Loading...
HomeMy WebLinkAboutBLD-2024-0857 - RESIDENTIAL REMODELFIXTURES Qty Plumbing Fixtures PARCEL: P31827 LEGAL DESCRIPTION: APPLICANT: Brich, Jed 2708 J Ave Anacortes, WA 98221 3603916272 OWNER: BRICH JEDEDIAH FITZPATRICK UNKNOWN ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 100000.00 $100,000.00 $100,000.00Total: FEES:Paid Due SFR or duplex site plan review $60.00 $0.00 State Building Code Council fee $6.50 $0.00 Building Permit Fee $993.75 $0.00 Mechanical and plumbing remodel fixtures fees $55.15 $0.00 Storm Water Review Sq Ft $30.72 $0.00 Plan Review Fee $645.94 $0.00 $0.00Totals : REQUIRED INSPECTIONS Initial BMP's. This stormwater inspection must be completed prior to any other inspections. Footings Sewer Line Sewer Line STORMWATER BMPS 1ST MID PROJECT INSPECTION Mechanical Rough-In Plumbing Rough-In Shear Wall and Nailing Framing Drywall or Lath CONSTRUCTION CONTRACTOR:KREIDER CONSTRUCTION INC 1010 22ND ST ANACORTES, WA 98221 360.707.5588 License: KREIDCI024PE Expires: 10/30/2027 $1,792.06 BLD-2024-0857 RESIDENTIAL REMODEL ISSUED: EXPIRES: 08/17/2025 08/17/2027 PROJECT NAME: 2708J ADDITION SITE ADDRESS: 2708 J AVE ANACORTES Page 1 of 2Printed by : Jennifer Watson on: 10/29/2025 12:34 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ Please request inspections online through the permit portal. If that is not possible please call (360) 293-1901 for Building or Planning inspections. For Public Works inspections, please call (360) 293-1938. Foundation Storm Drain Connection Perimeter Drains Underslab Underground Plumbing Underfloor Gas Piping Insulation Fenestration U-Factors Roofing Final Permeable Soil Depth Cross Connection or backflow assembly verified Building Final Stormwater Final Page 2 of 2Printed by : Jennifer Watson on: 10/29/2025 12:34 PM City of Anacortes, WA RESIDENTIAL REMODEL BLD-2024-0857 After construction entrance is removed, driveway/curb/gutter/sidewalk need to be constructed per AMC and engineering standards. N TITLE PAGE / PROJECT SUMMARY / SHT. INDEX / VICINITY MAP / PROJECT DIRECTORY REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: BRICH ADDITION 2708 J AVENUE, ANACORTES, WA 7/30/2025 PROJECT DIRECTORY OWNER JED BRICH 2708 J AVENUE ANACORTES, WA 98221 CONTACT JED BRICH 360-391-6272 WILLEEQUIXOTEE@GMAIL.COM BUILDING DESIGNER CURRIE DESIGN GROUP, LLC 3916 S Avenue ANACORTES, WA 98221 CONTACT STUART CURRIE 360-941-1789 PROJECTS@CURRIEDESIGNGROUP.COM STRUCT. ENGINEERING TIM GARRISON, PE 2316 ANTONE WAY ANACORTES, WA 98221 CONTACT TIM GARRISON, 360-708-1865 TIMG@TIMKGARRISON.COM GENERAL CONTRACTOR JED BRICH 2708 J AVENUE ANACORTES, WA 98221 CONTACT JED BRICH 360-391-6272 WILLEEQUIXOTEE@GMAIL.COM SHEET INDEX SHEET SIZE ARCHITECTURAL D T1 ABBREVIATIONS PROJECT SUMMARY T1 TITLE PAGE / PROJECT SUMMARY / SHT. INDEX / VICINITY MAP / PROJECT DIRECTORY T2 GENERAL NOTES / ALARMS / VENTILATION / ENERGY CODE & COMPLIANCE C1 SURVEY C2 SITE PLAN A1 EXSTING FLOOR PLANS - MAIN LEVEL A2 EXTERIOR ELEVATION - NORTH & SOUTH A3 BUILDING SECTIONS AA & BB A4 TYP. WALL SECT., WINDOW WRAP S1 STRUCTURAL ENGINEERING PLANS S2 STRUCTURAL ENGINEERING NOTES INTENT OF DRAWINGS The Intent of these Documents is to provide the basic information necessary for an experienced General Contractor to properly execute the work, complete in all respects unless specifically noted otherwise. Dimensions:  The drawings may not be drawn to scale in some instances; follow dimensions but do not scale drawings.  Where dimensions are noted “verify”, consult the Building Designer for critical dimension criteria.  All dimensions are given to the face of stud or top plate, plywood subfloor, and face of concrete, unless noted. Interpretations:  These documents are subject to interpretation.  Any detail, dimension, or statement not completely clear to the Contractor shall be referred to the Building Designer for interpretation.  By proceeding without interpretation, the Contractor assumes the responsibility for making corrections, if so directed by the Building Designer, at the Contractor’s expense. Conflicts:  Conflicts in the drawings or conflicts between any drawing and specification shall be brought immediately to the attention of the Building Designer who will render a final decision as to the result intended.  Where conflicts occur, it shall be assumed that the Contractor has figured the most expensive installation.  If the Contractor does work that conflicts with another part of the drawings or specifications before receiving a decision from the Building Designer, he shall remove all such work deemed necessary by the Building Designer at his own expense.  After the Contract is signed, no increase in price will be allowed for any conflict or for any omission when the intent, as interpreted by the Building Designer, is established by the character of the project, similar conditions which exist elsewhere in the project, or by surrounding conditions. Codes and Ordinances:  The whole of the work is to be executed in strict accordance with applicable codes and ordinances.  The Contractor shall secure and pay for all permits except general Building Permit which the Owner will secure.  Any work required by code but not specifically called out in drawings or specifications is part of this contract.  If there is a conflict in drawings or specifications with a code, the code shall govern.  Any conflicts shall be brought to the attention of the Building Designer per “Conflicts” paragraph above.  At completion of the work, supply the Owner with “final signed off” electrical, plumbing, mechanical and building permits (even though some may be Owner secured). PROJECT LOCATION VICINITY MAP GENERAL NOTES / ALARMS / VENTILATION / ENERGY CODE & COMPLIANCE REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: 7/30/2025 SHEET SIZE ARCHITECTURAL D T2 VENTILATION GENERAL NOTES 2021 ENERGY CODE ALARMSALARMS 2021 D01D01 W01W01 W01W01 D02D02 DN UP E1E1 E2E2 E3E3 A A4 A A4 A A4 A A4 B B B B 24'-9 1/2" 16'-1 3/8" 33'-11 15/16" 6'-9 1/4"7'-1 3/16"8'-5 13/16" 2'-5 1/4" 16'-1 3/8" 6 11/16" 13'-2" X 13'-5" 10'-0" X 11'-5" 9'-11" X 10'-1" 13'-2" X 19'-6" 3'-9" X 10'-2" 7'-10" X 6'-0" 5'-11" X 2'-0" 11'-5" X 8'-7" 22'-10" X 15'-0" EXST. DECK PROPOSED UTILITY ROOM, ARTS & CRAFTS ADDITION EXST. KITCHEN EXST. LIVING EXST. BEDROOM EXST. BEDROOM EXST. BATH EXST. HALL EXISTING HOUSE 1 A4 1 A4 E4 A3 E4 A3 CLOSET DN W02W02 D03D03 W04W04 W05W05 W03W03 W03W03 E1E1 E2E2 E3E3 A A4 A A4 A A4 A A4 B B B B 24'-2" 7'-9"2'-3"2'-7"3'-11 5/8"7'-8" 12'-6 15/16"11'-7 5/8" 24'-2 9/16" 5'-0 7/16" 6'-8" 16'-4 15/16" 16'-5 3/8" 1'-9 7/8" 1'-6 3/4" 11'-2" X 15'-10" 4'-6" X 8'-6"ADDITION PROPOSED BEDROOM DN EXISTING HOUSE PROPOSED BATH E4 A4 E4 A4 D2 A4 D2 A4 EXISTING ATTIC 7' - 6" UPPER LEVEL SETBACK 1 2SCALE 1/4" = 1' - 0"0 3 PROPOSED MAIN LEVEL FLOOR PLAN 4 5 10 1 2SCALE 1/4" = 1' - 0"0 3 PROPOSED UPPER LEVEL FLOOR PLAN 4 5 10 3068 2846SH 2846SH 2846SH 5133LS 5146FX30685146FX 2846SH 41068 21068 2868 21068 2868 411682868 DN 6'-4 3/16" 2'-8" 4'-1 13/16" 16'-2" 4'-9" 5'-1" 5'-8" 2'-8" 15'-11" 24'-3"2' 26'-3" 4'-11" 2'-8" 4'-3" 11'-10" 9'-1" 13'-2" 34'-1" 15'-2"3'6' 2'-1"24'-2" 26'-3" 4'-9" 5'-1" 5'-8" 2'-8" 10'-4" 2'-8" 2'-11" 34'-1" 2' EXST. DECK EXST. LIVING EXST. BEDROOM EXST. BATH EXST. BEDROOM EXST. KITCHEN EXST. HALL 1 2SCALE 1/4" = 1' - 0"0 3 EXISTING MAIN LEVEL FLOOR PLAN 4 5 10 EXSTING FLOOR PLANS - MAIN LEVEL FLOOR PLANS - MAIN LEVEL FLOOR PLANS - UPPER LEVEL REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: 7/30/2025 SHEET SIZE ARCHITECTURAL D A1 TOP OF FOOTING -2'-2 3/8" 8" TOP OF SUBFLOOR - 1ST FLOOR -1'-2" 1'-0 3/8" TOP OF PLATE 7'-11 1/8" 9'-1 1/8" TOP OF SUBFLOOR - 2ND FLOOR 8'-7 7/8" 8 3/4" TOP OF PLATE 17'-2 9/16" 8'-6 11/16" RIDGE 18'-2" 11 7/16" BOTTOM OF FOOTING TOP OF FOOTING -2'-2 3/8" 8" TOP OF SUBFLOOR - 1ST FLOOR -1'-2" 1'-0 3/8" TOP OF PLATE 7'-11 1/8" 9'-1 1/8" TOP OF SUBFLOOR - 2ND FLOOR 8'-7 7/8" 8 3/4" TOP OF PLATE 17'-2 9/16" 8'-6 11/16" RIDGE 18'-2" 11 7/16" BOTTOM OF FOOTING W01W01 D02D02 W04W04 W01W01 W05W05 14'-6 3/4" 1'-6 3/4" GRADE 12 6 12 6 12 6 1/4 12 7' - 6" SETBACK 14'-6 3/4" 1'-6 3/4" GRADE 12 6 12 6 12 6 1/4 12 7' - 6" SETBACK W01W01 D02D02 W04W04 W01W01 W05W05 W03W03 W03W03 D01D01 BOTTOM OF FOOTING-2'-10 3/8" TOP OF FOOTING -2'-2 3/8" 8" GRADE -2' 2 3/8" TOP OF SUBFLOOR - MAIN LEVEL -1'-2" 10" TOP OF FOUNDATION 7'-8 1/8" 8'-10 1/8" TOP OF (2) P.T. 2X12 PLATES 7'-11 1/8"3" TOP OF SUBFLOOR - UPPER LEVEL 8'-7 7/8"8 3/4" TOP OF PLATE 17'-1 1/2" 8'-5 5/8" HIGHEST RIDGE 18'-2" 1'-0 1/2" BOTTOM OF FOOTING-2'-10 3/8" TOP OF FOOTING -2'-2 3/8" 8" GRADE -2' 2 3/8" TOP OF SUBFLOOR - MAIN LEVEL -1'-2" 10" TOP OF FOUNDATION 7'-8 1/8" 8'-10 1/8" TOP OF (2) P.T. 2X12 PLATES 7'-11 1/8"3" TOP OF SUBFLOOR - UPPER LEVEL 8'-7 7/8"8 3/4" TOP OF PLATE 17'-1 1/2" 8'-5 5/8" HIGHEST RIDGE 18'-2" 1'-0 1/2" W03W03 W03W03 D01D01 DOOR SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY FLOOR SIZE DESCRIPTION D01 1 1 9080 EXT. BI-FOLD GLASS WALL D02 1 1 2868 L EX EXT. HINGED-PANEL D03 1 2 2668 L IN HINGED-PANEL WINDOW SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY FLOOR SIZE EGRESS DESCRIPTION W01 2 1 5030LS LEFT SLIDING W02 1 2 2640SC YES SINGLE CASEMENT-HL W03 2 2 2846SH SINGLE HUNG W04 1 2 5030LS LEFT SLIDING W05 1 2 3010AW SINGLE AWNING 54 PROPOSED EXTERIOR ELEVATION - SOUTH SCALE 1/4" = 1' - 0"0 1 2 3 10 5 104 PROPOSED EXTERIOR ELEVATION - NORTH SCALE 1/4" = 1' - 0"0 1 2 3 5 104 PROPOSED EXTERIOR ELEVATION - WEST SCALE 1/4" = 1' - 0"0 1 2 3 EXTERIOR ELEVATION - NORTH & SOUTH EXTERIOR ELEVATION - WEST DOOR SCHEDULE, WINDOW SCHEDULE REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: 7/30/2025 SHEET SIZE ARCHITECTURAL D A2 D1 A5 D1 A5 BEDROOM WORKSHOP BEDROOM WORKSHOP BUILDING SECTION A-A SCALE 1/4" = 1' - 0"0 5 101234 1012SCALE 1/4" = 1' - 0"0 3 ROOF FRAMING PLAN 4 5 BUILDING SECTION B-B SCALE 1/4" = 1' - 0"0 5 101234 W01W01 W01W01 W04W04 W05W05 D02D02 1' BEDROOM BATHROOM STORAGE WORKSHOP 1/4 12 12 6 1' BEDROOM BATHROOM STORAGE WORKSHOP 1/4 12 12 6 W01W01 W01W01 W04W04 W05W05 D02D02 1/4 : 12SOUTH ROOF 6 : 12NORTH ROOF SOUTH ROOF BLKNG BLKNG NORTH ROOF RIDGE SOUTH ROOF SUB FASCIA 1 2SCALE 1/4" = 1' - 0"0 3 FOUNDATION PLAN 4 5 10 5/8"TYPE X G.W.B. EXST. WALL 2X4 WALL FRAMING NEW WALL 2X4 WALL FRMNG OVERFRAME EXST. ROOF 1/2" PLYWOOD 1/2" PLYWOOD 1/2" G.W.B. 1 2SCALE 1/4" = 1' - 0"0 3 UPPER LEVEL FLOOR FRAMING PLAN 4 5 1 2SCALE 1/4" = 1' - 0"0 3 ROOF PLAN 1 2SCALE 1/4" = 1' - 0"0 3 COMMON WALL CONST. 12" 12" 5/8" TYPE X G.W.B. 1/2" PLWD PER STRUCT. ENGR. EXST. 2X4 FRAMING EXST. 1/2" LATH EXST. PLASTER ASPHALT SHINGLES FLR. JOIST PER STRUCT. ENGR. EXST. RAFTERS 1/2" G.W.B. 1/2" PLWD PER STRUCT. ENGR. 2X4 FRAMING W/ INSUL. W.R.B. 2" ROCKWOOL INSUL. HORZ. Z GIRT MIN 1/8" GAP BTWN EXT FIN & WATER RESISTIVE BARRIER CORRUGATED METAL SIDING EXST FLR JOIST 4X4 BLOCK @ 24" O.C. P.T. SILL PLATE MEMBRANE ROOFING EXST. SUBFLOOR WINDOW 1/2" G.W.B. 5/8" A.B. @ 60' MAX EXST. CEILING JOIST & FINISH 1/2" G.W.B. 1/2" PLWD PER STRUCT. ENGR. EXST. 1/2" LATH EXST. 2X4 FRAMING 11RD11RD 1PW1PW MIN. MIN. 92FT92FT 95S95S NO SHEATHING JOINTS WITH IN THIS AREA 1PW1PW 16d @ 6" O.C. MAX NO SHEATHING JOINTS WITH IN THIS AREA 1PW1PW 1PW1PW 82L82L 12FD12FD 16d @ 6" O.C. MAX 61J61J 20H20H A34 @ 24" O.C. MAX REMOVE EXST. LATH & PLASTER 1 2SCALE 1/4" = 1' - 0"0 3 COMMON WALL CROSS SECT. DTL. 4 5 BUILDING SECTIONS AA & BB FOUNDATION PLAN, ROOF PLAN UPPER LEVEL FLR FRMNG PLAN, ROOF FRMNG PLAN REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: 7/30/2025 SHEET SIZE ARCHITECTURAL D A3 EXST. HOUSE EXST. HOUSE EXST. HOUSE EXST. HOUSE 10 4 5 E4E4 ROOFING MATERIAL ENHANCED WRB PLYWOOD SHEATHING R38 CAVITY INSULATION 2X12 RAFTERS 1/2" GYPSUM WALLBOARD EXTERIOR FINISH (CORTEN CORRUGATED SIDING ) R10 MINERAL FIBER CONTINUOUS INSULATION (ROCKWOOL OR SIMILAR) HORZ. GIRTS WITH 1/2" MINIMUM AIR SPACE ENHANCED WRB 1/2" PLYWD SHEATHING R13 CAVITY INSULATION 2X4 FRAMING 1/2" GWB RIM JOIST PER STRUCT. ENGR. P.T. PER STRUCT. ENGR. ANCHOR BOLT PER STRUCT. ENGR. FLOOR FINISH 3/4" T&G SUBFLOOR PER STRUCT. ENGR. FLOOR JOISTS PER STRUCT. ENGR. FLOOR FINISH 4" CONC. SLAB REINFORCED PER STRUCT. ENGR. 6 MIL POLYETHYLENE VAPOR BARRIER HYDRONIC PIPE CIRCUIT R10 FOAM UNDERSLAB INSUL. FINISHED GRADE 4" DIA. SCHED. 30 PVC PIPE W/ HOLES FACING DOWNWARD) MIN. METAL GUTTER ON 1 X 8 FASCIA ATTACHED TO 2 X 6 SUB-FASCIA EXTERIOR FINISH (CORTEN CORRUGATED SIDING) HORZ. GIRTS W/ 1/2" MIN. AIR SPACE ENHANCED WRB R24 INSULATED CONCRETE FORMWORK 6" CONC. WALL REINFORCE PER STUCT. ENGR. 1/2" GWB HORZ. ALUMINUM Z GIRTS @ 24" O.C. 4" 6" TIGHT-LINE DOWNSPOUT DRAIN GEO-TEXTILE FILTER FABRIC TO WRAP ENTIRE STONE BED 2X BELLY BAND W/ FLASHING CORRUGATED MTL.SIDING 6" ICF 1/2" G.W.B. 5/8" TYPE X G.W.B. 1/2" PLWD 1/2" LATH 2X4 FRAMING 1/2" LATH PLASTERCONC. ANCHOR PER ENGR. P.T. STUD PER STRUCT. ENGR. EXTERIOR FINISH (CORTEN CORRUGATED SIDING ) R10 MINERAL FIBER INSULATION (ROCKWOOL OR SIMILAR) HORZ. GIRTS WITH 1/2" MINIMUM AIR SPACE ENHANCED WRB 1/2" PLYWD SHEATHING R13 CAVITY INSULATION 2X4 FRAMING 1/2" GWB WINDOW TYP. WALL SECT., WINDOW WRAP WINDOW & GLASS DOOR GUARDS, STAIRS DETAILS DRAWINGS REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: WINDOW WRAP DETAILS WINDOW & GLASS DOOR GUARDS 7/30/2025 SHEET SIZE ARCHITECTURAL D TYP. ROOF, WALL, FLR. & FND. SECT. SCALE: NONE 3 TYP. HANDRAIL PROFILES A4 SCALE: NONE 5 SCALE: NONE SCALE: NONE1SCALE: NONE D2 4 2 SCALE: NONE 9 SCALE: NONE SCALE: NONE SCALE: NONE 10 6TYP. STAIR SECTIONTYP. STAIR ELEVATION TYP. HANDRAIL ELEVATION TYP. GUARD ELEVATION SCALE: 11/2" = 1'- 0"D1ICF / FRAMED WALL CONNECTION WALL CORNER CONNECTION 2708J Ave Small Site Construction SWPPP.docx Updated 8/28/2023 page 1 of 6 Permit #: Received by: Small Site Construction SWPPP City of Anacortes Stormwater · 904 6th Street · Anacortes, WA 98221 Stormwater inspector: 360-630-1037 General Information Project Name Jed Brich Addition Parcel Size 0.31 acres Project Address 2708 J Avenue Property Owner Jed Brich Phone 360-391-6272 Site Contact Jed Brich Phone 360-391-6272 Project Description Describe the nature and purpose of the construction project. Include the total size of the area, any increase in existing impervious area; the total area expected to be disturbed by clearing, grading, excavation or other construction activities, including off-site borrow and fill areas; and the volumes of grading cut and fill that are proposed. This project will demolish a 160 square foot concrete patio, 80 square foot shed, and 162 square foot existing addition (402 square feet total). The project will then construct a new 384 square foot addition in the same location. Erosion control lead or responsible party Jed Brich Phone 360-391-6272 Engineer/Firm Herrigstad Engineering PS Phone 360-299-8804 **************************************************************** I acknowledge that I have read the information presented to me and agree to abide by the BMP rules. __Jed Brich_____ _____________________ Printed name Signature ______________________ Date **************************************************************** Site Conditions Adjacent Areas. See the site plan, drainage plan, and construction drawings approved for the associated permit. Critical areas. See the critical areas site plan approved for the associated permit.  Attach a copy of your stormwater site plan submitted with your building/grading permit application and attach pictures of construction site. *Stormwater site plan shall list all BMPs for inspectors BLD-2024-0857 Aaron Esterholt Stormwater Review 2708J Ave Small Site Construction SWPPP.docx Updated 8/28/2023 page 2 of 6 2708J Ave Small Site Construction SWPPP.docx Updated 8/28/2023 page 3 of 6 Best Management Practices Illustration Turn the page to see information corresponding to each numbered circle below. About this Pollution Prevention Plan This is Anacortes’s Small Site Construction Stormwater Pollution Prevention Plan (“Construction SWPPP”) intended to ensure your construction project minimizes erosion and does not contribute pollution, including sediment, to stormwater. This SWPPP is primarily intended for projects under 2,000 sq ft. This plan uses certain Best Management Practices (“BMPs”) from the Stormwater Management Manual. Some detailed descriptions are included; the remainder and additional information are available at https://fortress.wa.gov/ecy/publications/parts/1410055pa rt4.pdf#page=27 The listed BMPs are the minimum necessary; if erosion occurs, you must add additional BMPs as necessary to control it. You should include your Construction SWPPP in your contract with your builder. You must keep a copy of this SWPPP on the construction site or within reasonable access to the site for construction and inspection personnel at all times. Property owners and contractors are responsible for ensuring all aspects of BMPs are followed, including those not shown on the detail sheets. This Construction SWPPP should be considered a living document and must be updated as needed to reflect site conditions. Preserve Vegetation/Mark Clearing Limits Before any land disturbance, including clearing and grading, clearly mark all clearing limits, sensitive areas and their buffers, and trees that are to be preserved within the construction area. Retain natural vegetation in an undisturbed state to the maximum extent practical. Use these BMPs:  C101 to preserve natural vegetation  C102 to establish buffer zones around important vegetation you want to save  C103 High Visibility Fencing to mark the boundaries of your buffers  C233 Silt Fence to ensure sediment doesn’t leave the site Establish Construction Access Construction vehicles can damage or compact soils, create sediment pollution, or track sediment onto public roads. All equipment and vehicles that access the construction area must use an existing driveway or a stabilized construction entrance.  Use BMP C105 Stabilized Construction Entrance wherever traffic will be entering or leaving a construction site if paved roads are within 1,000 ft of the site. Construct a 12-inch thick pad of 4-inch to 8- inch quarry spalls, a 4-inch course of asphalt treated base, or use existing pavement. Place a separation 2 1 1b 1b 1b 2 1a 4 7 9a 9b 5 9b 2708J Ave Small Site Construction SWPPP.docx Updated 8/28/2023 page 4 of 6 geotextile under the spalls to prevent fine sediment from pumping up into the rock pad. Install the construction entrance prior to any vehicles entering the site, at the location shown on the site plan. Create only one construction entrance per site.  Use BMP C103 High Visibility Fencing to restrict traffic to the construction entrance.  Remove any sediment that is tracked onto pavement by shoveling or street sweeping and remove the collected sediment or stabilize it on site. Control Flow Rates (not shown) Stormwater on a cleared site can create significant flows that can damage downstream properties. Protect properties and waterways downstream of the project site from erosion and the associated discharge of turbid waters. If your project is required to control flow rates, you must use the following BMPs as shown on the approved site plan:  C203 Water Bars  C209 Outlet Protection  C235 Straw Wattles Install Sediment Controls When land is cleared of vegetation, stormwater can pick up sediment, a pollutant. BMPs can prevent sediment from leaving the site. You must install sediment controls before land disturbance to effectively minimize and control the discharge of pollutants and sediments. Use and properly install BMP C233 Silt Fence. You must bury the filter fabric as shown in the diagram in order for the BMP to be effective. You must repair the silt fence if it is damaged. Consider the following additional BMPs:  C231 Brush Barrier  C232 Gravel Filter Berm  C234 Vegetated Strip  C235 Straw Wattles Note that C230 Straw Bale Barrier is no longer an approved BMP. Stabilize Soils Leaving soils devegetated or exposed needlessly creates erosion and sediment problems.  Stabilize all exposed soils whenever construction work will stop for more than two days at a time during the wet season (October 1 to April 30) or 7 days the rest of the year (the dry season).  Stabilize all exposed soils at the end of the shift before a holiday or weekend.  Stabilize all exposed soils with either vegetation, mat coverings, mulching, or in those areas to be paved, a compacted base material.  Use BMP C123 Plastic Covering over all stockpiles with plastic or burlap if left unworked. Place sand- filled burlap or geotextile bags every 3 to 6 ft along seams and tie them together with twine to hold them in place.  If you excavate soil for the foundation, backfill that soil against the foundation and grade it to drain away from the building. Once the disturbed landscape areas are graded, you must seed or sod the grass areas. Consider the following additional BMPs:  C120 Temporary and Permanent Seeding  C121 Mulching  C122 Nets and Blankets  C124 Sodding  C125 Topsoiling/Composting  C131 Gradient Terraces  C140 Dust Control Protect Slopes (not shown) Slopes can be especially vulnerable to erosion, but BMPs can mitigate sediment problems. Design and construct cut-and-fill slopes to minimize erosion. Use the following practices:  Reduce continuous length of slope with terracing and diversions  Reduce slope steepness  Roughen slope surfaces  Use BMP C123 Plastic Covering over all exposed slopes  Use BMP C120 Temporary and Permanent Seeding as soon as possible on exposed slopes Manage off-site stormwater (run-on) separately from stormwater generated onsite. Divert off-site stormwater or groundwater away from slopes and disturbed areas with interceptor dikes, pipes, or swales. You may not create cut slopes over 4 feet high or slopes steeper than 2 feet horizontal to 1 foot vertical. Fill slopes may not exceed 4 feet high or 3 feet horizontal to 1 foot vertical. Slopes that exceed these criteria require engineering. Consider the following additional BMPs:  C121 Mulching  C122 Nets and Blankets  C124 Sodding  C203 Water Bars 6 5 4 3 2708J Ave Small Site Construction SWPPP.docx Updated 8/28/2023 page 5 of 6  C208 Triangular Silt Dike (Geotextile‐Encased Check Dam Protect Drain Inlets Storm drains are designed to collect and transport clean stormwater, not water contaminated with sediment or other pollutants. Storm drain inlets must be protected so that runoff does not enter the stormwater system without first being filtered or treated or both.  Use BMP C220 Storm Drain Inlet Protection to protect all proposed and existing storm drain inlets during construction so that stormwater runoff does not enter the stormwater conveyance system without first being filtered or treated (or both) to remove sediment or other pollutants.  Clean or remove and replace inlet protection devices when sediment has filled one-third of the available storage (unless a different standard is specified by the product manufacturer).  Keep all approach roads clean.  Do not allow sediment and street wash water to enter storm drains without treatment. Stabilize Channels and Outlets Stormwater channels and outlets can themselves erode unless stabilized with rock or other armoring. Design, construct, and stabilize all on-site conveyance channels to prevent erosion as needed. Use BMP C209 Outlet Protection to provide stabilization, including armoring material adequate to prevent erosion of outlets, adjacent streambanks, slopes, and downstream reaches at the outlets of all conveyance systems. Consider the following additional BMPs:  C122 Nets and Blankets  C202 Channel Lining Control Pollutants Waste materials, demolition debris, and other pollutants that occur onsite during construction can contaminate the stormwater system unless managed. Cement and related products can modify the pH of stormwater. Provide cover, containment, and protection from vandalism for all chemicals, liquid products, petroleum products, and other materials that have the potential to pose a threat to human health or the environment. Anytime you pour concrete, perform washout of the concrete trucks following BMP C154 Concrete Washout Area at designated washout areas only. Locate washout areas at least 50 ft from sensitive areas such as storm drains, open ditches, or water bodies, including wetlands. Clean contaminated surfaces immediately following any spill incident. Apply fertilizers and pesticides in a manner and at rates that will not result in loss of chemical via stormwater runoff. Use the following additional BMPs:  C151 Concrete Handling  C152 Sawcutting and Surfacing Pollution Prevention  C153 Material Storage, Delivery, and Containment Control De-Watering (not shown) De-watering water extracted from foundations, vaults, or trenches, has similar characteristics to stormwater runoff at the site and can cause the same impacts unless properly managed. You may discharge clean, non-turbid de-watering, such as well-point ground water, to systems that are tributaries to, or directly into, surface waters if the de- watering flow does not cause erosion or flooding or interfere with the operation of the stormwater system. Use the following BMPs:  C220 Storm Drain Inlet Protection  C236 Vegetative Filtration Maintain BMPs (not shown) All temporary and permanent erosion and sediment control BMPs must be maintained and repaired as needed to assure continued performance of their intended function. During the dry season, inspect sediment control BMPs weekly or after a runoff-producing storm event. During the wet season, inspect BMPs daily. Use BMP C150 Materials on Hand to ensure you are ready for a heavy rain. All temporary erosion and sediment control BMPs must be removed within 30 days after the City determines that the site is stabilized or after the temporary BMPs are no longer needed. Trapped sediment must be removed or stabilized on site. Disturbed soil areas resulting from removal of BMPs or vegetation must be permanently stabilized. Manage the Project (not shown) Phasing a project, especially when revegetation occurs as part of each phase, can help prevent the transport of sediment from the site.  Fully implement this Construction SWPPP at all times. 12 11 10 9 8 7 2708J Ave Small Site Construction SWPPP.docx Updated 8/28/2023 page 6 of 6  Modify this Construction SWPPP whenever there is a change in design, construction, operation, or maintenance at the construction site that has or could have a significant effect on the discharge of pollutants to waters of the state.  Inspect, maintain, and repair all BMPs as needed to ensure continued performance of their intended function. Protect Low-Impact Development BMPs Low-Impact Development techniques can be damaged if they are compacted or accumulate sediment during construction. If there are any Low-Impact Development BMPs planned for the site:  Use BMP C103 High Visibility Fence to exclude all construction and foot traffic from the infiltration, bio- retention, or rain garden areas.  Protect all infiltration areas or bio-retention and rain garden BMPs from sedimentation through installation and maintenance of erosion and sediment control BMPs on portions of the site that drain into those areas.  Use BMP C233 Silt Fence or C234 Vegetated Strip to control and avoid introducing sediment onto permeable pavements. Bury the bottom of the filter fabric at least 4 inches below the ground surface. Backfill and tamp soil in place over the buried portion of the filter fabric, so that no flow can pass beneath the fence and scouring cannot occur. Drive or place the fence posts into the ground at least 18 inches. A 12-inch minimum depth is allowed if topsoil or other soft subgrade soil is not present and 18 inches cannot be reached.  If pavements are fouled with sediments or no longer pass an initial infiltration test, clean them using procedures from the Stormwater Manual or the manufacturer’s procedures. Consider the following additional BMPs:  C102 Buffer Zones  C208 Triangular Silt Dike  C231 Brush Barries 13 EXST. HOUSE 820.35 SQ FT EXST. DECK 111.46 SQ FT EXST. SHOP1,269.29 SQ FT 11' S0° 1' 47"E 283' S89° 47' 58"W 11' N0° 27' 22"W 283' N89° 47' 58"EPARCEL NUMBER P57872 LOT SIZE: 3,157.31 SQ FT SSSSSSSSSSSSSSSSSSSSSSSS SS SS GRAVEL DRIVEWAY 2,187.74 SQ FT M G G W W W W W W WWWWWWWWWWWWWWWWWWWWWWWUPUPUPUPUPUPUPUPUPUPUPUPUPUP UP UP UP UP W W W UP UP 146'144'148'150' EXST. GUEST HOUSE 702.2 SQ FT G G G G G G G G G G G G G GG ADDITION 383.97 SQ FT 40' S0° 1' 47"E 283' S89° 47' 58"W 39' N0° 27' 22"W 283' N89° 32' 57"E PARCEL NUMBER P31827 LOT SIZE: 11,161.75 SQ FT 24" DIA. CEDAR24" DIA. CEDAR 36.5' 5' 20' 38.78' 7.5'1.56' J AVENUE 2ND STORY SETBACK3" DIA. CEDAR EXST. HOUSE 820.35 SQ FT PARCEL NUMBERS P31827 & P57872 2708 AVENUELOT SIZE: 13,475.3 SQ FT EXST. DECK 111.46 SQ FT GRAVEL DRIVEWAY 2,187.74 SQ FT DEMO'D SHED 80 SQ FT DEMO'D ADDITION 162.67 SQ FT DEMO'D PATIO 160 SQ FT N SITE PLAN SCALE 1" = 10'0 5 10 20 GGG W W SS SS OP OP OP ST ST ST OC OC X X X W M E G C UP UP UP SITE PLAN LEGEND WATER SANITARY SEWER OVERHEAD POWER NATURAL GAS STORM SEWER OVERHEAD COMM. ELECTRIC METER ELECTRIC SERVICE TELEPHONE & CABLE SERVICE GAS METER WATER METER SILT FENCE SHEET FLOW DIRECTION SETBACK LINE PROPERTY LINE CONTOUR LINE UNDER GROUND POWER ADDITIONA B C D AVG. ORIG. GRADE. DIAGRAM SITE PLAN REVISION TABLE NUM. DATE REV. BY DESCRIPTION DRAWINGS PROVIDED BY: CURRIE DESIGN GROUP, LLC 3916 S AVENUE ANACORTES, WA 98221 360-941-1789 SHEET: JED BRICH ADDITION 2708 J AVENUE ANACORTES, WA 98221 PAYMENT OF USE FEE IS DUE TO NIMBLE STRUCTURES, LLC PRIOR TO CONSTRUCTION FOR EACH STRUCTURE BUILT FROM THESE PLANS. THESE PLANS ARE COPYRIGHTED IN ACCORDANCE WITH FEDERAL STATUTES. REPRODUCTION BY ANY METHOD OF ALL OR PORTIONS OF THESE PLANS OR VARIATIONS THEREOF WITHOUT WRITTEN PERMISSION FROM NIMBLE STRUCTURES, LLC IS STRICTLY PROHIBITED. THESE DRAWINGS AND PLANS SET FORTH ON THIS SHEET AS INSTRUMENTS OF SERVICE ARE, AND SHALL REMAIN, THE PROPERTY OF NIMBLE STRUCTURES, LLC. DATE: 7/30/2025 SHEET SIZE ARCHITECTURAL D C2 LOT COVERAGE CALCULATIONS LOT AREA                   13,475.3 SF   LOT COVERAGE EXST. RESIDENCE                        820.4 SF PROPOSED ADDITION                    385.3 SF EXST. RESIDENCE DECK 111.5 SF EXST. GUEST HOUSE 702.2 SF EXST. SHOP 1,269.3 SF TOTAL                                   3,288.7 SF BUILDING %                               24.4 % MAXIMUM BUILDING %                   35.0 %   IMPERVIOUS SURFACES EXST. RESIDENCE                        820.4 SF PROPOSED ADDITION                    385.3 SF EXST. RESIDENCE DECK 111.5 SF EXST. GUEST HOUSE 702.2 SF EXST. SHOP 1,269.3 SF DRIVEWAYS                       2,187.7 SF TOTAL IMPERVIOUS AREA              5,476.4 SF TOTAL IMPERVIOUS %                    40.6 % MAXIMUM ALLOWED %                   45.0 % SITE PLAN NOTES 1.SEWER: WILL BE CONNECTED TO THE EXISTING STUB AS SHOWN. 2.WATER: WILL BE CONNECTED TO THE EXISTING METER AS SHOWN. 3.POWER: WILL BE CONNECTED TO THE EXISTING METER AS SHOWN. 4.COMMUNICATION LINES: WILL BE CONNECTED TO THE EXISTING METER AS SHOWN. 5.STORM:  ROOF GUTTER DOWNSPOUTS WILL BE CONNECTED TO EXISTING TIGHT LINE SYSTEM 6.FOOTING DRAINS: EXISTING FOOTING DRAINS WILL BE INSPECTED WHERE FEASIBLE 7.DURING CONSTRUCTION, THE RUNOFF WILL BE CONTROLLED WITH SILT FENCES AND SHALLOW SWALES TO PROTECT THE ADJACENT DOWNSTREAM PROPERTIES. 8.IF A DOWNSTREAM DRAINAGE SYSTEM IS PRESENT INSTALL CATCH BASIN INSERTS (DOE BMP) TO CATCH ADDITIONAL SEDIMENT THAT MAKES IT TO THE STREET. 9.STREETS AND DITCHES WILL BE CLEANED DAILY OF EROSION RUNOFF, IF ANY. 10.BEFORE CONSTRUCTION BEGINS, A SITE WALK WILL TAKE PLACE TO IDENTIFY THE CONDITION OF THE STREET, CURB AND GUTTER AND SIDEWALKS.  ALL BROKEN AREAS WILL BE REPLACED TO THE CITY’S APPROVAL PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. AVERAGE ORIGINAL GRADE AVG. ORG. SIDE ELEV. FT.LGTH. FT. ELEV * LGTH GRADE A 146.3 24.0 3,511.2 B 146.0 16.0 2,336.0 C 145.8 24.0 3,499.2 D 146.2 16.0 2,339.2 80.0 11,685.6 146.1 SITE PLAN - DEMO SCALE 1" = 10'0 5 10 20