Loading...
HomeMy WebLinkAboutBLD-2025-0242 - SOLAR PERMITFor inspections, please call (360) 293-1901 PARCEL: P56056 LEGAL DESCRIPTION: APPLICANT: Western Solar 4041 Home Rd, Ste A Bellingham, WA 98226 360-746-0859 OWNER: WALTERS RYAN R UNKNOWN ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 1897.80 $1,897.80 $1,897.80Total: FEES:Paid Due Plan Review Fee $43.03 $0.00 Building Permit Fee $66.20 $0.00 State Building Code Council fee $6.50 $0.00 $0.00Totals : REQUIRED INSPECTIONS Solar Final $115.73 BLD-2025-0242 SOLAR PERMIT ISSUED: EXPIRES: 04/28/2025 04/28/2027 PROJECT NAME: WALTERS - SOLAR SITE ADDRESS: 1803 10TH ST ANACORTES * If you answered yes to all of the above questions, your PV installation is eligible for a building permit. CONDITIONS Page 1 of 1Printed by : Cheri Gleichmann on: 07/25/2025 11:03 AM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ SETBACKS: RIDGE : 18" EDGE : 36" BETWEEN ARRAY : 18" REC 460W Clamping Zone: Portrait: 10" - 14" Landscape: 7.9" - 11.8" Notes: Exterior/Interior DC Conduit Runs to be labled as: "Photovoltaic Conductors" Main Disconnect to be Identified as: "Photovoltaic Power Source" Design meets requirements of: WAC 51-54A-0605 Section 605.11.1.1, 605.11.1.2 (30) REC 460AA-PURE-RX, 460 Watt Photovoltaic Modules Total System Size: 13,800 Watts DC, 13.8 kWs Modules Dimensions: 68" x 47.4" x 1.18" Pitch: 18° & 26° Roof Area: 2,751.14 sq. ft. Module Area: 681.42 sq. ft. Percent of Coverage: 24.77 % Max Rail Span Per Engineering : Portrait - 69/58/53 Lanscape - 81/71/67 Prime Consultants Inc. dba. Western Solar Inc. 4326 Pacific Hwy Bellingham, WA 98226 LIC#: WESTES*910J0 _____________________ Project Manager: Brandon Simpson 4326 Pacific Hwy Bellingham, WA 98226 Tel: 360-746-0859 Installing Electrician: Prime Consultants Inc. dba. Western Solar Inc. 4326 Pacific Hwy Bellingham, WA 98226 LIC#: WESTES*872DD _____________________ Client Name: Ryan Walters 1803 10th St Anacortes, WA 98221 Total Project Size: 13.8 kW PV System _____________________ Drawn by: Morgan MacIntyre, WSI Issue Date: 04/21/2025 _____________________ Site Map 5 1510 Parcel - P56056 Solar Modules Setbacks ~60' ~100' Detached Roof. Setbacks not required via email by Rob Frisinger Roof Mounted Junction Box Prime Consultants Inc. dba. Western Solar Inc. 4326 Pacific Hwy Bellingham, WA 98226 LIC#: WESTES*910J0 _____________________ Project Manager: Brandon Simpson 4326 Pacific Hwy Bellingham, WA 98226 Tel: 360-746-0859 Installing Electrician: Prime Consultants Inc. dba. Western Solar Inc. 4326 Pacific Hwy Bellingham, WA 98226 LIC#: WESTES*872DD _____________________ Client Name: Ryan Walters 1803 10th St. Anacortes, WA 98221 Project Size: 13.80 kW PV System _____________________ Drawn by: Brandon Simpson, WSI Issue Date: 04/15/2025 _____________________ One Line Diagram vs1 Existing Solar Net Meter Located West Exterior Enphase IQ AC Interconnect Cables Black - L1, Red - L2 Module PV Wire with MC4 Connectors (6) #12 THHN, (1) #12 Ground 240VAC Sub-Array Combiner Panel AC Disconnect Initiates Rapid Shutdown (3) 20 Amp, 240VAC Solar Interconnect Breakers Circuit 1 - 3 :(1.58 Amps max output per inverter) x (10 inverters in parallel) = (15.80 A) (15.80 A) x (1.25 NEC Safety Factor) = (19.75 A Maximum Output Current) All conductors from rooftop junction box to combiner are pulled through 3/4" ENT raceways per NEC (3) #6 THHN, (1) #10 Ground (30) REC 460AA-PURE-RX, 460 Watt Photovoltaic Modules Total System Size: 13,800 Watts DC, 13.80 kWs Modules Dimensions: 68" x 47.4" x 1.18" Vmp=54.9 V, Imp=8.38 A, Voc=65.3 V, Isc=8.88 A Installed as (3) Strings of (10) Modules with (10) Enphase IQ8X Microinverters in parallel **REMOVAL OF EXISTING 2010 SYSTEM INSTALLED BY FIRE MOUNTAIN** *REMOVAL OF PRODUCTION METER* 60 Amp, 240VAC Solar Interconnect Breaker (1.58 Amp Peak Output) x (30 Microinverters) = (47.40 A) (47.40 A) x (1.25 NEC Safety Factor) = (59.25 A Maximum Output Current) 200A 240VAC Homeline Main Panel Located Interior 125A 240VAC Homeline Sub Panel Located Interior Basement 200A 240VAC Derated Main Breaker to 175A Homeline Main Panel Located West Exterior 200A Service Disconnect AC Disconnect Initiates Rapid Shutdown Collocated w/ Meter