Loading...
HomeMy WebLinkAboutBLD-2025-0402 - SOLAR PERMITFor inspections, please call (360) 293-1901 PARCEL: P32217 LEGAL DESCRIPTION: APPLICANT: Haziq, Mustafa 12820 Avondale Way everett, wa, WA 98204 4254876000 OWNER: SAMISH INDIAN NATION UNKNOWN ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 3510.00 $3,510.00 $3,510.00Total: FEES:Paid Due Plan Review Fee $63.21 $0.00 Building Permit Fee $97.25 $0.00 State Building Code Council fee $6.50 $0.00 $0.00Totals : REQUIRED INSPECTIONS Solar Final $166.96 BLD-2025-0402 SOLAR PERMIT ISSUED: EXPIRES: 06/11/2025 06/11/2027 PROJECT NAME: SAMISH XWCH'ANGTENG COTTAGE AT 2110 34TH STREET SITE ADDRESS: 2110 34TH STREET ANACORTES * If you answered yes to all of the above questions, your PV installation is eligible for a building permit. CONDITIONS Page 1 of 1Printed by : Cheri Gleichmann on: 07/30/2025 06:42 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ SHEET NO. & NAME PV-0COVER SHEET GR I D - T I E D 8 . 3 6 k W D C , 1 6 k W A C S O L A R P V S Y S T E M W/ 2 8 . 6 k W h D C E N E R G Y S T O R A G E SA M I S H N A T I O N X W C H ' A N G T E N G C O T T A G E S 21 1 0 3 4 T H S T AN A C O R T E S , W A 9 8 2 2 1 RE V DA T E D R RE V I S I O N D E S C R I P T I O N 1. 0 5/ 7 / 2 5 WH INSTALLER: FORECAST SOLAR LLC ADDRESS: 12820 AVONDALE WAY EVERETT, WA 98204 PHONE: 425-487-6000 EMAIL: INFO@FORECASTSOLAR.COM LICENSE: GC - FORECRL955MK LICENSE: EC - FORECRS883DG 1 VICINITY MAP SCALE: N.T.S. 2 AERIAL VIEW SCALE: N.T.S. PV-0 COVER SHEET PV-1 SITE PLAN PV-2 ROOF PLAN PV-3 ELECTRICAL SINGLE LINE DIAGRAM PV-4 FIELD LABELING REF ENGINEERING REPORT REF EQUIPMENT SPECIFICATIONS SCOPE OF WORKTHIS PROJECT INVOLVES THE INSTALLATION OF A GRID-INTERACTIVE PV SYSTEM WITH ENERGY STORAGE. PV MODULES WILL BE ROOF- MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO DC CONVERTERS AND DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY COMPANY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION DIRECTORY OF PAGES PROPERTY OWNER SAMISH INDIAN NATION PROPERTY ADDRESS 2110 34TH STREET, ANACORTES, WA 98221 APN P32217 ZONING SINGLE FAMILY USE AND OCCUPANCY CLASSIFICATION RESIDENTIAL, GROUP R-5 AHJ CITY OF ANACORTES UTILITY COMPANY PUGET SOUND ENERGY ELECTRICAL CODE NEC 2023 (NFPA 70) FIRE CODE 2021 IFC OTHER BUILDING CODES IBC 2021 IRC 2021 UPC 2021 IMC 2021 PROJECT DETAILS SITE DESIGN PARAMETERS DRY BULB EXTREME LOW -9 DEG C DRY BULB 0.4% HIGH 25 DEG C DATA SOURCE ASHRAE DATASET WHIDBEY ISLAND WIND (ASCE 7-16)110 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 30 PSF PV SYSTEM DETAILS DESCRIPTION NEW GRID-INTERATACTIVE PHOTOVOLTAIC SYSTEM WITH ENERGY STORAGE DC RATING 8.36 KW AC RATING 16 KW INVERTERS/MIDS (1) EG4 FLEXBOSS21 / EG4 GRIDBOSS PV MODULES (19) SILFAB SIL-440QD OPTIMIZERS (19) TIGO TS4-A-O ENERGY STORAGE (2) EG4 POWERPRO 14.3kWh BATTERIES PV ARRAY WIRING (1) STRINGS OF 7 TS4-A-O OPTIMIZERS (1) STRINGS OF 6 TS4-A-O OPTIMIZERS (1) STRINGS OF 6 TS4-A-O OPTIMIZERS GENERAL NOTES 1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. (NEC 690.61). 2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT) CONDUIT FITTING SHALL BE RAIN TIGHT THREAD-LESS COMPRESSION TYPE. 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. MARKINGS SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS, PANEL BOARDS, DISCONNECTING SWITCHES, TERMINAL CABINETS, ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER. 5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. 6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 7. SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS. 8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 9. JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S) SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM. (NEC 690.34). 10. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 11. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC 300.6 (1), 310.8 (D)). 12. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM. (NEC 250.97). 13. THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN #6 COPPER WIRE. (NEC 250.64 (B)). 14. GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (NEC 250.64 (C)). 15. RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END. (NEC 250.64 (E)). SHEET NO. & NAME PV-1SITE PLAN GR I D - T I E D 8 . 3 6 k W D C , 1 6 k W A C S O L A R P V S Y S T E M W/ 2 8 . 6 k W h D C E N E R G Y S T O R A G E SA M I S H N A T I O N X W C H ' A N G T E N G C O T T A G E S 21 1 0 3 4 T H S T AN A C O R T E S , W A 9 8 2 2 1 RE V DA T E D R RE V I S I O N D E S C R I P T I O N 1. 0 5/ 7 / 2 5 WH INSTALLER: FORECAST SOLAR LLC ADDRESS: 12820 AVONDALE WAY EVERETT, WA 98204 PHONE: 425-487-6000 EMAIL: INFO@FORECASTSOLAR.COM LICENSE: GC - FORECRL955MK LICENSE: EC - FORECRS883DG N 1 SITE PLAN SCALE: 1" = 12' 34TH STREET PARCEL BOUNDARY A SILFAB SIL-440QD SOLAR MODULES CONNECTED TO SOLAREDGE SE-S440 DC-TO-DC CONVERTERS. ROOF-MOUNTED. B MICROGRID INTERCONNECTION DEVICE (SOLAR RAPID SHUTDOWN & ENERGY STORAGE SYSTEM DISCONNECT) C HYBRID INVERTER & BATTERIES EQUIPMENT LEGEND AND GENERAL NOTES D UTILITY METER & MAIN SERVICE DISCONNECT SHEET NOTES 1. UTILITY-OWNED EQUIPMENT IS SHOWN FOR REFERENCE PURPOSES ONLY. IT IS NOT FOR CONSTRUCTION AND MAY BE CHANGED BY THE UTILITY AT ANY TIME. 2. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL PSE EQUIPMENT. 3. ALL PLAQUES AND SIGNAGE REQUIRED BY THE 2023 NEC AND 2021 IFC WILL BE INSTALLED AS REQUIRED 4. A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS, THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS, AND THE ENERGY STORAGE SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56. D B A C EQUIPMENT SITE / JOB DETAILS Roof Type Composite Shingle Roof Pitch 4:12, 8:12 Azimuth 90,180,270 degs System Weight 1,020 lbs Total Array SQ FT 399 sq.ft. Total PSF 2.56 lbs/sq.ft. Weight per mount 26.8 lbs/mount Mount Spacing 6' Staggered Wind Speed 110 mph Snow Load 30 lbs/sq.ft. Installation Drawn by:Will Habenicht Approved on: Array Size DC 8.36 kW System Size AC 16 kW Modules 19x Silfab Prime Module Model SIL-440-QD Module Dimension 44.6"x67.8"x35m Inverter EG4 Inverter Model FLEXBOSS21 MID Model EG4 GRIDBOSS Racking System IronRidge Racking Color BLACK Mounts 38x FLASHVUE 204" XR100 Rails 0 186" XR100 Rails 5 168" XR100 Rails 6 Splice Kits 0 Grounds 11 End Clamp 24 Mid Clamps 26 SHEET NO. & NAME PV-2ROOF PLAN GR I D - T I E D 8 . 3 6 k W D C , 1 6 k W A C S O L A R P V S Y S T E M W/ 2 8 . 6 k W h D C E N E R G Y S T O R A G E SA M I S H N A T I O N X W C H ' A N G T E N G C O T T A G E S 21 1 0 3 4 T H S T AN A C O R T E S , W A 9 8 2 2 1 RE V DA T E D R RE V I S I O N D E S C R I P T I O N 1. 0 5/ 7 / 2 5 WH INSTALLER: FORECAST SOLAR LLC ADDRESS: 12820 AVONDALE WAY EVERETT, WA 98204 PHONE: 425-487-6000 EMAIL: INFO@FORECASTSOLAR.COM LICENSE: GC - FORECRL955MK LICENSE: EC - FORECRS883DG N 1 SCALE: 1" = 6' 2 SITE/EQUIPMENT DETAILS SCALE: N.T.S ROOF PLAN DRIVEWAY 4: 1 2 8:12 7: 1 2 7: 1 2 SHEET NOTES 1. ALL EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS 2. SEE REFERENCE PAGES FOR ATTACHMENT DETAILS AND ENGINEERING REPORT 3. PER MAUNFACTURER, MAX RAIL SPAN IS 91 INCHES AND MAX RAIL CANTILEVER IS 36 INCHES 4. MAINTAIN 18 INCHES FROM ALL HORIZONTAL RIDGES PER WAC 51-54A 1204.2.1, EXCEPTION 5 A SILFAB SIL-440QD SOLAR MODULES CONNECTED TO SOLAREDGE SE-S440 DC-TO-DC CONVERTERS. ROOF-MOUNTED. B IRONRIDGE XR100 RAILS C IRONRIDGE FLASHVUE MOUNTS EQUIPMENT LEGEND AND GENERAL NOTES D MICROGRID INTERCONNECTION DEVICE (SOLAR RAPID SHUTDOWN & ENERGY STORAGE SYSTEM DISCONNECT) E HYBRID INVERTER & BATTERIES F UTILITY METER & MAIN SERVICE DISCONNECT A B C D F E SHEET NO. & NAME PV-3ELECTRICAL SINGLE LINE DIAGRAM GR I D - T I E D 8 . 3 6 k W D C , 1 6 k W A C S O L A R P V S Y S T E M W/ 2 8 . 6 k W h D C E N E R G Y S T O R A G E SA M I S H N A T I O N X W C H ' A N G T E N G C O T T A G E S 21 1 0 3 4 T H S T AN A C O R T E S , W A 9 8 2 2 1 RE V DA T E D R RE V I S I O N D E S C R I P T I O N 1. 0 5/ 7 / 2 5 WH INSTALLER: FORECAST SOLAR LLC ADDRESS: 12820 AVONDALE WAY EVERETT, WA 98204 PHONE: 425-487-6000 EMAIL: INFO@FORECASTSOLAR.COM LICENSE: GC - FORECRL955MK LICENSE: EC - FORECRS883DG ELECTRICAL EQUIPMENT SCHEDULE TAG QTY.DESCRIPTION A 19 SILFAB SIL-440QD 440WDC SOLAR MODULE CONNECTED TO TIGO TS4-A-O DC-TO-DC CONVERTER. 8.36 kW CAPACITY. ROOF-MOUNTED B 1 ROOFTOP JUNCTION: WATERTIGHT HEYCO SADDLE WITH MC-4 FITTINGS OR WATERTIGHT JUNCTION BOX C 1 EG4 FLEXBOSS21 HYBRID INVERTER. TESTED UNDER UL9540A AND LISTED UNDER UL9540 AS A SINGLE UNIT WITH BATTERIES (D) D 2 EG4 POWERPRO ALLWEATHER BATTERIES (14.3kWh EACH) TESTED UNDER UL9540A AND LISTED UNDER UL9540 AS A SINGLE UNIT WITH INVERTER (C). LOCATED ON EAST SIDE OF HOUSE E 1 EG4 GRIDBOSS MICROGRID INTERCONNECTION DEVICE. ACTS AS SERVICE DISCONNECT, SOLAR RAPID SHHUTDOWN INITIATING DEVICE AND ENERGY STORAGE SYSTEM DISCONNECT. CO-LOCATED WITH EXISTING UTILITY METER (H) F 1 RELIANCE PB30 GENERATOR INLET. LOCATED OUTSIDE BY MID (E). G 1 EXISTING MAIN DISTRIBUTION PANEL. SQUARE D HOMELINE. 200A MAIN BREAKER TO BE FED BY MID (E). H 1 EXISTING UTILITY ELECTRICAL METER (#X181187920) AND SEVICE DISCONNECT. LOCATED ON WEST EXTERIOR WALL OF HOUSE. I 1 EXISTING UTILITY TRANSFORMER 200A 200A200A 90A RSD GEN PARALLEL PORTS G MANUAL BYPASS GEN GRID RELAYSSMART PORTS HYBRID INVERTER RELAYS RS485 E 300A DC AC GRID AC IN/OUT BAT INV INV C 1 40A 200A LEGEND: PV WIRE, THWN, USE-2 GROUNDING CONDUCTOR RS-485 WIRE CAT5/6 CABLE CONDUCTOR SCHEDULE B 2 3 TIGO TAP 30A4 G F H I TIGO CCA 5 6 TAG CIRCUIT TYPE DESCRIPTION CONDUIT TYPE CONDUIT FILL V DROP 1 DC-TO-DC CONVERTER SOURCE CIRCUIT (DC, CU, PV WIRE)(6) #10, (1) #8 EGC, FREE AIR N/A N/A 0.39% (@50') 2 DC-TO-DC CONVERTER OUTPUT CIRCUIT (DC, CU, USE-2)(6) #10, (1) #8 EGC, (1) #14/4 TC-ER, 1" CONDUIT EMT 27.40%0.23% (@30') 3 INVERTER TO BATTERY CIRCUIT (DC, CU, EG4 PROVIDED CABLE)(4) 2/0 IN EG4 WIRE TROUGH N/A N/A 0.32% (@6') 4 INVERTER TO MID OUTPUT CIRCUIT (AC, CU, THWN)(3) #3, (1) #8 EGC, 1 1/4" CONDUIT PVC 21.87%0.79% (@60') 5 MID TO MAIN DISTRIBUTION PANEL CIRCUIT (AC, CU, THWN)(3) 3/0, (1) #6 EGC, 2" CONDUIT PVC 24.58%0.12% (@8') 6 MID TO GENERATOR INLET CIRCUIT (AC, CU, THWN)(3) #8, (1) #8 EGC. 3/4" CONDUIT PVC/EMT 26.73%0.1% (@6') SOLAR RAPID SHUTDOWN AND ENERGY STORAGE SYSTEM DISCONNECT MP P T 1 MP P T 2 MP P T 3 30A 30A 25A TIGO TAP 250A 250A D 24V 1 2 3 4 TO OVEN TO DRYER TO HEATPUMP RSD N TO WATER HEATERTIGO TAP 200A G UTILITY M SI N G L E L I N E D I A G R A M MU L T I L I N E D I A G R A M CO N D U I T FR E E A I R GR O U N D - L E V E L RO O F T O P +- STRING 1: (7) MODULES CONNECTED IN SERIES TO (7) TIGO TS4-A-O DC-TO-DC CONVERTERS +-+- +- STRING 2: (6) MODULES CONNECTED IN SERIES TO (6) TIGO TS4-A-O DC-TO-DC CONVERTERS +-+- +- STRING 3: (6) MODULES CONNECTED IN SERIES TO (6) TIGO TS4-A-O DC-TO-DC CONVERTERS +-+- EGC A SHEET NO. & NAME PV-4FIELD LABELING NEC 690.56(C)(1) AND IFC 1205.4.1 NEC 705.12(B)(3)(3) NEC 690.13(B) NEC 690.56(C)(3) AND IFC 1205.4.3 NEC 690.53 NEC 690.31(D)(2) NEC 706.15(C) GR I D - T I E D 8 . 3 6 k W D C , 1 6 k W A C S O L A R P V S Y S T E M W/ 2 8 . 6 k W h D C E N E R G Y S T O R A G E SA M I S H N A T I O N X W C H ' A N G T E N G C O T T A G E S 21 1 0 3 4 T H S T AN A C O R T E S , W A 9 8 2 2 1 RE V DA T E D R RE V I S I O N D E S C R I P T I O N 1. 0 5/ 7 / 2 5 WH INSTALLER: FORECAST SOLAR LLC ADDRESS: 12820 AVONDALE WAY EVERETT, WA 98204 PHONE: 425-487-6000 EMAIL: INFO@FORECASTSOLAR.COM LICENSE: GC - FORECRL955MK LICENSE: EC - FORECRS883DG PV SYSTEM DC DISCONNECT OPERATING CURRENT: OPERATING VOLTAGE: MAXIMUM SYSTEM VOLTAGE: SHORT CIRCUIT CURRENT: ENERGY STORAGE SYSTEM DISCONNECT MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: NOMINAL ESS AC VOLTAGE: DATE CALCULATION PERFORMED: SOLAR RAPID SHUTDOWN SWITCH 1 FIELD PLACARDS & SIGNAGE SCALE: 1" = 1" THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING! SOLAR SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! ELECTRIC SHOCK HAZARD SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING PHOTOVOLTAIC POWER SOURCE 234 V 20 A 327 V 13.2 A 240 V 60 V 100 A 05/07/25 System Weight Total system weight 1,020.3 lbs Weight/attachment 30.0 lbs Racking weight 140.6 lbs Distributed weight 2.5 psf Load Assumptions Wind exposure B Wind speed 110 mph Ground snow load 30 psf Attachment spacing portrait 6.0' Site Elevation 249.0 ft SDS 1.0 Project Details Name Samish Cottages Date 05/02/2025 Location 2109 34th Street, Anacortes, WA 98221 Total modules 19 Module Silfab: SIL-440QD (35mm)Total watts 8,360 Dimensions Dimensions: 67.76" x 44.61" x 1.38" (1721.0mm x 1133.0mm x 35.0mm)Attachments 34 ASCE 7-16 Rails per row 2 Roof Information Roof Material Family Comp Shingle Roof material Comp Shingle Risk category II Roof attachment FlashVue Staggered attachments Yes Attachment hardware T Bolt Roof shape Gable Specific gravity 0.42 Samish Cottages (#1444549)pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 1 of 13Last updated by Will Habenicht on 05/02/25 02:50 PM Side View (portrait) (18-33)° Roof slopes: (18, 30, 33)° PV MODULE RAIL FLASHVUE ROOF MEMBRANE BUILDING STRUCTURE Front View (portrait) 6.0’ ATTACHMENT SPAN Roof slopes: (18, 30, 33)° PV MODULE RAIL FLASHVUE ROOF MEMBRANE BUILDING STRUCTURE RAFTER Samish Cottages (#1444549)pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 10 of 13Last updated by Will Habenicht on 05/02/25 02:50 PM Splice Details INTERNAL SPLICE SIDE-FACING SLOT TOP-FACING SLOT XR100 XR100 RAIL BONDING SPRING XR100 INTERNAL SPLICE Splice Connection Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULEFRAME UNIVERSAL FASTENING OBJECT FlashVue Detail 8" 12" 2.07" Plan View 2.1" Side View Perspective View 2.74" 1.87" Front View Samish Cottages (#1444549)pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 11 of 13Last updated by Will Habenicht on 05/02/25 02:50 PM Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Samish Cottages (#1444549)pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 12 of 13Last updated by Will Habenicht on 05/02/25 02:50 PM Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails® are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail® Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails® is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails® are compatible with FlashFoot® and other pitched roof attachments. IronRidge® offers a range of tilt leg options for flat roof mounting applications. All XR Rails® are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail® Family The XR Rail® Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail® to match. © 2023 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.22 Tech Brief Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 90 120 140 XR10 XR100 XR1000 160 20 90 120 140 160 30 90 160 40 90 160 80 160 120 160 XR100 XR100 is a residential and commercial mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. • 10’ spanning capability• Heavy load capability• Clear & black anodized finish• Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. • 6’ spanning capability• Moderate load capability• Clear & black anodized finish• Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans up to 12 feet for commercial applications. • 12’ spanning capability• Extreme load capability• Clear anodized finish• Internal splices available *Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. Tech Brief Simplified Grounding for Every Application The UFO® family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge® XR Rails®. All system types that feature the UFO® family—Flush Mount®, Tilt Mount® and Ground Mount®—are fully listed to the UL 2703 standard. UFO® hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO® Family of Components Universal Fastening Object (UFO®) The UFO® securely bonds solar modules to XR Rails®. It comes assembled and lubricated, and can fit a wide range of module heights. Stopper Sleeve The Stopper Sleeve snaps onto the UFO®, converting it into a bonded end clamp. BOSS® Splice Bonded Structural Splice connects rails with built-in bonding teeth. No tools or hardware needed. Bonded Attachments The bonding bolt attaches and bonds the L-foot® to the rail. It is installed with the same socket as the rest of the system. Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Only for installation and use with IronRidge products in accord with written instructions. See IronRidge.com/UFO System Diagram UL Certification The IronRidge® Flush Mount®, Tilt Mount®, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. © 2022 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information. Version 1.23 Tech Brief Cross-System Compatibility Feature Flush Mount Tilt Mount Ground Mount XR Rails®XR100 & XR1000 UFO®/Stopper  BOSS® Splice N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Compatible with most MLPE manufacturers.Refer to system installation manual. Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed ModulesRefer to installation manuals for a detailed list. í Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. Go to IronRidge.com/UFO © 2021 IronRidge, Inc. WA Flush Mount System Certification Letter - 1 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: 6HSWHPEHU tK, 2021 Re: Structural Certification and Span Tables for the IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge’s Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8” stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. •ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) •2018 International Building Code (IBC-2018) •2018 Washington State Building Code •2015 Aluminum Design Manual (ADM-2015) •Report SEAOC (Structural Engineer Association of California) PV2-2017 Wind Design for Solar Arrays The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8° to 45°. The tabulated spans are applicable when the following conditions are met: 1.Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener). 2.Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 3.The underlying roof slope, measured between the roof surface and horizontal plane, is 8º to 45º. 4.The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 5.A clearance from the underside of the array to the roof surface of 2” minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h2), shall not exceed 10”. 6.Module length and area shall not exceed the maximum values listed on the respective span tables. 7.All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge’s Flush Mount Installation Manual and other applicable standards for the general roof construction practice. © 2021 IronRidge, Inc.WA Flush Mount System Certification Letter - 4 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, PE Senior Structural Engineer 2021.09.07 15:55:03 -07'00' © 2024 IRONRIDGE, INC. VERSION 4.4 XR FLUSH MOUNT INSTALLATION MANUAL - 2 RATINGS Product markings are located on the Grounding Lug bolt head. MARKINGS UL 2703 LISTeD Conforms to UL STD 2703 Standard for Safety First edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels • Scope of Evaluation includes bonding, grounding, mechanical loading, and fire classification • Max Overcurrent Protective Device (OCPD) Rating: 40A • Max Module Size: 30.5 ft² • Module Orientation: Portrait or Landscape • System Design Load Rating: 10 PSF downward, 5 PSF upward, 5 PSF lateral • Actual system structural capacity including spans and cantilevers are defined by PE stamped certification letters • CAMO Specific Design Load rating: 50 PSF downward, 50 PSF upward, 15 PSF lateralCertified to CSA TIL No. A-40 Photovoltaic Module Racking Systems • Load Rating: 2400 PA [50 PSF] CLASS A SYSTeM FIRe RATING PeR UL 2703• Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25, 29 and 38: Allowed with any roof slope. Any module-to-roof gap is permitted, with no perimeter guarding required• Module Types 4 and 5: Allowed with Steep Slope Roofs (≥ 9.5°). Any module-to-roof gap is permitted, low edge guarding (Trim) required• Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire ratingCLASS B SYSTeM FIRe RATING PeR UL 2703• Module Types 4 and 5: Allowed with Steep Slope Roofs (≥ 9.5°). Any module-to-roof gap is permitted, with no perimeter guarding required. WATeR SeAL RATINGS: • UL 441 and TAS100(A) (Flashfoot2, L-Mount, Flashvue, All Tile Hook, Knockout Tile, Halo UltraGrip) • Tested and evaluated without sealant • Any roofing manufacturer approved sealant is allowed. • Ratings applicable for steep roof slopes 2:12 and above. UL 2703A RATINGS: • Conforms to UL SUBJECT 2703A - Halo UltraGrip and BUG • Steep Slope Ratings applicable for Asphalt Shingle roofs with slopes 2:12 and up • Low Slope Ratings applicable for Roll Roofing (Rolled Comp) roofs with slopes 1:12 and up • Low Slope Ratings applicable for Modified Bitumen (Mod-Bit) roofs with slopes 1/4:12 and up • Installer must verify roof slope prior to installing HUG or BUG to validate applicable roof types CONFORMS TO UL STD 1565 AND CeRTIFIeD TO CSA C22.2 #18.5-13 POSITIONING DeVICeS - WIRe CLIP • Operating Temperature Range: -35 to 90C • Maximum Load: 10lbs • For outdoor use STRUCTURAL CeRTIFICATION• Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 FLORIDA PRODUCT APPROVAL #FL29843 • Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ) • Additional details and full list of approved components can be found here #5003807 #5028987 Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, Wisconsin 53562 Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) Signature: Name: Nalini Mandadi Position: Project Engineer Date: 11/14/2014 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: Enstall US, Inc. 41 West Putnam Avenue, Suite 303 Greenwich, CT 06830-5300 USA Product Description: Flush Mount System with XR Rails. Ratings & Principle Characteristics: Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low and Steep Slope applications when using Type 1, 2, 3, 13, 19, 25, 29 and 38 listed photovoltaic modules, no perimeter guarding is required. Class A Fire Rated for Steep Slope applications when using Type 4 and 5 listed photovoltaic modules and required perimeter low edge guarding. Class B Fire Rated for Steep Slope applications when using Type 4 and 5 listed photovoltaic modules, no perimeter guarding is required. Tested with a 5” gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. This rating is applicable with any 3rd party roof attachment with similar construction and material. Models: IronRidge Flush Mount with XR Rails Brand Name: IronRidge Flush Mount Relevant Standards: UL 2703 (2023)(Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive, Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, 104428358MID-001 EEV, 105041839MID-001 & 002, 105499394MID-008 PEV Revision Summary 08/27/2020 Added type 13, 19, 25 and 29 to system, update address. 06/28/2022 Added Type 5. 09/14/2022 Added Type 4. 12/8/23 added type 38. 1/5/24 changed word anchor to attachment. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Brian Brunson Reviewed by: Chad Naggs Title: Operations Manager, Middleton Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 01/05/24 Date: 01/05/24 Tech Brief Moving Flashing Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large viewport, for easy alignment with the pilot hole. And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. FlashVue™ GripCap & GripCap+ The 360º capable GripCap (2.74” tall) and GripCap+ (3.74” tall) can be placed in any orientation, and provide a “friction-fit” for easy installs. Push snug into the viewport, without worrying it will roll away or rotate while driving the lag. Three-Tier Water Seal, Reimagined FlashVue’s seal architecture utilizes three layers of protection. The viewport is elevated 0.30”, and provides a “friction-fit” for the GripCap. The GripCap fully covers the viewport while a sealing washer adds another layer of protection. And an EPDM washer and lag bolt “seal the deal” in the stack. Large Viewport in Flashing The large viewport makes it easy to align the flashing with the pilot hole, and drive the lag centered into the rafter. The elevated rim not only provides a sturdy dock for the GripCap or GripCap+, but increases water-shedding capabilities. ⌀ 0.75” Triple Certified to Protect the Roof™ UL 2703, 441 (27)TAS 100(A)-95 © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Solve Roof Undulations See Your Pilot Holes Also Available: GripCap+ We know roofs are not always perfectly flat. GripCap+ can help when undulations get in the way. Large Viewport in Flashing FlashVue makes pilot holes highly visible, like never before. No more tedious guesswork on hot roofs. Trusted Strength & Certification Attachment Loading FlashVue has been tested and rated to support 1161 (lbs) of uplift and 353 (lbs) of lateral load. Structural Certification Designed and certified for compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Passed both the UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. UL 2703 Listed System Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info.     SIL-440 QD • Improved Shade Tolerance • Improved Low-Light Performance • Increased Performance in High Temperatures • Enhanced Durability • Reduced Degradation Rate • 25-Year Product Warranty/ 30-Year Performance Warranty NEXT-GENERATION N-TYPE CELL TECHNOLOGY SILFABSOLAR.COM NTC SIL-440 QD MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 21 kg ± 0.2 kg 46.3 lbs ± 0.4 lbs Dimensions (H x L x D)1721 mm x 1133 mm x 35 mm 67.8 in x 44.6 in x 1.37 in Maximum surface load (wind/snow)*4000 Pa rear load / 5400 Pa front load 83.5 lb/ft2 rear load / 112.8 lb/ft2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 108 Half cells - N-Type Silicon solar cell 182 mm x 91 mm 108 Half cells - N-Type Silicon solar cell 7.16 in x 3.58 in Glass 3.2 mm high transmittance, tempered, antireflective coating 0.126 in high transmittance, tempered, antireflective coating Cables and connectors (refer to installation manual)1350 mm, ø 5.7 mm, MC4 from Staubli 53.1 in, ø 0.22 in (12 AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized aluminum (Black) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated, 3 diodes TEMPERATURE RATINGS Temperature Coefficient Isc 0.04 %/°C Temperature Coefficient Voc -0.24 %/°C Temperature Coefficient Pmax -0.29 %/°C NOCT (± 2 °C)45 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 98% end 1st yr ≥ 94.7% end 12th yr ≥ 90.8% end 25th yr ≥ 89.3% end 30th yr SHIPPING SPECS Modules Per Pallet:26 or 26 (California) Pallets Per Truck 32 or 30 (California) Modules Per Truck 832 or 780 (California) CERTIFICATIONS Product UL 61215, UL 61730, CSA C22.2#61730, IEC 61215, IEC 61730, IEC 61701 (Salt Mist Corrosion), IEC 62716 (Ammonia Corrosion), CEC Listed, UL Fire Rating: Type 2 Factory ISO9001:2015 * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. ELECTRICAL SPECIFICATIONS 440 Test Conditions STC NOCT Module Power (Pmax)Wp 440 328.0 Maximum power voltage (Vpmax)V 33.41 31.17 Maximum power current (Ipmax)A 13.17 10.52 Open circuit voltage (Voc)V 38.97 36.64 Short circuit current (Isc)A 14.22 11.44 Module efficiency %22.6% Maximum system voltage (VDC)V 1000 Series fuse rating A 25 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m² • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10 W. 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 info@silfabsolar.com SILFABSOLAR.COM 7149 Logistics Lane Fort Mill SC 29715 USA T +1 839.400.4338 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-440-QD-20240829 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2024. Silfab Solar® is a registered trademark of Silfab Solar Inc. SILFAB SOLAR INC. 44 . 6 " [ 1 1 3 3 m m ] 11.8" [300.5mm]44.1" [1120mm]11.8" [300.5mm] Ø0 . 1 7 " [ Ø 4 . 2 m m ] ( x 2 ) Gr o u n d i n g H o l e Mounting Hole (x4) Drainage Hole (x8) 43 " [ 1 0 9 3 m m ] 2.4" [60mm]8" [200mm] 53.15" [1350mm] Cable Length 1.4" [35mm] 1. 4 " [ 3 5 m m ] 0.06" [1.5mm] 67.8" [1721mm] 1. 4 " [ 3 5 m m ] 0.5" [12mm] 0. 3 " [ 7 m m ] 0. 6 " [ 1 5 m m ] Sid e Ba c k V i e w Pr o f i l e ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED. VERSION 1.1.1 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE. MODEL #: MI-200-2P-HYB-AW-01 EG4® GRID BOSS MICRO-GRID INTERCONNECTION DEVICE (MID) The EG4 GridBOSS Micro-Grid Interconnection Device (MID) simplifies Energy Storage Systems (ESS) by consolidating multiple components into a single, innovative unit. It replaces traditional elements such as the point of common connection, back-fed breakers, feeder taps, tap breakers, supply-side taps, transfer switches, and dedicated combiner panels for grid-in, grid-out, and generator input. As a versatile solution, the GridBOSS serves as the service entrance equipment* when paired with the utility meter, providing a single point of connection for utilities, hybrid inverters, generators, smart loads, and AC-coupled inverters. CENTRALIZED ESS CONTROL Provides a single point of connection for utility, hybrid inverters, generators, smart loads, and AC-coupled inverters. REDUCED ESS COMPLEXITY Replaces up to 10 components with one unit, including point of common connection, back-fed breakers, feeder taps, feeder tap breakers, supply side taps & breakers, transfer switches, and dedicated combiner panels for grid-in, load/EPS, and generator input. SERVICE ENTRANCE RATED 200 Amp service entrance with a 22 kAIC main breaker, acts as service entrance equipment in conjunction with a utility meter and a 200A Eaton braker (CSR25K). REMOTE MONITORING Enable remote monitoring, configuration, and firmware updates through the EG4 mobile app or online monitoring system. SMART PORTS Includes load shedding, which disconnects loads during low battery voltage and reconnects on high voltage. Power shedding connects loads when at full SOC and PV flow and disconnects on low SOC or PV loss. 200A SERVICE ENTRANCE* 4 CONFIGURABLE SMART PORTS INTEGRATED GENERATOR SUPPORT 19.7 in. (500 mm) 31 . 5 in . ( 80 0 mm ) 7 in . (17 8 mm ) *When used with an Eaton 200A main breaker (model CSR25K). TECHNICAL SPECIFICATIONS GRID NOMINAL AC VOLTAGE 120/240VAC (L1/L2/N required) FREQUENCY 60 Hz MAXIMUM CURRENT 200A SERVICE ENTRANCE RATED 22kAIC with 200A Eaton breaker (model: (CSR2200N) CSR25K) GENERATOR NOMINAL VOLTAGE 120/240VAC (L1/L2/N required) FREQUENCY 60 Hz MAXIMUM CURRENT 125A NON-BACKUP NOMINAL VOLTAGE 120/240VAC (L1/L2/N required) FREQUENCY 60 Hz MAXIMUM CURRENT 200A BACKUP NOMINAL VOLTAGE 120/240VAC (L1/L2/N required) FREQUENCY 60 Hz MAXIMUM CURRENT 200A HYBRID NUMBER OF PORTS 3 NOMINAL VOLTAGE 120/240VAC (L1/L2/N required) FREQUENCY 60 Hz MAXIMUM CURRENT PER PORT 70A* SUPPORTED INVERTERS** EG4® 12kPV, 18kPV, & FlexBOSS21 SMART PORTS NUMBER OF PORTS 4 NOMINAL VOLTAGE 120/240VAC (L1/L2/N required) FREQUENCY 60 Hz MAXIMUM CURRENT PER PORT 1: 125A | 2: 80A | 3: 60A | 4: 60A GENERAL DATA COMMUNICATION INTERFACE RS485/Wi-Fi/CAN INTERNAL BUS RATING 350A INTERNAL FUSE RATING 315A OPERATING ALTITUDE <6561 ft (<2000 m) RELATIVE HUMIDITY 0 – 100% OUTDOOR RATING NEMA 3R OPERATING AMBIENT TEMPERATURE RANGE -40°F – 140°F (-40°C – 60°C) PRODUCT DIMENSIONS (H×W×D) 31.5×19.7×7 in (800×500×178 mm) UNIT WEIGHT 55 lbs. (25 kg) STANDARD WARRANTY 10-year standard warranty STANDARDS AND CERTIFICATIONS UL1741, UL67, UL869A*** FCC PART 15, CLASS B (PENDING) *Install a properly sized breaker based on the connected inverter: 50A - 12kPV; 70A - 18kPV; 90A - FlexBOSS21. **Third party inverters are not supported and cannot be connected to the hybrid ports. ***When used with an Eaton 200A main breaker (model (CSR2200N) CSR25K). ©2024 EG4® ELECTRONICS, LLC. ALL RIGHTS RESERVED. VERSION 1.1.1 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE. MODEL#: IV-16000-HYB-AW-FX-00 EG4® FLEXBOSS21 HYBRID INVERTER The EG4 FlexBOSS21 is a versatile 48V split-phase, hybrid inverter/charger that offers the same dependable power as the 18kPV with enhanced flexibility. Powerful enough to start a 5-ton AC unit, the FlexBOSS21 supports up to 21kW of PV input. Capable of paralleling up to 16 units together, the FlexBOSS21 has an impressive total output of 560kW. Able to provide 16kW of continuous output power with PV & battery, and up to 12kW continuous output by using battery alone. Three individual MPPTs give users optimal control over their solar needs, while the updated EG4 monitoring software allows for convenient total remote management, complete with mobile notifications and remote setting. Seamless interaction with the EG4 GridBOSS gives users control over the entire Energy Storage System (ESS). ALL-IN-ONE HYBRID INVERTER Capable of running entirely off grid, using grid electricity, and selling power back to the grid. UP TO 600VDC INPUT The extra high voltage enables lower cable sizing for the 3 MPPTs and a maximum recommended PV input of 24kW, eliminating the need for a combiner box. PLUG-IN WI-FI DEVICE Enables wireless connection between our monitoring platform and the FlexBOSS21 through the EG4® app or EG4 Monitor system for remote system management. CLOSED-LOOP COMMUNICATIONS Able to communicate with EG4 48V batteries and other battery brands. A battery firmware update is required for closed-loop communications with LifePower4 batteries. RAPID SHUTDOWN The FlexBOSS21 is CSA C22.2#330:2017 and NEC 690.12 ready with its built-in RSD capabilities. HIGH FREQUENCY SPLIT-PHASE DESIGN 10-YEAR WARRANTY REMOTE ADJUSTMENT VIA EG4 SOFTWARE 22.28 in. (566 mm) 30 . 43 in . ( 77 3 mm ) 11 . 2 2 i n . ( 28 5 mm ) TECHNICAL SPECIFICATIONS AC INPUT DATA NOMINAL AC VOLTAGE 120/240VAC; 120/208VAC (L1/L2/N required) FREQUENCY 60 Hz (Default) | 50 Hz MAX. AC CURRENT 50A @ 240V | 57.7A @ 208V MAX. AC INPUT POWER 12kW MAX. AC BYPASS 90A AC GRID OUTPUT DATA MAX. OUTPUT CURRENT 66.7A OUTPUT VOLTAGE 120/240VAC; 120/208VAC (L1/L2/N required) OPERATING VOLTAGE RANGE 180 – 270VAC NOMINAL POWER OUTPUT w/ PV: 16000W @240V | 13800kW @208V w/ out PV: 12000W @240V | 12000W @208V OUTPUT FREQUENCY 60 Hz (Default) | 50 Hz POWER FACTOR .99 @ Full Load REACTIVE POWER ADJUST RANGE (-0.8) – (+0.8) Leading Adjustable THD @FULL LOAD <5% TRANSFER TIME 20ms (Default), 10ms (Configurable) | Parallel – 20ms BACKUP/UPS AC OUTPUT DATA RATED OUTPUT CURRENT (240 | 208VAC) 50A | 57.7A NOMINAL OUTPUT VOLTAGE 120/240 | 120/208 VAC RATED OUTPUT POWER 12kW @ 240VAC | 12kW @ 208VAC PEAK POWER 24kW (.5 sec) 18kW (1 sec) 15kW (6 min) 13.2kW (12 min) OPERATING FREQUENCY 60 Hz (Default) | 50 Hz THDV (TOTAL HARMONIC DISTORTION VOLTAGE) <5% TRANSFER TIME 20ms (Default), 10ms (Configurable), 20ms (Parallel) PV INPUT DATA NUMBER OF MPPTS 3 INPUTS PER MPPT 2 (MPPT 1) | 2 (MPPT 2) | 1 (MPPT 3) MAX. USABLE INPUT CURRENT 26A (MPPT 1) | 26A (MPPT 2) | 15A (MPPT 3) MAX. SHORT CIRCUIT INPUT CURRENT 31A (MPPT 1) | 31A (MPPT 2) | 19A (MPPT 3) DC INPUT VOLTAGE RANGE 100 – 600VDC UNIT START-UP VOLTAGE 100VDC MPPT OPERATING VOLTAGE RANGE 120 – 440VDC NOMINAL MPPT VOLTAGE 360VDC MAX. UTILIZED SOLAR POWER 21kW MAX. RECOMMENDED SOLAR INPUT 25kW EFFICIENCY CEC 96.9% MAX. EFFICIENCY (PV TO GRID) 97% MAX. EFFICIENCY (BATTERY TO GRID) 94% MAX. EFFICIENCY (PV TO BATTERY) 94.5% IDLE CONSUMPTION (NORMAL) | (STANDBY MODE) <80W | <60W BATTERY DATA COMPATIBLE BATTERY TYPES Lead-acid/ Lithium MAX. CHARGE/DISCHARGE POWER 12000W NOMINAL VOLTAGE 48VDC VOLTAGE RANGE 40 – 60 VDC RECOMMENDED BATTERY CAPACITY PER INVERTER >300Ah GENERAL DATA MAX. UNITS IN PARALLEL 16 PRODUCT DIMENSIONS (H×W×D) 30.43 × 22.28 × 11.22 in. (750 × 520 × 285 mm) UNIT WEIGHT 88 lbs. (52 kg) DESIGN TOPOLOGY High Frequency – Transformerless RELATIVE HUMIDITY 0 – 100% OPERATING ALTITUDE <6561 ft (<2000 m) OPERATING AMBIENT TEMPERATURE RANGE -13° – 140°F (-25° – 60°C) STORAGE AMBIENT TEMPERATURE RANGE -13° – 140°F (-25° – 60°C) NOISE EMISSION (TYPICAL) <50dB @ 3 ft COMMUNICATION INTERFACE RS485/Wi-Fi/CAN STANDARD WARRANTY 10-year standard warranty* OUTDOOR RATING NEMA 4X SAFETY FEATURES Integrated DC disconnect, Reverse polarity protection, Output over-voltage protection varistor, Output over current protection, Ground fault monitoring, Grid monitoring, Pole sensitive leakage current monitoring unit, AFCI, RSD STANDARDS AND CERTIFICATIONS UL1741, SA, SB, PCS CRD California Rule 21 Phase I, II, III Arc-Fault Circuit Interrupter (AFCI) NEC 2020:690.11/UL1699B Ground Fault Monitoring (GFDI) NEC 2020:690.41(B) CSA 22.2.107.1:2016 Ed. 4 CSA 22.2.330:2017 Ed. 1 IEEE 1547.1:2020; IEEE 1547:2018 Hawaii Rule 14H [HECO SRD IEEE 1547.1-2020 Ed. 2] Rapid Shutdown (RSD) NEC 2020:690.12 FCC Part 15, Class B (PENDING) *See EG4 Warranty Registration for terms and conditions ©2024, EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED. VER. 1.1 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE. MODEL #: WPower-16/280-AW SCAN FOR UPDATED DOCUMENTS POWERPRO WALLMOUNT ALL WEATHER LITHIUM BATTERY The PowerPro WallMount All Weather 280Ah batteries are ideal for low-voltage residential outdoor energy storage system (ESS) applications. The batteries use lithium iron phosphate cells with the highest safety performance and an intelligent Battery Management System (BMS) that can monitor and record the voltage of each cell along with the current, voltage, and temperature of the module in real-time. The BMS also contains a passive balance function and an advanced battery control method, both of which improve the performance of the battery pack. BUILT-IN 200A BMS INTEGRATED 600A BUSBARS 82.6MWh LIFETIME PRODUCTION* 10 YEAR WARRANTY >8000 CYCLES @ 80% DOD ON-BOARD LCD TOUCH SCREEN Easy to see BMS monitoring, and selectable closed-loop communications with EG4, Schneider, Sol-Ark, Victron, Growatt, Megarevo, Luxpower, and Deye inverters. DUAL ON-BOARD FIRE ARRESTORS Offer fail-safe protection against thermal runaway. WEATHER-TIGHT QUICK CONNECTS Included battery cables with outdoor rated connectors allowing for fast, safe, and reliable battery connections. INTEGRATED SELF-HEATING FEATURE Heats the battery when the ambient temperature is low. A key feature for outdoor Lithium battery cell operations. INTEGRATED BUSBARS The battery design comes manufactured with 600A internal busbars with multiple terminals (4 positive & 4 negative) eliminating the need for external busbars when paralleling batteries and/or multiple inverters. INNOVATIVE EMERGENCY STOP FUNCTION The optional ESS disconnect can shut down all batteries and inverters (if equipped with rapid shut down capability) with the press of a button. THE PERFECT PARTNER TO THE EG4 18kPV The optional conduit box mates up directly to the connection ports of the inverter allowing a sleek and efficient installation. For other inverters or stand-alone battery installation, the conduit box plugs should be installed. ©2024, EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED. VER. 1.1.0 | SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. www.eg4electronics.com SPECIFICATION SHEET MODULE OPERATING PARAMETERS Parameter BMS Recommended Charger Settings Total Energy Capacity 14.3kWh @25C, 100% SOC - Voltage 51.2V - Capacity 280Ah ±2% @25°C ±2°C @ 0.5C Charging Voltage (Bulk/Absorb) 56.0V (±0.8V) 56.2V (±0.2V) Float - 54V (±0.2V) Low DC Cutoff 44.8V 47-45.6V (start higher, lower as needed) Charge Current 100/140/200A Max. Continuous** 60 - 160A Discharge Current 200A Max. Continuous 160A ENVIRONMENTAL PARAMETERS Charging Range 32°F to ≈113°F (0°C to ≈45°C) Discharging Range -4°F to ≈122°F (-20°C to ≈50°C) Storage Range -4°F to ≈122°F (-20°C to ≈50°C) Ingress Protection IP65 CHARGING/DISCHARGING PARAMETERS Charge Spec Delay Recovery Cell Voltage Protection 3.8V 1 sec 3.45V Module Voltage Protection 60V 1 sec 55.2V Charge Over-Current 1 >205A 10 sec - Charge Over-Current 2 >225A 3 sec - Temperature Protection <23°F or >158°F <-5°C or >70°C 1 sec >32°F or <140°F >0°C or <60°C Discharge Spec Delay Recovery Cell Voltage Protection 2.3V 1 sec 3.1V Module Voltage Protection 44.8V 1 sec 48V Discharge Over-Current 1 >205A 10 sec 60 sec Discharge Over-Current 2 >300A 3 sec 60 sec Short Circuit 2000A 0.1 ms - Temperature Protection <-4°F or >167°F <-20°C or >75°C 1 sec >14°F or <149°F (>-10°C or <65°C) PCB Temperature Protection >230°F (>110°C) 1 sec @ <176°F (<80°C) GENERAL SPECIFICATIONS Parameter Spec Condition Cell Balance 120mA Passive Balance Cell Voltage Difference >40mV Temperature Accuracy 3% Cycle Measurement Measure Range: -40°F – ≈212°F (-40°C – ≈100°C) Voltage Accuracy 0.5% Cycle Measurement Cells & Module Current Accuracy 3% Cycle Measurement Measure Range: -200 – 200A SOC 5% Integral Calculation Power Consumption (Standby) <300uA Standby/Storage Power Consumption (Operating) <25mA Charging/Discharging Communication Ports RS485/CAN Customizable ©2024, EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED. VER. 1.1.0 | SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. www.eg4electronics.com BATTERY HEATER SPECIFICATIONS Parameter Spec Condition Voltage 56V - Power Consumption 224W - Internal Battery Temperature ≤32°F (0°C) or ≥41°F (5°C) Heat On/Heat Off PHYSICAL SPECIFICATIONS Dimensions (H × W × D) 34.6 × 22.3 × 9.1 in. (88 × 56.6 × 23.2cm) Weight 308.6 lbs. (140 kg) Design Life >15 years Cycle Life >8000 Cycles @ 0.5C 80% DOD Lifetime Production 82.6MWh* *(51.2V×280Ah/1000×80%×8000 cycles/1000)90%=MWh **The default BMS in the module allows for 100A charging current maximum. To achieve higher charging currents, please contact your distributor for optional firmware files, or navigate to https://eg4electronics.com/downloads/ for the most up to date firmware.