HomeMy WebLinkAboutBidSet-2009-Addendum 1 & 2 -_____.
�
�
�lM � �
� > �� �, :� � yt f� �
� � ��� � � : _
�
.
n aco r es
am us
■
!'vk- .; L�., r�i:.i��.. ��`"r C i.�;�;u�i ti.Jr.7%��+�.'!
� ' 'r .7i= Lhr3,"3R ,�1f�� IV 3i3STRf�$
���. cJ� tF�� t�f�v, st�� e� t€
,�;�+�rvr ����rac���, u�rt s�z7a
{�s6Ci; �16-30CCi
� �
��� r�� Ar�Accr��-r�� ����,�� r�,����€� a w�
4�
�� ��� � ���� n���
p�LpTp�ry ������� ���� ��5,
!" GI��i I 9"[J. ..� �.�.•�-A-.....=�w m.w's�La�.
ADUR��'u�'a.-.\�_C�� \�-- i
'i
�
f1P�'ROV�:� �'t�� ��"� - —
�U�,��Gi' i� F€�L� €�SP��Tla`�aPJ. C}er�=�?�1�i-��
nFi 1iii�'�=.0 g�id �~ ��C°� !,�, 3°�t(? d�iay�i.i,�ar..+�i2
1 l.
r �'
��
.
Volume 1 of 1
Conformed Set
August 13, 2009
•
♦
n a co e s
Project Information:
Site Address:
16D6 R Avenue
Anacortes WA 98221
Property Owner:
Port of Anacortes
P.O. Box 297
Anacortes, WA 98221
A Ipp icant:
Northwest Career 8 Technical Academy Executive Board
c!o La Conner School Dlstrict
P.O. Box 2103
La Conner, WA 98257
Legal Description:
Lot 1 of Shorf Plat #ANA-98-003 AF#9902170072 Located in NW 114
Section 19, Township 35, Range 02
Proiect Data:
Skagit County Parcel No.:
Jurisdiction:
Zoning Comp Plan:
Building Code:
Proposed Use:
Lot Area:
Total Parcel Area:
Proposed Developed Area:
Proposed Building Area:
Proposed Utilities:
Wa[er, Sewer, Refuse Service:
Electricty:
Natural Gas:
Telephone:
VICINITY MAP
P32910 350219-0-005-0001
City of Anacortes
CM1 Zone (Commercial Marine District 1)
2006 International Building Code (IBC)
Educational - Secondary Vocations / Technical
5.94 Acres (258,746 sf)
3.68 Acres (161,706 s�
Approximately 62% of Total Parcel Area
Main Building =16,331 sf
Storage Building (�etached) =1,858 sf
Total Proposed Building Area =18,189 sf
Cily of Anacotes
Puget Sound Energy
Cascade Natural Gas
Verizon
General Notes:
1. SEESHEETAD.OFORMASTERKEYABBREVIATIONLISTSBYALPHABETAND
BY DIVISIONS.
2. CONSTRUCTION OF THIS PROJECT SHALL BE W COMPLIANCE WITH ALL
APPLICABLE CODES, ORDINANCES, AND REGULATIONS OF THE GOVERNING
JURISDICTION.
3. THE DRAWINGS AND SPECIFICATIONS: THESE �ETAILS COVER THE
FURNISHING AN� INSTALLATION OF ALL MATERIALS AND WORK AS CALLED
FOR ON THE DRAWINGS AND/OR THE SPECIFICATIONS WHICH ARE BOUND
SEPARATELY AND ARE PART OF THIS CONTRACT. IT SHALL BE THE
RESPONSIBILITY OF EACH CONTRACTOR TO CHECK WITH THE
ARCHITECTURAL AND ALL OTHER CONTRACT DOCUMENTS BEFORE THE
INSTALLATION OF THEIR WORK. ANY DISCREPANCIES SHALL BE BROUGHT
TO THE ARCHITECT'S ATTENTION BY NOTIFICATION FOR CLARIFICATION.
ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS
SHALL BE CORRECTED BYTHE CONTRACTORAT THE CONTRACTORS OWN
EXPENSE AND AT NO EXPENSE TO THE OWNER, ARCHITECT OR ENGINEER.
4. ABBREVIATION: THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH
ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT
INTENDED TO BE COMPLETE OR REPRESENTATIVE OF ALL CONDITIONS
AND MATERIALS USED ON THIS PROJECT. THEARCHITECT WILL DEFINE
THE INTENT OF ANY IN QUESTION.
5. SCHEDULE AND RECEIVE APPROVAL FROM GOVERNING JURISDICTION FOR
ALL UTILITY INTERRUPTIONS A MINIMUM OF ONE WEEK (7 DAYS) IN
ADVANCE OF NEEDED DATE.
6. PROVIDE BLOCKING BEHIND ALL WALL MOUNTED ACCESSORIES
7. ALL PENETRATIONS OF FIRE RESISTIVE WALLS SHALL BE PROTECTED BY
MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO
UNDERWRITERS LABORATORIES' LISTINGS FOR THROUGH PENETRATION
FIRE STOP SYSTEM. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING
DETAILS OF EACH PENETRATION WHICH SHOW COMPLIANCE TO THE U.L.
LISTING TO THE ARCHITECT AND SUCH DRAWINGS SHALL BE AVAILABLE TO
THE SUPERVISING INSPECTOR.
8. DO NOT SCALE DRAWINGS.
9. QUESTIONS DUE TO ANY APPARENT CONFLICT WITHIN THE DOCUMENTS
SHOULD BE BROUGHT TO THE ARCHITECT'S ATTENTION IN TIME TO BE
CLARIFIE� 8Y AODENDUM. ANY APPARENT CONFLICT NOT SO CLARIFIED IS
SUBJECT SOLEY TO INTERPRETATION BY THE ARCHITECT.
� •
Project Team:
Owner:
Northwesi Career & Technical Arademy Executive Board
Chris Borgen, Macortes School District
Laurel Browning, Burlington-Edison School District
Barbara Hawkings, Concrete School District
Dc Tim Bruce, La Conner School District
Dr. Carl Bruner, Mount Vemon School Distnct
Mark Venn, Sedro-Woolley School District
Dr. Gary Tollefson, Skagit Valley College
Owner Representative:
Bryan G. Young, P.C. Architects and Planners
PO Box 552
Anacortes, WA 98221
360.420.9420
Bryan G. Young
byarch@verizon.net
Architect:
Hutteball & Oremus Architecture, Inc.
4010 Lake Washington Blvd. NE,
Suite 320
Kirkland, WA 98033
425.828.8948
Civil Engineer.
Northwest Datum 8 Design, Inc.
2209 Monica Drive
Maunt Vernon, WA 98273
36D.424.4865
Structural Enpineer:
Watson Structural Engineering, LLC
1062 NE Redwing Drive
Oak harbor, WA 98277
360.544.8574
Mechanical Engineer.
Hargis Engineers
6D0 Sfewart Streef, Suite 1000
Seattle, WA 98101
206.448.337
Eledrical EnAineer:
Travis Fitzmaurice Engineers
1200 Westiake Avenue North,
Suite 810. Seattle, WA 98109
206285.7228
Acoustical Enqineer:
ssA Acoustics
222 Etruria Street, Suite 100
Seattle, WA 98109
206.839.0819
Landscape:
Cascade Design Collaborative
911 Western Ave, Suite 210
Seattle, WA88401
206.628.9133
Cost Estimator:
The Robinson Company
101 Stewart Street, Suite 925
Seattle, WA 98101
206.441.8872
.
Contact:
Kevin Oremus, Principal-in-Charge
koremus@hoaroh.com
Kim Fong, Project Mgr.
kfonq@hoarch.com
Contact:
Douglas Schwind, P.E.
doug@nwdd.com
Contact:
Hayden Watson, P.E.
haydenwse@msn.com
Contact:
Vern Enns, P.E.
veme(�Dhargis.biz
�D
Contact:
Mike Fitzmaurice, P.E.
mi ke(c�travisf tzmaurice.com
Contact:
Bill Stewart
bi II(@ssaacoustics.com
Contact:
Kas Kinkeatl
kas(�cascadedesigncol lab.co m
Jennifer Mundee
jennifer@cascaded es igncol la b.com
Contact:
Sharon Kennedy
skennedy(airobinson-co.com
Index of Drawings:
Volume 1 of 1
� ��
General Information
G0.0 Project Information Sheet & Index of Drawings
G0.2 Code Analysis Plan
Landscape
L0.0 Tree Protection
L0.1 Soil Plan
L1.0 Layout Plan
L2.0 Irrigation Plan
L2.1 Irrigation Plan
L3.0 Planting Plan & Schedule
L3.1 Planting Details & Notes
Civil
C1 CoverSheet
C2 Existing Conditions & TESC Plan (North)
C3 E�cisting Conditions & TESC Plan (South)
C4 Site Dimensional and Layout Plan (Norfh)
CS Site Dimensional and Layout Plan (South)
C6 Storm Drainage and Grading Plan (North)
C7 Storm Drainage and Grading Plan (South)
C8 Saniiary Sewer and Water Plan (North)
C9 Sanitary Sewer and Water Plan (South)
C10 Construction �etails
C11 Construction Details
C12 Construction Details
C13 Construction Details
C14 Constmction Details
C15 WaterConstructionDetails
C16 Anacortes Specifcations
C17 Striping and Channelization
Architectural
A0.0 General Legend & Keylink Abbreviation
A1.1 Site Plan
A1.2 Enlarged Partial Site Plan
A1.3 Site Details
A1.4 Site Details
A1.5 Site Detials
A1.6 Storage Building Enlarged Plans, Elevations & Details
A2.0 Wall Type �etails
A2.1 Dimension Plan
A22 Glerestory Dimension Plan
A3.1 Floor Plan
A32 Equipment Plan
A3.3 Concrete Finish and Control Joint Floor Plan
A4.1 Reflected Ceiling Plan
A4.2 Ceiling Details and RPC Schedule
A5.1 Roof Plan
A5.2 Roof Details
A5.3 Roof Details
A5.4 Roof Details
A6.1 E�erior Building Elevations
A62 E�erior Building Elevations and Canopy Elevations
A6.3 Canopy Sections and Details
A6.4 Exterior Details
A7.1 Building Sections
A7.2 Building Sections
A7.3 Building Sections & Wall Penetrations Details
A8.1 WaIlSections
A8.2 WaIlSections
A8.3 Wall Sections
A8.4 WaIlSections
A8.5 Wall Sections
A9.1 Enlarged Restroom Plan & Details / Utility Column Details
A10.1 Interior Elevations
A10.2 Interior Elevations
A10.3 Interior Elevations
A10.4 Interior Elevations
A10.5 Interior Elevations
A10.6 Interior Elevations
A10.7 Interior Elevations
A11.1 Door, Storefront and Relite Frame Typesl Details
A112 Door, Storefront and Relite Frame Types! Details
A11.3 Hollow Mehal Frame Details
A11.4 Aluminum Storefront and Curtain Wall Details
A11.5 Aluminum Storefront Details
A11.6 Aluminum Storefront Details
Al2.1 Signage Coordination Plan
Structural
S-0.11 General Structural Notes
5-0.12 General Structural Notes
S-021 Typical Details
S-022 Typical Details
S-023 Typical Details
5-1.11 Foundation Plan
S-1.12 Slab on Grade Plan
S-121 Roof Framing Plan
S- Pa ial Ro ramin a
-123 - oad' g ia ram �
- .2 De esignation � e plift
S-1.31 Storage Building Foundation I Roof Plan
52.11 Framing Elevafions
S-221 Bailding Sectians
S-222 Building Sections
S-3.11 Foundation Details
S-3.12 Foundation Details
5-321 Steel Framing Details
S- 2 Steel Framin Detail
- Stee ramin eta' 2
5-3.31 MU Details
S3.41 CFMF Details
S-3.42 CFMF Details
5-3.51 C eSu orked a{+�f et�ils
3. able Supporte Canopy Detai s 1
Mechanical
M0.1 Mechanical Legend
M0.2 Mechanical Abbreviations & Notes
M0.3 Mechanical Schedules
M0.4 Mechanical Schedules
M0.5 Mechanical Schedules
M1.1 Foundation Plumbing Plan
M2.1 Plumbing Plan
M2.2 Enlarged Plumbing Plan
M3.1 HVAC Plan
M4.1 HVAC Piping Plan - Alternate 1 Bid
M4.2 Site HVAC Piping Plan -Alternate 1 Bid
M4.3 Enlarged HVAC Piping Plan & Mechaniral Details -Alternate 1 Bid
M4.4 System Water Piping Schematic & Details -Aliernate 1 Bid
M4.5 Mechanical Schedules - Alternate 1 Bid
M5.1 Fire Protection Plan
M6.1 Roof Plan
M7.1 Mechanical Elevations
M72 Mechanical Sedions
M8.1 Mechanical Details
M82 Mechanical Details
M8.3 Mechanical Details
M8.4 Mechanical �etails
Electrical
E1.D Legend
E1.1 Site Plan - Electrical
E2.1 First Floor Plan Lighting
E22 Roof Plan Lighting
E3.1 First Floor Plan Power
E32 Roof Plan PowedComm
E4.1 First Floor Plan Comm
E4.3 Details
E4.4 Details
E5.1 First Floor Plan Signal
E6.1 Power One-Line & Riser Diagrams
E7.1 Lighting Fixture Schedule
E72 Panel Schedules
E7.3 Panel Schedules
E7.4 Panel Schedules
E7.5 Panel Schedules
ry
�
Hutteball
& (.�re 'mus
4010 Lake Washiog[on Blvd. NE, Suite 320
Kirkland, WA98033
p 425 828 8948 f 425 828 9067
REGISTERED
ARCHITECT
NeGI 708v
OF WASHINGTON
Northwest
Career &
Technical
%�C1t�@171y
1 sos � �V�11U@
AnaCOrte�, 98221
ANACORTES CAMPUS
Date: 07/13/2009
Project Na. 0806
DraWn: BS
��, 1 ADDENDUM 1 - 7129/2009
� 2 ADDENDUM 2- 8106l2009
CONFORMED
BID SET
Project
Information
Sheet &
Index of
Drawings
Sheet No.
�oeo
N
O
�
0
0
N
�
v
�
r
0
6+
3
�
�
N
a
6
c
Q
v
�
0
v
�
c
�
-
o�
�I
PLANNING CRITERIA
Address: 1606 R Avenue, Anacortes, WA 98221
Skagit County Parcel No.: P32910 35Q219-005-0001
Zoning/Comp Plan: CM1 Zone (Commercial Marine District 1j
Use: Educational - Secondary VocationallTechnical
Lot Area: Total Parcel Area = 258,746 square feet (5.94 acres).
Proposed developed area leased by NCTA - approximately 161,706 square feet (3.71
acres).
Gross Building Area: Main Building 16,331 sf
Storaqe Building 1,858 sf
Total Proposed Building Area 18,189 sf
Floor Area Ratio (FAR) AMC 17.22.070 - Maximum density/floor area ratio: 0.5 FAR, increased to a max. of 1.0 by
meeting criteria of 17.22.070 (A-C).
Proposed Development Area 161,706 sf
Proposed Buildinq Area 18,189 sf
Proposed FAR w/o increases 18,189 / 161,706 = 0.11 < 0.5 OK
Maximum Land Coverage: AMC 17.22.080 - Maximum land coverage of 50%
Proposed DevelopmentArea 161,706 sf
Proposed Building Area 18,189 sf
Proposed FAR w(o increases 18,189 / 161,706 = 0.11 < 0.5 OK
Parking: AMC 17.46.010 (i) Commercial parking is a conditional use in all zones.
17.46.020 Spaces Required:
Assembly Room - 1Q spaces per 1,000 nsf: 2,030 sf = 21 required spaces
Office/Conf. - 4 spaces per 1,000 nsf: 919 sf = 4 required spaces
Educational Classroom/Lab Space: Not identified.
Parking Space Assumption: Normal on-site parking demand for the proposed facility
based on designed program requirements and enrollment projections for future growth
is estimated to be 22 spaces.
Total estimated on-site parking required for facility in full use: 21+4+22 = 47 spaces.
Total on-site parking spaces proposed = 100 spaces.
Compact Stalls: AMC 17.46.010 Q) - One-third (33%j of required parking may be far compact stalls.
Standard Stalls (9'x18') 72 stalis
Compact Stalls (8'x16') 24 stalls
ADA Stalls (9'x98') 4 stalls
Total Stalls Provided 100 stalls
Percentage of compact stalls: 24/ 100 = 24% < 33% OK
Bike Racks: AMC 17.46.020 - One bike rack for every five parking stalls.
Based on the requirement for 47 stalls serving the proposed facility: 47 /5 = 10 bikes.
Five (5) bike racks accomodating 10 bikes is proposed.
Maximum Building Height: AMC 77.22.090 - Basic allowable height limit shall be twenty feet. Height may be increased
by ten feet if the building incorporates a sloped roof having a pitch of at least 4:12 but not
more than 12:12, and the ridge of the roof is perpendicular to "R°' Avenue so that views of
Fidalgo Bay are maintained. Only the portions of a building incorporating such a sloping
roof shall qualify for the ten-foot increase.
Proposed building incorporates a 4:12 pitched roof perpendicular to "R" Avenue to
increase the height limit for that portion of the building to thirty-feet. Remainder of the
building is twenty feet or less (excluding rooftop mechanical units as allowed).
Minimum Setbacks: No Minimum to property line. Twenty feet from right-of-way.
Landscaping: AMC 17.41.020 General Site Landscaping:
17.41.020 (D) - Trees along street frontages will be planted at an average of 30' apart .
17.41.020 (D,2) - Planting strips may be reduced to a minimum of 10' in CM1 Zone.
17.41.020 (G) - Minimum Gross Site Area to be Landscaped in CM1 Zoning: 15%
Proposed Development Area 161,706 sf
Proposed Landscape Areas
Rain Garden 4,320 sf
Planting Bed 14,240 sf
Meadow 28,900 sf
Parking Lot Planting Bed 3,300 sf
Buffer 9,965 sf
Total Proposed Landscape Areas: 60,725 sf
Percentage Landscape Area Provided: 60,725 / 161,706 = 38°/a > 15% OK
Parking Lot Landscaping: AMC 17.41.030(B) - Parking areas with 20 or more spaces shall constitute at least five
percent (5%) of the parking area to be landscaped.
Proposed Parking Area 38,458 sf
Required Parking Lot Landscaping 38,458 x 5°/o = 1,923 sf
Percentage Parking Lot landscaping Provided: 4,550 / 38,458 = 0.12 > 0.5 OK
AMC 17.41.030(C) - Minimum Width and Length: Planting areas shall have a minimum
average width of ten feet and shall be the same length as the parking stall.
AMC 17.41.030(E) - Tree Requirements: A minimum of one tree shall be required for each
one hundred fifty square feet.
Required Landscape Area 1,923 sf
Required Number of Trees 1,923/ 150 = 12.8
Pro osed number of Trees 29 > 13 OK
D���RR�D SII�MITTA�S: THE FOLLOWING DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED
UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE CITY OF ANACORTES
BUILDING OFFICIALS:
• AUTOMATIC FIRE SUPPRESSION SYSTEMS - SEE SECTION 21 10 00 FOR REQUIREMENTS.
SUBMIT TO ARCHITECT FOR REVIEW PRIOF2 TO REVIEW BY THE CITY OF ANACORTES.
• CFMF, STEEL JOISTS AND WIRE ROPE ASSEMBLIES - SEE 5-0.11 FOR REQUIREMENTS. SUBMIT
TO ARCHITECT FOR REVIEW PRIOR TO REVIEW BY THE CITY OF ANACORTES.
. DUST COLLECTION SYSTEM - SEE SECTION 23 41 05 FOR REQUIREMENTS. SUBMIT TO
ARCHITECT FOR REVIEW PRIOR TO REVIEW BY THE CITY OF ANAGORTES.
. PAINT SPRAY BOOTH - SEE SEC710N 23 33 00 FOR REQUIREMENTS. SUBMIT TO ARCHITEGT FOR
REVIEW PRIOR 70 REVIEW BY THE CITY OF ANACORTES.
*' REFER TO TECHNICAL SPECIFICATIONS FOR OTHER SUBMITTALS 8� REQUIREMENTS. � /�-/ -
�z � � _ m�p�
��° '_ _ 1J
f OUTLINE OF ROOF
� '� 'L':- .�' � � OVERHANG AT ENTRY
30'-8"
I. 15'-8"
184 LF OF
BUILDING
FRONTAGE
�--------�-------�
L-7--- I
3
� X x-x-x � �
I � _ _ I
� �
I I ' '1
�_____ L _ - ��
�- I
� � I
I STOR4178UILDING �� �.OVE96ANG�.�
I 3� I ��.. .�. ��
-�- �--- � ' �
15'-4"
37'-10"
u
� 590 LF OF BUILDING .
� �7 i. ;
, � � � �., -
ois� .,�;- ; � � J , � h
ro' ��- ��-,�c?r�� �c ����
149 K � I!�tG _ � 't5
� 151 t�`_ � `
r -
34' 2 [ _ _ � qq ��� � �
`1�-�J
COMPOSITE LAB
1649
50l33
-_--
� OFFICE
�_ _ � . � � L�.-�-� �� R -- 2�4
� � I' ' j A2 l j� iaora
I 1 � 1 � 2
I ' 1 r 1` -� T`� l � 1
I .
� I` -- I I"B IMAGINARY , � �`� 1
I 3H � I I I PROPERN LINE , ` � �� �1`
-I-- � � �` L MECHANICAL LAB �`
�- _J - - - - _ - _ - _ - - _ � � L 1972 1�
� 50l40 ��
BUILDING B I � r--
,,858 Sa. FT. r , S
� �
� '
�I � ---� ��
/ BUILDING B BUILDING A ` � ,
� '- - - - AC�°55
\ / ��� 54
BUILDING A Nso
16,331 SQ. FT.
FIRST FLOOR CODE PLAN
1 1
�1 �
1
1
i
�
roRnc
iss
NSO
SCALE: 1/16" = 1'-0"
BUILDING CODE CRITERIA
BUILDING A
Occupancy Classification: Group E (Educational)
Type of Construction: One-story, Type IIB w/ automatic sprinkler system per 903.3.1
Building Areas:
Main Building (Portion Aj 16,331 SF
Overhangs (Portion A) 3,031 SF
Total (Bldg. A) 19,362 SF
ALLOWABLE AREA BUILDING A; (Actual SF = 19,362 s�
Allowable Area (Aa)Per Story per Table 503: Tabular Area Per Floor (At) 14,500 SF
Area Increase for Is (See below) 43,500 SF
Allowable Area Per Floor 58,000 SF
Area Increase due automatic sprinkler system (Sec. 506.1):
Aa = At +(At x Is )= 14,500 +(14,500 x 3) = 43,500 SF
OCCUPANCY SEPARATIONS
No Occupaccy Separations Required
BUILDING B
Occupancy Classification: Group U (Utility)
Type of Construction: One-story, Type IIB
Building Areas:
Storage Building (Bldg. B) 1,858 SF
Overhangs (Bldg. B) 961 SF
Total (Bldg. B) 2,819 SF
ALLOWABLE BUILDING B; (Actural SF = 2,819 s�
Allowable Area (Aa)Per Story per Table 503: Tabular Area Per Floor (At) 8,500 SF
Allowable Area Per Floor 8;500 SF
OCCUPANCY SEPARATIONS
No Occupaccy Separations Required
ECRESS R�QUIR�M�NiS (IBC CHAPi�R 1�)
Egress Width (Table 1005.1) Other: 0.15 inches per occupant
Number of Exits (Tables 50 or less occupants: 1 exit
1015.1 and 1019.1) 51-500 occupants: 2 exits
501-1000 occupants: 3 exits
Greater than 1000 occupants: 4 exits
Arrangement of Exits Where two exits are required, the exits doors shall be
placed a distance apart equal to not less than one-third of
the length of the maximum overall diagonal dimension of
the area to be served (Sec. 1015.2.1 exception 2)
Travel Distance 250 feet in buildings with sprinkler systems (Table 1016,1)
Corridor/Hallway Rating No rating required for buildings with sprinkler system
(Table 1017.1)
Exit Doors Minimum Width: 32" clear opening. (Section 7008.7.1)
Maximum Width: 48" leaf. (Section 1008.1.1)
Dead End Limit 20 feet for corridors. (Section 1017.3) Shall not be limited
in length where the length is less then 2.5 times the least
width.
FIRE RESISTIVE REQUIREMENTS
Structural Frame Not Rated
Exterior Bearing Walls Not Rated
Interior Bearing Walls Not Rated
Exterior Nonbearing Walls Not Rated
Interior Nonbearing Walls Not Rated
Floors Construction Not Rated
Roof Construction Not Rated
Exterior Wall openings Unlimited Area
Storage Room Walls (Over 100 SF) Smoke Rated Partition
Hallway Walls Not Rated
Interior Finishes Hallways Class C
Rooms and enclosed spaces Class C
��� �
�L____, L_---
_: �
�= �I� inRD-I ti- -�-1 � - - -
� ' ;�CG x 0.15 35 �" �` 1
;a� pRavi��o �: r1 ' ° �
_; �� , 8 �a`� � !f��: OFFICE I
- _ 1 � �. / � 192 r
15� _ 100/2 r
MAI N
ENTRY
750
7/108
_____�
STUDENT
ENTRY
874
���zs
o��=�
WOODSUPPORT
722
50l15
MDF 11
7y V
PAINT 800TH N50
487
15W10 ELEC.
"' t � SO
� NSO
FARTHEST POINT
RROM EXIT
�T��� � OY-`F
_J �
� EXIT�'JV7DT'� ;:
� 23� t`lCC x 0 ia" 3,5
� 7t'F'R'GV���P' '�.
�� �;,
r� i ,h:`
OUTLINE OF ROOF
OVERHANG AT ENTRY
BOYS+
-s- � 1
�oK�P , ,,
{ 23
1 NS s
t ! ,
�
� 1 _.
35
CODE FLDOR PLAN DRAWINGISYMBOL LEGEND
�--Room Name Distance measured in feet
OFFICE
FloorArea ������------�---��
112 Exit access travel distance:
100l2.�,,_Occupant Load 250' max w/sprinklers
�Occupant Load Factor
(NSO = Not Simultaneously Occupied) Indicates starting point for exit access
travel distance
Smoke Partition Construction Indicates point along common path of travel
-x - c�-- at which two distinct exit paths are available
(distance equal to or less than 75')
Indicates direction of travel to exit door
NORTH
OCCUPANT LOAD FACTORS AND EXIT REQUIREMENT3 (IBC TABLE 1U04.1.2)
Use: Occupant Load Factor:
Classrooms 20 SF (net)/occupant
Assembly 7 SF (net)/occupant Chairs
15 SF (net)/occupant Tables/Chairs
Business Areas/Offices 100 SF (gross)/occupant
Vocational (Laboratories) 50 SF (net)/occupant
Conference/LoungelWait 15 SF/occupant
Mechanical 300 SF (gross)/occupant
Storage 300 SF (gross)/occupant
'LUMBING FIXTURE REQUIREMENTS (WAC TABLE 2902.7)
)CCUPANT LOAD
Group E Occupancy
Net Area = 9,417 SF = 100 SF/Occ = 94 occupants, assume 50% for each gender (47 EA)
StafF Requirements: 94 Students = 20 = 5 Staff Members
Group A Occupancy
Net Area = 2,030 SF = 30 SF/Occ = 68 occupants, assume 50% for each gender (34 EA)
;EQUIRED FIXTURES
Female Male
Educational (Group E)
Water Closets (student) 2(1 per 30 Students) 2(1 per 40 Students)
Water Closets (staff) 1(1:1-15 staff) 1(1:1-15 staff)
Lavatories 2(1 per {2} WC) 2(1 per (2) WC)
Assembly (Group A-3)
Water Closets 2(2:26-75 occupants) 2(2:26-75 occupants)
Lavatories 1(1 per(2) WC) 1(1 per(2) WC)
Total Required 5 WC + 3 LAV 5 WC + 3 LAV
Drinking Fountains: Z(1:150 + 1 per add'I 500)
IXTURES PROIVIDED IN DESIGN
Female WC �
Female Lavatory 3
Male WC �
Male Urinal 3 (Urinals substituted 1:1 for up to 75% of required WC)
Male Lavatory 2
Drinking Fountains 2
M
Hutteball
&OremuS
C4010 Lake Washington Blvd NE, Suite 320
Kirkland, WA 98033
p 425 828 8948 f 425 828 9067
IREGIS'ERED
ARCHITECT
� iv� �oao
'j%,�r�
, s. ram�s
OF WASHI;�GTON
Northwest
Career &
TeChi�tC1�
ACat1ef11y
1606 R Avenue
Anacortes, 98221
ANACORTES CAMPUS
Date: 07/13/2009
Project Na. 0806
DraWn: KO
BUILDING PERMIT
�RE-SUBMITTAL - 8/13/2009
�
CONFORMED
BID SEi
Code
Analysis
Plan
Sheet No.
�0��