HomeMy WebLinkAboutBLD-2025-0242 - SOLAR PERMITFor inspections, please call (360) 293-1901
PARCEL: P56056
LEGAL DESCRIPTION:
APPLICANT: Western Solar
4041 Home Rd, Ste A
Bellingham, WA 98226
360-746-0859
OWNER: WALTERS RYAN R
UNKNOWN
ANACORTES, WA 98221
VALUATIONS:
Estimated construction cost 1897.80 $1,897.80
$1,897.80Total:
FEES:Paid Due
Plan Review Fee $43.03 $0.00
Building Permit Fee $66.20 $0.00
State Building Code Council fee $6.50 $0.00
$0.00Totals :
REQUIRED INSPECTIONS
Solar Final
$115.73
BLD-2025-0242 SOLAR PERMIT
ISSUED:
EXPIRES:
04/28/2025
04/28/2027
PROJECT NAME: WALTERS - SOLAR
SITE ADDRESS: 1803 10TH ST ANACORTES
* If you answered yes to all of the above questions, your PV installation is eligible for a building permit.
CONDITIONS
Page 1 of 1Printed by : Cheri Gleichmann on: 07/25/2025 11:03 AM
City of Anacortes, WA
904 6th Street
Anacortes, WA 98221
(360) 293-1901
http://cityofanacortes.org/
SETBACKS:
RIDGE : 18"
EDGE : 36"
BETWEEN ARRAY : 18"
REC 460W Clamping Zone:
Portrait: 10" - 14"
Landscape: 7.9" - 11.8"
Notes:
Exterior/Interior DC Conduit Runs
to be labled as:
"Photovoltaic Conductors"
Main Disconnect to be Identified as:
"Photovoltaic Power Source"
Design meets requirements of:
WAC 51-54A-0605
Section 605.11.1.1, 605.11.1.2
(30) REC 460AA-PURE-RX, 460 Watt Photovoltaic Modules
Total System Size: 13,800 Watts DC, 13.8 kWs
Modules Dimensions: 68" x 47.4" x 1.18"
Pitch: 18° & 26°
Roof Area: 2,751.14 sq. ft.
Module Area: 681.42 sq. ft.
Percent of Coverage: 24.77 %
Max Rail Span Per Engineering :
Portrait - 69/58/53
Lanscape - 81/71/67
Prime Consultants Inc.
dba. Western Solar Inc.
4326 Pacific Hwy
Bellingham, WA 98226
LIC#: WESTES*910J0
_____________________
Project Manager:
Brandon Simpson
4326 Pacific Hwy
Bellingham, WA 98226
Tel: 360-746-0859
Installing Electrician:
Prime Consultants Inc.
dba. Western Solar Inc.
4326 Pacific Hwy
Bellingham, WA 98226
LIC#: WESTES*872DD
_____________________
Client Name:
Ryan Walters
1803 10th St
Anacortes, WA 98221
Total Project Size:
13.8 kW PV System
_____________________
Drawn by:
Morgan MacIntyre, WSI
Issue Date:
04/21/2025
_____________________
Site Map
5 1510
Parcel - P56056
Solar Modules
Setbacks
~60'
~100'
Detached Roof.
Setbacks not required
via email by Rob Frisinger
Roof Mounted Junction Box
Prime Consultants Inc.
dba. Western Solar Inc.
4326 Pacific Hwy
Bellingham, WA 98226
LIC#: WESTES*910J0
_____________________
Project Manager:
Brandon Simpson
4326 Pacific Hwy
Bellingham, WA 98226
Tel: 360-746-0859
Installing Electrician:
Prime Consultants Inc.
dba. Western Solar Inc.
4326 Pacific Hwy
Bellingham, WA 98226
LIC#: WESTES*872DD
_____________________
Client Name:
Ryan Walters
1803 10th St.
Anacortes, WA 98221
Project Size:
13.80 kW PV System
_____________________
Drawn by:
Brandon Simpson, WSI
Issue Date:
04/15/2025
_____________________
One Line Diagram vs1
Existing Solar Net Meter
Located West Exterior
Enphase IQ AC Interconnect Cables
Black - L1, Red - L2
Module PV Wire with MC4 Connectors
(6) #12 THHN,
(1) #12 Ground
240VAC Sub-Array
Combiner Panel
AC Disconnect
Initiates Rapid Shutdown
(3) 20 Amp, 240VAC Solar Interconnect Breakers
Circuit 1 - 3 :(1.58 Amps max output per inverter) x (10 inverters in parallel) = (15.80 A)
(15.80 A) x (1.25 NEC Safety Factor) = (19.75 A Maximum Output Current)
All conductors from rooftop junction box
to combiner are pulled through 3/4" ENT
raceways per NEC
(3) #6 THHN,
(1) #10 Ground
(30) REC 460AA-PURE-RX, 460 Watt Photovoltaic Modules
Total System Size: 13,800 Watts DC, 13.80 kWs
Modules Dimensions: 68" x 47.4" x 1.18"
Vmp=54.9 V, Imp=8.38 A, Voc=65.3 V, Isc=8.88 A
Installed as (3) Strings of (10) Modules with
(10) Enphase IQ8X Microinverters in parallel
**REMOVAL OF EXISTING 2010 SYSTEM INSTALLED BY FIRE MOUNTAIN**
*REMOVAL OF PRODUCTION METER*
60 Amp, 240VAC Solar Interconnect Breaker
(1.58 Amp Peak Output) x (30 Microinverters) = (47.40 A)
(47.40 A) x (1.25 NEC Safety Factor) = (59.25 A Maximum Output Current)
200A 240VAC
Homeline Main Panel
Located Interior
125A 240VAC
Homeline Sub Panel
Located Interior Basement
200A 240VAC
Derated Main Breaker to 175A
Homeline Main Panel
Located West Exterior
200A Service Disconnect
AC Disconnect
Initiates Rapid Shutdown
Collocated w/ Meter