI NNRMT% — • F_�sRu aaICR -- C7 EXCLUSIONS 0 C - � c sTSIEII sILENCE mTEM PaMER - Station ,,� 031 MODEL 5815XL I i — I - � � 0 2 © am.� Remote Station #2: i Master station. Remote Statio n #1 1. 110VAC DEDICATED CIRCUIT TO FACP AND AUX POWER SUPPLIES. IR 150SS NC 150R IR 150SS -I 2. TWO PHONE LINES TO FACE, ONE DEDICATED, ONE SHARED WITH ooa © o ® SeUS Housing: ©H600 Housing: CJH150 -� Horsing: C? !600 -- FACILITY. SLC Out SLC In L T �— — ,'� 3. ALL CONDUIT, BOTH ABOVE AND BELOW GROUND. 003 Annunciator grid jJ II SC- S� SC S+ 22/ // f ! 4. ALL LOCAL ONLY 110VAC MULTI-STATION SMOKE ALARMS. 0 (_) y 22 2 Floor Ctr Wing Hail - - Shielded 1 NOTE: Shielded -- _ EXISTING NO WORK FIRE ALARM DEVICES SHOWN DIM. ALL NEW FIRE UU JLJ I GENERAL AI ��NxM1a �� " Stranded _ �. Stranded ALARM DEVICES SHOWN BOLD. I-,GEE I] -L _- t� srsIEN mouBE �' ®� G SYSTEM SILENCE _____._ -- ®® "ITS • II �;�� 18/2 = a Q Remote Station #3. J i Remote Station # 4: E ® o 0 0 �' IR 15OSS Shielded 18/2 ( IR 150SS to AGE © ® ® d 16 Housing- OH600 I Stranded 1 Shielded Housing. OH600 a ® ( g -- --- - - -- Stranded \ __ v Power & Control: oos - I H 151 N K ---- --- -- -- - - 3 3 Annunciator 'I st � z z z Floor N Wing Fall IL U. U. °a = a+ I..'GENERAL AURM NINE MANI HNNOTM _ k- C F'6GPOMSERY fy r F-SYSEBI SIYU SUME ©2 0 o Area of Rescue Assitance Wiring FIRE ALARM SYSTEM RISER/PANEL DETAIL NOTES: SIGNALING LINE CIRCUIT ONE WAY LOOP LENGTH NOT TO EXCEED 3900 FEET (18 AWG). TOTAL COMBINED LOOPS (INCLUDING T-TAPS) NOT TO EXCEED 40,000 FEET FA- 1 COVER CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL_ CANDELA MOUNTING QTY AFT ABOVE FINISHED F COMMERCIAL ALARM & DETECTION INC. SEC NO. DATE BY REASON FOR REVISION �❑ SLC SIGNALING LINE CIRCUIT 1-4 C 18 AWG `PLR OPEN OR COMBINATION OPEN AND RACEWAY FAC SILENT KNIGHT CONTROL PANEL 5820XL 72" TO TOP 1 AWG AMERICAN WIRE GAUGE 17199 BENNETT ROAD C CEILING MOUNT DEVICE Exxel Pacific NAC NOTIFICATION APPLIANCE CIRCUIT 1-4 C 416 AWG `PLR OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK58BOR 60' TO TOP 3 W WALL MOUNT DEVICE MT VERNON, WA 98273 EN EXISTING DEVICE LICENSE #COMMEA1948LO AUX AU%ILLIARY POWER CIRCUIT 1-4 C 16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REQUIRED 3 323 Telegraph Rd I� REL RELOCATE DEVICE SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY F SILENT KNIGHT MANUAL PULL STATION SKPULLDA 48" TO TOP 26 WE WEATHER PROOF DEVICE PHONE (360) 848-1533 FAX: (360) 848-1072 s SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO CEIDING 105 FACE FIRE ALARM CONTROL PANEL Bellingham Wa 98226 ANN ANNUNCIATOR NURSE CALL DEVICE LEGEND SYSTEM SENSOR HORNSTROBE SYS-P2R SHOW PER DENSE 84" TO TOP 14 AUX AUX ILLIARY POWERS PPLY SYSTEM SENSOR STROBE SYS-SR SHOW PER DENSE 84" TO TOP 3 Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING QTY SYSTEM SENSOR MINI HORN SYS-MHR N/A 84" TO TOP 31 PROJECT MANAGER : T.J. Mellema MAIN TEKTONE MSTR STATION COMP, WIRELSS RCVR NC501A, NC510 NC150R 1 SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REWIRED 2 PHONE : 360-734-2872 Low Voltage Systems ❑Nc TEKTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC150R 93 ET SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAX :360-671-7616 13000 Ave ® TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR 111 N/A SLC J-BOX N/A CEILING SUPERINTENDENT : Casey Anacortes, Wa 98221 + Nc TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC150R 92 RR SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REQUIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE :360-815-7223 ® TEKTONE SIGNAL REPEATER NC511 NC15OR 3 Wheelock Existing HS (shown dim) MIZ-24-LSM 15/is DESIGNER DATE SHEET JOB NO. Department of Labor& Industries FAX PGR TEKTONE PAGER SYSTEM NC366 NC150R 1 MSTR TEKTONE MASTER STATION NC15OR 60" TO CTR 1 p KEY PLAN CHAD 1Y05/10 1 OF 8 9000156,157,221 AOR TEKTONE AREA OF RESCUE STATION IR15OSS 48' TO TOP 4 City of Anacortes - G :,jest!lame Chandler Square _-- Saandbp Hours <'J Project flame Chandler Square Stand;'^ HOtirS 23 �, ' , .- - ' .�1>Pr,;zc: 3F,zs• ---- - Project fQarcre Chardlar =s,uRr �tandD;i Hours -_.-`9---� F G,ect !-0an:e Jhandle, S'-L.a .Standby Hcu!s 2-i F'n)ert lC �y lrrp1s5 +farm L1u1s� - Froja_t I^ GrJ 10t f .::)arm Mills -- —i = �--_ J - - �:1 ! Derat:n Factcn 1 2 p - 1 '--- -- Prcjert IC. 9COU1_^ �� A!arnl tAn > �J Pr+aect IC. S't:IrJotcri Aiam,. GLns. ^=I Fr9,a sd B, ..had re.alec 8 !.harl FreratnTO Factor. 1 2 Cate 1 122010 nN3r.e C'fDo an ino Prepared B had Defining Factor 2 Pre arced B - Chad Deratino Factor 1 �, Thlas ot,.r> 0 C++ate. 1:1. 21;14 �Ita¢eT C "inlmy t% - --- ---- - ,a Cate 1,taat)1f7 :oliarlc Drip '.can in0 <.. TI e..hdd � � — - - Date 171a`:2 GI'tp 1a1rLn0 TI. eshcl! IJ—D Pare-hold Panel ,C H,.9:(L f,i,.del :320!1_Add Fry A(a+,n C.-p L:1 Pa1IEI Max II.v.. .,unent 3 U A; Gs ,�. - v,,,- Pane! IC: ��d961 MCIP1. b491i Pcv,-erExpander Ma:, '4A'C Cuiren!- 3 0 Anlps _ Lo:atlun LatihY offs 24 DC Ma , Panel DLlrrenl + 0�?nlps Panel ID 53(tg II Model _4'%PIT. er Expander Iv1a; Hl4c Current 3 0 A.n.-,j:!s ! i -,. a„ , - ^! ,,,, 2 ....: Fane, IC 4 ,6 III rUicuw d,.. P„•e! O end, Location 2nd Fit Electrical FGo,n `�,.It3 2-t 'dC:. hfa.�: Pane( Current b G xtnes r ----� C..pan_!er G a> I+ .. c,.ur�, . Location 2nd F!i Eleft,ical Rooni b:,;ts 29 `JCC (ace : Pane! Cun?nl S 0 Anq>s LOratic List F =n. Hall 0I!o Ca JCC as Fans, current E 0 A I:'.a Carr nt Cra:, ;Inc�,rr5 Ohms `er Lengthtfti HttU3i '✓Clto 1! C _ _._._.- -_ I 0k!# :!mutt 1131ne t a. FD„ Stanch„ Alarm R T e 1010 Ft Ones`.a:' Ohms EOL .'_L-VFent Cra:a "'Fe A':"c`G Ghn-Is Per Len thift! A-lual 'o31ts -- -- ----- - - - -- - - 't" ----- ------- Part.# Dessn tion :t_ _ g �' co OF, Current Graa.i ,.:ire A'f�:G Ohrns Pet Lenathift( Actual `!olts n r. c '�''G e � + f r It^ 5320XL .,62+.�.L C'TRL Panel 1 0 21. 0 3a5 P Standby' 4tann & 1 .^ce 1000 Ft. One..'.`a... llhn-ts EQL r Part"# Descri.tlon vt;. - ��,: :o0rap - -, r ,t,. .�,.ent Dra,.o Ire:... _ Ghnls Per L_ngtltifts H.cua. l c,.� u ` f ta,db•r :+farm &Ty lie 1000 Ft Ore-.:a•., Ohn1s EOL Fart.# L'es�Itp-Ion f J e ua, "aC'rap - -____-- _ - -- ---___--- _-- __. _ . . ._ Stan Ih Afann &T;•�e 1 J00 Ft n a Yu11s E��L SK Photo Photo T 105 U U:3 a 026' / �4 6 -1cr+i Pt r Module 1 0 04�1 0 160 _ --'-- -- -_.-- '^.!4 foil !1 OOO 00100 ! ) O :49F .i-.i .1L U Ihrj. -- ----- — r„+r' #7 ZI d Fir'=� ':`:'!tt "I'd ... 4 t *3�i - ^i 17 9f lc. F•'o °� '43r� P: r rlcldule '! v uJU I lf. —1 .,r o r F`t•:r r,lcdtde 1 r11? t 1 ..� .._____ "19- e Ll7!U U o7= .I Jz ,. — -L_. _ ! —' L r L;,;.!ill '.'.'Inc, p - '�s:c r2 'i�tii "i ? 4-. Il c- �t.. neat Heat-HT G UUfi n,113G ----- --'--- --- --- [.r_._ dTci FIr „aster_tt�^, c`'a 0_JUC! 1 OL_�I^! 4 7< --_ - =41 _ 1,_ 1< o_ fln;C�'I 1st lapr IJ ';'r9nQ ='g. Ci UUO 0667 tc`>o.;:' i�} 4.02 s50 [.S1 12 52 J 20°0 -_. q:. U . . �' Y14C 48 2nd Fir JY, `.''.'III. ':.y. O c00 1 U24 ,E - (^ •t IJ2 N30 1 61 17 r9 Y, 12 U1�r, , .£e dl. C-' - - -_—'_ �^ —_—°-.- L7J 2 0 1:1 11 U1 e ryo .,r•. Heat R.H UUU U.uVO -- - '— I1AC=1"2 3r,1 Fir ,oath .; f n 3.1• A sec 4 U< 2riJ 1 1 E , 1 - .� -i+lily -.r. �..-- 1 t+ (t o ;,n � I�i` f nI !. , .., _, r r .. 1 ill 7 c "cI h' ^00 !. 1 if, 1 i- Sh Brim. Eean 0d.� . t00 1. .,. . . Lobb, -m1nT,c.1s 6. L .-L :.Z Gr •_I 4 .2 L.L 1.,1 � .: ,�.0 :+, ,�� _ - _ - - 2 F OU 70 � 1' �-i ._ , - " -� 4 d Floor t1 ,in' fy C 0t:.i O :i..� 1 4 < ,_'0 )c 1 ra u : Ct, r fdr?C+13 J'T1 1'Ir l.eI11e1'.)In:j -0ry'^.: 0;j(`i!1 Q ,[ -�_C:U I 4 i![ SOU -+ da 1' q5 11 d1�-a Q� 4 -t2 io g3ay Duct 0 0OV J.000 i5:` 1 �r r,,,•; „•;: c' '. 'I '+U =,'> 'tin y. . 7 ., r;,o. _ . Il .., . 0 _1dFl .. ..ul & LC.J 1_E4 ��� 4.fJ2 S.J .. 11 7; ': talco at^z ¢ f, r rlri I ' f1r" »i r Ff �-- � ,�0 � - sI% climate ,1 UCO 0.0+)9 li 14 lid F es `::"lino cfS. Gi 1 903 -- - � +}2 F50 2 01 10 6- 1;; 77"-c _ r1 i;n0 .��- -.. I fI .4 "9 0.U00 Imo) 402 UOU 2040 i Total 3tandh; i:urgent IArn s' ,0 04) S 35' Totai 41arn1 T;.Irrent iAn17s! T,;ta! :tandb':� CUfrtnt 1.am>s'r 0C40 5,2240 Total Alarm �Cuirknt i4ni's! c r :. : �! 3... wJ 4K Control 0 i100 0 OUO Total ._tanat- _un'_n-+' n,:"s; c -w0 1 90_ Total .arm Currerrt iAnT psl -,.----- - -G------ - rS�l' 1 1 i � S.tancf Time In Hours 24 0 603 Alarm Tame In tainutes 5U ' 4,lirs^ 5 a h',:T; -r !n H z Iro ,.1 i� '^9 alarm Time in Painutes: tU in f.l+ns'. ,. r, - :a _r. C,nbot _ _ -u( ) 4J0 _tard, n e Hours L LD. StandbdTrme In Hoots <4 0 033 ntarnl .,+ue In t,,.IncJes + G'?� ,l.liosY Sk: t"lmtttor. Mieim-,Ii 4 0,102 U 015 Total Stanub,,• AH Re uued !) 950 0 44' Total Afann AH Re used Tota! Stencil,, .AH Required 0 960 0 137 Total Alann.AH Reruoed A a 9r O c, 4IL � / - - Total ota tdh H Re, utr.d 0 ._ 0 :-» Total rlar.n . . Reruited SK IAonitur-2 U 000 0 rJ00 TGtat Cmi,bwad A.H Requil-ed 1.41 Command Shortcuts Total Combined AH Feauired 1 40 Command Shortcuts TotalCou'tir :! �.H Re< aired 2 Command Shortcuts 5v, tiorlror10 IT !MCI 0000 •V `� SF: PUII-SA. PuN-D2. 2fi U U1U 0 01U M ti 1� B'r The Deratinq;Factor I LO Gluttlplr B, The Oe,abna Factor _ 1 20 __ �L?ultl I B The Ce atinn Fa-tar 120 -- - ----- -- - - Print Fa'E - �_--- --- - Print Pa ----- �:- L-----g=-- r t:i6 i n .r rig,�H^ +„ R r ;i .,annqurai Lirc 46 G„nf+ me Clrcuris 4e -- ---- p �I, R_'I - i, a Jr3 O Uu.r `� T I u Batt- ouie e_t led 1.69 ;. Wimmun• Bitter, An,:Hour, Re uirad 1.68 9 :� ( lAiniTium Fatter:Am-Hnars Recuifad 1.35 .`onCLius Iuuts ( Print Page ._. _.- -- Arn-HCursA:.ailable. 7.00 AmpHrwsA:ailab!a 7.00 51� Rala� -5 0000 0-000 `. ,x AmpHcurs:;,•ailable 7.00 p SK Zone 0 000 0 000 SK -one h 0 000 0 000 SK Iscfalor 1,10dule CI )00 0900 SS822461 oiatw Base 1 tioo0 0 OOQ Cf:t; Cr.,ECM: SS65018HIT Sounder Base 1)000 0 000 �. Project Name. Chandler Situate Project ID: 90001,5r3 _ Project flame ;'handler Squar Project ID 900L+'Sh SSE3224RB Rsla+Base U 000 0 000 Project flame: Chandlet Squat Project ID: 900i 1 b Chad Date: 1:12,2010 Prepared By: road Date; 1,I 2110 SSRT4151 Fa;neticRe!T1r. Test_ 0OOO 0r100 f Prepared.By: - - .. -. _ --_-- -- Prepared By. Chad Date:'1 12.2n19 SSRTSl:IK.EY Ke-Ach':aced Test 0 000 0 000 . . . �SSRA19UZ Remote LED 0 000 0 000 ` • - 'N A^'�1 i r ., t Gumber II _ Faatel G �4 Bill Ckt f lunlre-I NAC #1 Palle! Ill c,4`^5 1 „ _ 8'„�L SLG Leap E:.pander Q C5c 0 05 / Ckt NurvLer t•1.�.� 11 Parlel !. b49r It "Ft I jam 1..t Firor 11 . mg Use ra, r., -ace c,- u; --- -- r--- -- --- -.. 5060 L•.,D Rernrt-Anntlnc 3 0 060 C+A75 E Ckt f Jame 2nd Fir SE .`An^ " Use '.., `• a..,r I CIO [lame 2nd Fir Center . ,mtJ Use o-.-, __wr vec,Gx,uic Currant Drac, Esch ':Current Gras,;Total u r` , c �-, 5824 Seria6:ParallPl Hodule 0 000 u nfj0 A OF% De'.ice - -- -----_----- r,. Current Dra>,,• Each Current Dfa,t Total Current Drw;: Each Current Dra„Total stan.ih•., Alain _ Starldn, Alarm _ - ---- 549r; Fcaer Expander 3 u30 0.030 Dt, e n_e Standl.>• Alarm StanJS,; Alarm Clt; Ge,r e s . e .•., ( 0 000 u 014 I) 0011 n 112 _ _. - - - ,,.. 0 000 0 0UU ,l �� __ Ste - --- --- ------ --- -- - n,b • la tan;lb,.; err ._.L Pc _ E,.ander 7 *~ ->_5 z stry cr ,._; : 0.000 Of.127 0 000 0.6689 3 �.+ , 2^ 000 _ 5 _,e _e-sc „o.", t D .5-_d; 0 000 O OG0 +i n00 n 31G 65"4 LED 1:nnwTclat r 4,31 OJ00 n.00U _... `- t"ACT C to CO. 'i. Eti� ycr:„xs; 0 f 0 10Ui \ ascC G 00v 0 OOO n p00 0 ]00L e n 000 0 U00 L r 4 „n 5 n.e'` 5 O 0 O I p O r� - � - 10 0 i: 6U U 132 o6c 3 LED Amm�tct2 ar r3G' 0.uu0 O.CrjO ;' - + I G 060 0 OOrI G' . '!.n`:'t.DUE .':f. �I [ [ 5-"1 Module 0 Or - r_. !)CO \ cm,, w o i)fl0 0.000 0 GOO 0-000: - 000 0 0}3 0 090 0 C, !. of LED D ,er - [ "''d _ Ct rJOl7 0 G9C 0 000 0 Ut10 C00 -✓j s -.E .E .^.r - - r s333 Rela", food 10 0 000 a G00 _ ..ed U.Ooo o 000 0.000 0 Roo - Ed -1 1}"0u0 Q `GOO O.ti90 10 009 PGf bPG 41 Dow Hldi s#1 c'g.> C. 000 O00fl .A S`.!, _ 4,02 0.00 20 40 0 OU�V .. _.... -. 6 00U '- <fielum To flare' Edit Deice Database � Totals' 0 U00 0 fi57 � Li 00p U Ot]0 0 000 t1 OriQ PGT,1_Hn#2 Dccr Hid 72 C% o LIDO 0 0901 Clc 4 02 h 00 20,40 CI OOyo �_ ,. . •a -: Totals `:0 000 0,889 < Return To Nlaut Totals 0I000 1 016 P!,1�I�r��T3 tsi FIr-3Outh .':+ur:i c1 : p. �•nC 2032I `--='0 !,'J a 02 2orJ tut 1G.?Z a+^1�z Fi-tam To tplatn Edit Cezice Latabaae Edit Database PG,M-L'0 #4 1st FIr Center:"•:inn ;lc :. C'000 11369 r,, .'.:c �' 4 02 30U 2 41 1'J 25 10 ;1°•c :JNt llmn6er: lip.:: 2 Panel 1D 5495 III FGt., 'O#5 ON 0 000 0 000 .6:p;c E 4 1)2 0 00 :.f,.40 020Ph _ -.. .. Ckt (lame Zrd Floor tl :;fing U..a i<:, � � . ,apa'C ,, -'-----� - ---- —..-- ------ C+ S>dq l „ht...fluillb'er 11AC d02.. Pane C c-t 'f,• II Turret t Cra.� Each Lurrent C,rarrT.^,cal -- -- F of l l'0 Z1,, -..._._ :.tg... n: .n hoff. t o : IT _0 4Q 0 '�00. '..Kt f}tllYlt:ei f,AG n18 Fane i _ �2C/ De.I4e .. _ . .r00 0 riU(1 - ,_f_ J 02 0 1. 2 - -. ,. p z, r: .! _ StanSb•" Aiaml 8tandb•• Alarm TctalSaanft: , GurentiAnl^s? 0403 3.322 :TotaiA;aml `urrenttA.m.s+ .Cirt flame 2ndF!rS.. ''.tng U.eI�'- ,, �p:" �l •�k,. ,Iam. ._:t! Flr.-,..uth ,,,� _-.. _.- --,:, t r_ :.,_ 5 ter. L�:.,. c. ,dt,•.Time I 'curs 24 r i^3 Alum Time In I,inns . ? t5 rdln - _ ..-..a .., n Hours _ J.Ja , e 1 L e.. 6t ... - - C:r.t,°Ent Dfa>; E2C1i Current visas* Tien( n � �LnenY C'•ra : Each 11 s o , ',:. � 0..0+)0 0013 rj,y}0 U iai ..anent D13rt.Total _F .;:. ,., ,.. ,.,-: _. .5.a ,}ir01) I) 01;9 0 C!cU 0 190 Total sLan:fbi A«H r^en 0,o r A _ Qt.,' Ce,Ice _ -S ..i�. .. . . _ E'e,te. _ ". 5'andI,, Alarm--- standb,: Alarm 3 _ uic+:•d 9 �:a u-<-4 ata� .!arm H Re tNred .Standb'. 41arnl .Standb`' N.larni T• t C` - e H u ..t n 9r, - 1 ..... r ... .c•. `:e'..•.. '.E .5 O IIOO ,).Ij V:� {) t1(tt1 U i+;l: .Uta .o!r:bin.J An R due.. 3 a. Command Shortcuts ' �x ...•c ae-_ci (. .1 ("ii' i 27 1 ir' .;• 1 - _ .c<_� ,.P -zr l� 99U0 0127 0 U00 1 3G7 i-i 1< _ `` L� L. IOC 1 24 to l'11i1 j 1-4 li oo 0 li4 . . - - _ - sec U out) _ LlttR:ci; E. The C•elahrK. Factor 120 ". o OOO 0 000 0 000 0 GOO J '3 9Qtj 0 L100 U.OWU 4 ..tbn-, Se �.n „!„q � M- . rn 00 � .,^rt n 'I' ? Spa r - t Co+iGOuie'sn:mts PrintPa3a s.' _.. - '"') 1 "let.lama..IF2-P„�H�.L_.huf;e111.-d, U .1_t. u ,�_.. . IILO LL3 :,tinin um. Batta:; rnHuurs Pe wlec 11.96 - 0 OOn rt 000 0.000 9 Oe0 I A00 C 000 0.0_. J _.,, - e -_ - _. . `�' - - c Return To hiarri: Edit Lie,lce Database Totals 0 00t 0 ,,0 K.n+pHcurs A:adaLle ' 12.OU ed_. __. __._. _ - -. _ C+ P( ' it t' fill r'fih�tt - - - T T n r 0-}0U U OUC, p Tun 04+5 .. ..zd ,� U asp Ij 000 0 O06 0 OOu 4 000 0 00131 0 000 0 OU;� _ Totats 0 000 1 397 '-kt (lumber IL,C-3 Panel 10 549+r 11t Totals - C+ 000 1 a24 < Return To Msill Edit De%:ice Database Protect Elarne. t,haudler Squata - Protect I0.;9u_tfO1:IJ _ Return To 1.1n Edit Da,>.�a Database ,.�.. . - 'Cht Game- 3'd Floor N ',':gn;j Use, '�c.f-�.� �:v c�c," I'J .. Prepared BY:''C ad Date: t'1' _010 f P _ ° ut . Device wrest Dra. Each Gun n, ..a. Total _. -.. Standb• A.larnl St.,ndh,. Alarm CYt flambe( lla( -13 Panel ID a4ctr., II ,, . _. _ . . ._. -. -1,I't ilunther tlaC 4. _ . . . . Papal lC o45'6 ! .. -. _ .. ... _. - a '�-- � ,rtr i .+- __:2 - ..: ". ..... _. �Si OC+t)0 0U14 fj f00 U16on Ckt r umber Pri PID II Panel ID ob20h1 c_ � J kt htam_. _rJr11 .,_nt_I ,.ur l.s� ,cam< ..c:i,app ..-:uo �� .. s * CH flair+e Lcft, Commons Usv. 0..:. .ate rpDv"'....', ,.I. !C _r. - ,E .r's� y:... - itfujU 0.O66 fICOO 01SI3 'Pub rlalre-. Uoot Hldrs..1 I J Use A,,,, , :Grow: � . .Dt G«.vice �urrent ..ra•-; Each Current Dra!+;Total ,e _-1. 0 r10p n ! ! 0 0'i 1 Utfent Gras;Each Lufent. Dra.. Total 5tandb; Alarm StandL. Hlarnl _ 0 CCU -, all Nrm^ T,n1-rr v,uaeot Cra:,, Each. .. lu+ Ent Dra,-,Total t=ty Device .. . ... ,..-_. _ ._._. e_.-.-. r.,:,:.rr I .. 0 UrIO 0 p0u ti OqU 11000 t, e p. al Lo _,tandb� tarn! Standb; Alarm ----- -- _ --- Stand!r, Alarm Standb: lank _ _ __ r- ;;2 _ e.az , es; O 000 0 127 0 000 0?b2 - _ - - *4 QOO 7 70.! 0 OI1Q t' Dl+j I,} .` `a:`_" ca;tr.e"c :c I w:. 0 000 3 127 tJ 000t 1 2' i _ __-_, eu<eC � 0 0u0 0 UOL G +700 0.000 .e,,.. t i 11f 1 f ,I ft r ro 'I -pi,'' 1 1'; c r r iti c Return To Fain Edrt:Ge'^ice Database tot rt 0 0 a5!i 00 .. _-_— - - sE 0 oo1) ..0 000 0 000 J.00c; ,.c,,:SEC .... 0 0' n L Q G u .0u vJLIO Q0U0 3 � C ) L CL u00L ) UJ0 00_J 0 OOit U Ofu 0 d00 0 000 0 3�30 0 000 J 000 0 QGD ^.sex O IC,0o o 1)04 C r}Cl0 O.U00 _.usz'?. __. - .. f� {. 0 0'.10 41JOlr 0.000 10 1300 _. _ _} - C 000 O.UIiG f,Pt Uu1nL•ei t h>iC#! Pan?{IC' 495 III ... -. _ U 000 Q 000 - rt.000 LI 000 j TOCat6 0000'` O 'f2.;. Cl;t tia'n e. _... L --:: U ;n h t �.:� .. I7. c Return To Main Edit Deice Database _'utretrt Dra:,Total Totals 0 000 0 000 '-,an.G Alarm standb• Warm . < Return To Main Edit CJe�lre Datakiasa .. . ,. � Totals 0.000 1 270 , - - ---� rl,t Ga�., Each Return To trlam Edit De.fsa Database ,I,, urn 0 000 C 127 0.000 0 000 ;lht 'Jun-ter F'yLt± 0 E2 _ _Pane11o, 5S20.XL ::Id r,lutntar llAC 13 .. ... ., __.. . . . Panel 1D. 5.198 11 ., ..:.,... .. _ ( 0 00r, O oi1C, Nome Dcr Hl,rs# ! , Ckt (.umber NAC =1!) Panel ID n45tr I Ckt Nellie +rd FIr .' est ":%ma Use O. °;a 3oa . •J � 1 2 USE. :,rx>� F Li - n .....: ,.,. - . ... -. --'----"ter. - ,. O.iirJG LII.UU0 U.OitQ 'J.J9n C'irt t1atne 2nd Fit Use t= - t_ ^ •t Curient Gra., Each anent Dra.,Total C.�.`i „ -n t a Ctv 4 Horns - Temno,s: Lei,., - .Cur nt Cra't. Each uu•ent Cra:;:.Total :: .sn'rg -.w•'�-.--' (.', Qt1 Cesrce - l_....J c u.0 u 00:. !+OLIO O.CI(!rJ landh': Alarm Standb'.; Nafni Standio-v Alarrn Standl•^ —AlanT1 t E. coo: re:3 7t ceri P Cwrent Dra ; Each Current Dra;a Tcta! _ u Do0 0 .1uG �-J 0 u0_1 0 Mo n "lot) 0 000 storldb•; Al alai 4tandh Ala. , :es;' • 1 OOCi 0 12? 0 OOO 1 90 ota --- -- __ -=-- i � rR- 1� ',Z c L ,ter!; CF Return To r,1a+n Edit.Dc Ice Database , T Is 0 U00 0 000 c - ' t . I n 12 -_ ...c ,y..z _ .. .- a 0 Ot)0 0 127 0 000 1 -,24 -` ...... ' 11000 t COC IJ OG+] 0 O00 _ ;>,tse, (� 0 001, U J0+) li 000 r' U}. -e_ Q 0 In O.fJL10 0.J00 LOOQ O.f]Oi: ..^e'-. ) 0!JO U .. _ !11 r,1,1 (GOO lil0+) _.-., - R +' .... _ . -.._ .__.. 3 cG 3 o ).0 uoc o a u+�0 )oQ } uQn o 000 )00 )-. Cl 0 000 0 I0oo o oOil I) c11O 0 000 U 000 0 OOu G 000 U o0o 0.000 0.000 0 OCC+ 00 c Return To Wain Edit Deyt:e Database i Totals '0 000 0 40U - � Totals 0 000 1 906 0 OOrJ 0 0110 < ReulrnTotlam Edit Da,Ice Database _ .- _ : Ratu1T To Main Edit Deice DataCasa Totats '0 000 'LS24 Cut tlunlber PGM-RO#1 Panel D S320XL CKt 'fan,e.'tst Fir Soufii Y':'nTg r 43sa _ ._aopC^wit Jt,. trl! Heins " Temporal Lo,: `uFrent Cray:Each Cur ent DfzrA Total ftA Alarm Standby ,arm - - tat. N VOLTAGE DROP 0 00Q 0 12, 0IJL!b 2 !+=2 SYSTEM BATTERY CALCVLAT14 S & O OOn rt+u+-rut 1n1 000 :)�gtl IJ I}1�15 yl ij�i:J 'J IJtltl sec U o o0+-' o Goo ) MID a 000 The Following are the Existing Notification Circuits Amp Draws as Field Measured: Notification Circuit Schedule: ------ ----- ---- ----- o Llttu_ u t)i — — - Circuit #: < Return To Mini Edit De:,ce Database Totals 0 QUO 2 C132 5820: 5496 I I: _ 3 - list Floor South 2.01 Amps 4 - 1st Floor Center 1 .09 Amps 1 - DH #1 (14 Devices) 11 - 2nd Fir Ctr Wing (8 Devices) " ' ar P f U a Panel 'a<r ' 2 - DH #2 13 Devices 12 - 3rd FIr S Win 11 Devices) 'rlAil ; a t- 7 - 2nd Floor South/East 0 Amps ( ) g ( t tine _w nt rra:f Each C+ rent Dra a. TataJ 8 - 2nd Floor South/West 1 .38 Amps 3 - 1st FIr S Wing (16 Devices) 13 - 3rd FIr Ctr Wing (6 Devices) a,db, ,.1an11 Stanch:r lam 4 - 1st FIr Ctr Wing (7 Devices) 14 - 3rd FIr W Wing (15 Devices) — — 9 - 2nd Floor Lobby 1 .27 Amps n00 J la' UC0 f xC' I 10 - 2nd Floor West 1 .18 Amps 5 - Unused Ue 010E G °' 11 - 2nd Floor Center 1 .6 Amps 6 - Unused 5496 III: ,ter , I)r,u 15 - 1 st Fir N Wing (16 Devices) L.till 4 Cuu 0 OTi! -- 0, _ , U,:) 12 - 3rd Floor South 1 .38 Amps 5496 I: 16 - 2nd FIr N Wing (17 Devices) Retdm To r:lain Edit 0 ,1se Database Totals 0 000 0,�a9 13 - 3rd Floor Center .64 Amps t " p 7 - 2nd FIr SE Wing (7 Devices) 17 - 3rd FIr N Wing (15 Devices) 14 - 3rd Floor West 2.26 Amps 8 - 2nd Fir SW Wing (12 Devices) 9 - Lobby/Commons (10 Devices) * Existing Circuits Shown Dim Existing wiring is 16 gauge zip cord. These circuits will be re-fed from the new FACP & 10 - 2nd FIr W Wing (12 Devices) FA= 1 . 2 Cales equipment. No further work is planned on these existing circuits. 11 CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH COMMERCIAL ALARM & DETECTION INC. CODE FUNCTION DESCRIPTION NEC TYPECABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING OTY AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISIONBE]SLC SIGNALING LINE CIRCUIT 1-4 C 18 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY AWG AMER!CAN WIRE GAUGE FAC SILENT KNIGHT CONTROL PANEL 582O)L 72" TO TOP 1 17199 BENNETT ROAD C WALL MOUNT Exxel Pacific NA NOTIFICATION APPLIANCE CIRCUIT 1-4 C 16 AWG FP OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK58WR 60" TO TOP 3 w wnu MourvT DEVICE MT VERNON, WA 98273 Ex EX DEVICE LICENSE #COMMEAI948L0 AU% AUXIWARY POWER CIRCUIT 1-4 C 6 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SX5496 q5 REWIRED 3 REL RELOCATE DEVICE 323 Telegraph Rd SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY r SILENT KNIGHT MANUAL PULL STATION SKPULLDA 48" TO TOP 26 wP WEATHER PaooP DEVICE s SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO COILING 105 FACP FIRE ALARM CONTROL PANEL Bellingham We 98226 PHONE: (360) 848-1533 FAX: (36U) 848-1072 ANN ANNUNCIATOR NURSE CALL DEVICE LEGEND SYSTEM SENSOR HORNSTROBE SYS-P2R SHOW PER DEVICE 84" To TOP I AUx AUXILLIARY POWER SUPPLY _ SYSTEM SENSOR STROBE SYS-SR SHORN PER DEwCE 84" TO TOP 3 Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING OTY SYSTEM SENSOR MINI HORN SYS-MHR N/A 54" To TOP 31 1 PROJECT MANAGER :T.J. Mellema Low Voltage Systems MAIN TEKTONE MSTR STATION COMP, WIRELSS RCVR NC501A, NG510 NC15OR 1 © SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REWIRED 2 PHONE :360-734-2872 g y 1300 O Ave © TEKTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC15OR 93 ❑T SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAX :360-671-7616 !8 TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR 111 N/A SLC J-BOX N/A CEILING SUPERINTENDENT:Casey Anacortes, Wa 98221 N TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC15OR 92 ® SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REWIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE :360-815-7223 TEKTONE SIGNAL REPEATER NC511 NC15OR 3 Wheelock Existing HS (Mown dim) MIZ-24-LSM 15/75 p DESIGNER DATE SHEET JOB NO. FIGR TEKTONE PAGER SYSTEM NC366 NC150R 1 Mfi TEKTONE MASTER STATION NC150R 60" TO CTR 1 Department of Labor« Industries FAX AOR TEKTONE AREA OF RESCUE STATION IR15OSS 48, To TOP 4 1 1 1 City of Anacortes KEY PLAN CHAD 1 1/05/10 2 OF 8 1 9000156.157,221 jl I j a I I A125 ® ® A126 _ 4`tX] F eX _ .._ - I -'i I I - L I c®5 Multi-Purpose C126 I �07 - - - _ - 0 m DB Corr r Janitor LJ) - s 2 5011 _ I Trash i ° . i ' C123 ® _ +4 Corr I C724 I I -fix _ L,�xl Elev., �I sole 1 124 Aa3 i I i d f � Office y �it Elev�R m Stairs �. Mech� 185 � L I I I I, II S 6e ❑F moll (resident_ I II to AN t — g Tm02+ ,U,s„�, ra e _ ,I _ 7 \\ N'i1NK \ 1 N OOB 125 , t ,Ie141 R �Ele6 �I M _ _ M_; Corr - _ 4t 145 - . ,Its �116 'i1 M5 - 1 M _ tf3�17 ® it O A211 - j A743 - A�45 - 1 I 45it - _ 918 6+I_ t -_ O , I 47 II 1' X =:,C® ICI —� --,'} ,i ® i`I- -� J _.. x I C145i .I� ",: _ � ,1._. L. .,il I �I- _ IUt 1 D it i \, i, � i �� - �F nola - 5 _ ` r7 T: _ 5 ` ®'m021 FQ -- -X r - 15 u � Corr I. I „ r AOR Stairs _ _ Lr g t� ' ��� � II I s 17' 5 Stairs I DH sele`, L _ 9 ;. 110UF-----_. � 111 5: ...,� 115 RR R 5ili I , ' BMOKE*IRE L'J; / !, Tras�) �',. ... i :. ,iS _ "� (mil , it_.'f ` y _.®,. I, j i �_{ �� DAMPERB REt#1r� i 113 ?x � ,'��Q�18V ,t� �J ,I ... I:C142 �I___-___ i �„ A, � C® !, V i �I '.{j :K f ...�,;, IVI@Cf1 �, .._i! �aundr� ,I h j ,I i4 r_ j _, , - , _ .I -__ _ 1 I�I � I U i Ele ec h =` 2it -- , IL �1 c -1� I Y ) L _�..'i1. 1 ii 122 ---- {I 14 {, r i L _1 E , ^I Dos ._ I , 5 .� �I M '. _ --._ I i I - � I Boiler - m019 7 142 i �Ie®2, e® 144� III � r F -- ( -.-_- A Keeping � _ I ) r HOU��Seg I A1®2 /" M M 123 146 i A146 rt I III FIELD VERIFY LOCATION � I -__ L III r OF POET INIDICATOR VALVE Scale : 1/8"=V0EE FA=2 m l 1 ST F L R CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH COMMERCIAL ALARM & DETECTION, INC. CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING CITY AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION ` SLC SIGNALING LINE CIRCUIT 1-4 C 8 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY FAC SILENT KNIGHT CONTROL PANEL 5820XL 72' TO TOP 1 AWG AMERICAN WIRE GAUGE Exxel Pacific 17199 BENNETT ROAD C CEILING MOUNT DEVICE NAC NOTIFICATION APPLIANCE CIRCUIT 1-4 C 16 AWG FP R OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK586IXR 67 TO TOP 3 W WALL MOUNT DEVICE MT VERNON, ME 98273 AUX A XI ARY PO CIRCUIT 1-4 C 6 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REWIRED 3 Ex Exisrlrvc DevlcE 323 Telegraph Rd LICENSE #COMMEAI948L0 REL RELOCATE DEVICE go PHONE: (360) 848-1533 FAX: (360) 848-1072 SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 6 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY i SILENT KNIGHT MANUAL PULL STATION SKPULLDA 48' TO TOP 26 wP WEATHER PROOF DEVICE Bellingham Wa 98226 s SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO CEIUING 105 FACP FIRE ALARM CONTROL PANEL g ANN ANNUNCIATOR NURSE CALL DEVICE LEGEND SYSTEM SENSOR HORNSTROBE sys-P2R sHow PER oEwcE a4' TO TOP 1a AUx AL ILLIARY POWER SUPPLY FD SYSTEM SENSOR STROBE SYS-SR SHONN PER DEMCE 84' TO TOP 3 PROJECT MANAGER :T.J. Mellema Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING CITY M SYSTEM SENSOR MINI HORN SYS-MHR N/A 84' TO TOP 31 Low MAI Voltage Systems N TEKTONE MSTR STATION COMP, WIRELSS RCVR NC501A, NC510 NC15OR 1 © SILENT KNIGHT WATERFLOW SW1TCH MODULE SKMONITOR AS REWIRED 2 PHONE : 360-734-2872 1300 O Ave TEKTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC15OR 93 ❑T SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAx : 360-671-7616 TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR ,I, d N/A SLC J-BOX N/A CEILING SUPERINTENDENT : Casey Anacortes, Wa 98221 xc TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC15OR 92 (] SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REQUIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE :360-815-7223 ® TEKTONE SIGNAL REPEATER NC511 NC15OR 3 g§cj Wheelock Existing HS (shown dim) MIZ-24-LSM 15/75 DESIGNER DATE SHEET JOB NO. PGR TEKTONE PAGER SYSTEM NC366 NC15OR 1 MSTR TEKTONE MASTER STATION NC150R 60' TO CTR 1 Department of Labor& Industries FAx AOR TEKTONE AREA OF RESCUE STATION IR15OS5 KEY PLAN CHAD 1/05/10 3 OF 8 9000156,157,221 48' TO TOP 4 City of Anacortes r ion I J ARo 840e I -. As - - - — - F J I 1 _ -j �� Activities _ - j II, 145 �x - x 3 ( Cl IN C®U_ 149._�: III r T 3 �� �- [ A it House 1 C70B � , Laundry J I I I Laun�i �I 160 -- - _- ��ir © �� 112 ] ® ,1 _ 0__112 3 �\B7- 11 _ �J Corr �._ Lx" �F31 r L�3 L �r .. -- - ----- Nc 146- 1 �m007��007 --_—_. I�FX _-_ _._ �_ __ _._ _. ` I __ __..-__. L-�- ClCN ,..I L 1� C®2 OS r_- I r w00.7 r a004 L r a f _ p 1 r E J •` r L- r -1.1 L r I+ ��� i l \\i�l f l y J �� I. At S �� '1 i _-____.__ - -�_._. •� _-_. ___� �- . .i � 09 _ Prep lo C,D6 � ETev. 1 I c�7 0®6 ® s 163 -- i; - - �T 3f�-x�I1 -- � - s Corr � ;I � I 3 /J i ' — L -- s3oe 141 i B Stairs I 148 - --- 'l 10 li ' B7106 „> 1 87105 - B'107 III A�7 1 jMoii ) 00 __ �v7 I � I I I I Ago f l `I' , _- _i�� ` '.� Stora e 142 �t ___ �� � C �Ex3 LX 3 Eff '1 �� r�93 i B104 1004.. L10®.3.II �I I 9007 F Al A703 i it Scale : 1/8"=1'0" FA=2.2 1 ST FLR CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH Y COMMERCIAL ALARM & DETECTION INC. CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING QTY AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION ��;; C SIGNA NG N CIRCUIT 1-4 C 8 ANG FPLR OPEN OR COMBINATION OPEN AND RACEWAY FAC SILENT KNIGHT CONTROL PANEL 5820%L 72' TO TOP 1 AWG AMERICAN WIRE GAUGE EXXeI PBCIIIC T 17199 BENNETT ROAD C CEILING MOUNT DEVICE MT 99BEVERNON, WA ROAD NOTIFlCATION APPLIANCE CIRCUIT 1-4 C 16 AWG OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK5860R 60' TO TOP 3 W WALL MOUNT DEVICE EX exlsnrvc Device ,. LICENSE #COMMEAS48LO AU% A I 1-4 C 16 AWG 8273 FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REWIRE 3 323 Telegraph Rd ¢Sy. cs REL RELOCATE DEVICE i$ PHONE: (360) 848-1533 FAX: (360) 848-1072 SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 116 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY T SILENT KNIGHT MANUAL PULL STATION SKPULLDA 48' TO TOP 26 WP WEATHER PROOF DEVICE FACP FIRE ALARM CONTROL PANEL Bellingham We 98226 S SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKP CEILING 105 HOTO NAC ANN ANNUNCIATOR SYSTEM SENSOR HORNSTROBE SYS-i SHOWN PER DEMICE 84" TO TOP 14 AUx AUZILUARY POWER SUPPLY NURSE CALL DEVICE LEGEND ED SYSTEM SENSOR STROBE SYS-SR SHOM PER DEMIDE 84- TO TOP 3 Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING Q M SYSTEM SENSOR MINI HORN SYS-MHR N/A 84' TO TOP 31 PROJECT MANAGER :T.J. Mellema Low Voltage Systems NA TEKTONE MSTR STATION COMP, WIRELSS RCVR Ni NC510 NC15OR 1 © SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REQUIRE 2 PHONE :360-734-2872 g Y TEKTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC150R 93 ❑T SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRE 2 FAX :360-671-7616 na O Ave TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR 111 N/A SLC J-BOX N/A CEILING SUPERINTENDENT :Casey Anacortes, Wa 98221 Nc TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC15OR 92 ® SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REWIRED 13 AUTHORITIES HAVING JURISDICTION : Department o Health PHONE : 360-815-7223 TEKTONE SIGNAL REPEATER NC511 NC15OR 3 Wheelock Existing HS (Shown Qm) MIZ-24-LSM 15/75 DESIGNER DATE SHEET JOB N0. PGR TEKTONE PAGER SYSTEM NC366 NC15OR 1 MSTR TEKTONE MASTER STATION NC15DR 60" TO CTR 1 Department of Labor& Industries FAX ; KEY PLAN CHAD 1I05110 4 OF 8 9000156,157,221 AOR TEKTONE AREA OF RESCUE STATION IR150SS 48' TO TOP 4 City of Anacortes r stairs . - _ It I AEG it ® -- 225 ® _ -- i % _ S B226 — , l IIL --- _EBeauty xit IIL.- - �X _ �_.. Shop _I_.: ❑ _.-:1 III L C216_ 25 C®8 �� `_-� �I_. 7//I 227 I -t _n�1 echl A �I� ��_ _1 __�`__. r 7 AB 1 " _. .. 10 I _ A228 4i _..- 88 I1�il s(Qg� 228 . . II17 ;i� . Office m64 I ' LE, ®7 ill 41'I Activities X QD 8 J 1 Corr . ez F ® Ck� 1 C228 21 I 27J � A3� 18 III d � _, I,f - � If I II i ! '., �r ®5 e � �x T r l � 29� 1 .. F 7 � i n0 �I IFurn Gorr ,` 'c®4_._._.._ '®�i sues �' 7 274 �__.-.._; m0� -- --- 11 ---- -__-ll I j- ----� I `A. ! �,,-.. _._ --- .._.. -,i iI::- . ...._--I ANN [ zz4 ®� - leu � i 1 iI ' ® �� i Corr A22 8224 B228 � I 006 j \ �,L C221 _. ii I. 221� I : 1� L�' -p� 1".y C®9 1 qJ ® 'C�2 22 I �%, - - I V i t III �1 - �� - A27 - �I _ f `� � I � I 0 Il I I C L- ) c einant --I 222J x •• 1/B22222 \ 'i II_. i I - I La u nd A22 B2,e;a �A Sto` I '- N' .L. \\ ! i ! .--_.; - 22QI' l Stairs _� p I I 11 � ,1 , i A m045 Connection mU44� � 219 lh '� s �I 1 I I � I i 16 0 �. -� r -. - _ 16 218 Ili 1 - I I « - L t- ,- --0�, �I-- - - �� �� XI I # o - �� ® B Bz41 247 k I I I ' I , - — 7I I I - - ---.� -,�� �.-_ -M _. - '�......,.... - - 'M III " `I � i... i.. -..- i -.....C�r� 16 1 M ! - rl i� v i � I I � � I , � 11 � z41 l �' �� 16 l —� s - - � ,.� I � za7 ,� 1 y� I t 243 249 x ( i - 1 l _ _ -- - A�,41 1 �� '� / o� 43 � 5 _ �8245 _ n III �I � I _ i� �11 _L 1 `1 ] Ili r Tl _ I _, Lobby - I ' _ - � ' - -- / = = Ir \ x J -. _ jj \ f / \C® iC® / Nil '� i j11 /I - I ! IC247121 Q_.. ' C 4 \ .. �� 5' III I l _�,_• -� Ili - -. j � y i�L_ L tL� -_� - ,l, 1 L,��'--r �I ., v1 _ i ,:-�. I �,_,� 1�1 ._,f� . : i III r -. I l�. I - � -:. T its. Ji ;' '� II , I_ \ _ __.� '•,. Ir _ � I I 'I I � I ' _._. %, I ;� � - l- � - - Z--1 --I -- I! �I --- - ' - -- -- - - � "-- IL AOR I'--' 047 ,.� 6 �..16 II_-_ Ij� yt _- - !I Sta r^J! 11 �I � v._ ___ II �! �I II � II ! i t $ I I, II 215 ! 4�, ,I Corre �� sD7a 200 IIO - ---- �5 ; 211 • 77 Bo B Stairs - _-__ . --- I _ '3 _t1 i. kl __.. I- L-� �I - __� I 110 6 I _ S1 i_ II �i - ` " `.� � '( Ili . ,- r_J R II I�® �I -1 l III �N-. �I�II - .^,I ---.- °..� li / ',l:� �( 1,ICI'\ S FI ! it Ali I 'I� II.�,.� r Ill !�,' r- I''IA A i,lil ,.--I I� I' /' DAMPERS RELAYk 'L., I�i � ; .__ A 1 1I 'z � ,�, I. 1-... L. EIeV �nL- .... ®21 .__.___ !I' �I �___ � --_- . c® -j1 �I l !� I! I� , I�i _— III Ii 1 ,Ill, e�B ,.�� I� ,_r --__- _Ic25 , . ' -E_ .: _ _ _ - I :' i' 'i N . - E- ,; --I . . _. .2r. ��� 214 Fill, Mech' Trash 1 illll �f --- -, = 212 it i r 1:-: '' 'T�J�I�'I 1 ! �fi �I�I /� -�� 1 _I �I Ali 213 - - v 11 _i D"tolat �II 7777� i� .,T,� . ' L ,_,_� r. _-�__ - _-J d \.. _'_ T- .. - FIr AUX III,I I� :� _, �' I� �I� i., �i Ckt916 I'l _ � I f I L� _ I I III 1 -11 I + / :� �i �_-� _--_�._ l ..,!_ III IBC®S �� C� _ �a:�� _.'I .... _ M _ 1 r MElll l .. -3 1s � - h ., � �� I 76 : l � � 242 ... 6 ! �_, 111 244� ll 248 � I 250 J JIB242 B®I —� iB®B B2501 A220 �� - - -- � � _ it � F I II' � � az44 I I I I l 46 if r 1� o-� M l I I r 246 A246 it FA=3. 1 2 N D F L R CABLE CODES FIRE ALARM 8L AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH COMMERCIAL ALARM & DETECTION INC. CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING OTY AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION AWG AMERICANWIREGAUGE Exxel Pacific C SIGNALING LINE CIRCUIT 1-4 C 8 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY FAC SILENT KNIGHT CONTROL PANEL 5820XL 72' TO TOP 1 C CEILING MOUNT DEVICE 17199 BENNETT ROAD NAC NOTIFICATION APPLIANCE CIRCUIT 1-4 C 16 AWG OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK586OR 60' TO TOP 3 W WALL MOUNT DEVICE MT VERNON, WA 98273 Ex EXISTING DEVICE ® LICENSE #COMMEA1948LO AUX A I AR CIRCUIT 1-4 C 6 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REQUIRED 3 323 Telegraph Rd �1 REL RELOCATE DEVICE ? PHONE: 360 848-1533 FAX: 360 848-1072 SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY F SILENT KNIGHT MANUAL PULL STATION SKPULLDA 4T TO TOP 26 WP WEATHER PROOF DEVICE ( ) ( ) B SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO CEILING 105 FACP FIRE ALARM CONTROL PANEL g Bellin ham Wa 98226 L 17 ANN ANNUNCIATOR NURSE CALL DEVICE LEGEND SYSTEM SENSOR HORNSTROBE SYS-P2R SHOWN PER SPACE El TO TOP 14 AUX AUXILLIARY POWER SUPPLY $ SYSTEM SENSOR STROBE SYS-SR SHOWN PER DEVICE 84' TO TO 3 PROJECT MANAGER :T.J. Mellema Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING Q M SYSTEM SENSOR MINI HORN SYS-MHR N/A 84' TO TOP 31 Low Voltage Systems MAIN TEKTONE MSTR STATION COMP, WIRELSS RCVR NC501A, NC510 NC15OR 1 © SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REQUIRED 2 PHONE :360-734-2872 9 Y TEKTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC150R 93 SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAX :360-671-7616 1300 O Ave TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR 111 N/A SLC J-BOX N/A CEILING SUPERINTENDENT : Casey Anacortes, Wa 98221 xc TEXTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC15OR 92 ❑R SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REQUIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE : 360-815-7223 TEKTONE SIGNAL REPEATER NC511 NC15GR 3 Wheelock Existing HS (shown dim) MIZ-24-LW 15/75 DESIGNER DATE SHEET JOB NO. PGR TEKTONE PAGER SYSTEM NC366 NC15OR 1 MST TEKTONE MASTER STATION NC15OR 60" TO CTR I Department of Labor 81 Industries FAX ; AOR TEKTONE AREA OF RESCUE STATION IR15DSS 48' TO TOP 4 City of Anacortes I KEY PLAN CHAD 1/05/10 5 OF 8 90001$6,1$7,221 1 �p�n fi^. �I n� ragi p_I Malrlt� 'I C it cz®oo �...; � ��..._ ®o I�` Laundry I'1 pp �� ! Office ff1 �u 9 Dining a „ q , � x tin 8-L Corr 6 6 .".. .. ® L�" ,-. A3i4 (� (� ®4 ANN I ez„I ) CHI C213 `) lil 021 CMc � -- i '., aas _ Co ! r Office -. L� �� 0�03F I� ..EI 6 „ ��I _., r St43 IC TES ! u. & JL q O NOW r A - C)Ini ng - Siair, , _ I aartan li _� � r i � ', I� 3� i 1 _ �, d FF an rla ®3 ®z ' L l c I � i. Cxe1 y r ..-..t air Corr Si Living Ki Itchen c ; . ti -(] y I I f Ali A23 �l I 1 ii. i \Naltress ` LiFin Office -- r- Electrici'l hCLvl I AU AU S AUX os i Office Storr3ge I FRCP I, __ E1:nlrtg LIJI . APA . Lobby 1 , m 5 D100 i JJclrlensII r . III Mall) C i L I -._ .. i Merl I - E [,. Prep Rm [;<<1 I McfT T ia DialO Gorr R " N11 �I M- n wwi Stall-s O `5 Sprinkler ,�I /. ITN J I A�3 F_'rJ _. — ers - I I I I i II I - pp �d Iowa 10 A 300 / i. CxxO I [pptfi I ' A3ie z1 (D l I Corr - t A1,7 II 11111217 w, 4�a CN7 Scale : 3/32"=1 e0ex FA=3 .2 2ND FLR CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH COMMERCIAL ALARM & DETECTION INC. CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING CITY AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION SEC SIGNAUNG LINE CIRCUIT 1-4 C 8 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY FAC 820XL SILENT KNIGHT CONTROL PANEL 5 72• TO TOP 1 AWG AMERICAN WIRE GAUGE Exxel Pacific 17199 BENNETT ROAD C CEILING MOUNT DEVICE NAC NOTIFICATION APPUANCE CIRCUIT 1-4 C #16 AWGFPUR OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK586OR 60" TO TOP 3 W WALL MOUNT DEVICE MT VERNON, WA 98273 Ex EXISTING DEVICETelegraph ` `t ® LICENSE #COMMEA1948LO AUX A I RY POWER CIRCUIT 1-4 C 6 AWG FPIR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REWIRED 3 323 Rd aEL RELOCATE DEVICE u' SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY F SILENT KNIGHT MANUAL PULL STATION SKPHOTO C48'EILING TO TOP 26 PAWP P �RE ALARM DEVICE Bellingham Wa 98226 PHONE: (360) 848-1533 FAX: (360) 848-1072 s SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO CEIUING 105 ANN ANNUNCIATOR 9 NURSE CALL DEVICE LEGEND SYSTEM SENSOR HORNSTROBE SYS-P2R SHOW Pea Di B4" TO TOP 14 AUX AUXILLIARY POWER SUPPLY SYSTEM SENSOR STROBE SYS-SR SHOW,PER Di Be TO TOP 3 Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING QTNj MCI SYSTEM SENSOR MINI HORN SYS-MHR N/A Ii TO TOP 31 PROJECT MANAGER :T.J. Melleme LOW Voltage Systems MAIN TEKTONE MSTR STATION COMP, WIRELSS RCVR NINC510 NC15OR 1 © SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REQUIRED 2 PHONE :360-734-2872 " 9 1300 O Ave rQ TEKTONE STATIONARY NURSE CALL TRSMITTER SF502 NC150R 93 ❑T SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAX :360-671-7616 AN TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR 111 + N/A SLC J-BOX N/A CEILING SUPERINTENDENT :Casey Anacortes, Wa 98221 TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC15OR 92 0 SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REQUIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE :360-815-7223 TEKTONE SIGNAL REPEATER NC511 NC15OR 3 Whedod Existing HS (shown dim) MIZ-24-LSM 15/75 DESIGNER DATE SHEET JOB NO. PGR TEKTONE PAGER SYSTEM NC366 NC15OR 1 IMSTRI TEKTONE MASTER STATION NC15OR 60" TO CTR 1 Department of Labor& Industries FAX : KEY PLAN AOR TEKTONE AREA OF RESCUE STATION IRI5OSS 48' TO TOP 4 Cit of Anacortes CHAR 1/05/10 6 OF 8 9000156,157,221 I Guest I I I Room 'I E 112 B®' �,r A311 l ®2 ' !B®2 III B©3 314.. 12 7 A313 ®�1 I LILL ,,:.. �1* I14x+ 2 .. i A�14 C3141 L I LI� ®1 31 2 C313 . j S I I III l L_346 - _ i � 12 S s003 Corr s006 p$ �001 S s005 - - _- - -- p 342__',' p pS IMech( L �I �y Ir 345�p�� 0301` €� L � F OBO IN - - ---�J1 C301 ' ,�' I , _.1 T� 'I ILF,_<.12 C303 � '._-_- C30 t- C®5 11 -- -_ ' f JIL- E;,2 L� _ --_- �._I� }��%12 � ;i OB, * �07 III 13304/�' �1 I1 3G4 k -jr) j \ -B 3 �f 0302/ ,3Q2...I _01-J' rt� J �� i �.,,;d Aa A303 `� r 3 B ✓� _____ al L Stairs ! H249 WT L A2 A , Trasl- sal Stairs I - --- - - - —-- I L - - -- -- - - - - -- Scale : 1/8"=1'0" I I I % �I -- 7 1 JI ® 'BOOI �001 M 7 � l� I �� 1 M Boo, IIJ I�. -- � 1 B®,I� ICI 341 I' I. -_:' ..(; -' 111 -.....,.,,.\ �jIIM _--I, rj -,r- ----� \� 1 II4.. I , i!' 4�3 �'All __._-_. _ ' 19 !I 3$4�7 - II 1 �.`_'I 349 ' ACIM A111101 L A001 _ _- 0'I Y 7Y. ,r T r—� III_-I _ I � t 1 ( _ 7 __.- r _41 II i � lcon� III r -.� - J. � I _,l „ , 1, �.-i L_. ,:-; _....,-�, ,I �, „ '` ��, 1 �,, k� r,J.__, �1 i-_- t :-' ✓ J'-, i`�I ) Ej 316/ �i �4 1 ;COOT u. `F rJ ,,,. .{ �� C004 I,, b--•__ I COOL A ' :y '',, '0001 001 Y " l' � ' k I n� n__1 �r liI I ''_ '� ��_ � yll �A 11 lj _�-_— III- �/ , ' •{ _-_1 Y. Ali, (i !1 _�I 1 �' L/ •."I' , -.::, r I' ill -::.'� -,.,, T ..-, L�r� —71 � I.. , T I II_ _ } __- `_ _j _'. __". il..__ ,� ..ill. , a �,f_:I 'I _-. I _.L...-�. .___._-I_... ___-_.__.L r 1I iY_-"-- - -- --_.. v� _ .-. _... _-._- _-_r - 'J_. ____..__- � z.-7 �m086AOR �� 1 1 Q -- - x3 F m064 1 + I i AOR � I > I r - L Lr .CS << Corr j ] .8 �a Stairs B 1 311 I 8026 3005 __. _ __----- __._ it �� �,� 315 a 29 r �I p [J ICI 1 u f' t . -.. .'i __ _ _. .;7 - ,� r3 ,1 I __- ll =T: -'l� r- -- -�- 'r- --_ -_ -?- -- ':1 ;. , - ' it _ - c- h ,- ,. �. T "'- --� 'I I I. �_-i __� � L / I` - r -. _.r4- ! ,�_---r ' .. ! A -__. -i L: �I� ,,,�� ", I I �LI a rz �'I' L. SMOKE III Trash ` -._ 1 'I li � e..d I'� ,�I� ',,r• -yl �, Jy,Y I�, � �, I- �,- I , III it ,1 : L, Ikk! I. : � , . ' . J i '. ( ..> I , _ .- II � ' _—_ --__- .. _ ,,. i �, .... pp I �- PAMPERS RELAY..' ii �� r.. I_313 I. I } n... —1 ", J 9 'I a !cool C001i , Ili III 0011N4ech x u l p � Elev - ' 314 '� ` 'I. 312 lL L1^- -f�l ,� ri 1 � '.. � - -!I ; J! , r yt' - L ,.� DI to,tl ,h �� r( _ -J�_. :"✓j ..'I li it Fir AUX III i. V _______ I._�.. ..mill CIR/17 �� ___ -__ �`-� �„ - !I j M 7 M cool 7 -� M FOURTH - 342 344 } BOB, -=` - I 35o I © Blot 34� OO "� L FLOOR r a ❑ c7 B A001 A007 ' � I A IS _ .—G k •J__'. it-.- --ly )]__ � I M �Ii } I 1�'i l M L346 III ' L.I Scale : 1/8EE=1I FA=4ml 3RD FLR CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH COMMERCIAL ALARM & DETECTION INC. CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING OTY AFT ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION A. AMERICANWIREGAUGE Exxel Pacific SLC SIGNALING UNE CIRCUIT 1-4 C 8 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY FAC SILENT KNIGHT CONTROL PANEL 5820%L 72. 70 TOP 1 17199 BENNETT ROAD c CEIWALL MOUNT DEVICECE MT VERNON, WA 98273 NOTIFICATION APPLIANCE CIRCUIT 1-4 C 16 ANG OPEN OR COMBINATION OPEN AND RACEWAY ANN SILENT KNIGHT REMOTE ANNUNCIATOR SK5860R 60• TO TOP 3 w WALL MOUNT DEVICE Ex ExISTING DEVICE '� ' ® LICENSE #COMMEA1948LO AU% A R 1-4 C 6 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REQUIRED 3 323 Telegraph Rd a�° REL RELOCATE DEVICE SBUS FIRE ALARM SBUS CIRCUIT 1-4 C 16 AWG FPIR OPEN OR COMBINATION OPEN AND RACEWAY F SILENT KNIGHT MANUAL PULL STATION SKPULLDA 48" TO TOP 26 AP WEATHER PROOF DEVICE PHONE: (360) 848-1533 FAX: (360) 848-1072 s SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO CEILIING 105 ANN FIRE ALARM corvraa PANEL Bellingham Wa 98226 - ANN ANNUNCIATOR arc SYSTEM SENSOR STROBE SYS—P2R SHOW PER DE„CE fix- TO TOP 1a ADx AU%IL ARV POWER SUPPLY NURSE CALL DEVICE LEGEND SYSTEM SENSOR STROBE SYS-SR SHOWN PER DEVICE EllEllTO TDP 3 Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING Q M SYSTEM SENSOR MINI HORN SYS-MHR N/A Ba To TOP 31 PROJECT MANAGER :T.J. Mellema MAIN TEKTONE I STATION COUP, WIRELSS I NC501A, NC510 NC15OR 1 © SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REQUIRED 2 PHONE :360-734-2872 Low Voltage Systems TFNTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC15OR 93 ❑T SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAX :360-671-7616 1300 O Ave TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 NC15OR 111 N/A SLC J—BOX N/A CEIUNG SUPERINTENDENT :Casey Anacortes, Wa 98221 TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 NC15OR 92 ® SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REWIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE :360-815-7223 TEKTONE SIGNAL REPEATER N0511 NC15OR 3 Wheelock Existing HS (shown dim) MIZ-24—LSM 15/75 Department of Labor& Industries DESIGNER DATE SHEET JOB NO. POR TEKTONE PACER SYSTEM NC366 NC15OR 1 MSTR TEKTONE MASTER STATION NC15OR 60" TO CTR 1 p FAX ' KEY PLAN AOR TEKTONE AREA OF RESCUE STATION IR150SS 48• TO TOP 4 Cityof Anacortes CHAD 1/05/10 7 OF 8 9000156,157,221 I5til II 363 Beauty 1349 --,5L I . III , it T -- I : Asa E�e 35 I v 9 , 062li Stairs 1u� ,�� s11 isz I I ' I I � _ 15 I : AR5 14 Multi- I - 4 1 Purpose SIC®5'1 B®5_ - I I 330 I � I o C\ ca19, AEG ' � Ileale II to 1. 1 14 I j JI x I C33330 A®8 I I i I L: I j I R 1', Corr e e� 352 L�114/ ® 14, 1 I A329 19 { y 1J (-ZIA � awl � I e317 - � C317 C t az9 Ili 3-6-1 J 317 I �� �Jtc3tf ( I Bale � 1 I _ I 7 �� ,�._B7_ i�� �� - V ��;iCS �� �I� Tenant � ti�l �F� 1 �A a s B 6 ._ ` �,a - - _J Lounge 8021 �1 Lauend I EX - I.. A28 1 T �- �S �I -- 26 ©7 �� 8029 Prep �J - III FJ 11 12 % Ae / - a92 / Po cs2e 364 I { / l �� II • � I I I FX14 ( ii 1: � FX 4 i j I I� III ✓ Y ,.— -%• Imo... ___ — —_ T Corr_.... L 1 S _ n Q - Qom, a 17 1-353- 1e s 9 1s ' Jan °®1 -' lli III �� C31 3551 li a2z --�14 IX _-_ i C320 C I, �. ��t4 8320 B322 6319 Aaz, Ij I � � 320 A320 airs I I li I I I� I I s4 I I I I I , Scale : 1,8111=,.o.. FA=4.2 3RD FLR CABLE CODES FIRE ALARM &AOR DEVICE LEGEND ABBREVIATIONS REVISIONS CONTRACT WITH CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE MODEL CANDELA MOUNTING CITY AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION " }"`''`° COMMERCIAL ALARM & DETECTION, INC. FAC SILENT KNIGHT CONTROL PANEL 5820XL 72' TO TOP 1 AWG AMERICAN WIRE GAUGE EXXeI PBCIfIC 17199 BENNETT ROAD SLC SIGNALING N CIRCUIT 1-4 C 8 AWG I OPEN OR COMBINATION OPEN AND RACEWAY C CEILING MOUNT DEVICE NOTIFICATION APPLIANCE CIRCUIT 1-4 C 16 AWG OPEN OR COMBINATION OPEN AND RACEWAY ANTI SILENT KNIGHT REMOTE ANNUNCIATOR SK5860R 60" TO TOP 3 w WALL MOUNT Device MT VERNON, WA 98273 ex ExlsnNC Device + s LICENSE #COMMEAI948L0 A I 1-4 C 6 Al FPLR OPEN OR COMBINATION OPEN AND RACEWAY AUX SILENT KNIGHT POWER EXPANSION PANEL SK5496 AS REWIRED 3 ReL ReLocnrEoewce 323 Telegraph Rd .: SBUS FIRE ALARM SBU CIRCUIT 1-4 C 16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY F SILENT KNIGHT MANUAL PULL STATION SKPULLDA 48" 1b TOP 26 wP WEATHER PROOF DEVICE Bellingham Wa 98226 R tt PHONE: (360) 848-1533 FAX: (360) 848-1072 5 SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SKPHOTO COILING 105 FACP FIRE ALARM CONTROL PANEL r ANN ANNUNCIATOR X �C NURSE CALL DEVICE LEGEND SYSTEM SENSOR HORNSTROBE SYS-1 sHi PEA DEUCE 64 To TOP 14 Aux AUXILLIAR POWER SUPPLY SYSTEM SENSOR STROBE SYS-SR SHINN PER HENCE B4" To Top 3 PROJECT MANAGER :T.J. Mellema Chandler Square SYMBOL MANUFACTURER TYPE MODEL MOUNTING Q M SYSTEM SENSOR MINI HORN SYS-MHR N/A 84' TO Top 31 Low Voltage Systems - MAIN TEKTONE MSTR STATION COMP, WIRELSS I NC501A NC510 NC15OR 1 © SILENT KNIGHT WATERFLOW SWITCH MODULE SKMONITOR AS REQUIRED 2 PHONE :360-734-2872 1300 O Ave TEKTONE STATIONARY NURSE CALL TRANSMITTER SF502 NC15OR 93 ❑r SILENT KNIGHT TAMPER SWITCH MODULE SKMONITOR AS REQUIRED 2 FAX :360-671-7616 Anacortes, Wa 98221 TEKTONE MOBILE PENDANT NURSE CALL TRANSMITTER SF501 INCISOR 111 N/A SILL J-BOX N/A CEILING I I I SUPERINTENDENT :Casey xc TEKTONE WATER RESISTANT NURSE CALL TRANSMITTER SF501 Ni 92 ® SILENT KNIGHT ADDRESSABLE RELAY MODULE SKRELAY AS REWIRED 13 AUTHORITIES HAVING JURISDICTION : Department of Health PHONE :360-815-7223 TEKTONE SIGNAL REPEATER NC511 NC15OR 3 Wheelock Existing HS (shown dim) MIZ-24-LSM 15/75 DESIGNER DATE SHEET JOB NO. Department of Labor& Industries FAX PGR TEKTONE PAGER SYSTEM NC366 NC15OR 1 MS TEKTONE MASTER STATION NC15OR 60" TO CTR 1 KEY PLAN CHAD 1/05/10 8 OF 8 9000156,157,221 AOR TEKTONE AREA OF RESCUE STATION IR15055 48• TO TOP 4 Cityof Anacortes