HomeMy WebLinkAboutDOC-2010-Plans Mechanical - �^2 4 2x6 brg wail 5 6 7 8 I 2x4 brg wall 1.0 11 12 see B/A4 for see A/A16 I see B/A16 floor framing Z3 at Connection 2x4 brg wall 2x4 brg wall 2x6 brg wall 2x4 brg wall 2x6 brg wall see B/A16 see B/A16 see A/A16 see B/A16 see A/A16 2x4 brg wall Beam Schedule " HZsee B/A160). TT�/ 0 -- g� a Q a No. Qty Nominal Size Dressed Size Grade a o 0 io A 5x8 5 1 2 x 7 1 4 DFL #2 T B 3 1 2 x 9 1 2 same 2.0 E PSL C 5 1 4 x 9 1 2 same 2.0 E PSL • _ D 48 3 11/2 x 7 1 4 DFL #2 '® PSL Coll ° E 3 1 4 x 11 7 8 same 2.0 E PSL .0 o F 5 1 4 x 11 7 8 same 2.0 E PSL ❑° G 5 1 4 x 9 1 2 same 2.0 E PSL ® o H B 3 4 x i3.5 same 1.8 E DF F G18 T � 4x4 T �- 5 x5 (�: PSL co s° 20 _o o c go gx6 ' ° 1) provide (2) layers 5/8" type X GWB wrap all beams c° to to to 2) no wrap required at door and window heads ®i ® x 3) provide posts or gang studs as indicated with �-- - continuous blocking providing full bearing between floor: N ; to N 4) provide Simpson CS16 strap each end where any ;o ;o ;o . o beams are installed without a continuous top plate 0 00 6x6 00 0 0 4x6 4x6 � .41 —7 11o_ o ca a o ILI r T 6x6 3/4" PWD floor (j structural H x6 F 46 bracket T r T (2) layers 5/8" type X GWB 41 00 11 TJI 110 ® Ille TJI 110 all sides joists 16"oc joists ® 16"oc fire tape only •+� MMMML X4.1 continuous wall �J 0 2x6 LSL studs 0 16"oc °J 'kn " see Floor Plans for extent of rated wall hatch indicates 1 hr fire rated 8" 4) 00 see E/A16 for detail 4x4 E joist cavity for dryer exhaust o c (2) layers 5/8" type X GWB 4 c 4x4 PT 4x6 I see C/A3 3/4" APA rated T&G subflr-finflr, glue and nail w/ 8d common nails w PB46 " c� � 6 oc diaphragm boundaries, 6"oc panel edges & 12 oc field continuous 1x4 lay-out as indicated per IBC case 1 & 3 each side 00 U� (unblocked diaphragm) except as directed by joist mfr (typical at all wood floors) 16" 5/8" GWB Second Floor Framing Plan Rated CavityPSL col Bstipple indicates AS I stipple indicates J 1/8�=1�-0� 8" concrete wall 118 8" concrete wall 3/40=1"-O' see D/A2 similar IL resident sJ§rage see D/A2 similar (non—insulated) 540 sf Sams—heated E bldental use (non—insulated) All Exterior Walls (fire separation distance > 5') E w/ automatic fire—extin fishing system ,�+ A8 1 hour rated from inside only per IBC 704 A8 of=3 20Dsfocc waterproofing membrane detail Table 720.1 2 Item 16-1.3 �� m prescriptive ( } � 5�"x5�" `j � metal flashing 4"/2"/4" "Z" 1 2 3 4 5 6 7 8 9 10 11 II 12 PSL col '','. 13 14 � (dk brnz or galy) 11'-6N' 15'-0" 13'--0" 13'-0" 15'-0" 15'-0" 10'-O" 12'-0" 15'-0" 13'-O" 13'-0" 15'-0'': 10'-0" topsoil sidewalk or grass S'-9" 661" Ok" 5'-9" 8 " 5'-9" 43�" 8'-9" 817 8'-9" 6'-7' 5'-9" 4' 9" 5'-9" 3 -7 " his stipple indicates ; 60V 20Y4" 8" concrete wall 1 hour I field 3'-2°' see D/A2 dashed line a Q 5 " 5 " bearing wall 20 verify indicates N n 20y4 :...::..::.::.::•:::.::::.•.::. spa n adhere 2" rigid insulation ex en f A 1 59 5 x5J siol s rar ion adhere rigid vinyl or �r A A A A A A A A A 02 5J"x5 " ' PSL col cq detail D/A3 galy sheet metal face d a d = PSL col :::•:::•:::•:::•::::::•:::•:::•:::•:::•. l :•:::•:::•::: ::•.::•.:::::•:::•:: .::•:::•: • •,:•::. :•:::•.., rain rock m filter fabric o low wall " " to 36"aff 125E 20 x 4 2 drain r 4x4 nonrated o extend drain mat o a one bedroom Type B 25 one bedroom Type A two bedroom Type A os 125 Storage shaft I 11 :! c•l " corner apartment 23 interior apartment interior apartment 34 corridor IL resident ,89 112 of I. T 10 —fl see C A13 sim 23 see A/A14 see B/A14 116 5J"x5 " - 141 29 143 145 electrical PSL col exercise room Cd • !� concrete 4x4 room o I assembly 658 sf PT 2x4 stud wail Soil Separation plinth 32 I accessary occupancy • _ _ _ _ _ 117 w/ R•-••13 insul N C � a n 4x4 4x4 electrical OL 44 5sf/occ stipple indi ates Nat entry " win w panels (for exiting from room) 125A 8" concret wall West Watt io 22% 2 26 4x4 4x4 10 6x6 IL resident see D/A2 D �_ 1_ s -,�•••� b 38" 24 33 PSL col low wail therapist office (2) sayers 0# 3�4 -" , 0 T 3 u ADA ADA to 36 aff 22 28 31 toilet DF " " 188 53 :s felt at can rete •" of w 11 5 x5 Y2 `: entry slab 4x6Q 11 PSL col ,2 6x6 11)7 :.:::...........:,..:::.::..:: Wall Typ e Legend � � e recessed 3}�" 57}J" Corridor Walls 6x6 4x6 Walls Separating 6x6 4x6 4x6 6x6 4x6 Vertical 13 rescue q o � #� fir mat o 1 hour rated Dwellingknits corridor sY• o Exit Enclosure A ® exterior wail I I IIH I I 367 sf I) ao II elevator shaft �I H ® yp / �1 stair Fire Partitions 1 hour rated r I 1 hour rated l 1 hour rated stair see Typical Wall Section C A11 + `h t4� 100 0s r` Fire Partitions 111 Fire Barrier ® 1 hour fire-rated Fire Partition c 6x6 4x6 6x6 0 4x6 6 Fire Barrier .6x6 4x6 6x6 see D A16 115 _ �I co x6 20 see D/A16 ICC 708.4 exception 5 r- I al 4x6 ® a 18 1s 15 14 I �J from floor to underside of 1 hour elevator 6x6 o U c14 = 49 43 trash � ility laundry _; ci fire-rated fl[or/ceiling or floor 113 AMEE 40pp m0 n incidental use 124 roof/ceiling assembly above 1 51 5 forced air I 120 18 w/ automatic 6x6 See Detail A/A16 furnace a elevator c x#inguis IL resident Y ❑ 54 47 $ ❑ 21 114 , " s ern TV-room �w { ® 1 hour fire-rated structural wall exterior wall w/o w/b 112 $ -O 7 -2 washer stair � assembly 653 sf x from floor to underside of 1 hour _ mechanica[ shaft 122 accessory occupancy r� ` _ fire-rated floor/ceiling assembly above of exit `o < 1OX floor area 1 enclosure T � o w/o 1 hour rated o ( _ ) � --O See Detail B/Alin 1 hr from crosshatch B cc 0 3s Fire Barrier dryer co (for exitingfrom room) inside except indicates 4 PT 2x4 stud wall A p one bedroom `type 6 one bedroom Type B � 38 mechanical i ; ® non-rated nonbearing as indicated Ve tical corner apartment 50 44 interior apartment 121 boiler room 17 staff lockers I w/ -13 insul interior partition wall Exit Enclosure see C/A13 52 46 see A A13 sim 4x4 incidental use 6x6 I ICC TBL 601 i i 2 hour rated / by Owner (NIC) T Fire Barrier 142 w/ automatic � See Detail C/A16 144 4x4 4x6 fire-extinguishing future shows PT see E A16 (rough-in a ly) 5s V4x6 1 hour fire-rated (4 stories) Q — = 37 system housekeeping Fire Barrier & Shaft Enclosure Date: A A A A A 4x6 4x4 41 storage ICC 706.5 & 707.5 Continuous from g,C Q two bedroom Type B turn closet floor to underside of floor above 123 dashed line � See Detail D/A16 01/15/10 corner apartment 3s indicates S see D/A13 extent of �:J revised 62/01/10 HVAC L x 2 hour fire-rated revisec102/26110 stipple indicates siol separar ion o Fire Barrier & Shaft Enclosure 146 4x4 condenser „ detail D A3 c0 gas meter 8 concrete wall / [CC 706.5 & 707.5 Continuous from see D/A2 J floor to underside of floor above �q Aa d See Detail E/A16 2 hour fire-rated Fire Wail Sheet: 8 15" 8 " Separating Buildings 8'-9" 66Y2" 43X* 5'-9" 7' 3" 5'-9" 43Y2" 8'-9" 5'-0" 8'-9" 7'-8" 5'-9" 4'-9" 5'-9" QY2 ICC 705.5 to noncombustible siding e. ICC 705.6.1 from floor to underside A " ' " " „ „ „ „ " of 1 hour fire-rated roof assembly A 15 -0 13-0 13 -0 15 -O 37 -0 15 -Q 13 -0 13 -0 15 -Q 10 -0 See Detail F/A16 ILI � First Entrance Security System Floor Plan Note• Coordinate with Shear Wall Types by Owner under separate contract B C V D E F Coordinate Size, Type, and Location Contractor to coordinate work. A of Fire Extinguishers with Local Fire Chief See Structural Drawings 1/8'=1'--D" Rt • _ Room Finish Schedule nmowe sank. appliances, & cabmtry cap ,roar er serer rwnow deetrkal Existing number name floor walls ceiling p �"` b0°ie' °` wed Building F chr rail material undrloymnt base material finish crwn trim material . ,call k0tai 16 : Existing Corridor W2pF� bean, 100 stair carpet glue dwn 1x4 wd GWB PT GWB/GWB/resil channels177_,,. ram. Ir or 4 haw G1VM wrap 111 corridor carpet glue dwn 1x4 wd GWB PT yes GWB/GWB/resil channels rlcils beam p�od1et B �x� 4cc 112 furnace sht vinyl APA PWD vinyl cove GWB PT GWB/GWB/resil channels wrap �tDe00� "ia11doors D ncrete slab—on—grade 113 trash sht vinyl APA PWD vinyl cove GWB PT GWB/GWB/resil channels as A2 concrete stemwall by ar1C- 114 elevator concrete pit GWB tape fy 115 stair carpet glue dwn 1 x4 wd GWB PT GWB/GWB/reall channels _ oa water nofttum w 116 corridor carpet glue dwn 1x4 wd GWB PT yes GWB/GWB/resii channels A2on wae � r>Eto l � � base. PT ledger secure to cone r ■ w/ Simpson Titten HD 5/8 x6 117 electrical room concrete vinyl cove GWB PT GWB/GWB/resii channels � � 0 16'oc stagger 118 unheated storage concrete PT GWB/GWB/resii channels bemr,I GX6POC @ our info � wd 1 havr "°� secure post to cone wall " 1 Into am well w/ 5/8 x 8 Titen HD 0 16 oc 1l 119 ADA toilet sht vinyl APA PWD vinyl cove WR GWB PT GWB/GWB/resit channels a=»" 5 1/4 x 9 1/2 PSL beam .a lines to a 120 elevator meth concrete vinyl cove GWB PT GWB/GWB/resil channels Corridor lnteder wails to removed LSL rim joist at intermediate bearing I mil; match at provide continuous LSL 121 mechanical/boiler concrete vinyl cove GWB PT GWB/GWB/resil channels haw a PT sill plate on blocking between joists 122 facilitylaundrgo 11 y concrete stemwall 11 7 ' . Y concrete vinyl cove GWB PT GWB/GWB/resit channels h now rasa Storage below /8 TJl 110 " r r � ■ Existing Building na.r floor joists 0 16 oc —51� 7—8N4 9 —4Y4 g g r--a 123 housekeeping concrete vinyl cove GWB PT GWB/GWB/resil channels 1�dent- use D ® 6x6 C) 124 resident rec—room carpet glue dwn 1 x4 wd GWB PT GWB/GWB/resil channels A2 c A2 125 resident storage concrete vinyl cove GWB PT GWB/GWB/resil channels LSL rim joist 6x6 6x6 w/ 200 stair carpet glue dwn 1 x4 wd GWB PT GWB/GWB/resii channels 1 hour PT sill plate on Corridor wrap 211 corridor carpet glue dwn 1 x4 wd GWB PT yes GWB/GWB/resil channels 3/4" APA rated T&G subfir—fin concrete stemwall below 221 212 furnace sht vinyl APA PWD GWB PT GWB/GWB/resit channels Remodel o glue and nail w/ Sd common nails lxlhorurg rated .� 213 trash sht vinyl APA PWD vinyl cove GWB PT GWB/GWB/resil channels 0 6"oc diaphragm boundaries secure post to conc — T =Z!i Apartment 6 oc panel edges & 12 oc field wall w/ 5/8" x 8" existing ceilin 214 elevator GWB tape lay—out as Indicated Independent g g 1 hour N per IBC case 1 & 3 Titen HD 0 16"oc 1 hour rated 00 215 stair carpet glue dwn 1x4 wd GWB PT GWB/GWB/resii channels t Connection Living Lobby (field verify) �stOrage 216 lobby carpet glue dwn 1 x4 wd GWB PT yes GWB/GWB/resii channels Second Floor existing wall 170sf ._ .r, . 217 corridor carpet glue dwn 1x4 wd GWB PT yes GWB/GWB/resii channels �� —i 1 hour rated Incidental use �• rT� Plan work int Fr—i � a° 218 ADA toilet sht vinyl APA PWD vinyl cove WR GWB PT GWB/GWB/resil channels ra n g 48" 23'-11 220 poi # 0 C ex window mb work 010 219 connection carpet glue dwn 1x4 wd GWB PT GWB/GWB/resit channels c (fv) F exg wind w jamb ;--4 g carpet g , / a t Connection 22D storage remodel ca et glue dwn 1x4 wd GWB PT GWB GWB resii channels 57 221 corridor remodel carpet glue dwn 1x4 wd GWB PT GWB/GWB/resil channels 1/8'=V-0• Z. , = n C> o Ln ¢, 222 dining see A/17 carpet glue dwn 1x4 wd GWB PT GWB/GWB/resit channels Note: IBC 705.5.2 Exception 3 cal" For combustible roof overhangs within 4 feet of the firo wall with concealed spaces,, the fire �p Separate Buildings j 300 stair carpet glue dwn 1x4 wd GWB PT GWB/GWB/resil channels wall shall extend through the concealed space to the outer edges of the overhang. ° 2 hour rated Fire Wall ° 311 corridor carpet glue dwn 1x4 wd GWB PT yes GWB/GWB/resii channels SOLID WALL INDICATES per ISC 705.5.1 Where the fire wall intersects the exterior walls the B to the underside of B exterior walls on both aides of the fire wall shall have a 1 hour firs realstonce rating extending a i hour roof assembly 312 furnace sht vinyl APA PWD vinyl cove GWB PT GWB/GWB/resil channels minimum of 4 feet on each side of the interoection of the firewdl. install wall par UL Design No. U301 continue through exterior wall and 313 trash sht vinyl APA PWD vinyl cove GWB PT GWB/GWB/resii channels Note: Install wall per UL Design No. U305 I roof framing to odarlor sheathing 4x4 1 0 / / FRAMING— 2x4 etude minimum O 16'oc maximum. N provide at concealed roof overhang Cedar Nis 314 elevator GWB toe GWB GWB resit channels ■ r r INSIDE FACE— 5/a type C USG Gypsum panels nallod to all framing 0 7'oc w/ 6d cement ° �B NB 9 past 315 stair carpet glue dwn 1x4 wd GWB PT GWB/GWB/resil channels coated nails 1-7/6" long, 0.0915' shank diameter. and 15/64' diameter heads. Connection OUTSIDE FACE— 5/0" type SHX USG Gypsum sheathing panels nalled to all framing O 7"oc w/ = 843 sf Assembly 316 balcony paint It wt conc point GWB PT GWB/GWB/resil channels 6d cement coated nails 1-7/a' tong, 0.09150 shank diameter, 15/16' diameter heads. [V qp Accessory Occupancy QB 4 O : w 05 (< 10% of floor area) O► 400 viewing carpet glue dwn 1x4 wd GWB PT GWB/GWB/resil channels All Exterior Walls (fire separation distance > 5') aL-121 0 7sf/acc (for exiting from room) .� A8 1 hour rated from inside only per IBC 704 , B B ° to prescriptive detail Table 720.1(2) Item 16-1.3 A8 219 [/tg _ 1 36" 11'-6V 15'-0" 13'-0" 13'-0" 15'-0" 15'-0" 10'—Q" 12'-0" 15'-0" °a Corridor Walls co WLr 15" 1 hour rated 10 V Firs Partitions B 66X* 43X" 5'-9" 8 " 5'-9" 43 8'-9" 81�s $�-9' 6`-7 5'-9" 4' 9" 5'-9" 437 " 5'-0" 8'-9' 43V S'-9�' 32' built—In storage ° A 15■ (fi+) p� 00 A _ ADA 33"60 _ toilet 1 B 21 B wJ A 6x6 4x6 a' 4x4 4x6 seat �..� 1 one bedroom Type B B _ • I � YP 67 73 one bedroom TypI wo bedroom Type B one bedroom Type B O � I � � 10-C 4 '-0" corner apartment Bg 71 interior apartmeinterior apartment interior apartment corridor 4x6 9'-9Y4" CO04 see C Al3 sim see A/A13see B/A13 see A/A13 sim 217 • 241 243 245 247 two wing Lobby 4x4 77 � sided Living Lobby concre e _ — = constucted as plinth C ❑° fireplace 1 hour rated �,++�� 4""� 4x4 F/A14 o extent of w� corridor entry = 1 Olt = = rated wall g w/b °�° 5 rn � per IBC 74 4x4 87 350 sf 22�4 216 r M o = I `� 1020.1.4 66 O OL 78 85 38 exter�or wall r entry mail 1 hr fi' 1i insi a �� Wall Type Legend � below o 64 7a o 0 76 w o n s wall 04 I hr t as insi ates ® O 0 0 ARFZ I O 4x6 r boxes A , ® exterior wall 36 off D LV see Typical Wall Section G A11 rescue 4x6 6x6 4x6 6x6 4x6 4x6 6x6 4x6 fix6 Vertical ecesse � / _ _ � Q ❑ '� Corridor Walls Walls Separating 61 = corridor ,Exit © _ ll 1 hour rated II I Dwelling Units a Enclosure ® 1 hour fire—rated Fire Partition �n 1 stair ��, t. I 1 hour rated II 367 sf II oo I� elevator shaft 1I II II 1 I 1 hour rated ® stair l C Fire Partitions l 1 hour rated n Fire Barrier ICC 708.4 exception 5 rn © ` 'n to a 2 00 Fire Partitions 211 4x6 °D 6 Fire Barrier fix6 4x6 6x6 see D A16 215 Qm from floor to underside of 1 hour 0 4x6 6x6 4x6 6x6 / fire—rated fllor/ceiling or x6 62 see D/A16 m roof/ceiling assembly above 00 Z5 Co 00 OZ5 1 1 0 1�5 1 o 1 Z`J ~� See Detail A/A16 exterior wail O 114 108 O floor yssenKrupp O 95 e9 0 = N of exit trash ® 1 hour fire—rated structural wall to enclosure its 110 forced air 213 AfvIEE 40 97 from floor to underside of l hour 1 hr from furnace �I a elevator [V fire--rated floor/ceiling assembly above o inside except 9 ❑ 11 ila 8 1 3 2 22 214 1 a9 NFWA8See Detail B/Al6 as indicated Pol w/b w 0 mechanical shaft o non—rated nonbearing = O w/o 1 F6ur=r5t" F 101 Fire Barrier Interior partition wall crosshatch � B O soli wall Indicates one bedroom Type B one bedroom Type B 1 103 see D/A16 A Indic a#es ICC TBL 601 I 105 See Detail C A16 a Vertical � corner apartment interior apartment / 1 Exit Enclosure see C/A13 115 lag see A/A13 sim ane bedroom Type B 96 0 one bedroom Type B Vertcal Exit 2 hour rated 117 111 ❑ 4x4 interior apartment 9a 92 comer apartment Encl sure I I��ll 1 hour fire—rated N = A} 242 244 Q 1 hour rated N Fire Barrier Fire Barrier & Shaft Enclosure see A/A13 sim see C/A13 sim P Date: ICC 706.5 at 707.5 Continuous from 8ea E/A16 a i 4x4 4x6 Fire Barrier (4 stories) floor to underside of floor above � � _ 248 250 �q see D/A16 �� 4x6 10� � aiiisna 4x4 106 See Detail D/A16 G A A A A two bedroom Type G � B � � C� O O � � �t~�sea 02/01/10 �■ 2 hour fire—rated corner apartment Fire Barrier & Shaft Enclosure H see D/A13 8H ICC 706.5 & 707.5 Continuous from A A floor to underside of floor above 246 @ o See Detail E/A16 /1 4x4 N J �i Sheet: 2 hour fire—rated Fire Wall 0 Qq Separating Buildings 8J�" 15' 0 0 Note: ICC 705.5 to noncombustible siding r r " e ■ r " " , • 1 " r r ■ r a ■ ■ " r • ■ r • u ■ i ■ ■ ■ ■ Coordinate Size. Type. �� ICC 705.6.1 from floor to underside 8—9 66 43 5 —9 7 3 5—9 431� 8—9 5—0 8—9 7—8 5—9 4—9 5—9 43� 5—0 8 —9 43� 5—9 7 3 5—9 43J�Z 66� 8—9 g)c" Yp of 1 hour fire—rated roof assembly poff�" 00 " and Location of a ■ . ■ e r ■ r CV2 ■ ■ 15 . r r r 1 ■ ire Extinguishers See Detail F/A1 fi 11 —6}� 15 —0 13 —0 13—0 15—0 37 —0 15 —D 13—0 13 —D 15—Q 10—0 g ['� Ir with Local Fire Chief CCoodinate with Shear Wall Types S e c o n d I I o or ,P­ Q n 11 12 13 14 EEnt once Security System See Structural Drawings B C /0 D rE IF by Owner under separate contr Contractor to coordlnQte work. -x A8 A8 A8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 6 15'-0' 13'-D' 13'-0- 15'-0" 15'-0" 10'-0" 12'-0" 15'_0" 13'-0" 13'-0" 15'-0" 8'-9' 66�' 43V W-9' 8 " 5'-9" 43 8'-9" 81 4a 8'-9" 539je" 5,-9" 1 " 5'-9" 8' 7)k" 8'-9" 43 5'-9" 71-3' 5'-9" 436' 66X" 8'-9' " " Lo r�5J J- " 8lz 15 I Exterior Wall (fire s pa ation distance > 5')— L.,1'/P�f 15 � » Q [A ® QA 1 hour rated from nsi a only per IB 704 = prescriptive detail Table 20.1(2) Item 1 -1.3 a fireplace flue guard rail @ 4x4 1 hour rated Fire Barrier o Elastomeric QA one bedroom Type B one bedroom Type B two bedroom Type B one bedroom Type B one bedroom Type B a �yL.i uid Fluorin yP 127 133 yP yP t46 152 yP q g comer apartment interior apartment interior apartment interior apartment corner apartment 6'-6" 10'-0' see C A13 sim 125 131 see A A13 see B A13 139 / 144 15D P extent of Lo / / / see A A13 sim see C/A13 sim rated wall 341 343 345 4x4 137 149 347 349 1pD20.B1.4 60" diameter Clock Face — — National time & signal HMR 360 Illuminated 4x4 entry -E� Through-Wall Mounted Round Clock WA WA w/b ■IV below a extent of 1 1 14B 1 : style AR markers w/ M01 hands ca Balc ny rated wall f2s 134 4x4 147 183 25, I install per mfr (typ of 3) 1 186 sf per IBC U = 31 1020.1.4 12$ 132 140 136 Note: 1 2 � 1 145 131 33" ext�rior all � � provide stairway " N O 124 13D 0 0 136 0 143 14s 0 1 hYr� to inside =� 1 2 floor number signs 12-0 07 O 0 WA 0 0 � ex pt a Indicated per IBC 1020.1.E �J C> P I �• " rescue 4x6 Corridor Walls 6x6 4x6 Wails Separating 6x6 4x6 4x6 elevator shaft 6x6 4x6 6x6 4x6 rescue " 35 " " 6'° attic ventilation 22 x36 = C D \ ❑ 2 hour 1 hour rated o P g 121 D C = i 4 60 35�`4 2 hour rated A o rated J Dwelling Units corridor = 1 hour rated o �dl� A 6too 5 diameter louvered I �I stair ceiling ® !I Fire Partitions I I I) 1 hourr rated I 367 sf oo II Fire Barrier II I I I ® stair to .� access door o 9 vent w/ bug screen 0 C D v 120 Fire Partitions 311 315 v D C ,t w/ ladder N 30D O terminate at r--� E E E 4x6 6x6 4x6 6x6 4xS 6 rated ceiling Sxfi 4x6 fixfi 4x6 0 ,CI1 x6 122 see E/A8 L_ 0 ZY 1 0 E oa metal O = °� 10 � r7 7sf O 1$D 174 o O 161 155 �' N unheated flashing exterior wall OL O struct O O ® znr (E of exit floor trash yssenKrupp N R attic = below = = beam forced air � AMEE 40 p 122 sf GI �I w 400 � endasure 36' 152 176 313 II 183 157 to i4 1 1 hr from furnace elevator e L2 hour 0 inside except 1 184 178 1 9 312 123 314 165 -WV] t5g V = = rated as Indicated ■fib VA 166 v0A � 1 stair ►� � FF K ceiling _ " Vertical E _ — p 167 r� o o '5 00 co 60 Exit Enclosure 37 " 37)J' B one bedroom Type B one bedroom Type B �A\ soli wall indicates o (n a ol 5-9 yp yp 1 one bedroom Type B one bedroom Type B 35Y4" 35'Y47 2 hour rated Vertical co 171 16s 1 cal it Enclosure = corner apartment interior apartment interior apartment corner apartment = Fire Barrier - o Exit Enclosure 1s1 175 182 156 1 h ur r teal o 12 -0 1 2 hour rated see C/A13 183 1T7 � see A/A13 sim 4x4 see A/A13 sim see C/A13 sim Fire Barr r I (4 stories) N = 342 344 348 164 158 350 / N Fire Barrier � a, 4x4 4x6 see D A16 r (4 stories) . Maintenance Fourth Floor � 168 Attic Fra,I'71 �n Q Go two q� �q � � � 4x6 4x4 172 1010 Go two bedroom Type B � corner apartment see D/A 17D 0 0 _ V `^J 13 H 0 346 0 ;n 4x4 �. N Q 1 5" O 4 O ) (/('O�'�'�j O 2 �" a "� V p�M 8'-9" 66)' 4W 5'-9' 7' 3' 5'-9" " 8'-9' 5'-0" 8'-9" 66)" 5'-9" E 5'-9" 43X" 5.-0" 1, 8'-9' 431 'L 5'-9" 7'-3" 5'-9" 43 fish' 8'_9" 11'-632," 15'-0' 13'-0' 13'-0" 15'-D" 15'-0' 2�" 12'-0" 15'-0" 15" 26'-0" 15'-0" 10'-0" 36' Ctocktower Floor Plan B C Third Floor Plan D F 1/ �=1r_Dr A1/8r=1r-Dr T 2 T 4 2x6 brg wall T T 7 8 T 2x4 brg wall 10 11 12 13 14 �l see A/A16 � � see B/A16Beam Schedule � cc3 2x4 brg wall 2x4 brg wail 2x6 brg wall 2x4 brg wall 2x6 brg wall "J No. QtY Nominal Sze Dressed Size Grade v see B/A76 see B/A16 see A/A16 see B/A16 see A/A16 A 64 5 i 2 x 7 1 4 DFL 0=`,r° ® B = c in B 3 1 2 x 9 1 2 same 2Q E PSL J 0 C 5 1 4 x 9 1 2 same 20 E PSL D 48 3 1 2 x 7 1 4 DFL M 0 •- hatch indicates 1 hr fire rated E 3 1 4 x 11 7 some 2Q E PSL joist cavity for fireplace flue F 5 1 4 x 11 7 same 2.0 E PSL sim- „ G 5 1 4 x 9 1 2 same 2.Q E PSL 2 layers 5 8 type X GWB H 1 6 3 4 x 13.5 same 1.8 E DF F GW see C/A3 El Nato: all r 9 ld 1) provide (2) layers 5/8" type X GWB wrap all beams 2) no wrap required at door and window heads 3) provide posts or gang studs as indicated with =a so :o =o =o �= o continuous blocking providing full bearing between floors co co to 4) provide simpson CS16 strap each end where any ® ® �nl beams are Installed without a continuous top plate .► °1 4 a: Z 1 T 1 T2. a, as m 912'-0" 12'-0" '� '�' 'g' LO shear framing °o 0 °0 00 00 for wall above ¢ ¢ Q_ - - E — — — o c cc) 0 0 r r r— r 11 j" TJI 110 floor joists ® 24" : 11 r TJI 110 4x6 oc0 o floor joists 0 16 oc = x 22"x36" 04 N L.. ® r r yr 2 hr fire rated access door Date: w/ ladder DF - No �C — — — — _<D 01/15/10 continuous wall revised 02/01/1� Maintenance Fourth Floor 2x6 LSL studs O 16'oc Attic Fr m i n q see Floor Plans for extent of rated wall see E A16 for detail 3/4" APA rated T&G subflr-finflr. glue and nail w/ 8d common nails 13 ° 0 6'oc diaphragm boundaries. 6"oc panel edges & 12'oc field VSheet. lay-out as indicated per IBC case 1 & 3 (unblocked diaphragm) except as directed by joist mfr 2x4 brg wall (typical at all wood floors) see B/A16 A5 locktower Framing Third Floor Framing Plan 2'-11" 3" 3' UJ "= metal lap above dark bronze flnloh t or point blast I p v II al e p rx} (12) 6' diameter vents drip flash drip flash metal gutter metal gutter 000 from kitchen hoods ll��✓✓ii rake rake by roof mfr 2 12 2/12 m roof mfr 000 Pon draft at drip flash � �- aiian over = limn below metal gutter metal gutter rake metal gutter metal gutter PWO sheathing w/ w/ flashing w/ flashing drip edge drip edge w/ flashing w/ flashing buld��O over g Paper over 2x4 homing ridge in app oximate dimensions indicated shingle over _ _ _ 000 mechanical contractor p fide vent 6 12 shingle over to coordinate metal cap drip flash g / ridge vent verify manufacturer's standard rake C/12 6/12 12 metal cap slzes coordinate to 6/12 6/12 adjust dimensions + 2" in each direction metal Gutter �' w flashing I fireplace fireplace pprovide screw as previously / g k flues valleyflues 1/jR I metal glitter directed by engineer 6 -6 valley valley valley valley w/ flashing chimney w/ valley chimney w/ 2" relief air to saddle shingle over saddle to room 9 ridge vent metal nP -- Fiberglass-Reinforced shingles dark bronze finish or paint black � � "' Slope I hlQTE: �r class A, high definition, laminated fireplace flue VTR #� sheet metal cap by rV p Coordinate the location of all roof vents rn w/ 3o year min. warranty fire rated shaft I drip mechanical subcontractor N to underside of U 9 I with the Architect to avoid locations on (typical roof) roof sheathing I I edge south facing roof suited for the - 1x4 over 1x8 trim Ui uture installation of solar panels. 1x4 comer do base trkn paint white 82-0.: W-0" (12) kitchen exhaust S-� o Hardie Panel siding \ kitchen exhaust kitchen exhaust kitchen exhaust M point to match 3rd floor A shingle over ridge vent corridor relief air I � chimney chimney chimney chimney metal Bub fashIng Indic flashing not Indicated coordinate flashing w/ roofing contractor I 1 N NOTE: I o0 combine plumbing vents a � with unit occrass the hall I I ",T WE and vent through the north roof o Install on ridge at grrdllne 6 edge 16/12 6 12� g mechanical(12 kltche:r ante) / I room below I I r) V CO (t corridor iidlef Air duct) ` valley dri o ed ChimneyDetail fnial � L6 .� CID C 1/$'=1'-0' Ct ICQI of 1) gutter — intake air o YP ashing chimney a rA � ashing I valley valley valley valley valley w/tfllas gutter ttr z'-11• or wall shingle over fireplace fireplace ing 6/12 fi/12 ridge vent 6 12 6 12 3• 2,_5. 3' � � flues VTR flues VTR � / / metal cap above drip flash — chimney w/ chimney w/ ar r-1cr dark bronze finish pL —shingle over saddle saddle shingle over or point black rake ridg vent 6/12 6/12 — ridge vent ---- PWD sheathing w/ bulding paper 400 ' over 2x4 framing ' I (3, 4, or 6) 6' diameter writs metal utter —W— metal metal metal ]I horn kitchen Hoods 9 gutter 1 i;, QOO w/ flashing gutter gutter w/ flashing N 000 I approximate dimensions indicated drip flash downspout I drip flash ., mechanical contractor p p to coordinate metal cap rake rake verify manufactures standard to storm metal cap sizes coordinate to drain adjust dimensions + 2' In each direction metal cap provide screen as previously dark bronze finish drip flash directed by engineer or point black rake sheet metal cap by 10 11 12 13 14 mechanical subcontractor C D E F A 1 x4 over 1 x8 trim 1x4 corner & base trim o paint white Plan Hardie Pane! hSiding 3rRoof Note: palret to match 3rd floor See Mechanical for Roof Penetrations Ametal sub fnshing 1/ 8,=1'-0� flashing not Indicated ll..� coordinate flashing w/ roofing contractor ct Iota. resell Install on ridge B' +/— west of gridl[ne 2 12 (B kitchen vents) 16 V ] Chimney Install on ridge west side of gridline g l Detail In kitchen vents) Install on ridge B' +/-- east of gridline 13 r/1 D (3 kitchen vents) / V1 1/8'=1'-0' (typical of 3) m t� top r� sill (12) kitchen exhaust kitchen exhaust kitchen exhaust kitchen exhaust and y ( / ) corridor relief air y ( / ) y ( / ) chimney see D A19 chimney (see C/A19) chimney see D A19 chimney see D A19 2'-11" i i l a r 3' 2'-5" 3' metal cap above11111 Ill Ill 111111111111111 Ill Ill Ill 111111111 Ill III [ I Ill ill V./ or pai2L dark nt blackze intake intake air o{ chimney ne) 12 �-i PWQ sheathing w/ buldinq paper � A19 over 2x4 framing u 20'x24" intake air or f� 20"x24" relief air to 12 1 2 to roam 312 . 6 6 in a N I aapprroximate dimensions indicated mechanical contractor i+7 N iV to coordinate metal cap verify manufacturer's standard metal cup sizes coordinate to adjust dimensions + 2' In each direction 41 "' —�-- metal cap dark bronze finish it I im d d '' . . . R d - d or paint black provide screen as previously P P Y directed by engineer ahem metal cap by mechanical subcontractor Date: i supplemental saddle or flashing 1x4 over 1x8 trim 1nsftuctlons coordinate with 1x4 comer N base trim roofing contractor paint white 02/10/10 I N Hardie Panel Siding paint to match 3rd floor FFE = 27.9D 1 x12 or brick HardiePla metal sub fashing flashing not Indicated YYQri� pOln t: Sheet: coordinate hashing to match existing facility water table siding w/ roofing contractor A19 ChimneyDetail InataIllntakeAEr10' awayhami�dtouatAir North Elevation E 1/88=1'-00 (typical of 1) =ram Q Q I 12" I 10'-0" k 6x6 block to foundation exterior wall of exit enclosure S S 9 11 endwall TF hanger 1 hr from inside at 4th floor g except as indicated framing 6x6 block to foundation a A 4 Lr�5e 11 viewing I N I bearing wall to foundation tg 1Btg SS viewing Unheated attic I headroom > 3' 82 sf net ° G 5 S. Ir O 11 7/8° joists CAD 16"ac DN ❑ access required o w/ TF hanger ea end _ 400 0 r windo S (D relocate exg stair B cv seat ❑ r4 stair not ( 11 7/8" LSL ledger B to 4th fir 22 x30 min. indicated ( A� reduce widths 1 hour rated A9 w/ 5/8 lag screw co DN R to rim 0 8"oc (stagger) to 36" self—closing 4 S i attic access Cl windoi iU N seat r 4th f toor Framing 4th f loor Stair Plan R s it E 1/4'=1'-0' 1/4"`=1'-0' i O 03 Co F E D C 8'-6" 10'-6" V] d oa ON kn Section revises A / A8 D 12 0 1/S8=1'-0' s 00 r cfl a � o a� r _ belt band provide (6) additional I CO attic see C/A10 window type E 0 i Locate exg tempered glass windows at 4th floor landing window framing c� provide double r (see elevations) king studs each side of trimmer A uninstalled trusses from double top plate vented lower bearing to 8'-1 " aff to sole plate below dbl o plate ( ) type 12 overhang window sill p flashin delete 2 window t e C this rake only - =� 6x w/ (2) S16 c° o str r ven tad 12 Per IBC 1020.1.4 ligh well 5.4 F 2 hour fire rated wall alig shear blk'g may be required due to 00 .� r clock tower window E N 6x w/ (2) S16 °�0 12 consult bulding official 6x s each nd s 5.4 prior to installation io of cement siding o vented to p to p tg ao tg I E shear blk g glass ss io 0 46.40 '� 4 `q D �17, 2x8 highest floor level C � 3 clg joist of public osccess r� W ° co W ` -- hemlock. handrail 7"x11�" PSL Sx8 PT � J--� 00 fire @ blkg w/ eas d e ges Balcony post 1 36 ab(p a tread o Q � Guard Rail _ i 2x h e ba u st 0 I see C A9 k - II 1 v 4" maxEl u clear t i i o i between' . . 1 f p r k r a= d. 2x6 spacer �--I er i c° along wall u l l I n f@ Q� stringer Co ,� , post/beam/post �- 't fire � 4 m ewe st N 7 x9 _ �••.� blk with x4 c V- conneectio s cur to bear ith z PSL by engineer n+ cement siding3 4 hru I s 0 1 secure to 1 r I rim r joist w/ Sx8 PT N U Co to uiders-de of I L 5/8 bolts Post c� building roo-1— �6 -CO co staggered discuss ! 0 12"oc detail on �j had room am mum thursday 1 03 80 above o N 04 ,: 0 tread nose r `Q I fire 8' 11 Date: UL Design No. U302 bl1�g brick to h supplemental GA File No. WP 8410 ,� o below grade instructions at brick veneer w/ 1 � 02/26/10 ' C888 wed PWD shth in lieu of non—rated c° `—�� 1" bev ed osi w co elevation of GeoGrid gypsum shth �r ao vlsua contra t 0 lowest level of Fire Department Vehicle Access CM U N Sheet: 10'-6" 20'-6" 11'-6�" PT 2x6 kicker 48"x48" ftg r .._ from 2x12 (4}#5 ea way 2 hour fire rated wall 2 hour fire rated wall between building and exit stair 2 hour fire rated wall 4'-8 ,4" 6'-5" carriage a way y4' 14 4„ �--00 A20 per IBC 1020.1.4 per IBC 1020.1.4 landing 7 treads eq. spaced 0 11"each @ 12"oc max. (contractor to verify) conc East Elevation North Elevation Stair Section revises B / A9 plinth • 1_ I . ._ o . ._ 1I4 _—i � C 1/4 _—1 0 1/4 1 D .tom a) 13 14 10'-0" clock face w/ 4X" iW from 2xl2 cedar trim 8,-g„ 1 hr rated wall flash top to underside of 1 hr rated r� o entry ceiling raise framed roof 12 PT 8x8 q C LSL ledger w/ 5/8" lags staggered at 8"oc belt band in line w/ floor framing infill porch �" O� IL resident 2 1//16 x 11 7/8 PSL `O w/ mitered corner at third floor sun roam w/ connector .h 96 sF Incidental use . for sun room D C a "' �� floor joists 16"oc : . » a / TF i'langer each end • �"'� Vill III III Hill 4�" rescue III III IL U 5•-2ITI „ extent of rated wall floor joists 16"oc iH per IBC 1020.1.4 w/ ITT TF hanger ea end stair at third floor provide 3/4" PWD web TIFTI �15 stiffener at Ledger ^ provide SD8 x 1.25 a to siffener and leger • r-� 00 O each side of joist cc LSL ledger w/ 5/8" lags staggered at 8"oc zn ay o0 Nail or screw PWD subflr lJ _ to rim and ledger ® 4"ocj cn Note• C� pq o � THIRD FLOOR PLAN 1 hour rated ceiling (2) layers 5/8" type X 0C WEST ELEVATION crosshatch indicates SOUTH ELEVATION 11x6sum T&Gsoffit cedarboard finish soil separation see detail D/A3 Mote: Provide R-30 min floor insulation work with architect to coordinate venting with fire rating T West Elevation South Elevation Third FloorMan Third Floor Framing C1/8'=10-08 L 1/80=1'-0' " • • B 1/8"=1'-0" bA Ct a3 ci I� Date: supplemental instructions 02/10/10 Sheet: A21 MECHANICAL UNITS MIN. EXT. COOLING HEATING ELECTRICAL THERMOSTAT & CONTROLS NOTES EQUIP MANUFACTURER & MODEL LOCATION SUPPLY O.A. S.P. CAPACITY CAPACITY NO. CFM AIR (IN. (BTU/HR.) (BTU/HR.) CFM W.G.) SEQUENCE OF OPERATIONS, VENTILATION AIR CONTROL FC112 FAN COIL, FIRST CO. RM-112 1070 150 0.3 — 47.000 0 120V/1HONEYWELL. VISIONPRO VERIFY BOILER SCHEDULE APPLIES TO FC112. FC212, FC312 MODEL 36XHBXB—HW 4 GPM & ECONOMIZER CONTROL MODULE: HONEYWELL MODEL SPECIFICATIONS WITH SUPPLIER. SET UP ELECTRICAL AIR HANDLER OFF: 160F W721A101. ACTUATOR: BELIMO MODEL BL—LF24—SR, DCA WITH 1DO% OSA ECONOMIZER FEATURE. MARK SERVICE INPUT OUTPUT EFFIC. VET MANUFACTURER/MODEL DESCRIPTION IF FOR ANY REASON, ANY AIR HANDLER IS SHUT OFF, THE OUTSIDE AIR (OSA) 2-10VDC, 35# SPRING SET. TEMP SENSORS: DRY BULB, PROVIDE LINE SETS, PLENUM, AND MBH MBH SIZE VOLT DAMPERS AND RELIEF AIR DAMPERS SHALL BE CLOSED. RETURN AIR HONEYWELL C7046A1004, DISCHARGE SENSOR, CONDUIT TO ADD AC AT LATER DATE RADIANT HOT 300 282 94X 4"0 120/1 MOD CON 300 HEAT TRANSFER PRODUCTS MODCON-300 HIGH EFFICIENCY CONDENSING GAS FIRED DAMPERS (RA) SHALL BE FULLY OPEN. SELECTED BY CONTRACTOR. DAMPERS FOR ECONOMIZERS, B-1 WATER BOILER. 94% PEAK EFFICIENCY. ASME RATED, 150 PSI WORKING PRESSURE, DIGITAL DISPLAY WITH LED INDICATORS, FULLY MODULATING BURNER WITH 5:1 TURNDOWN RATIO, OCCUPIED HEATING MODE: LOW NOx OPERATION, STAINLESS STEEL HEAT EXCHANGER, HIGH & LOW GAS PRESSURE OSA DAMPERS SHALL OPEN TO A MINIMUM SET POINT. RA DAMPERS SHALL FC212 FAN COIL, FIRST CO. RM-212 1070 150 0.3 — 47,000 ® 120V/1 SAME A5 FC112 SET UP WITH 100% OSA ECONOMIZER SWITCHES, UL/CSD--1 COMPLIANT, 120V/60 HZ/1 BE SET TO RETURN THE SPECIFIED AMOUNT OF RETURN AIR. RELIEF MOD'S PHASE SHALL BE SET" FULLY CLOSED. MODEL 36XHBXB—HW 4 GPM & FEATURE. PROVIDE LINE SETS, PLENUM, 16OF AND CONDUIT TO ADD AC AT LATER DATE PROVIDE WITH MANUAL RESET HIGH LIMIT & WELL, FLOW SWITCH KIT, AND CONDENSATE DURING OCCUPIED MODE, THE FAN WILL OPERATE CONTINUOUSLY AND THE NEUTRALIZER. HOT WATER VALVE FOR THE HEATING COIL FOR EACH UNIT WILL OPEN AND FC312 FAN COIL, FIRST CO. RM-312 1070 150 0.3 — 47,000 0 120V/1 SAME AS FC112 SET UP WITH 100% OSA ECONOMIZER CLOSE AS NECESSARY TO PROVIDE SPACE HEAT. MODEL 36XHBXB—HW 4 GPM & FEATURE. PROVIDE LINE SETS, PLENUM, MODULATING BOILER WITH 5 TO 1 TURN DOWN, FAN ASSISTED SEALED COMBUSTION; 160F AND CONDUIT TO ADD AC AT LATER DATE CONDENSING HOT WATER BOILER SHALL BEAR ASME "H" STAMP AND BE RATED FOR THE PROPOSED HOT WATER SYSTEM DOES NOT HAVE ANY FREEZE PROTECTIVE WORKING PRESSURE OF 160 PSI. GLYCOL. THE CONTRACTOR SHALL ENSURE THAT THE AIR HANDLERS CANNOT OPEN BEYOND THE MINIMUM OUTSIDE AIR SETTINGS DURING HEATING MODE SO FC124 FAN COIL, FIRST CO. RM-124 780 100 0.3 — 39,200 0 120V/1 SAME AS FC112 SET UP WITH 100% OSA ECONOMIZER THAT THE COIL CAN NEVER FREEZE MODEL 30XHBXB—HW 4 GPM & FEATURE. PROVIDE LINE SETS AND ON BOARD BOILER CONTROL SHALL INCLUDE LEAD/LAG FUNCTION, OUTDOOR RESET, AND 16OF PLENUM TO ADD AC AT LATER DATE PILOT DUTY START CONTACTS FOR (BOILER PUMPS. SUMMER OPERATIONS (OSA TEMPERATURE ABOVE 40'F) FAC121 2.5 TON FAN/AC—COIL. RM-120 1000 1000 — 30,OGO _ 208-230V HONEYWELL VISIONPRO 8000, SELECTION TWO STAGE THERMOSTAT. STAGE 1, FAN BOILERS AND BOILER PUMPS SHALL HAVE SEPARATE POWER STRIKES. / ECONOMIZER COOLING: BLOWER — GOODMAN MBR1200AA-1 RM-121 1PH AND PROGRAMMING BY CONTRACTOR ONLY, STAGE TWO, AG. MAINTAIN LESS PROVIDE CLEARANCES TO COMBUSTIBLES AS REQUIRED BY APPLICABLE CODES AND WHEN ROOM TEMPERATURE IS ABOVE THE OSA TEMPERATURE, OSA DAMPERS AC — GOODMAN GSX130301 25 AMPS THAN 79'F IN ROOM. IF LESS THAN SHALL MODULATE OPEN AND THE RA DAMPERS SHALL MODULATE TO THE COIL — GOODMAN CAPF3030D6 MAX. 77F, FAN TO TURN OFF. MANUFACTURER'S RECOMMENDATION. CLOSED POSITION, MOD'S IN RELIEF VENTS SHALL BE FULLY OPEN, FOR 10OX EXP. VALVE KIT — GOODMAN TX3N4 AVAILABLE THROUGH MATT OF JOHNSTONE COMBUSTION AIR INTAKE MATERIAL: PVC OR CPVC. OSA OPERATION. FANS SHALL OPERATE AT FULL CAPACITY. PAD — GOODMAN UC3030-3 SUPPLY — BOTHELL. BOILER GAS PRESSURE: 3.5" W.C. MIN, 14" W.C. MAX. WHEN OSA TEMPERATURE IS ABOVE INSIDE AIR TEMPERATURE, MOD's WILL FC219 FAN COIL, FIRST CO. ROOM 267 100 0.3 — 47,000 0 120V/1 SAME AS FC112 SET UP WITH 10OX OSA ECONOMIZER MODULATE TO THE HEATING MODE POSITION DESCRIBED ABOVE. MODEL 36XHBXB—HW 118 4 GPM & FEATURE. PROVIDE LINE SETS, PLENUM, 16OF AND CONDUIT TO ADD AC AT LATER DATE RADIANT HOT 500 470 94% 4"� 120/1 MOD CON 500 HEAT TRANSFER PRODUCTS MODCON-500 HIGH EFFICIENCY CONDENSING GAS FIRED SEQUENCE_OF OPERATIONS, VENTILATION AIR CONTROL RBH RADIANT BASEBOARD TYP. _ — — -- SEE NOTES — " DANFOSS RA 2000 450BTU/LF 0 1 GPM AND 160F, B-2 WATER BOILER. 94% PEAK EFFICIENCY. ASME RATED, 150 PSI WORKING PRESSURE, DIGITAL APPLIES TO FC219 HEATER, SLANT/FIN 480 BTY/LF 0 4 GPM AND 160F. SEE DISPLAY WITH LED INDICATORS, FULLY MODULATING BURNER WITH 5:1 TURNDOWN RATIO, FINE/LINE 30 PLANS FOR LENGTH OF EACH UNIT. LOW NOx OPERATION, STAINLESS STEEL HEAT EXCHANGER. HIGH & LOW GAS PRESSURE AIR HANDLER OFF: CONTRACTOR TO SELECT STYLE OF VALVE. IF FOR ANY REASON, ANY AIR HANDLER IS SHUT OFF, THE OUTSIDE AIR (OSA) REMOTE MOUNT TSTAT NEXT TO DOOR. SWITCHES, UL/CSD- 1 COMPLIANT, 120V/60 HZ/1 DAMPER SHALL BE CLOSED. RETURN AIR DAMPER (RA) SHALL BE FULLY PHASE. OPEN. FP1 EXTRODINAIR SPACE SEE — — — _ 120V/1 REMOTE CONTROL 20.5 MBH INPUT, 15.7 MBH OUTPUT PROVIDE WITH MANUAL RESET HIGH LIMIT & WELL, FLOW SWITCH KIT, AND CONDENSATE SAVER GAS FIREPLACE, PLANS NEUTRALIZER. OCCUPIED HEATING MODE: MODEL FPX 564 OSA DAMPERS SHALL OPEN TO A MINIMUM SET POINT. RA DAMPERS SHALL MODULATING BOILER WITH 5 TO 1 TURN DOWN. FAN ASSISTED SEALED COMBUSTION; BE SET TO RETURN THE SPECIFIED AMOUNT OF RETURN AIR. FP2 HEAT & GLO, SEE ROOM — — — — _ 120V/1 REMOTE CONTROL 26-37 MBH INPUT, VARIABLE. CONDENSING HOT WATER BOILER SHALL BEAR ASME "H" STAMP AND BE RATED FOR THROUGH GAS FIREPLACE, 216/217 WORKING PRESSURE OF 160 PSI. DURING OCCUPIED MODE, THE FAN WILL OPERATE CONTINUOUSLY AND THE MODEL ST-36 HOT WATER VALVE FOR THE HEATING COIL FOR EACH UNIT WILL OPEN AND ON BOARD BOILER CONTROL SHALL INCLUDE LEAD/LAG FUNCTION, OUTDOOR RESET, AND CLOSE AS NECESSARY TO PROVIDE SPACE HEAT. RTU1 5—TON ROOFTOP GAS DINING 1950 300 — 59,500 90,000 208V/1 HONEYWELL VISIONPRO 8000, SELECTION AND PROVIDE COMPLETE SYSTEM WITH PILOT DUTY START CONTACTS FOR BOILER PUMPS. PACK WITH 100% AREA BTUH PROGRAMMING BY CONTRACTOR MOTORIZED DAMPERS FOR 0-100% THE PROPOSED HOT WATER SYSTEM DOES NOT HAVE ANY FREEZE PROTECTIVE ECONOMIZER. INPUT ECONOMIZER AND BAROMETRIC RELIEF. BOILERS AND BOILER PUMPS SHALL HAVE SEPARATE POWER STRIKES. GLYCOL. THE CONTRACTOR SHALL ENSURE THAT THE MOTORIZED DAMPERS GOODMAN MODEL AVAILABLE THROUGH MATT" OF JOHNSTONE CANNOT OPEN BEYOND THE MINIMUM OUTSIDE AIR SETTINGS DURING HEATING CPGO600901 DAJX SUPPLY — BOTHELL. PROVIDE CLEARANCES TO COMBUSTIBLES AS REQUIRED BY APPLICABLE CODES AND MODE SO THAT THE COIL CAN NEVER FREEZE. MANUFACTURER'S RECOMMENDATION. HP2 EXISTING HEAT PUMP. DINING SUMMER OPERATIONS (OSA TEMPERATURE ABOVE 40'F) AREA — — — — — RELOCATE HEAT PUMP. SEE SHEET M10. COMBUSTION AIR INTAKE MATERIAL: PVC OR CPVC. ECONOMIZER COOLING: WHEN ROOM TEMPERATURE IS ABOVE THE OSA TEMPERATURE, OSA DAMPERS BOILER GAS PRESSURE: 3.5" W.C. MIN, 14" W.C. MAX. SHALL MODULATE OPEN AND THE RA DAMPERS SHALL MODULATE TO THE CLOSED POSITION. FOR 100% OSA OPERATION. FANS SHALL OPERATE AT FULL MUA1 EXISTING MAKE UP AIR DINING — — — — _ — RELOCATE EXISTING. SEE M10. CAPACITY. IT IS UNDERSTOOD THIS ZONE WILL PRESSURIZE DURING UNIT. AREA DOMESTIC HOT 199 — — 6*0 120/1 PHOENIX MODEL PH199-119S HEAT TRANSFER PRODUCTS PHOENIX CONDENSING GAS FIRED WATER HEATER. 119 ECONOMIZER COOLING MODE. WH1 WATER GALLON FAN POWERED GAS FIRED WATER HEATER. 199MBH INPUT. 2" SCH. 40 PVC MUA2 EXISTING MAKE UP AIR DINING _ _ _ _ _ — RELOCATE EXISTING, SEE M10. AIR INTAKE, 3" SCH 40 PVC EXHAUST. 96.1% PEAK EFFICIENCY. WHEN OSA TEMPERATURE IS ABOVE INSIDE AIR TEMPERATURE, MOD'S WILL UNIT. AREA HEAT TRANSFER PRODUCTS PHOENIX CONDENSING GAS FIRED WATER HEATER. 119 MODULATE TO THE HEATING MODE POSITION DESCRIBED ABOVE. RAH314 GREENHECK GRAVITY ROOF WH2 DOMESTIC HOT 199 — — 6"s� 120/i PHOENIX MODEL PH199-1195 „ RELIEF VENTILATOR HOOD WATER GALLON FAN POWERED GAS FIRED WATER HEATER. 199MBH INPUT. 2 SCH. 40 PVC AIR INTAKE, 3- SCH 40 PVC EXHAUST. 96.1% PEAK EFFICIENCY. MODEL FGR. 30" X 36" SEQUENCE OF OPERATIONS. VENTILATION AIR CONTROL APPLIES TO FAC121 BOILER ROOM EQUIPMENT SCHEDULE AIR HANDLER OFF: MANUFACTURER/ IF FOR ANY REASON, ANY AIR HANDLER IS SHUT OFF, THE OUTSIDE FC125 FAN COIL, FIRST CO. RM-125 780 100 0.3 — 39,200 0 120V/1 SAME AS FC112 SET UP WITH 100% OSA ECONOMIZER MARK EQUIPMENT VOLT/PH MODEL REMARKS AIR (OSA) DAMPERS SHALL BE CLOSED. MODE,. 30XHBXB—HW 4 GPM & FEATURE. PROVIDE LINE SETS AND 16OF PLENUM TO ADD AC AT LATER DATE BOILER CIRC. 120V/1 PH ARMSTRONG E22 HP, 3300 RPM, INCLUDE COMPANION FLANGES OCCUPIED MODE: BP1 PUMP FAC121 SHALL BE SET UP FOR TWO STAGE COOLING. PRIMARY COOLING SHALL BE 100% OSA ONLY. IF THE ROOM TEMPERATURE RISES ABOVE 85F, AIR TERMINAL SCHEDULE BP2 BOILER CIRC. 120V/1 PH ARMSTRONG E24 HP, 3300 RPM, INCLUDE COMPANION FLANGES THE DX COOLING SHALL OPERATE AS NECESSARY TO KEEP THE ROOM PUMP TEMPERATURE AT OR BELOW 85'F. SYMBOL ITEM MFG MODEL SIZE CFM MATERIAL MOUNT FINISH " „ IF THE ROOM TEMPERATURE FALLS BELOW 72`F, THE FAN IN FAC121 SHALT_ 2—WAY SUPPLY DIFFUSER " " SEE HYDRONIC LOOP 248-23DV/3PH ARMSTRONG 2 HP, 1804 RPM, 85 GPM AT 33' OF HEAD, 2 DNA. INLET/OUTLET, 6.18 DNA. IMPELLER. SHUT OFF. SG1 W/OBD SHOEMAKER 902—D 10 X 10 ALUMINUM GWB CEILING SOFT WHITE HLP1 PUMP ARMSTRONG SERIES 4380. PROVIDE ON/OF SWITCH. ON CONTINUOUSLY DURING HEATING SEASON. PLANS SEQUENCE OF OPERATIONS FOR RTU1 SB2 4—WAY SUPPLY DIFFUSER SHOEMAKER MA 0 1D" X 10" SEE GALV. BLADES, GWB CEILING SOFT WHITE HWC1 DOMESTIC HOT WATER 115/1 ARMSTRONG E7B IN—LINE 12 GPM 0 23 FT. HEAD, 1/6 HP, 208 1 PH. PROVIDE WITH ( FOR ANY REASON, THE UNIT 1S SHUT OFF, THE OUTSIDE AIR W/OBD PLANS ALUMINUM FRAME CIRCULATOR PUMP PUMP FLANGE X THREAD AND THREAD X SOLDER ADAPTERS. (OSA) DAMPERS SHALL BE CLOSED. SG3 2—WAY SUPPLY DIFFUSER SHOEMAKER 902-0 24" X 4" SEE ALUMINUM MOUNT To SOFT WHITE OCCUPIED MODE: W/OgD PLANS EXPOSED DUCT BOILER _ ARMSTRONG 50 GPM FLOW AT A LOW Cv. IPT CONNECTION. RTU1 FAN SHALL OPERATE CONTINUOUSLY AND THE HEATER OR AIR BV-1 BALANCING VALVE CBV-2T CONDITIONER SHALL OPERATE AS NECESSARY TO HEAT OR COOL THE SPACE SG4 2—WAY FLOOR REGISTER SHOEMAKER AFP SERIES 8" X 14" SEE ALUMINUM FLOOR SATIN ANODIZED BOILER _ ARMSTRONG 30 GPM FLOW AT A LOW Cv, IPT CONNECTION. AS REQUIRED. PLANS BV-2 BALANCING VALVE CBV-2T NIGHTTIME MODE: SEE ARMSTRONG TANK VOLUME 22.0 GAL, ACCEPTANCE 14.9 GAL, MAX. OPERATING PRESS. 150 PSI, WEIGHT 8$ THE FAN SHALL OPERATE ONLY WHEN THE TEMPERATURE IN THE SPACE IS SG5 1—WAY DIFFUSER SHOEMAKER 950 8" X 14" PLANS ALUMINUM DUCT MOUNT SOFT WHITE ET1 EXPANSION TANK, _ OUTSIDE OF THE SET POINT. THE HEATER, ECONOMIZER, OR AIR CONDITIONER DOMESTIC HW MODEL AST-42 LB, 16 O, 1 CONNECTION. " " SEE DRIFTWOOD SHALL OPERATE AS NECESSARY TO CONDITION THE SPACE. SG6 1—WAY DIFFUSER SHOEMAKER 950 10 X 12 STEEL CARPET TAN TANK VOLUME 34 GAL, ACCEPTANCE 12.5 GAL, MAX. OPERATING PRESS. 150 PSI, WEIGHT 111 PLANS ET2 EXPANSION TANK, _ ARMSTRONG LB, 16"�, 1" CONNECTION. COOLING MODE, STAGE 1: „ " SEE H1TATING HW MODEL AX-60V THE ECONOMIZER SHALL MODULATE WHEN: SG7 2—WAY SIDEWALL DIFFUSER SHOEMAKER 950-0 B X 4 PLANS STEEL DUCT SOFT WHITE A. THE OUTSIDE AIR TEMPERATURE IS LESS THAN 667F (ADJUSTABLE) HV1 TEMPERING VALVE — HOLBY, 2-4" 120'F MIXING VALVE. HOL13Y VALVE AVAILABLE FROM MECHANICAL SALES, SEATTLE. NO B. THE FAN IS ON SUBSTITUTIONS ALLOWED WITHOUT ENGINEERS APPROVAL. " SEE COOLING MODE. STAGE 2: 5G8 1—WAY SIDEWALL DIFFUSER SHOEMAKER 950-0 12" X 6 PLANS STEEL DUCT SOFT WHITE 3WV THREE WAY VALVE BELIMO MODEL 3—WAY VALVE AND ACTUATOR. VALVE SIZED FOR 85 GPM AT 3.5 PSI DROP WITH A Cv OF 46. WHEN THE OUTSIDE AIR TEMPERATURE IS ABOVE 66'F (ADJUSTABLE) AND THE B349+ARB24—SR ACTUATOR CONTROLLED BY BMS. ZONE IS CALLING FOR COOLING, THE. THERMOSTAT SHALL INITIATE THE 2ND SG9 1—WAY SIDEWALL DIFFUSER SHOEMAKER 906 12" X 6" SEE ALUMINUM DUCT SOFT WHITE STAGE COOLING AND THE AIR CONDITIONER SHALL OPERATE AS NECESSARY. PLANS pDS1 AIR/DIRT NA546, CALX FL MODEL PLUMB DRAIN TO FLOOR DRAIN WITH 1"0 TYPE M COPPER DURING STAGE 2 COOLING, THE OUTSIDE AIR DAMPERS SHALL RETURN TO SEPARATOR NA546, FLG X FLG. THEIR MINIMUM OPEN POSITION. " " SEE TG1 1—WAY SIDEWALL DIFFUSER SHOEMAKER 905 10 X 6 ALUMINUM WALL SOFT WHITE BMS BOILER ATS SYSTEM WAS DESIGNED ASSUMING ALERTON COMPONENTS. CONTACT KEN DUNCAN AT PLANS MANAGEMENT 360-707-5800 OF ATS FOR QUOTE. ALTERNATIVE BMS CONTROLS MAY BE ALLOWED IF APPROVED RADIATORS:SLAWEIN SYSTEM BY THE ENGINEER. SEQUENCE RG1 RETURN GRILLE SHOEMAKER 908-0 14" X 14" PSEE LANS ALUMINUM GWB CEILING SOFT WHITE THE DANFOSS THERMOSTATIC CONTROL VALVE SHALL OPEN AND CLOSE AS DP DIFFERENTIAL _ ANTS VERfS FIELD SELECTABLI= DIFFERENTIAL PRESSURE TRANSDUCER. USE 4-20 mA OUTPUT, SPECIFIED NECESSARY TO HEAT THE SPACE. NO PROVISION FOR COOLING IS PROVIDED. RG2 RETURN GRILLE SHOEMAKER 1600 14" X 24" SEE STEEL PET DRIFTWOOD PRESSURE BY CONSTROLS CONTRACTOR. PLANS TAN TRANSDUCER _ _ _ RG3 RETURN GRILLE SHOEMAKER 600 14" X 14" SEE AL WALL SOFT WHITE SEQUENCE OF OPERATIONS BOILER PLANS THE TWIN BOILERS SHALL OPERATE IN A PRIMARY SECONDARY ARRANGEMENT RG4 RETURN GRILLE SHOEMAKER 600 16" X 16" SEE AL WALL SOFT WHITE FAN SCHEDULE WITH THE 300 MBH BOILER SET AS THE PRIMARY. PLANS FIRE AND SMOKE DAMPERS OL1 OUTSIDE AIR LOUVER SHOEMAKER 4500—IS 28"X24" SEE AL WALL DRIFTWOOD FAN I.D. CFM S.P. MAKE MODEL FAN TYPE LOCATION VOLTAGE PHASE HP CONTROL NOTES CONTROL NOTES PLANS TAN SYMBOL DESCRIPTION OL2 OUTSIDE AIR LOUVER SHOEMAKER 4500—IS 20"X20" SEE AL WALL DRIFTWOOD BF1 65 .25 BROAN QTRO80 FACE OF BATH 120 1 FRACTIONAL WALL TYPICAL OF EACH RESIDENT ROOM PLANS TAN SOFFIT CEILING SWITCH SMOKE DAMPER. RUSKIN, MODEL SDRS25. DRIFTWOOD UL 555S LEAKAGE CLASS 1 CLASSIFIED. OL3 OUTSIDE AIR LOUVER SHOEMAKER 4550—RS 10"X14" SEE AL WALL TAN LF1 50 .1 BROAN QTRO50F FACE OF LAUNDRY 120 1 FRACTIONAL_ WALL TYPICAL OF EACH RESIDENT ROOM MOUNT WITHIN 2' OF THE DIFFUSER. PLANS SOFFIT CEILING SWITCH DRIFTWOOD / FIRE DAMPER, OL4 OUTSIDE AIR LOUVER SHOEMAKER 4550—RS g"X10" SEE AL WALL RH1 175 — WHIRLPOOL WMH1162XVS RANGE KITCHEN 120 1 FRACTIONAL CONTROLLED BY CONSOLE, TYPICAL OF EACH RESIDENT ROOM RUSKIN, MODEL DIBD2. UL PLANS TAN MICROWAVE VARIABLE SPEED. 555 LISTED. DRIFTWOOD EF122 65 .25 BROAN QTRO80 CEILING BATH 120 1 FRACTIONAL WALL — OL5 OUTSIDE AIR LOUVER SHOEMAKER 4550—IS 24"X14" PLANS SEE AL WALL TAN MOUNT CEWNG SWITCH COMBINATION FIRE/SMOKE DAMPER, RUSKIN, WL7 WALL LOUVER FAMCO LH 6"o SEE PLASTIC PLASTIC WALL WHITE MODEL FSD36. UL 555 AND UL 555S CLASSIFIED. WL2 WALL LOUVER FAMGO UFH 4"O PLEAENS PLASTIC WALL WHITE DRAWN/DESIGNED BY: CAD FILE NUMBER: 1 1/10/10 BP MODIFIED MODEL OF 5G4, 1,ADDED FC1 SG7 APPROVED FOR CONSTRUCTION H. q r INDEPENDENT LIVING BP/CG VENTILATIONDIAGRAMS-09001 2 2 10 10 BP ADDED OL5, 5G8, SG9, TG 1, FC 125, RAH314 � t CHANDLERS SQUARE CHECKED BY: COUNTY: CG SKAGIT G Al f I R ■ �� �J� I I �RL I r�� AN A� ORTES ■■ A DATE: JOB NUMBER: IFC 01/15/10 09001 REVIEWING ENGINEER DATE �' q SCALE: �rST�g HORIZONTAL SEE PLANS JURISDICTION �`S�C�NAL1��Cs MECHANICAL SCHEDULES 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707-5858 '_ VERTICAL N/A �J M 1 O F 1 No. DATE INIT. REVISION . APPROVALS I)ate Signed �2r11 16 �, i HHWR FROM OTHER RADIANT BASEBOARD HEATERS ATTIC FP1 PLUMBING SCHEDULE SYMBOL ITEM DESCRIPTION W V CW HW P1 WATER CLOSET VITREOUS CHINA FLOOR MOUNTED, ELONGATED BOWL, SIPHON ACTION BOWL 1.6 GALLON 3" 2" 1I2" DRYER VENT (DV). TERMINATE METAL FLUSH. ADA APPROVED, 17-1/4" BOWL HEIGHT. AMERICAN STANDARD CADET 111. DUCT WITHIN 2' OF 3016.016 BOWL, 4021.016 TANK, ORDER WITH AM. STD. SOLID PLASTIC CLOSED FRONT DRYER EXHAUST. r � SEAT. 3RD FLOO__jR TYPICAL WL1 P2 LAVATORY 20" X 17" ADA APPROVED VITREOUS CHINA COUNTERTOP LAVATORY. AMERICAN STANDARD 1-1/2" 1-1/2" 1/2" 1/2" AQUALYN MODEL 0476.028 WITH 3 HOLES AND 4" CENTERS. FAUCET - SINGLE LEVER WITH RANGE HOOD (RH1) DRYER (D1) SEE ARCHITECTURAL PLANS AERATOR,AND p2 SPEED CONNECT DRAIN. AMERICAN STANDARD RELIANT 3, MODEL DISHWASHER (DW) �UNDRY FAN(LF1) FOR FIREPLACE VENT DETAIL. WASHER (W1) 3 FP1 P3 KITCHEN SINK 25" X 22" TWO COMPARTMENT KITCHEN SINK. 20 GAUGE SS, SELF RIMMING 4 HOLE 1-1/2' 1-1/2" 1/2 1/2" /� PUNCH WITH CUP STRAJNER. ELKAY DSE-12522. SINGLE LEVER COMBINATION FAUCET WITH SWING SPOUT AND AERATOR. AMERICAN STANDARD 1" COPPER FOR HEATING HOT WATER P5 � RELWVT+, MODEL 4205.000. PROVIDE LIQUID SOAP DISPENSER, AMERICAN STD. MODEL 4503.115. BATH FAN (BF1) . P 1 P2 P4 UTILITY SINK SWAN FN 1 FREE STANDING SERVICE SINK. PROVIDE WITH FLOOR HARDWARE, MODEL 1-1/2- 1-1/2" 1/2- 1/2- P4 L572 60. FAUCET: AMERICAN STANDARD LAUNDRY FAUCET WITH METAL HANDLES, MODEL 2ND FLOOR 3 2j" COPPER SUPPLY FOR HEATING VENT THROUGH HOT WATER ROOF (VTR) � No �43 ps SHOWER LASCO ACRYLIC SHOWER STALL, MODEL 4836—BF5 USE AMERICAN STANDARD R120 ROUGH 2" 1-1/2" 1/2" 1/2" i IN VALVE, WITH SINGLE HANDLE TRIM MODEL T675.500. WALL SUPPLY 8888.037, 24" VERTICAL SLIDE BAR MODEL 1660.225, HOSE MODEL 8888.035, SHOWER HEAD MODEL j" PEX F"R HEATING HOT WATER RETURN TYPICAL PLUMBING AND MECHANICAL CALLOUTS 1ssa.5oo. TYPICAL. PEX FOR HEATING HOT wA PLUMBING AND MECHANICAL CALLOUTS FOR ROOMS 103 AND 105 SCALE: A„ = 1° SCALE: " = 1' P6 ADA SHOWER LASCO ACRYLIC SHOWER STALL, MODEL 3636-BFS W/ADA OPTION. USE AMERICAN 2" 1-1/2" 1/2" 1/2" STANDARD R120 ROUGH IN VALVE, WITH SINGLE HANDLE TRIM MODEL T675.500. WALL SUPPLY 8888.037, 24" VERTICAL SLIDE BAR MODEL 1660.225, HOSE MODEL 8888.035, 7 SHOWER HEAD MODEL 1660.500. J" BALL VALVE FOR HEATING HOT WATER MANUAL SHUT OFF p7 UTILITY SINK ELKAY STAINLESS STEEL SINGLE BOWL SINK WITH SOAP DISPENSER, MODEL 1--1/2" 1-1/2" 1/2" 1/2" 22"X19"X71". FAUCET: AMERICAN STANDARD KITCHEN FAUCET WITH METAL LEVER HANDLE, NOTE: INSTALL J" BALL VALVE ON THIRD FLOOR MODEL 4175.500. LIQUID SOAP DISPENSER MODEL 4305.200.002. THE INLET AND OUTLET OF EACH BV � HOT WATER RETURN HEATER 1ST FLOOR FS1 FLOOR SINK CECO ENAMLED CAST IRON 12"X12"X6" FLOOR SINK. 2" 1-1/2" - - DOMESTIC HOT WATER CO CLEAN OUT CAST IRON CLEAN OUT, JR SMITH #4023-9. MOUNT FLUSH WITH GRADE. USE 6- SOR 35 4" - - - FOR DOWN PIPE TO SS. SECTION A—A HYDRONIC HEATER CONNECTION DETAIL HB1 HOSE BIBB FREEZELESS ANTI-SIPHON WALL FAUCET. WOODFORD MODEL 17 OR EQUAL. - _ 3/4" _ SCALE: ►' = 1 APPLIANCE SCHEDULE 2" SECOND FLOOR SYMBOL ITEM DESCRIPTION W V CW HW BV BV i" HOT WATER RETURN I I I I I j WI RESIDENTIAL WHIRLPOOL 3.4 CUBIC FOOT ENERGY STAR FRONT LOAD WASHER, MODEL WFW8300SW. 2" - 1/2" 1/2" DOMESTIC HOT WATER CLOTHES WASHER W2 COMMERCIAL MILNOR 60 LB. COMMERCIAL CLOTHES WASHER, MODEL 30022 VJ6. 3" - 3/4" 3/4" TYPICAL FIXTURE TAKE—OFFS CLOTHES WASHER 24" D1 RESIDENTIAL WHIRLPOOL SUPER CAPACITY 6.7 CUBIC FOOT ELECTRIC DRYER, MODEL WED8300SB. _ 4" - _ CLOTHES DRYER COLD WATER SHUT OFF VALVE FIRST FLOOR HOT WATER SHUT OFF VALVE -% " COLD WATER 1" 1" CLOTHES WASHER SHUT OFF NOT WATER — � D2 COMMERCIAL MILNOR 75 LB. COMMERCIAL CLOTHES DRYER, MODEL M758V. g" 1 j" WASTE DW DISHWASHER WHIRLPOOL ENERGY STAR DISHWASHER, MODEL DU85OSWPS. 1-1/2" 1-1/2" 1/2" 1/2" " HOT WATER " COLD WATER UNIT SHUT OFF VALVE --- �Q OUNIT SHUT OFF VALVE PIPING SYMBOLS -�— HOT WATER IN-� COLD WATER IN HOLBY VALVE I 1. EACH PLUMBING FIXTURE SHALL BE INDIVIDUALLY VENTED AND ALL PIPE INSULATION SCHEDULE SYMBOL DESCRIPTION OI--I� CONSTRUCTION NOTES = 2• PROVIDE FULL PORT BALL VALVE SHUT OFFS AND UNIIONS FOR EACH 120'F HWS PIPE MINIMUM INSULATION TEE VENTS ROUTED IN WALLS, FLOORS, AND CEILINGS TO MAIN VENT CW }[�" ON RISERS & MAINS iy� UNION 2- " T HOT WATER RETURN 140'F HW5 RISER FOR THAT LOCATION. SEE WASTE & VENT RISER DIAGRAMS. HW (1)RUNOUTS 2" AND GREATER CHECK VALVE LESS THAN 2" t �� GATE VALVE TYPICAL PLUMBING DETAIL UNDER LAVATORY LIVING UNIT PER DETAIL .5" 1" 1 ' � BALL VALVE SCALE: 1" = 1' 120'F HWR 3• SLOPE FOR EACH WASTE PIPE SHALL BE j" PER FOOT IF POSSIBLE. HHW - 1" " 1i" i-#N-t CONTROL BALANCING VALVE HWC1 ALL PIPES WITH LESS SLOPE SHALL BE APPROVED BY THE ENGINEER. HHWR - 1" 1i" � THERMOMETER ADA NOTES: OHIF--O 1) IN UNITS 103 AND 105 ONLY, CONCEAL ALL HOT AND COLD WATER PIPING IN WALLS. USE GATE VALVES IN LIEU OF BALL VALVES FOR UNIT SHUT OFFS. IXP05E HANDLE OF VALVE THROUGH WALL NOTE: (1) RUNOUTS TO INDMDUAL UNITS ;--�i DIRECTION FIRE CAULK U PENETRATION. SHALL NOT EXCEED 12 FT. IN LENGTH UNLESS 2) EXPOSED PIPES TO BE INSULLATED PER ADA REQUIREMENTS. 2" 2" APPROVED BY THE ENGINEER. ,�[ TEMPERATURE & PRESSURE RELIEF VALVE, 125 PSI, WATTS OR EQUAL Q�V AUTOMATIC AIR VENT, BELL I AND GOSSETT, MODEL EASE-JR OR EQUAL. INSTALL WITH A 12"X12"X1" GALVANIZED PAN UNDER VENT TO CATCH ANY DRIPS. E71 COMMERCIAL G- � LAUNDRY MACHINE r--►-� REDUCER 0 � O Q Ftaw SWITCH OHS OH 1HR EXTERIOR WALL . . . a THERMOSTAT FLOOR SINK FLOOR SINK TO DRAIN TO DRAIN RATED CAULK - 3M CP 25WB+ �—IO G G AND FD-150+ OR EQ. WATER HEATER PROCESS AND INSTRUMENTATION DIAGRAM P&ID) DUCT 4"0 FOR LAUNDRY NTS 2006 WASHINGTON STATE ENERGY CODE NOTES 6"0 FOR FAN EXHAUST 1. AS BUILT DRAWINGS AND OPERATIONS MANUALS WILL BE PROVIDED TO BUILDING OWNER IN ACCORDANCE WITH WSEC SECTIONS 1416.1 AND 1416.2. 2. PIPE INSULATION: PER TABLE 5-12 OF THE WASHINGTON STATE ENERGY CODE (WSEC). TYPICAL DUCT/EXHAUST VENT DETAIL NTS E DRAWN/DESIGNED BY: CAD FILE NUMBER: 1 1/18/1 O BP P7 ADDED TO PLUMBING SCHEDULE APPROVED FOR CONSTRUCTION '; ( Cj H AN D LE R'S S O U A R E INDEPENDENT LIVING BP/CG VENTILATIONDIAGRAMS-09001 wA CHFCKED BY: COUNTY: t CG SKAGIT DATE: JOB NUMBER: R RISON ENGINEERING E SI IFC (}1/15/10 REVIEWING ENGINEER DATE SCALE: 09001 �. AN ACORTES, WA JURISDICTION HORIZONTAL SEE PLANS 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707-5858 SPECIFICATIONS AND SCHEDULES VERTICAL N/A M 2 O F� 10 No. DATE INIT. REVISION APPROVALS '®ate tgned � 1l ft� 4., 4„ 4„ 4„ 4" r----� i---- i r__—_� r---- ROOF I I 1 I i 1 I I 2 2" 3„ i 3„ 3„ 2' 2„ I I -- TO RISER 10 r---- TO RISER 14 r---- TO RISER 15 -I---- �----- r --- TO RISER 4 L----� i - TO RISER 3 ----� TO RISER 4 r---- TO RISER 9 r------�yTO RISER 10 -----�---- �----T---� --- I 1 TO RISER 3 4---- ---�_--- - 1 ! I 3"1 I 1 I3„ 13" 1 1 I I2. I I I2" 1 2" 13' 1 I I I I ATTIC 1 ! I ! F--- ----� F---� I r----j 1 I I I I I I I 1 { I 1 1 I I LAV SERVICE I 1 LAV KS, DW i I 1 I I I I I LAV LAV ! 1 KS, DW I KS, DW KS, DW I I KS, DW SERVICE 1 I I KS, DW 1 KS, DW LAV I I LAV I 1 2'W-Lr1 12" 2"I 12 I I I I W I I I I I WC I WC S I I 5 S I I 5 I WG I WC 1 2"1 12., I 1 WC W I WC I I S 3RD FLOOR I I I I r ! 1 I I I I I I I I LAV I I LAV I I I I I 1 I LAV LAV i I KS, DW I i KS, DW KS, DW I I KS, DW 1 SERVICE 1 I LAV SERVICE I I LAV K5, DW I 1 I KS, DW I KS, DW I I 1 1 W i ! W W I I W i I 1 W W I i S 2ND FLOOR I 1 1 WC 1 WC S I I S S i I S I WC I WC 1 I I i I WC WC ! ! I I -� I 1 I I I 1 LAV LAV I - -� I I I I I KS, DW I I KS, DW KS, DW I I KS, DW I SERVICE I -I LAV SERVICE r 1 LAV I KS, DW i KS, DW LAV I 1 LAV I I I I I I 1 I ! Lr- I W 15T FLOOR 1 WC 1 WC W I S S I I 5 S I 1 WG 1 WC S I WC W I WC 2" 2„ 3" 3 3 3 3" 3" 3„ 3„ 2„ 3" 3., 71 2" 4„ 4„ 4>, 4" Z4- 4" 6„ 6„ 6" 6„ 6„ 6„ 6„ 6„ 6„ 6„ 6„ @ 11 12 WFU 12 WFU 12 WFU 12 WFU 28 WFU 14 WFU 12 WFU 24 WFU 24 WFU 9 WFU 23 WFU 30 WFU 12 WFU 30 WFU 4" 4" 4„ ROOF 2,. �„ 1 2" 2" 2„ I , (f---J---- r---- TO RISER 14 -----� TO RISER 15 L----� TO RISER 22 r----- TO RISER 21 r- --� TO RISER 9 ---- -----� I--�--� TO RISER 21 r--2-� TO RISER 1$ 1 I I I I I I i 12" I I 1 1 1 1 2" ATTIC I 1 _ _ _ E-- I I I r---4 I I 1 I I I I I I I 1 I I LAV I 1 I KS, DW 1 KS, DW KS, DW I ! LAV LAV 1 1 W i i 1 W W I 1 I SERVICE LAV I I 1 2" 12" i i I 1 1 I 3RD FLOOR I I S 1 WC WC I 1 S Ir --E S 5 I I S I WC I I WC I I I I I 1 I I 1 r----I----- I I 1 I I LAV LAV I ! I 1 -_I I SERVICE V - -� I LAV I 1 1 KS, DW KS, D I I I I W I I W I I I 1 SERVICE I I -LIJ 2ND FLOOR I I S I WC WC I I S 5 I I S I WC 1 P. WC 1 1 l I I LAV - -, I LAUNDRY SINK i KS 2"1 1 I 3" 4" FLOOR DRAIN 1 ST FLOOR 1 1 P. WE 1 W ----- FROM RISER 25 -___�2„ 3" 3" 2" 3" 2„ 2" 2' -2" -__-� 2, _)TO RISER 15 4„ 4„ 4" 6„ 6„ 6„ 6" 6„ 6„ 6., 6" 6" 6„ 6,. 14 WFU 13 WFU 13 WFU 15 WFU 20 WFU 6 WFU 12 WFU 8 WFU 9 WFU 4 WFU 4 WFU RISER DIAGRAMS NTS CEMENT CONCRETE TG PER PLAN AAV 1- " MIN AAV T T 1-4" MIN HHWR HHWR HHWR 1-4" MIN CLASS 4000" CAST IRON LOCKING I COLLAR 028 RING AND COVER HW 1„ 1" 1" 1 1» 1„ 1» 1" 1" PAVED SURFACE 28" SQ FINISHED HWR GRADE HWC1 RBH RB RBH RBH RBH RBH BH RBH RBH CEMENT CONCRETE n1 ,> 1" CWS Q 6" GASKETED WH1 BH RB 2-j" BH HHW 2-1" BH RB HHW 2- " RB 2- RB RB HHW 2- " B O BOILER CONTRACTOR TO DESIGN AND BUILD PAINTED STEEL 12" PVC SPIGOT CAP 2- " HHWR 2-}" HHWR 2- " 2- - " HHWR 2- " HHWR 2-�" HHWR 2--4' " STRUCTURE FOR B-1 SUPPORT A. SLEEVE OR MECHANICAL MINIMUM OF 1" ABOVE B-2 TO PLUG (WATERTIGHT) ALLOW FUTURE REMOVAL AND GRAVEL gH {fig LBH— BH LBH BN BH B BH " REPLACEMENT OF B-2. SHOP BEDDING DOMESTIC HW4 TO EAST TO WEST 2- " 2 DRAWINGS ARE REQUIRED TO BE PIPE ATTACHED TO HOLBY VALVE WING OF WING OF REVIEWED BY ENGINEER BEFORE FIBER JOINT 45' BEND CEILING SYSTEM SYSTEM PACKING -TIE IN HHWR AT BOILER ROOM HHWR � CO �S TIE IN HHW AT BOILER ROOM 4 PIPE HHW II �I ASME RELIEF, 1" FACTORY SET DIA. MAX i II TO 125 PSI OR ADS1 SPACING 3WV MANUFACTURER'S WH2 Q p 2-4" T 2-1/2" HLP1 fa 2-4" T FROM 5 p RECOMMENDATION, PLUMB WITH 45" BEND PLUG TO BE SEALED 5 BENWYE IN THE SAME MANNER BV 2 2" ® 2- FROM 1" TYPE M COPPER F WITHIN AS MAIN SEWER JOINTS © PRESSURE GAUGE, LIQUID FILLED, � WINTERS Q805 OR EQUAL. � 6" VERTICALLY OVER FLOOR T ELECTRONIC TEMPERATURE SENSOR — P " DRAIN. BV -- BOILER PUMP BALANCING TO BE SUPPLIED BY THE CONTROLS CONTRACTOR AND INSTALLED BY DP VALVE, ARMSTRONG CBV-SF, TYPICAL. THE BOILER CONTRACTOR. TO FLOOR ELEVATION 1/2" 1/2" WIDE, I TRERICE SOLAR POWERED — __ � DRAIN 00 J" HOSE BIBB/DRAIN 1/S" HIGH THERMOMETER, MODEL SX9. SUPPLY VALVE RAISED � WITH 3-4 F2 THERMAL WELL. � 2-j" 2'"�" — 10" BORDER B1 62 R ROOM DETAIL IS DIAGRAMMATIC ON THE A CONTRACTOR SHALL FOLLOW ALL EQUIPMENT MANUFACT R Sr��K UNION B-1 I 2" BPI IN THE BOILER ROOM: A INSTRUCTIONS DURING INSTALLATION AND TESTING. IF TH BV " INSTALL BALL VALVES ON 8 3 4" CONTRACTOR IS UNSURE ABOUT ANY ELEMENT OF THE ti—Ipl�i BRONZE FULL PORT BALL 2 �1--- HHW AND HHWR SUPPLY o O INSTALLATION AND COMMISSIONING PROCESS, SUBMIT A T REMOTE FOR TEMPERATURE EAST AND WEST SECTIONS VALVE, APOLLO OR EQUAL SENSOR FOR BOILER AND RETURN FOR ISOLATING REQUEST FOR INFORMATION B TO THE ENGINEER FO f1 PRESSURE REGULATING © / BPI BP2 FURTHER DETAILS. ALSO, SEE BOILER P&ID FOR MORE AILED r-�-�} TEMPERATURE RESET. $" INFORMATION. P T O OF BUILDING. ALSO INSTALL VALVE. J" WATTS, SERIES � 2„ DUCT LOCATEDN FACO23 OUTSIDE AIR SYSTEM DRAINS ON RETURN 15" 3/4" RAISED ON HHW RETURN LINES. USLP OR EQUAL. �H LINES AND CHECK VALVES SQUARES DIFFERENTIAL PRESSURE TRANSDUCER, INSTALL PLACCARDS THAT SECTION A-A 3/4" APART, 1. �2 SUPPLIED BY CONTROLS CONTRACTOR, IDENTIFY EAST AND WEST 1/S" HIGH C Q ISOLATION A5 APPLICABLE. PLAN 3WV 3 WAY BALANCING VALVE B-2 2" BP2 2" NOTES 1 CLEAN-OUT PIPE AND FITTINGS CAST IRON RING WITH ACTUATOR, SEE M1 BV SHALL BE PVC. AND COVER ET2 2 A SANITARY TEE OR SWEEP MAY BE ADS1 SEE M1Tf INSTALLED IN LIEU OF A WYE AS SHOWN. I P T 2" STRAIGHT TEES ARE NM ACCEPTABLE. C�--�-fj BUSHING OR BELL REDUCER II--I® CLEAN-OUT SHALL CONFORM TO HHWR BM5 SEE M1 WSDOT STANDARD PLAN 9-18b CWS P � HHW ADS1 6" SEWER CLEANOUT Q Q Q � H BOILER ROOM PIPE DIAGRAM BOILER P&ID NTS iLju'u SEE P&ID'S FOR APPURTENANCES NTS APPROVED FOR CONSTRUCTION u DRAWN/DESIGNED BY: CAD FILE NUMBER: 1 8-31-09 CG CHANGED HLP-1 AND BV. � CHANDLER'S SQUARE INDEPENDENT LIVING BP/CG VENT]LATIONDIAGRAMS-09001 WA CHECKED BY: COUNTY: 2 1/18/10 BP ADDED SINK TO RISER 22, MODIFIED BOILER P&ID DETAIL. AO g CG SKAGIT 3 2/11/10 BP 3RD FLOOR HHWR PIPE SIZED �. DATE: JOB NUMBER: RRISON ENGINEERING ' 'i' 1t IFC D1/15/,0 09001 �1 f SCALE: REVIEWING ENGINEER DATE �' # � A N A V V R T E JURISDICTION 'T3lp 1T p HORIZONTAL SEE PLANS 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (350) 707-5858 RISER D I A G R A M S AND DETAILS N/A M 3 OF 1 Q T�az signed {{ VERTICAL No. DATE INIT. REVISION APPROVALS LINETYPES WASTE(W) VENT(V) — --- — — — COLD WATER(CW) HOT WATER(HW) ------- HOT WATER REfURN(HWR) — — -- HEATING HOT WATER(HHW) HEATING HOT WATER RETURN(HHWR) — FUTURE AIR CONDITIONING(AC) — — — — — SCALE: 3/16"=1' 118 HB1 w TIE INTO EXISTING SEWER w GAS GAS " GAS GAS GAJ" GAS GAS GAS Lo �l 116 OTC UP TO 141 143 145 117 0 FIREPLACE 12 WFU — — 4 WFU n w 12� 24 FU 28 wL=lJ � 125 I op n I Lu O CU s WFU 12 WFU 11 q 1 i SET INVE F- r BELOW Fl ISHED OOR I 3 I�7 WHEN PIP EXITS 12 WFU 14 WFU 23 WFU 13 WItiV--15 WFU 5 WFU 115 BUILDING., 369 WFU 345 WFU 321 WFU 263 WFU 237 WFU 189 WFU 174 WFU 1 1 WFU 95 WFU 91 WFU 65 WFU 30 WFU13 wm 6" WASTE 6" WASTE 6" WASTE v, 18 WFUSET CLFANOUT IN < LNVERS"OF CLEANOUT AT 1 PARKING LOT. SEE 10o E 12 WFU 12 WFU 13 WFU BELOW FlNISHED CIVIL PLANS FOR LOCATION. 4 11 FLOOR. 12 WFU opp � co � qnLi obL) dLQ � 20 WFU 30 WFU LD 0 0 T WATER t3 R URN 24 FLU 113 114 CE12C] WATER 122 ZLL::L -----—� ,�, 112 1 GAS GAS G GAS AS GAS GAS GAS a 9 WFU WH1 AT CEILING _ 9 WFU 12 WFU lb WFU — � � � w _ 11 3 HWFU — ❑ IwH2 FS1, 2 WFUw COLD WATER B1 121 1 4 �rB2 t— FS 1, 2 WFU FL'>-j 7 7 IN CEILING OF ST FLOOR 142 144w GAS GAS GAS G S GAS1 " GAS GAS GAS G S 2.5 CWFU or DCDA 2" GAS FIRE LINE FROM HYDRANT. BY OTHERS 146 COLD WATER SUPPLY, 21" TYPE L COPPER TO 2" GAS—SUPPLY METER FIREPLACE 13 0 20.5 MBH FIREPLACE 1 Q 37 MBH WATER HEATER 2 m 199 MBH BOILER 1 0 300 MBH BOILER 1 0 500 MBH DRYER 1 m 175 MBH TOTAL 1376.5 MBH DRAWN DESIGNED BY: CAD FILE NUMBER: APPROVED FOR CONSTRUCTION CHANDLER'S SQUARE INDEPENDENT LIVING BP/CG VENTILATIONDIAGRAMS-49001 CHECKED BY: COUNTY: Or— CG S KAG IT DATE: JOB NUMBER: A RRISON ENGINEERING ��` � IFC 01/15,10 REVIEWING ENGINEER DATE 09001 � AN ACORTES WA SCALE: JURISDICTION �tST � 47i A1, HORIZONTAL SEE PLANS 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707--5658 '1ST r L" WATER WASTE & VENT DIAGRAMS M 4 OF 10 No. DATE INIT. REVISION APPROVALS �at� Signet df f VERTICAL N/A LINETYPES WASTE(W) VENT(1M - - - - - - COLD WATER(CW) HOT WATER(HW) ------- HOT WATER RETURN(HWR) - - -- HEATING HOT WATER(HHW) - HEATING HOT WATER RETURN(HHWR) - FUTURE AIR CONDMONING(AC) -- --- - - - 4GM 4 G5 4"45 CFM. CFM. 12"x 12" USE TURNING jVANES IN "UP" , DIRECTION. SCALE: 3/16"=1 12"x14" 8"x8". TYPICAL 118 8"xB" ZONE219 S/A 1140 CFM R/A 990 CFM OSA 150 CFM 14"x 14" i FAC219 RBH-8 RM 118�—Ll RBH-8 SEE ARCHITECTURAL PLANS TG1 TG1 RTN M FOR FIREPLACE VENT DETAIL. FRI FAC125 RBH-10 RBH-10 RBH—B RBH—B RBH-12 SG9 14"X14" 150 CFM T V ZONE125 141 6M 143 145 117 S/A 720 CFM 640 R/A 720 CFM 8"x20" OSA 80 CFM w 163 CFM E7 El n SG8 16� 126 � � U n 125 4" SG8 n n n nn 163 n n U 4"0 11G CFM 8"x12" 8"x16" / CJ ° SG1 SG1 115 g --6 SG1 SG1 267 267 267 267 CFM RBH-6 " 8" 8 ° 10"x12" ° 10"x12" 19 1O"x20" RG4 0 6 C� 6" 1050 s" SG6 U� 12"x16" RELIEF AIR L 250 M 4mPk . 12 x16 SG6 250 10 INSTALL 4 4 OUTSIDE AIR O 114 O CFM 5' AFF 122 � 12"x16" 11� I� I 112 5' AFF SG5 250 " CFM " 8" DRYER 6" 600 I — — 4 EXHAUST SG5 OL3 6" 250 N CFM x 121 �- BF1 4"0 1 4 r G5 MINIMUM OF ZONE 121 250 12" AFF. ❑ S/A 1000 CFM FM 14"X8" EX/A 1000 CFM RG3 195 _ 195 1s FAC 121 95 CFMCFM CFM (;Fy 142 144 HHW HHWR 10'x1Qr r RBH-12 RBH-10 (D SG5 aL1 FC123 195 OL1 OSA INTAKE. TOP 100 CFM 1000 OF DUCT IS 12" CFM 8 g I ONJ • RBH—B RBH-8 6"o CFM BELOW CEILING OF ROOM 121 OL2 190 CFM ZONE 124 CONO. 5/A 780 CFM 146 %A SW CFM k 111D CFM RBH-•12 RBH-6 RBH-8 APPROVED FOR HYDRONIC HEATING CONSTRUCTION ONLY DRAWN/DESIGNED BY: CAD FILE NUMBER: 1 1/18/10 BP DUCTING AND AIR HANDLER RELOCATED IN RM 118 APPROVED FOR CONSTRUCTION II: CHANDLER'S SQUARE INDEPENDENT LIVING BP/CG VENT{LATIONDIAGRAMS-09001 0 ;VA CHECKED ft COUNTY: 1 2/10/10 BP DUCTING AND AIR HANDLER RELOCATED IN RM 125, HYDRONICS ADDED TO FC'S } CG SKAGIT r DATE: JOB NUMBER: A� RRISON ENGINEERINGy , IFC 01/15/10 0� o� REVIEWING ENGINEER DATE AN ACORTES, WA SCALE: 3 II JURISDICTION iA1� HORIZONTAL SEE PLANS 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707-5858 FIRST FLOOR HVAC N/A M5 OF VERTICAL 41lcc1 g tt (t Na. DATE INIT. REVISION APPROVALS i LINETYPES vm WASTE(W) VENT(V) — — — — — 7WATER WATER(CW) WATER(HW) ------- I ETURN(HWR) WATER(HHW) HEATIURN(HHWR) TIONING(AC) — — — — — n I ° I SCALE: 3/16"=1' I Ia I ❑ ' I I 4' WASTE ! 21q I ❑ • I ❑ I I . I 1 , J � I ❑ I I VTR Ij 218 • I I I I 241 243 245FYI�-IrE Lill 1� 1�yl I I 1 O 222 0 s i � � I I n � I � cl 1 ii I! - II 4 i. I' I. wl O O I O �1 5.6 CWFU o O I. 2 I I I W I 3.1 HWFU pp - �O O ------ --- " O 1" ob � 1 I• 1 � I cwFu I• � I- ❑ ---- -- I 1 -, 40 CWFU , 80 CWFU — . . —CW — — . . — . . .._ . . — . . — . . _ . , — - . . — . . _ . . — . . — — 131.5 CW - . . —CW +— 36.7 CWFU. ° 16.7 CWFU — — . . . . . -' . — . . __ . . — . . 15 HWFU . . — . . — - HWR— — —_ __------------------ ------------ --- — -- ---- ---- -- - -- 8.7 HWFU ------- -----11.7 HWFU ------ _ --------- ------- - 101 5 HWFU-------HW HWR 2 U _ _ —30 HWFU --------�--- - 60 HWFU -------HW--------- -- --- - 2 tj 200 1i" 1 " 1' 22.3 cwfu CIRCUIT 1 I 1- _ 17.3 HWFU SETTER. 3 GPM I I I 20 CWFU 15 HWFU 1 " 20 �FUI �" 211 i � . 2" 2�1 I 2� 17.5 HWF � 10 CWFU 1 � � I 1.1 CWFU 1 � ' 20 CWFU1� I^15 HWFI� 4.6 CWFU I 24.fi CWFU }I I I 1 „ 5CHWFU1.1iWFU 4 , ❑ i" I " 1 5 HWFU ❑ i" I 0 FU - F- 15 HWFU 1,� I 4.6 HWFU -� I 19.6 HWFU 2" ^ 2� I n 1A CWFU , 1 ,. I @ - I RO HIRD FLOOR 2 . III I 21' I - 6 1 O 9 HWFU II 1 O I I 1 � �O I I ,9 C FU I i 1.1 HWFU 00 j 00 I II I f l II I II 1 I I 1 0 O HIT I 1 1. R I 1 -- �— HWFU I 3 CWFU O COLD WATER I01 I • 242 244 n 283.5 CWFU 0 0 246 1 1 18 10 BP DRAWN/DESIGNED BY: CAD FILE NUMBER: / / WASTE AND SUPPLY ADDED TO P7 AT SOUTH END OF RM 219. APPROVED FOR CONSTRUCTION a CHANDLER'S SQUARE INDEPENDENT LIVING BP/CG VENTILATIONDIAGRAMS-09001 CHECKED BY: COUNTY: CG SKAGIT DATE: JOB NUMBER: REVIEWING ENGINEER DATE RRISON ENGINEERING WA l 01/15/10 D� JURI SDICTION A N A C U R T E S, HORIZONTAL SEE PLANS A A 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707-5858 EXPIRES l( WASTE & VENT DIAGRAMS VERTICAL WATER, WASTE I V I No. DATE INIT. REVISION APPROVALS 2ND FL. ATER� i UNETYPES ❑ 7 WASTE(W) VENT(V) — — — — — COLD WATER(CW) HOT WATER(HW) -------- HOT WATER RETURN(HWR) — — — HEATING HOT WATER(HHW) - HEATING HOT WATER RETURN(HHWR) — FUTURE AIR CONDITIONING(AC) — — — — — SG4 SG4 ® 263 263 ® SCALE: 3/1611=1' CFM CFM ° a Vv 21G ° o ® SG4 SG4 263 263 CFM CFM HHWyHHWR FROM ROOM 143 ° � FROM ROOM 141I F RG2 RM FROM ROOM 345 FROM ROOM 147 FROM ROOM 147 I 219 RTN Ta 9880 All 18 OO� �� FROM THIRD FLOOR TQ 80 i47 I 24' CFM f0 ROOM 145 -1 1 T M 7 TO ROOM 349 24 X14 FROM ROOM 143 RBH-8 I RBH-8 I FROM ROOM 143 FROM THIRD FLOOR FROM ROOM 145 ADM ROOM 145 RBH-8 TO ROOM 141 FROM ROOM 145 To R 4433 -�gypp }� 4q�,55 TTpp Rp MM 1445 Tp �80 aa q4, 1900 CFM TO ROOM 3 1 I I I I TO R 0 AV o TO R SM A45 RBH-S TO RO M 345 TO w I I I BF1 -VT I I� OL5 w 1 I BREEZEWAYRBH I — .-1 - _ —- - �--- - — — — - RBH-8 - i _ RBH_10 - - -—HHW - - - - - - - - - - — — — r - - — — --- — - - — — — - — HHWR- - — - - - - — — — IF 1771 FP1 TO ROOMHHW 3 I RBH-S 1 21� HHWR i 241 243 245 j I 1 247 .yawl I DRYER VENT (DV). I i TERMINATE METAL 0 DUCT WITHIN 2' OF 7 DRYER EXHAUST. 1 TYPICAL. FYI Hi I — I RANGE HOOD RH1) N i l DRYER (D1) I DISHWASHER (DW) RY FAN(LF1) VTR IN CHASE. j I 222 I WASHER (Wl) 00 BY ARCHITECT FP2 1 n i C I I � 7 216 4 � L JA U � � L J 0 I <\ , l TO ROOM 300 I I BATH FAN (BF1) I 1 ROM 31 � � nP1 p2 � I � FROM RODM 00�\ _j pli o ° VENT THROUGHSG1 SG1 ROOF (VTR) ° ° SG1 SG1 TO ROM 115 2D� I CFM CFM I I CFM CFM 1 215 1 TO ROOM 00 2 8"0 8"0 11 FROM ROOM 115 ° 10"x12" ° 10"x12" ° - - - �111 — O O b.w 10"X20" RO4 , S Q Q IIII Q o s"� 0 I i50 N5 TED LINE SETS FOR 3 uo Q-1 ( 12"x16" RE EF R TON AC (FUTURE). TERMINATE M M 16�x20� INSIDE ROOM AT CEILING. 4" 4"� 12"x16" �� O O III 4 0 EL OUTSIDE,�41R " " =1 1s x1s 213 I,I� � J \ L�jl jI ?�T E212 I / — II » 1� VA — — I ❑ 4w � III � 6» 600 1 I 600 6»f6 . I 248 25� I � II 0 0 FROM ROOM 142 j — » FROM ROOM 144 — — _— - H I I HHWR - - - - - - - - - - - - RBH-12 I i 1 i I h RBH-10 1 I I i 1 RBH-12 I I RBH-10 I I I IHHO TO R00M 142 TO ROOM 144 I 246 I 1 I I I TO ROOM 342 RBH-8 RBH-8 TO ROOM 344 I I I 1 LINESETS TO RBH-10 J RBH-8 I TO ROOM 350 TERMINATE FROM ROOM 142 FROM ROOM 144 I OUTSIDE WALL OF 1 I i RM. 121. 1 TO ROOM 142 TO ROOM 144 TO ROOM 342 I I 1 TO ROOM 348 TO ROOM 350 I TO ROOM 344 1 CD1 TO ROOM 348 RBH-12 I RBH-8 � HEATING NOTE: SEE HYDRONIC HEATING DETAIL FOR TYPICAL HEATER HOOK FROM ROOM 146 �H- FROM ROOM 146 UPS. TO ROOM 146TO ROOM 346 TO ROOM 146 APPROVED FOR HYDRONIC HEATING CONSTRUCTION ONLY TO ROOM 346 J TO ROOM 146 FROM ROOM 146 A TO ROOM 346 1 18/10 BP SG4 MODIFIED AND RG2 ADDED TO RM 219 APPROVED FOR CONSTRUCTION DRAWN/DESIGNED BY: CAD FILE NUMBER: 2 2 1 1 10 BP AC LINES MODIFIED, 2ND HHW PIPE ADDED IN RM 248, HYDRONICS ADDED TO FC'S CHANDLER'S SQUARE INDEPENDENT LIVING BP/CG VENTILATIONDIAGRAMS-09001 ' r WA t CHECKED BY: COUNTY: W CG SKAGIT x RRISON ENGINEERING DATE. JOB NUMBER: IFC 01/15/10 REVIEWING ENGINEER DATE JURISDICTION 3 i, i � A N A C O R T E S, ��/►■ A SCALE: 09001 iatA1 :� HORIZONTAL SEE PLANS 1997 PARK LANE, BURLI NGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 747-5858 SECOND FLOOR H V A C M 1 No- DATE INIT. REVISION APPROVALS �3a� Sf Berl VERTICAL N/A 0 i UNMPES WASTE(W) VENT(V) — — — - -- COLD WATER(CW) HOT WATER(HW) ------- HOT WATER RETURN(HWR) --- — — HEATING HOT WATER(HHW) — HEATING HOT WATER RETURN(HHWR) — SCALE: 3/16"=l' FUTURE AIR CONDITIONING(AC) — — — — — i -7 li 341.0 Pyl 343 345 347 � 34G 0 0 0 n E FY�cl -- [ 1 I I i I 1• F u I I I I I 0 0 0 I O O w 5 w .I w I Iw O __ �O o� _ __ _ _ ' --7 O� � 1 I I F• 1w 1 1 1� @ -- - ❑ 5 HWFU ❑ CWFU -. W — .: _ . . —° , — - . — . fid.� — °—HWR C1N IN — • — • • — . . — . . _ -- _ . . — . . — . , _ . . ._ --HWR-- U - r ---15 HWFU -------- 30 HWFU ----- --HW------- ----------- ---- -------- ------- --------- --_ 51.9 HWFU-------HW— - - --- HWF ------ 1 F t 1 7.5 HWFU I w r--- i 1 12.3 CWFU � " 5 HWFU i 10 CW 3 I 9.8 HWFU w 7.5 HW 10 CWFU . w w J00 1 10 CWFUw t ' 10 i I 1• 1 . to CIRCUIT w CIRCUIT 1 1 1 1 2.3 CWFU�- I 1�8 HW STER, 3 GPM 2 I SETTER, 3 GPM _� 0 CWFU I i- 7 5 W �I i� 10 CWFU r�-7.5wWF�� 2.3 HWFU—-i 9. I 106.9 CWFU IIto � 10 CWFU �. 7.5 HWFU ° 1 ❑ ❑ ` 81.9 HWFU ^7.5 HWFU o -in in F I 1 i i I pECOND I O op iw6 Io j I oR uu I I. �O L Ll ,1- 4 I do I• O� I I Ob o 0 I 1 313 - _ k I I --- ----- -------- ---- -------- -- 1 312 I - -------- ----------- Op ° b. O � I 350 342 � 344 34H a 346 DRAWN/DESIGNED BY: CAD FILE NUMBER. APPROVED FOR CONSTRUCTIONS ( BP/CG VENTILATIONDIAGRAMS-09001 CHANDLER'S SQUARE INDEPENDENT LIVING C4 CHECKED BY: COUNTY: K CG 5 KAG IT DATE: JOB NUMBER: RRISON ENGINEERING 31581 1FC 01/15/10 090O1 REVIEWING ENGINEER DATE AN A C O R T E S, WA SCALE: JURISDICTION HORIZONTAL SEE PLANS /� 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707-5858 EXPIRES l� 3RD FL. WATER, WASTE & VENT DIAGRAMS VERTICAL N/A M 8 OF No. DATE INIT. REVISION APPROVALS i i LI NETYPES WASTE(W) VENT(V) - - - - - COLD WATER(CW) HOT WATER(HW) ------- HOT WATER RETURN(HWR) — - — HEATING HOT WATER(HHW) - HEATING HOT WATER RETURN(HHWR) - FUTURE AIR CONDITIONING(AC) - - - - - SCALE: 3/16"=1' RBH-8 I RBH-B I RBH-8 I RBH-8 I I RBH-6 I RBH-12, - _ . - _ _ . _ _ . _ _ . _ _ . � RBH-10 -10 - RBH-10 RBH--10 i I j 341 ry, 343 345 I 347 FYI 034G 600 600 I 6"� 6~ ❑ I Y FLUE SH FROM I 600 SECO D M I 316 ❑ I '. . . FLoo I E E ❑ ❑ - -L IL) f� o o C-7 6 6' ❑ 10 1 1 4 0 0 0 L-7 RBH-4 I — . . SG1 SG1 ° ° © ° SG1 SG1 3 CFM GF� _ CFM CFMI ~I 00 � � 315 311 8"� 10"X20" 8~ ° 10"x12" ° 10"x 12" ° 6 — — 6" CFM 0 O " o s � I i 0 N5 LATED LINE SETS FOR 3 q 12'x16" TON AC (FUTURE). TERMINATE C� IE- M R2EDL 24" ZNSI E ROOM AT CEILING. J714 E- " LL I 12"x 16" O 4 0 4 0 I u 4"0 4~0 a 20 xx24" 313 20" X 24" VENTILATION DUCT 1 ❑ ❑ \\\ 312 10 ❑ " AN ~ S OEMA ° 1 1 ❑ 4" ° s CES5 ATCH II s 6~�� 6"� ~O 6"0 I II 342 u II I i I fi RBH-12 I I RBH_10 ( I V I RBH-10 o I RBH-12 I I I I I I RBH-8 I RBH-8 I I RBH-10 RBH-8 1 346 I i6"0 4"m I RBH-12 I RBH-8 RBH-6 APPROVED FOR HYDRONIC HEATING CONSTRUCTION ONLY 1 2/11/10 BP AC LINES MODIFIED, AAV ACCESS HATCH RELOCATED TO RM 312 APPROVED FOR CONSTRUCTION DRAWN/DESIGNED BY: CAD FILE NUMBER: HYDRONICS ADDED TO FC'S CHANDLERS SQUARE INDEPENDENT LIVING BP/CG VENTILATIONDIAGRAMS-09001 WA CHECKED BY: COUNTY: 1 ' CG SKAGIT RRISON ENGINEERING DATE: JOB NUMBER: REVIEWING ENGINEER DATE IFC 01/15/10 " � ANACORTES, WA SCALE: 09001 JURISDICTION 7iV � HORIZONTAL SEE PLANS 1997 PARK LANE, BURLINGTON, WA 98233 PHONE (360) 707-5656 FAX (360) 707-5858 7-�- THIRD FLOOR HVAC VERTICAL N/A M9 OF 10 No. DATE INIT. REVISION APPROVALS jDate Signed