Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-2011-0380 - FIRE ALARM
GAT C3 _y City of Anacortes Permit#: BLD-2011-0380 904 6th Street Issue date: 11101/2011 '`"■� +' P.O.Box 547 Expire date: 04/29/2013 <ip' CQ Anacortes, WA 98221-0547 }- (360) 293-1901 ,4'O ro,. Job Address: 1400 4TH ST Permit Type: Fire Alarm Permit ANACORTES WA 98221 Project: APN: P55673 P55679 P55366 P31513 P31514 P31515 P31516 P31517 P31518 Remarks: Extend existing fire alarm sytem to boat house building. Owner: TRIDENT SEAFOOD CORP Contractor: COMMERCIAL ALARM&DETECTION Address: PO BOX 17599 Address: 17199 BENNETT RD SEATTLE WA 98127-1269 MOUNT VERNON WA 98273-9789 Phone: (360)293-3133 Phone: (360)848-9093 License#: General Information: Fees: Building Valuation 5648 Building Permit Fee 101.25 Plan Review Fee 65.81 State Building Code Fee 4.50 Total Calculated: 171.56 Deposits/Receipts: 0.00 Total Due: 171.56 m t4 cy ►•• CO e+ O CA 1 +o v1 m l� q O 0 A co CO r (A t. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IIJ o CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. LA HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALA PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR o NOT, THE GRANTING A PER ES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LA EGU ING C NSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. v? i SIGNATURE OF OWNER OR AUTH I D AGENT ISSUED BY FIRE SYSTEM ACCESSORY Model 5495 ` 011, Distributed Power Module In an emergency, you need maximum power. The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor@,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-446-6444. Model 5495 • Independent trouble relay Distributed Power Module • AC loss delay option shuts off power The 5495 is a 6 amp notification power to non-essential high-current expander that provides its own AC accessories like magnetic door power connection, battery charging holders circuit, and backup battery for use with • Built-in synchronization for fire and security controls such as the appliances from System Silent Knight Model 5208 Fire Control Sensor®,Gentex®,AMSECO®, /Communicator.The 5495 is the cost Wheelock and Faraday effective solution for powering notification appliances required by the Stand alone operation Americans with Disabilities Act(ADA). • Lightweight design adds to ease of The 5495 has built-in ANSI cadence installation and reduces shipping pattern,which can upgrade older costs control panels that lack cadence • Operates with most polarized, UL capability. Listed notification devices Features • UL 864& 1481 listed ` • UL Listed for 6 amps of notification • CSFM approved power Model 5495 • Power supply's advanced switch ANSI Cadence pattern output Distributed Power Module mode design reduces damaging capability built-in heat and manages power up to 50% Connection to Local Fire Control more efficiently than other systems The 5495 may be connected to a local 4.7kQ end-of-line resistors provided. • Dip switches allow for easy fire control which utilizes Class A or Since the 5495 draws very little power reconfiguration Class B type notification circuits from the control, it is possible to • 24 VDC filtered output voltage operating between 9 and 32 VDC.The connect one 5495 to each notification control panel's notification circuit is circuit on the control panel and still • Four power-limited notification outputs;2 Class A or 4 Class B,or 1 connected to one of the inputs on the provide full supervision of the Class A and 2 Class B 5495.The control panel's notification notification circuits all the way back to circuit end-of-line resistor is also the control panel. • Additional continuous auxiliary output connected across two terminals on the 5495,which provides supervision SILENT • 3 amps per output circuit between the 5495 and the fire control • 2 inputs; 2 Class B or 2 Class A panel. Polarized audible and/or visual KNIGHT • Ground fault detector/indicator notification devices are then connected on to the 5495 signal circuits using the by Honeywell FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging • Low AC power Auxiliary capacity: 33.0 AH • Low battery condition power circuit: 1 Ambient temp.: 320 to 120° F • Earth ground fault Notification 00 to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25"W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on : Green condition on the host control signal output circuit: 3.0 6.0 amps total circuits to which it is connected. the p ( p ) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 kQ EOL Output alternative to using the notification resistor required troubles(1-4): Yellow circuit trouble. on each Class B Approvals: Electrical Specification circuit UL: 864 & 1481 AC input: 120 VAC at_2 amps No. of inputs 2 NFPA: 72 Output: 24 VDC at 6 amps Input CSFM configuration: 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed iginal Signal Circuit Output Signal 2 power input Module 5495 Signat 3 (Optional) Signal 4 120 VAG Aux.Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT`;,; This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350395 Rev B, 12/05 subject to change without notice. For more information,contact Silent Knight by Hone trell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone:(800)328-0103, Fax:(763)493-6475. �33 SYS TEM SENS OR 5600 SeriesMechanical Heat Detectors 6R System Sensor's 5600 series mechanical heat detectors offer o low-cost means for property protection against fire,and for non-life-safety installations where smoke detectors are inappropriate. s Features Multiple configurations.The 5600 series offers a full-line of Multiple configurations for installations: configurations to accommodate a broad range of applications.Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- --Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135'F or 194'F ratings. fixed temperature/rate-of--rise(ROR)activation.The ROR element of Plain housing for residential installations(Model 5601 P) the fixed/ROR models is restorable to accommodate field-testing. • Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, A broad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —35-and 4-Octagonal when used with a square to round plaster ring.The reversible —4-square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings ,H u` <S> MEA LISTED APPROVED approved s211 301600e 199-03-E 7270-zo9:w Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall berated for activation at either 135'F(57C)or 194'F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature,approximately 157(8.3'C)per minute.The detector shall include a reversible mounting bracket for mounting to 31,4-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14--22A1NG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.the rate-of-rise element of corbination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall nclude an external collector that shall drop upon activation to identify the unit:in alarm. Ra Maximum Installation Temperature 5601 P,5603,5621,and 562.3:1007(.38"C) 5602,5604,5622,and 5624:150'F(65.6'C) Operating Humidity Range 5 to 95%RH non condensing Dimensions with mounting bracket Diameter 4,57 inches(I 1.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P 5603,5621,and 562.3:135"F(57'C) 5602,5604,5622,and 5624:194'F(90"C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 15"F(8.3'Q rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal bark box Single gang back box 4-inch square back box with a square to round plaster ring Operating Voltage 1 Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/0.3A 250VDC/0.1A Input Terminals 14-22 AWG ;x ra W71 —71 0 o a a o I i 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information 5601 P Single None 135°F(57'C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90oC) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135'F(57'C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194'F(90oC) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57'C) Fixed Temperature/Rate-of-Rise `0 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90'C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135'F(`7'C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90oC) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. �12SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 Proosctsp,df.alo ,,b)'t ro.h-.ha—y wit—t t Mot systemsenso rnrn for SENSOR Phone:800-SENSOR2•Fax:630-377-649:i ",r•P,t,,r °m.'° t .'test. ;a•;;�snee• AGS-GiSJG211lG6•N57f INTELLIKNIGHT O. Model SD500-ANM Addressable Notification Module The cost effective way to expand the IntelliKnight's notification circuits. The SD500-ANM gives you the flexibility to add notification circuits wherever you need them. The SD500-ANM is a supervised addressable notification device that provides you with additional notification circuits on the IntelliKnight SLC loop. Up to 127 SD500-ANM modules can be used on an SLC loop. The SD500-ANM provides a reverse polarity Class A or Class B notification appliance circuit with an aux power input. Each SD500-ANM is provided power from a separate power supply and is controlled and supervised by the main panel. Power can be provided near the signaling appliance to reduce the wire gauge requirements or can come from a main power supply and be controlled separately by the individual notification modules. The SD500-ANM can produce all 16 of the notification patterns available on the FACR Model SD500-ANM Features Addressable Notification O Module Class A(Style Z) or Class B (Style Y) Notification Circuit. The SD500-ANM is an Addressable • Flexible programming—choose Notification Module for use with the the cadence pattern (twelveF, 's IntelliKnight fire alarm control panel. The SD500-ANM provides a standard &four user-defined). ,/ • PollingLED visible through cover single class A or B circuit that is g z controlled by the IntelliKnight's plate. Signaling Line Circuit. Power for • Adds up to 127 independent the circuit is provided to the output circuits on each SLC Model SD500-ANM SD500-ANM module from a loop. Approvals separate power supply, making it • Supervised auxiliary power easy to power remote devices. source input. • UL listed, complies with NFPA 72 The notification circuit, remote • Completely supervised. • CSFM power and communication to the • MEA 429-92-E, Vol. 9 SD500-ANM are supervised by the IntelliKnight control panel. Specifications Operation Operating Voltage: 24 VDC Compatible Control Panels Each notification module is SLC Current: .55 mA • 5820XL programmed with a unique SLC Aux.Power Current: • 5808 loop address. When an event that Alarm: 56 mA • 5700 controls the notification module Standby: 6 mA occurs, the notification switches its Notification built-in relay g feedin power from Appliance Current: 2 Amp Max. the auxiliary power input to the Ambient Temperature: 320F to 120OF notification appliance. (0°C to 49°C) Mounting: 4-square electrical box. SKEW KNIGHT A, by H %%, -. ACCESSORY Model SD500-ANM Addressable Notification Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable notification modules, Silent Knight SD500-ANM. The modules shall be UL listed compatible with a Silent Knight IntelliKnight fire alarm control panel. The notification module must provide one Class A(Style Z) or Class B (Style Y) notification output with one auxiliary power input. The notification module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The notification module must provide an LED that is visible from the outside of the cover plate. The notification output must be fully programmable for such applications as are required by the installation. FRONT VIEW H ; a f 2 4-VS" yjo 'e � c ? F I£ 4-7 0Vim Model SD500-ANM Addressable Notification Module � E This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all FORM#350220 Rev.B,2/07 specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight Copyright©2007 Silent Knight by HWOWAO 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Phone: (800)328-0103, Fax: (763)493-6475. INTELLIKNIGHT O. SD500-PS and SD500-PSDA Addressable Pull-Station IntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated contacts. Addressable Pull • Reflective label makes it easier Station to locate in low light The SD500-PS is a single action Operation addressable fire pull station, and The SD500-PS/PSDA single action the SD500--PSDA is a dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. l of the Americans with Disabilities The SD500-PS/PSDA includes a ACT(ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32°F to 120°F • UL Listed communicating with the loop. The (o°C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS-SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) • Surface mount back box Specifications available Operating Voltage: 24VDC SILENT Standby Current: .55mA • Terminals- accept up to 14 Alarm Current: .55mA KNIGHT gauge wire A b"'v w ACCESSORYINTELLIKNIGHT SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACn w HN 1,Pv '�i N r e Alp.1 ' l Wiring a Mounting to Optional Mounting to Single g p Gang Electrical Box Surface Mount Box E IL IN J IJ i .. ... ..... _ Vw Q SD500-PSDA 3 d \ � S A € a Installing SD500-LK Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350342, Rev.09/03 FAX: 763-493-6475 World Wide Web: http://www.siientknight.com Copyright©2003 Silent Knight SYSTEM II SENS OR Selectable Output ` Horns, Strobes, and v Horn/Strobes SpectrAlert®Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRAJert Features The SpectrAlert Advance series of notification appliances is Electrically compatible with existing SpectrAlert products designed to simplify installations,with features such as plug in Automatic selection of 12-or 24-volt operation at 15 and 15/75 designs,instant feedback messages to ensure correct installation of candela individual devices,and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. •Plug-in design Field selectable candela settings on wall and ceiling units:15,15/75, When installing Advance products,first attach a universal mounting 30,75,95,110,115,135,150,177,185 plate to a four-inch square,four-inch octagon or double-gang Same mounting plate for wall-and ceiling-mount units junction box.The two-wire mounting plate attaches to a single-gang Shorting spring on mounting plate for continuity check before junction box. installation Next,connect the notification appliance circuit wiring to the SEMS -Tamper resistant construction terminals on the mounting plate. Outdoor wall and ceiling products rated from—40°F to 1517 Design allows minimal intrusion into the back box Finally,attach the horn,strobe or horn/strobe to the mounting plate Horn rated at 88+dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the Rotary switch for horn tone and three volume selections mounting plate's terminals.The device will temporarily hold in place Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) with a catch until it is secured with a captured mounting screw. outdoor requirements Outdoor products NLMA 4X rated The SpectrAlert Advance series includes outdoor notification Compatible with MDL sync module appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or Agency Listings dry applications. SIGNALING 7125-1653186(indoaf stlabes) 1 X 7300-1653187(outdoorMEA 7123-1653:189(horn7strobesapproved chime/strobes) LISTED APPROVED 7135-1653:108(h...s,chimes) 54011 3023572 MEA452-05-E 55512 53593 SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1/2-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/s-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4"/,e x 4"/,e x 21/e-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature —40°F to 151°F(-40°C to 66°C) Humidity Range 1 Oro 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8-diameter x 2.5-high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x 5.0"W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.25-high(180 mm diameter x 57 mm high) Mall-mount weatherproof back box dimensions(SA- BB) 5.71 x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1-diameter x 2.0"high(180 mm diameter x 51 mm high) Wall-mount trim ring dissensions(TR-HS,TRW"HS) 5.71 x 4.812"W x 0.35D(146 mm L x 122 W mm x 9 D mm) Ceiling-mount trim ring dimensions(TRC-HS,TRC -HS) 6.9"diameter x 0.35 high(176 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-005 ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter=5-15116" F` Diameter=3-15116" C( ) a Height—2 inches, .. �.... t. including base Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350225 Rev C,.05/05 13,11" subject to change without notice. For more information,contact Silent Knight y Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone:(800)328-0103, Fax:(763)493-6475. ACCESSORYINTELLIKNIGHT Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment.And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into . H Analog/Addressable an electronic signal. Under normal Photoelectric Type conditions, the status LED blinks Smoke Detector approximately every 15 seconds, The SD505-APS is particularly indicating that the head is 1 �1 t suited to detecting dense smoke communicating with the loop. The w typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. q foam or other similar materials Features s which tend to smolder and produce large visible particles. . Low profile, 2 inches, including SD505-APS Smoke Detector base Specifications The detector features automatic • Simple and reliable addressing Operating voltage: 17-41 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: 55 mA the panel or remotely (using the Alarm: .55 mA • Built-in fire test feature WindowsTM based downloading . Simple detector calibration Ambient Temperature:32°F to 120°F software). testing through the control panel (0°C to 49°C) Operation or remotely through a Mounting: 4"Square, 4" The SD505-APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal-resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light . Field cleanable Air Velocity: 0-300 FPM from the pulsing light source. In the . UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505-6AB detector and light is reflected from . CSFM approved (Sold Separately) (6"Base) the smoke particles to the receiving pp SD505-4AB element. MEA approved (4" Base) • FM Approved SILENT KNIGHT[31 by Honeywell UL Current Draw Data 8-17.5 Volts 16--33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 1S 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 r 16-33 Volts 16-33 Volts DC Input 135 ISO 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela ratings must be reduced in accordance with this table. 1 8-17.5 16-33 24 Volt Nominal E .- 4 Volts Volts Reverberant Anechoic P Listed Candela Candela rating at-40"F Position osltlan Sound Pattern d6 13C FWR 13C FWR [?C FWR 19C FAR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 81 Coded Medium 78 78 85 85 90 90 97 98 150 150 9t Coded Low 75 75 81 81 88 85 96 92 177 177 t5ettings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 A05-0395-005 SpectrAlert Advance Dimensions �4.7" 2.5 6.8" Dia. 2.5" 5.6" m Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1" 7.1" N-2.25 10'2 Dia. 5.05- �2.231 Dia. I I ,(IAODo0O - 2.0" 5.98" 6.2" Null back box skirt Ceiling back box skirt Wail weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall Horn/Strobes Ceiling Horn/Strobes(contd.) P2R*t 2-wire Horn/Strobe,Standard cd*,Red PC4W 4-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P2RK*° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P2RHKn 2-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P2WH* 2-wire Horn/Strobe,High cd,White SCRK° Strobe,Standard cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red SCRHK° Strobe,Hiqh cd,Red,Outdoor P4RH* 4-wire Horn/Strobe,High cd,Red SCW*t Strobe,Standard cd,White P4RK° 4-wire Horn/Strobe,Standard cd,Red,Outdoor SCWH*t Strobe,High cd,White P4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor Horns P4W* 4-wire Horn/Strobe,Standard cd,White HR Horn,Red P4WH* 4-wire Horn/Strobe,High cd,White HRK° Horn,Red,Outdoor 'Mall Strobes HW Horn,White SR*t Strobe,Standard cd,Red Accessories SRH*t Strobe,High cd,Red BBS-2 Back Box Skirt,Wall,Red SRK° Strobe,Standard cd,Red,Outdoor BBSW-2 Back Box Skirt,Wall,White SRHK Strobe,High cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red SW* Strobe,Standard cd,White BBSCW-2 Back Box Skirt,Ceiling,White SWH* Strobe,High cd,White TR-HS Trim Ring,Wall,Red Ceiling Morn/Strobes TRW-HS Trim Ring,Wall White PC2R* 2-wire Horn/Strobe,Standard cd,Red TRC-HS Trim Ring,Ceiling,Red PC2RH* 2-wire Horn/Strobe,High cd,Red TRCW-HS Trim Ring,Ceiling,White PC2RK° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Notes: PC2RHK° 2-wire Horn/Strobe,High cd,Red,Outdoor *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g., PC2W*f 2-wire Horn/Strobe,Standard cd,White P2R-P. PC2WH*t 2-wire Horn/Strobe,High cd,White t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. PC4R 4 wire Horn/Strobe,Standard cd,Red t"Standard cd°refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 PC4RH 4-wire Horn/Strobe,High cd,Red candela settings. PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor All outdoor units ending in"K"include a weatherproof back box. PC4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor a Add"-R"to model number for weatherproof replacement device(no back box included). SYSTEM 112008 System Sensor. 1 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject ro<hange withoutnotce.usit systemsensoccom for current product information,including the later version of this data sheet. Phone:800-SENSOR2•Fax:630-377-6495 A05-0395-005.8/38•#2018 [� F I s 1y ems- 106 H SLC -.., Global Project Values: g 105 F Project Name:ITrident Boat House Standby Hours: 24 R a U' Project ID: 11-305 Alarm Mins: Z J EOL Prepared By: CDH Derating Factor: 1.2 Date: 10/24/2011 Voltage Drop Warning 110 CO z Threshold% : 10 a cal Z U J J Panel ID: 15495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps z Location: Trident boat House Volts: 24 VDC Max Panel Current: 6.0 Amps 0n z w� F H S Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standby Alarm & Type 1000 Ft. One-Way Ohms EOL /oDrop D7 NAC 1 N- SLc S 102 SLC SLC SLC SLC S 703 SLC SLC 110 S SLc07 SLc 5495 5495 Pwr Module 1 0.075 0.205 04 07 10 NAC#1 5495 Circuit 1 Cfg. 0.000 0.643 #16 Solid 4.02 200 1.61 19.37 5.07% 5495 9-- NAC 1 NAC 1 NAC 1 NAC 1 NAC 1 NAC 1 NAC 1 NAC#2 5495 Circuit 2 cfg- 0.000 0.445 #16 Solid 4.02 150 1.21 19.86 2.63% 110 NAC#3 5495 Circuit 3 cfg. 0.000 0.154 #16 Solid 4.02 50 0.40 20.34 0.30% 708 F Al NAC#4 5495 Circuit 4 cfg- 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% EO NAC 2 N 2 NAC 2 NAC 2 NAC 2 NAC 2 NpC p Nq NAG 2 NAC 2 JC Aux 5495 Aux Power Out cfg. 0,000 Q,QQQ #12 Solid 1.59 0.00 20.40 0.00°10SLC SLC SLC SLC SLC SLC SLC SLC SL SLC SLC SLC SLC SLC S S108 108 108 H 1 110 H10 Total Standby Current (Amps) 0.075 1.447 Total Alarm Current (Amps) 111 Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) € Total StandbyAH Required 1.800 0.121 Total Alarm AH Required Total Combined AH Required 1.92 Wire resistances are based upon an ambient temperature of 72 degrees F, 108 EOL Multiply By The Derating Factor 1.20 Because of the minimal difference between solid and stranded wire no differential a-- 108 108 -- J H H Minimum Battery AmpHours Required 2.30 was made. o Configure Circuits Print Page H H H EL ` SYSTEM BATTERY CALCULATIONS & VOLTAGE DROP Fire Alarm System Expansion Scale 1 8"1'0A Boat House 0 ,f f �fi � DESIGN CRITERIA- DESIGNED PER IFC-2009 EDITION ❑ ,t. ','. INSTALLED PER NFPA 72-2010 EDITION „`..� INSTALLED PER NFPA 70-2008 EDITION SCOPE OF WORK _,,��y a .� �/�{✓./, '� µ=_ . COMMERCIAL ALARM&DETECTION (CAD)WILL EXPAND THE EXISTING D. 14 lm ADDRESSABLE FIRE ALARM SYSTEM FOR PARTIAL AUTOMATIC FIRE 2 t� 0�^r� DETECTION, MANUAL ALARM,AND BUILDING EVACUATION IN THE r;re% EXISTING BOAT HOUSE BUILDING. Key Plan Scale NIF I RE ALA M I CABLE CODES DEVICE LEGEND REVISIONS CONTRACT WITH: ODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL Mar�ir 4&URl_I7 TYPE MODEL CANDELA MOUNTING r�Tv" NO oArt- ur REASON FOR REVISION -- COMMERCIAL ALARM & DETECTION, INC. " " Trident Seafoods IOC INDICATING DEVICE CIRCUIT 1-2 C 18 AWG FPLR ��OR C-0YRINAnpI OPEN AND RACEWAY s SILENT KNIGHT PHOTOELECTRIC SMOKE DETECTOR SD505-AP5 4 «- 17199 BENNETT ROAR NAC NOTIFICATION APPLIANCE CIRCUIT 1-2 C 6 AWG FPLR OPEN OR COYBINATON OPEN ANO RACEWAY N SYSTEM SENSOR HEAT DETECTOR 5Y5-56D0 12 MT VERNON, WA 98273 _—.._-... _.-_-.--- --- AUX AUXIWARY APPLIANCE CIRCUIT 1-4 C 16 AWG FPLR OPEN OR CONBINAIION OPEN ANO RACEWAY SYSTEM SENSOR HORNSTROBE _ SYS-P2R SHOWN PER DEUCE g 1 400 4th St LICENSE #COMMEA194BLO SLC SIGNALING LINE CIRCUIT 1-4/C #18 AWG FPLR OPEN OR MONOON OPEN AND RACEWAY 0 - SILENT KNIGHT MANUAL PULL sTA-noN- SD500-PS � 4 —_— Anacortes, Wa 98221 PHONE: (360) B48-1533 FAX- (360) 848-1072 51LENT KNIGHT AUXiLLIARY POWER SUPPLY SK-5495 1 i PROJECT MANAGER : Jeff Johnson j TridentSeafoods _ -- _ - -- ------- __.� 400 th � _....- _.-- -__._.....__..— _-_._�.. PHONE : 360-299-7022 I 4 St _ - - -- -. - Anacortes, Wa 98221 --.----------....-- — SUPERINTENDENT : AUTHORITIES HAVING JURISDICTION : PHONE : Dept Of L&I FAX : DRAWN BY CHECKED BY DATE SHEET. JOB NO - ---- - - -- --- ---- ------- -- — --- CDH 10/24/11 1 OF 1 11-305 L� o r r STURDY ENGIlVEERING C O R P O R A T I O N Civil • Structural Date: October 6, 2009 Job No. 1547-01-GS h; r LATERAL & GRAVITY ANALYSIS p ' for Trident Seafood Corp L Vestibule Addition 1400 4th Avenue ., Anacortes, Washington Building Code 2006 IBC Seismic Design Category: D SS Fa Wind: 85 MPH Exp'C' =uw Roof Snow/ Roof Dead: 25/12-psf Floor Live/ Floor Dead: N/A h Required Soil Bearing: 1,500-psf h _ Note: Sturdy Engineering Corporation does not assume any liability for elements that are not specifically addressed in this analysis. ,This report is valid only for the specific project shown above and herein. Any sheets, which are not bound to the. original complete set are not valid and shall not be used (excluding authorized, stamped addendum). Contents: Page r . G, Structural Plans S1 - S5 i Wind Loading 1 - 5 ^' Truss Analysis 6 - 11 Frame Analysis 12 -16 y' Roll-Up Door(Reference Only) 17 - 19 .r; 7168 San Juan Hill Ln. • Anacortes, Washington 98221 • Phone: (360)29972511 • Fax: (360) 299-2698 E-mail: sturdy@ sturdyengineering.com 7—r"J -5e—a-p —i— JOB 7168 San Juan Hill La. Aaacortes,WA 98221 SHEET NO. Bus:(360)299-2511 Of Fax:(360)299-2698 CALCULATED BY DATE 10 STURDY ENGINEERING CHECKED BY DATE C 0 R P 0 R A T 1 0 N Civil - Structural SCALE .......... ..................... .................. .................. .......... ......................................... ...... ........... ...................................... ............P1 AOL41 ........... .......... .......... ........... .......... ............ ................. ................................................ ..............V -% ......................i I - -o----- i.............. ...................... .................. .................... ..................... . .................. .... .... ..... .... .... ..... .... .................. ............. � b ..... ..... .... ..... ........... ...................... ..................... ....... ........ ........... .......... .......... .......... ........... .............. .......... .A, ...........4 .................... .......... .. ........... .................. ......... ......................................... ...................... .......... .......... ...................... ................... ...................... ......... ......................................... ............ .................................... .. ...................................................... .......... .......... ..................... .......... .................. ............... ........... ........... .......... .......... . ...... .................... ................... ........... ................... ....... .......... ................... .......................... .......... ..................... ........... ............................... ..................... .................. ........... ........... ...................... ......... ...........A.41 .................... ........ ........... ................... ..................... .......................................... ............................................................................ .......... ................ ........... ................ .......... ................... .......................... .......................... ......... ................................ .......... ............. .............. .......... .......... ................... ...................... .................................. .......... .......... ..................... ....11..................... .......... .......................................... ........... ................. ............... ... ....... .......... ........... ........... ........................ ....... .... . ....... ...... ...................... ....................................... .... .......... .............................. ........... ....... ....... .......... ................. .......... ........................ .......... 1 14 ............................ ............. ........................ .......... MA 4 .......... ........... ..........I....................... .......... ....... .......................... .... ........... .......... ...................................... .......... ..................... !......_..i......... ......................z...................... ..........t.......... ........... . .. ....... .. ... ............... .......... ................ .......... — ........................................... .......... ................................ . .... . .... .... ................ .......... ... .......... ............................................. ..................... ........... ..................... ..................... .......... . ..... . ....... ........... ......... .......... .......... ...................... .......... ......................... .......... ..... ......................�-!p ........ ......... .......... ..................... .................... .......... ........... .......... .......... ........... ................................ ..........I............................................ ..... .......... ............... ........... ... ........... .......... . ..........i............w .......... .......................... ................... ....... ........... ........... .................... .......... ........... ....... .................... .......... .......... ............................... ...................................................... ................................ .......... ............................................................................ ........... .......... I...................................................... ...... . ....... .......... .......... ........... ............... ............ ........... ............................... .....................1.......... .......... .... ............. t ............... ........... .......... ..................... ... ................ V to ...... . ....... .......... ............................................ ............... .......... ........ .......... .......... ..........4...........j................................. .............. .......... ...................... .................................................... .......... ........... ..... ............ ....... .......... ............................ ............ ..... .......... ......................... ...................... ........................................ .......... .......... .......... ........... ....... ............... .......... . ............................................ ..................... ... ................................. ............. ................... ..... ...... ........... ..................... ........... .......... ................................. ........... ..................... .......... ........ ..... . ......... .................. .......... .......... .......... .............. ........................- .................. ..... ..................... .................... ........... .; :.......... ................................... .......... ...................... .............. ..................... ...................... ........ ..................... ..... .......... ..................................... .......... ..................... ...................... .................... ............................. .........a............................... t.......... ........................................................ ................................... ............. ................................ .................................................. .................................................... ...........IL ........... ..................... ...................................................... ........... .................................. ...................... .......... .......... ................................. ........... .......... .......... ...................... .......... .......... ............................... ..................... ... �oa - ANWALMv ,'w a=m=muu` ^"=""" '*^"«o/ umscr ur Bus:n^v`zv"'zn ""� / Fax:nmvz99'2wo CALCULATED BY ox,E S71IRDY ENGI NEERING------- ' -- CHECKED BY n^rs c o x p o n ^ r ' n m -'''' ~'~'' ~~`~' uoxLc -3- MECAWind Version 2 . 0 . 1 . 2 per ASCE 7-05 Developed by MECA Enterprises, Inc. Copyright 2009 www.mecaenterprises.com Date 10/2/2009 Project No. Company Name Sturdy Engineering Designed By GLS Address 7168 San Juan Hill Lane Description Trident Seafood Vestibule City Anacortes Customer Name Trident Seafoods State WA Proj Location Anacortes, WA File Location: C:\Program Files\MECAWind\Default.wnd Detailed Wind Load Design(Method 2) -per ASCE 7-05 • Basic Wind Speed(V) = 85.00 mph Structure Type = Building Structural Category = II Exposure Category = C Natural Frequency = 1.00 Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor 0.85 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 An = 0.15 Bm = 0.65 Cc = 0.20 1 - 500.00 ft Epsilon = 0.20 Zmin 15.00 ft Slope of Roof = 1.94 : 12 Slope of Roof(Theta) = 9.20 Deg Ht: Mean Roof Ht = 17.35 ft Type of Roof =_Gabled RHt: Ridge Ht = 18.20 ft Eht: Eave Height = 16.50 ft t OH: Roof Overhang at Eave= 0.50 ft Roof Area 266.00 ftA 2 Bldg Length Along Ridge = 25.00 ft Bldg Width Across Ridge= 20.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc* (33/Zm)^0.167 = 0.23 Lzm: 1* (Zm/33)^Epsilon = 427.06 ft Q: (1/ (1+0.63* ( (B+Ht)/Lzm)"0.63) ) �0.5 = 0.94 Gust2: 0.925* ( (1+1.7*lzm*3.4*Q)/ (1+1.7*3.4*lzm) ) 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi GCPi Internal Pressure Coefficient +/-0.18 Figure 6-6 External Pressure Coefficients Cp - Loads on Main Wind-Force Resisting Systems(Method 2) -4- heta h L z Id B B Kh: 2.01* (Ht/Zg) A (2/Alpha) = 0.88 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256* (V) A2*I*Kh*Kht*Kd = 13.76 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 266.00 ft"2 Reduction Factor based on Roof Area = 0.90 MWFRS-Wall Pressures Perpendicular to Ridge Wall Cp +GCpi(psf) -GCpi(psf) Leeward Walls -0.50 -8.33 -3.37 Side Walls -0.70 -10.66 -5.71 Elev Kz Kzt qz ----Windward Wall---- Total Shear Moment ft psf +Gcpi -Gcpi +/-Gcpi Kip K-ft ------------------------------------------------------------------------------ 18.20 0.88 1.00 13.90 6.98 11.93 15.30 0.08 0.01 18.00 0.88 1.00 13.87 6.95 11.91 15.28 0.84 0.78 16.00 0.86 1.00 13.53 6.72 11.68 15.05 1.59 2.37 14.00 0.85 1.00 13.35 6.60 11.55 14.92 2.34 4.71 12.00 0.85 1.00 13.35 6.60 11.55 14.92 3.09 7.80 10.00 0.85 1.00 13.35 6.60 11.55 14.92 3.83 11.63 8.00 0.85 1.00 13.35 6.60 11.55 14.92 4.58 16.21 6.00 0.85 1.00 13.35 6.60 11.55 14.92 5.32 21.53 4.00 0.85 1.00 13.35 6.60 11.55 14.92 6.07 27.60 2.00 0.85 1.00 13.35 6.60 11.55 14.92 6.82 34.41 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg Roof - Dist from Windward Edge Cp +GCpi(psf) -GCpi(psf) --------------------------------- ------ ---------- ---------- 0.0 ft to 8.7 ft -1.07 -15.04 -10.08 8.7 ft to 17.4 ft -0.77 -11.48 -6.53 17.4 ft to 20.0 ft -0.63 -9.85 -4.89 f -5- i MWFRS-Wall Pressures Parallel to Ridge Wall Cp +GCpi(psf) -Gcpi(psf) --------------- ------ ---------- ---------- Leeward Walls -0.45 -7.74 -2.79 Side Walls -0.70 -10.66 -5.71 Elev Kz Kzt qz ----Windward Wall---- Total Shear Moment ft psf +Gcpi -OCpi +/-Gcpi Kip K-ft ------------------------------------------------------------------------------ 18.20 0.88 1.00 13.90 6.98 11.93 14.72 0.06 0.01 18.00 0.88 1.00 13.87 6.95 11.91 14.69 0.65 0.60 16.00 0.86 1.00 13.53 6.72 11.68 14.46 1.23 1.82 14.00 0.85 1.00 13.35 6.60 11.55 14.34 1.80 3.62 12.00 0.85 1.00 13.35 6.60 11.55 14.34 2.37 6.00 10.00 0.85 1.00 13.35 6.60 11.55 14.34 2.95 8.94 8.00 0.85 1.00 13.35 6.60 11.55 14.34 3.52 12.46 6.00 0.85 1.00 13.35 6.60 11.55 14.34 4.09 16.55 4.00 0.85 1.00 13.35 6.60 11.55 14.34 4.67 21.22 2.00 0.85 1.00 13.35 6.60 11.55 14.34 5.24 26.46 Note: 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg Roof - Dist from Windward Edge Cp +Gcpi(psf) -GCpi(psf) --------------------------------- ------ ---------- ---------- 0.0 ft to 8.7 ft -0.99 -14.00 -9.05 8.7 ft to 17.4 ft -0.84 -12.26 -7.30 17.4 ft to 25.0 ft -0.56 -9.07 -4.12 -6- m m m h LO O O O C � C !0 O O I, 0 O N O 'O a 0 2 0 o c Z r Z m c 0 O� O O )O V¢U� COf 3 C M cli o yy F- InOOW i I / ro 0 0 0 w ro v 0 u q v b 4J O U N N �p O $4 CO a _o co 4J o u .r O b o O N 41 / V] m F- 1.1 � > N ro u U O d A o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �+ A U .-I oo • 0000 N 14 • 0 0 0 0 0 0 0 0 0 o O N 0 000000In In Inlnln • In0 C: 'E W lD %D '-I H r-I H r•I '•I N N N O 0 H m •rl / I I I I I I I I I a1 rl I I b) >. R W •o 00 x X 0 + 3 3 H cn u O + + + a 54 r"I >4 >4 DH >+ a+ >+ >+ >4 >+ N >+ DC D4D4D4 �+DC DC w ro A A A A A A A A A A A A A A A A + + w t` Om x r In �C In Ln 0 V.0 -1 ri M If1 lD N H M v m w v 0 m w E r O Gl x W x W r u i.) b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • + U + + U + + U U o 41 O o 00000000000000 O l4 3 $4 3 14 34 + q u] z zzzzzzzzzzzzzzz �/� + o � + o p + 0 � p G4 41 U) A * 0 q * 0 A * O O + O H ro ko x fA w x ca ko x W f+ Ea x 134 4)v v b O o + '1 o + �tl 0 + �1 q o to q +-� x V.i m .— .• q m m A m A w m q o N C7 O N q o 4) q y q () 0 Mm4J CU O %D m 0W m 0w m 0 + m 0 �q m 41 0UbW E . N 0 dH bi bi ~ m U r1 q r 1 q q r1 q q rl q C H rr 1a •• O c 0 •r1 O •rl O •r1 0 -4 >r 1�.) r-II A/ O O p L 7 O t�l 0 DC O N 0 O '0 -4 v) •ra J u ro A u roA + u mA I U 0A u CDro w u _ m U q -H ► O •r�i +=� a u O u ' ° O A e ° a c oa A 4.) — ., rfl 1 , roroa� w "p CU ,.) 00 4J00 + 4, 00 1 4J00 4 7 w n d u u Q Id u u A 3 0 u u 0 z 0 u u Q 0 C m on O ro >4xx >4 O � 0 0 a > uaw° z a° AAAAAav� vlv� mv� g Jw w w w W -B- 0 o i D + i+ + I 3 Ln DC DC M W Ln Ln r r + O o N o O o o r r N + o + + + + o o (p to o + o 0 0 0 + +4. 6 • o td rd o o O Id ro w w o o (d (d o 44 0 0 tn v) N P4 Ln o in Ln o O (O N ri 14 U� Li O -1 + + ri H U + + + O + o o + + k4 r. G4 G4 fs4 o o 49 F= + W + + + + [ti 44 N + o o + +49 ' 0 0 0 0 o 0 + x + + + + x x + o o + + 1+ is is Ln N Ln Ln Ln Ln Ln Ln r + r r r r r r r R DC DC 0 0 + o o DC o o >C o DC o R R + i + + U1 + + + R + R + R + R + t o 0 o $� o N a o 0 0 0 0 + * a + # a + a * w * v) * b wro + ro + cd + ro + (d + (d + (d a r a a s a s a s a s a s a s oN + a + a + a + a + a + a 3 Ln 3 Ln 3 in 3 Ln 3 tn 3 in o r - - r r r r r r r * o U) Ln u) Ln Ln in Ln w41 o r o r o r o r o r o r o r o N. + u o + u o + u o + u o + u o + u o + u o + u a u W + u ►+ + �4 + �4 + + + k + ►a + ►r + o sa + O 0 Go O 0 N o 0 Dw o N O f=, 0 :3 W O O N o Dw * N O * O + * O + * 0 + * O + * O + * O + * O + * O + x O + * O am = 0 m xaUn xavA xatn xam xaw = F4W x w xxtn Ln + Ln + Ln + Ln + Ln + in + Ln + in + + + rai gra9 Aral Ara! Ara► qra! grar Aral A is A + ar O ra O N O N O 0 O W O w O N •• O w a W V) co N t". OJ C. N C 0 tr' 0 ['. N 93 N q W G'. Gl N + to O + to O t to 0 + W O + rA O + m 0 + W O + N 0 + W 0 t W (d ri rd H (a ra b •4 b •4 b H Id ri fd •4 b •r♦ (d AU 410U +-) AU 410u NAU 4.1Au 4.+ AU uAU NAU 4J0U Ol t71 •• t71 r. to tT r to r •• tT to q to v •• to q 9 0 q q -H q r~ ri 0 , q -H 0 q •,i A -H qO r � Hu H � H q q � Hr 41 E4 ii ii E q41 441 •i � i 4J u0 ,) a i� a � o410 k04J0 0w0 X04J aJa uro ou rtA U (dA U rdA + U tdA U tdA + U rdA i U rdA + U rtA U NA U (dA q�i ►�7 R qOi 0 -14 k 9 � q -H $4 3 0 -H k � q q0i P ., � Cl -H $4 --� rr -14 14 a 0 -H 93 k E g Q v E q Q tp O A A " �S O E q L] " �C O@ q A �C O E -) ADC 0 8 q Q DC 0 E � Q 0 DC 0 E �A v•0 E J 0 0 Sa �1 O O JJ OE O r1 + O O S+ JJ O O + 0 0 i 4J 0 0 + 4J O O 1 4J O O fa u 0 0 UUA �I � UUAt/] rtUUA .-l3 �dUU q �.73 rtUUA3 �UUA3 �atlUUA u13 rtaUUAv] 3 tadUUA �I �UU W W W W W W W W W -9- 0 O V v v w 0 —.♦ N CO CO O CO O tD O In .. 0 V N rl Q W N M dl ri H W W OD .0 7 ro vvmmmmvvm ll w OH f- ,r m In M M M M m to M M M M W I m 11 I I I I I I I M I ri I M N N N N N N N N N �.'• ID lD lD lD 1D VD tD tD tD J-t Li O O J-I f'. O O CTI ri ri rl H rl ri rI rl ri a) •ri 0 O y •rl O O -r-1 m m to m m m m m m m O O m O O m O O O O O O O O O W W N O O In N m In O O to W O O W O O Q 1D tD M M M M to 1D M O O >4 >4 S 3 + + ,N o O �^y: ru kro4 a1 wwMMMMw 01M ro ro ro ro }.. O O ro Ift Ill M M M M In to M u u I J-1 J-1 L In In jy I I I I I I I I I z H r-1 (n z r1 -4 A\ m N N N N N N N N N GJ 0 ^' GJ Gl V/ >G ri ri w wtD wb w w w w ,^ N A Q W N a Q U + I r-1 H H H H H 7-4 H H r-1 v, m I I N m I I + n + w m m m m m m m m m N ro a s ro a s (Q b v O 0 0 0 0 0 0 0 0 0 U N U $ 0 0 3o u (n O 000MMMOOM U mm mm Q + * 14 + i1 Si �-, b tD M M M M W W M L aJ + + L J-1 + + N w N o + rl. o .�C O w + 4-0 -I w w x + m x + m U bbbbbbbbb LL m W= (n m xx Q + + N WWGJWNWNGI0 w + + a� + + 00 a Q01a m at~ G � a >~ >~ a s X x AQ X x QQ X « a aI aI t11 CT C11 01 aJ dl a1 x m x m ( 4J r1 •rf •r1 •rl •H •,i -ri -rl -el L'. C) F' NC) t0 m m m m m m m m m O + m O t m y W m m W m N W N W S-I N ri 14 N ri •rl ro -r1 ro m AAAAQAQQA W oo W 00 L EAU ro � A 0 C V. -r0 tn i L G Ja rl w ri N to W N M ri C EE m x C FE m x C O •rl O •rl d) 000000000 c c C •.l 1J •r.l JJ A O O O O O O O O O 5 E O a.l 0 DC O tJ :3 DC L E x x x x x x 0 U tdA + U roA I D1m C Em [Q mO 4 tJ _ 0 -r, 3 0 •rl 3 E xxmaoxx WU H rlr, /N� H N Am O qiJ A OA aJA tbw HHwwN v ri -ri N E 0 DC •0 E C - ?C N o 0 0 o aD ao t� t` rn E E E E K K J-1 O O t J-1 O O 1 -ri M fn N N O 00 OD O W 0 W W W Qm (dUUQa IdUUAa a o, o� � m � �om � o N w $ W W A o 0 0 0 0 0 0 0 0 W £ W £ £ -10- rn 0 0 N co t1� 0 O N co 41 •� O $4 U 4) p a 0 (1) $4 a F- 41 >•l 0 a m 0, O1 0 Ill ul V) N u1 N N N N N N N N r N [- M r ao r r r rl r w N N N N N N tD In Ill In 0l u1 en N N '-I r-I H M r-I O 01 ON Ol 01 01 01 v VI ri VI tD dl ri M W V' b N H tO 01 Ot Ot Ol 01 N ON lD r-I ri ri 4) ri M Ol 01 44 H 01 01 VI W VI VI H ri ri HtD ID 01 01 OD OD M ul M M 0 0 0 rl OD r HH ri ri W r tO tD VI VI 0 ri r•I { JJ IL1 ul M 14 00 OD M 14 M M O O tD 1O 00 W N N rl ri ul V; U; U1 OD O M M 40 OD O O Ill In 1l1 ul O O M M M M Id V• VI " VI VI V VI dl W V• 00 00 M M r r OD o VI VI VI VI M M M M 01 (1 10 to VI w VI eM 0 V V' VI V w VI 'W y) H ri H H ri H N N N N N N tO tD N N N N N N N N tD %D tD 10 N N r r N N N N .-I H r1 ri rl ri N N W DCA o000000 0000000lnln oolnlnoolnulo 0 00000000 1 I I i I I 1 1 q [ari o0000000000000rr lnlnrrullnrrullno0000000 94 044 0 VI • 0Ill 0In• 0O 0O 0O 0 0000 1 • M• • • 0000Il 1 1 zI z r1 r. N • 7zzzz 4J u0 OOO O MM MM M MMMMMMM MM I M M O O O O v w 1n In M M 1 1 M M 1 1 M M 1 1 w dl W rix + D4 >4 W W A Q A q EO Id R R + + W a P+ GI —1 R R + ?+ ! C DI >I DC ?C >C DC DC >C x ri R ! R + + I 1 + + I I G) Id rt y q 4.) 41 a s q1 V1 R R R R R R R R ltl rt A JJ H ri + + + + 4J � a Ma W Ql 0 a a a k M W H ----------------- U y q q + + + + a a A a a a s W. 0 0 W W (tl C) Gl A A cCy >4 x I I W W W W + + + + + + + + + + + + 4J (d q q D4 D4 1 1 fD + + a a r r r r a a a a a a a a a a a a r-I JJ 1 1 + + a a • + + + + + + + + + + + + 4) ri a a R R U N z R R >4 >4 >4 o 0 0 0 3 3 3 3 3 3 3 3 3 3 3 3 A >4 x x >4 x x + + "'-"'--•'-•'---'--'-—-'--•-—-'-———— I A SC x M x x x + + 1 I N + + R R R R J•J In In u1 ul ul ul N 0 0 In ul to u1 0 In ul a I + + I I + + R R R R J�J U r r x x x x 41 t- r lr lr r r l- r lr r r r r c- r r $4 $4 a R R R R r � x x x x JJ p, a'' + + + + r-I 000000 o 0000000000 ,7A to m3333 + + + + -I 3 3 3 3 A 1 + + + + + + + + + + + + + + + + + + + + + + + + o 0 3 3 3 3 m 0 410 0 a G4 Gd D4 D. W G. D4 G4 44 k. N kl N w G+ [74 k. 41 G4 G4 E14 G4 44 W + + + + + + A q q q q q q I + + + + + + + + + + + + + + + + + + + + + + + + A A m A 0 q I N N to tD tD t0 to 1D a w [f4 x x x pC x x x x x x x x x x x x x x x x x x x x tD t0 tD %0 tD tO a .r, w a) + + + + + + + + + + + + + + + + + + + + + + + + + + 8 OG o 0 0 0 0 o g A q A A A q A A A A q A A A q A A q A q A q A A A q A o 0 0 0 0 o A q 0 JJ cu N 4) r 4 r-I H rl H rl r•I r-I ri r-I ri r♦ ri ri ri ri rl r! ri ri ri ri r-I ri r l ri ri r-I H r l r-I ri ri H M M M M M M M M •.i O •d 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 F Z zO zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz -11- i o� 0 0 N CG O O O O U O N 7 H r H N N N N N ul N 01 01 v 1D 'i 10 w v ''I M '-I 1D 1D N 01 ON 01 01 01 1D M 'i 44 r-1 r I H 1D 1D m 01 Ill Ill w w O O M M m r O H 'q '-I H H w w w r . . . . . . . . . . . . . . . . . . . . . . . . . . f'1 N) O O l0 10 N N CD 00 Ul Ill 'I 'I 00 00 In V; M 14 00 00 Ill IA O O .0 co 00 (11 (n 00 00 r r I�r v q m m m M m Ol w w v v d� N N N N 10 10 N N N N N N N N 10 10 1p 10 N N r r N N N N fzlri >4 >4 I I Q Q Q Q + + DS DC a a I I I R R R R >4 >4 x � a a a a + + I I t t i I a ►7 U) En R R R R R R R R ro ro + + + + 4.l 4.) + + + + aaaaoaaxo� mrnmw w w w w + + + + + + + + + + + + i ro Q Q r r r r a a a a a a a a a a a a z + + + + t + + + + + + + 0 0 0 0 3 3 3 3 3 3 3 3 S 3 3 3 A QN >4 x >4 D4 co 4j Ifl ll1 I!1 Ln Ifl In Ln In In In Ill UI Ln Ul 1l1 in a I + + I I ro H r r r r r r r r r r r r r r r r a R R R R U go0000000oOOOOoOoaawto3[ 333 4 a w w w w w w w w w w w w w w w w w w w w w w w w 7 + + + + + + + + + + + + + + + t + + + + + + + + u, w w x x x x x x x x x x x x x x x x x x x x x x x x w + + + + + + + + + + + + + + + + + t + + + + + + + + x Q A Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q W r�l M M M M M r 1 M m M M m en M cM M M (n M (n m M M M M M 'd 00000000000000000000000000 0 00000000000000000000000000 -12— d �o _ N Nl N OOp 0.540! O O LO C � C l0 O O F4 CD 1 1% U� p O O N O a 0 i5£5'0 0 Z o v t m C9 c 0 aN- O Y O U O<L O V QUco rna�,y n > A N .1&3 C C f0 O W g W N> 7 T(G C N 4) Ol> 'i 7 jS A V) Iroo8w -13- i to 0 0 0 w ro d to ,3 a a� > v + •+ 3 3 -0 Ln Ln E r, r O O m o o CDU + + N W M n o o co 0 #iO rt O a _ P. w > U) tn e- 41 O + + U b o 0 0 4.) i G` w to m + + F 4J U + + O H q U - O o 0 W 7. O 0 o ao H a w co -1 a a . 1 i i Ln Ln a d A k X DC r DC r S W �+ 0 + i + 0 i o -14 3 3 R + u u + + N U + + O q 0) 0 k0 140 a O 71 $+ « o o a + a * ro „i Sa H i4 x �+SC DC * « + ro + ro w u ro q q q + + ro ro a s a s o ro u O Rw w w + a + a in H i 0 x 0 >4 0 3 Ln 3 Ln 0 m x r + ui i Ln r r x � a a+ E + m � Ln + -1 r k 0 wo .-4 o r o R + 0 •14 4) N rn E t` 0) x 0) x 0) 0) 0) 01 01 U a.) ra 0 0 + u + + U + + U U o + U O + U 3 o U 41 0 0 0 � o ►4 3 w 3 k ►+ + $4 + 14 + * ►4 t 0) tN z zz �/� + 0 0 + 0 0 + o a � w o 0 w0 9 ww p r. v) A 0 q * 0 q * O 0 + 0 + 0 + 0 w rl Wxtn Wxtn koxm +, to x � tn x � to x + W 044) W C Oo + a o + a 0 + 'm AOL1 grLa Ar LS Ao (a a + ro A m A m A m w m o m o m x m �� rl ro m +r q O 01 q O 0) �,• O 0) 0 0) f. 0) q 0 {. 0) () O W W 4.) (U 0 %o m 0 to m 0 ko to 0 + m 0 + m 0 + m O + m � WNC 4, � LoU a� 0U 4J (DU � qU s.) AU yq rq U a.10u •—+%o ro ro ro ro ro ro ro ro � a � 14 ri � rqa � 0am •du aar. a � a V aa a 0 � � °> nA D0i 4.) 4J � � � ��m + a ) � : 00 xO eO + 0 I u roA roA + UroA roA U roA + u roA u roA ro 3H $ � $ te $ H � 4-a - uJ V a w _ IN a . a . 0 i O 9Q 14C) — V —r 0xH v-4Ve VQx .,I a aau' O0 a roc: r+b O 0uuQ 0uugro000 % MUuqrtuug3MuuASuu 0 � AA ro O �, tv r > u0444 Z A as Jw w w 14 w w w -14- 0 O vN In In N C1 b b to m O ri In O CD J CO N N OD O vCD CO I N a b b In cob b In w C) A N N N b b N N b N 44 C1 A In 1 1 ri C1 CD l O CD O O N O O ri -rl O O N w �_ r•I r-I '�•1 m 00 w b H O 0 b O b O r•1 N ri t o b b HCO r, - -tCO H CO C1 1-I N CO CD C1 1 CO CO CD 1 C1 3 CD b w M A b b I b b • (°I r b L� W N N O O N N O O O N O r- w M N coo O 00 O N N N r r .•.•r1 O O O O O O O O O O O r r r N N ri N m O O 0 o o O N q w w 1•1 CD l- 1 v p, 0 0 0 0 0 0 0 0 0 N £ •r'i b b I 1 ri • • 1 1 0 • • 1 1 1 M I r•I 11 1 1r1 0 0 1 0 0 (h A 1, w r Ch 01 M 44 1 1 0 0 1 1 0 0 0 O _. O H M f, r` 0 0 0 0 0 0 .- CD w • CD •r1 0 0 0 0 0 0 0 O O O >•1 A • CD C1 N m N m O O 0 0 0 ri oo co Ln ON1 0N1 r�i t p1 O O O O O O O O O O O CD N r•1 O O O O O r-1 N CD A �. r•1 1 b In r b W b b b b H U r 1nrcDln M 0 r- ornN x A O r-I Ot C1 (d •rl H r-I O w N r•1 H w O 1` W k r� b C1 W to M M ri M M G1 N 1` 1` CD OD 1` a CD CD N ra O CO ri CV ui fd CD o -1 CD In r•4 CD b O • • b CD M N C1 C1 ri H C% w w N ra N w w ri N M CA r♦ 1 1 1 1 1 1 I 1 1 N I t 1 1 1 N q MC1m 41 q 000000 11 0 0000000000 p1 r•1r-Ira N -11 000000 N •ri 0000000 000 •r•1 m K x m • 00 • O m 0000 • 0000 m 0 0 0 W b b 0 4-1 b b Q) r•I Hr1 W CO O O ODO w 44 C� C; O O O o O O O O O H ri N O r•1 ri k 3 + 10 ro1 411 td td (a (d rd 4J J%.1.) 1 411 rt (d -a 0 ri r-I 11 4J j) 4J 41 ri 1-4 ri 41 4) r_ CD w 0 z a a a999 9 a a a A a a a Q Q E /N^' z a a a �. ri o, 01 41 GI x + x >4 m x W d1 X + }+ + x x U 1 r•1 H 14 r-1 Cl) m R 1! I + + + N m + !! R 7! + + ca A\ R + GJ k k k W D7 s! R >i 1! td R f! !1 a� b 000 u xx f/) u xx x So1Vi N £ 333 i1 333333 N 4J 33 3aa N k1 [4 O ri + + N k1 41 41 },� 1•1 N + + + 44 [a + O V O A A + + + + :3 + A q q + + x + to 'db 'd U— m to xxx x m xbb bxx Q + W y y N N • + + + + O + • + + Ao �a m a1o, a1 X x 0C, X a QQOOOAg000 X O + m 11 O) O) N i 1 M ri H w w ri I4 r I r 1 w ri M r 1 ri r1 w w E AA C 000G000y� C0000000000j C 0 UDU � 9uVm� vu-,I V. o gqmum mu H N �C 4J 000 E ."� u 0 A � `� £ O u u W H ^' H N N +•1 •I N N 1 1 ^^'' H r•1 r-1 �✓ H 4 v v v v— + - W O 11 q v O w O W r�i rl Q) >1 >r N N >4 >1 N N -r1 >' -- y! E a1 riO0 E !� N ? N > E AAAA KAAAA k E + 4- 0 0 1 -r{ w w fn O) 1T• £ 9 £ > m 44 44 W w 44 w 4a w W 4� 3 D1 u u q t~ 1n in 1n w yk� yk� kk $4 Q� D 1d 1d rt q O j1 G' ri ri C O O O N, r1 •rl •rl �.1 •rl .0 •r1 •rl •ri W W £ £ £ £ £ £ W £ £ £ £ £ £ £ £ £ £ -15- i rn 0 0 N M CM O (D O V O � � A I 4J q O 0 d) •rI 0 0 o a W O to LO O O N O 01 O 01 O O1 M 4-1 l0 01 01 O 01 Ln v O O1 M M V• M lD N In v O co M N W O CD . eM M co M Ifl V' lD 01 M O O 01 01 tD H In VI y r M O H ri M O O • • 1O H • • w r w VI . • • • O O O o • • OD M • • lD O1 >4 A dl V' O 0 • • o O O O r O • • l0 01 • • O O O 0 rI M V• V V' V' V• r • M 10 G4 r•I O O rI H 00 O w VI w in 10 .0 r 0 O M W • • OD O1 o O • • M M r O O M w 01 • r1 rl OD 01 • N N M M 01 01 00 O M M l0 4D rl H OD OD O 00 Ill Ul Vl lD O OD O 0 M M I I W 1O O 00 OD O I I U1 in I I O O C1 01 H r•I H H OD OD O OD rl ,•-I Ill Ifl rI rl 01 01 01 01 H rl O O O 00 r1 ri r1 H N N I I v V' " V' I I I I N N Ill Ill VI v N r Ill O 1 In con M U, rl O O Ill lCl r r aD M to rl 01 0 01 01 In In 01 In 01 u1 N N N r In In In 01 D7 (d X A 01 ao O Ot 01 01 01 ul 01 ul O O N N ri O vl ul aD aD D7 O O O sp 01 01 r r m O1 V 4J JJ G4 ri O 00 M O V V V VI O1 01 CO G1 N N O O1 rl rl rI rI O O rl 0 ri r-1 N N VI N • H r•I H -I OD (n • (n CV • in r • H 1D 40 r N 01 41 co 01 to r VI Ill rl 10 r 00 %D r 10 10 H O VI N r r r r O 0) 00 M N rl M N t0 OD co H O r r r r W W O Ol 00 00 N rl ri H M 01 00 01 N N N N r ko VI Ill M Ol r 00 1 H H I I 01 O1 N N N N I 1 r lD I I 01 01 I I I I CO O I I I I I I l0 1D I I OD O z a a v se x a a a all (d * * y rd u ri + + +CacoC se + 3a a� m (d RRRR w (d (d RRRR JJ + + q JJ aJ (d (d A 1J 4.) (d (d ri !r. N 1 H ri JJ 4.) I -4 ri JJ 4.) a + + a W � S4 >4 S•I r•I ri a N W S4 >4 >y >4 rI ri W xx w a A aaaa d, 0 A A 04 a a 0 w + + ye I + + + + A A >4 D4 1 I + + + + A q x A A + + a a a a a a I I + + a a a a a a I Cl) z R R + + + + a a R R + + + + a a DC DC DC >C 3353 >4 >4 >4 >4 5333 N x x + + I (d x PC x DC x x + + I I (d "�• DC DC DC k d1 O O W t t R R R R 1J IA l/l Ill UI t t I I + + R R R R 41 Ill Ill Ill Ill + t I O (d W W i r r r r Id r R R R R W W Ds rirrrr R R R R 0o u rrxxxx 4J O rrxxxx 4J N • + + + + ri g0000gg g � • + t + + rI Aoo00 O O V 4.) 0 0 3 3 3 3 al I + + + + + + + + o o S 3 3 3: W I + + + + + t + + E uu ri + + t + + + q aN wN w w w ww + + t t + + A P4 N 04 4, 4, 44 444, 44 A A A A A A I + + + + + + + + A A A A A A I + + + + + + + + W %D %DkDIOto %D 04 [1444xxxxxx xxlDlDl04DWW 44Pr4G4xxxxxxxx w Q + + + + + + + + + t + + t + t + t t + + x o 0 0 0 0 o g q q q q q q q q q q q O o 0 o O o q A A A q A q q A q q q H V A A S4 W H H H ri rI rI 11 H rI rI H H ri H H rI H H VI .0 d VI VI VI VI v v VI V v VI 0 v VI V VI 4J k'�j q R7 000000000000000000000000000000000000 K f0 •rI O o O o O o 0 0 0 0 0 o O o O o O o O O o o O O O O O O O O o O O o O O O W Z z zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz -16- Untitled Project VisualAnalysis 6.00 Report Company: Sturdy Engineering Corporation Engineer: Gary Sturdy Project File: Lateral frame Folder: C:\Documents and Settings\Gary Sturdy\My Documents\00-Active Project s\Trident Seaf000ds\ Steel Base Plate Design Design Parameters ----------------- Base Node: N001 Design Type = ASD Spacing to outer plate edge: Strong direction = 0.5000 in Weak direction = 2 in Spacing to column: Strong direction = 0 in Weak direction = 2 in Anchor ultimate tensile stress (Fu) = 65000 psi Concrete Pedestal f'c = 2500 psi Plate Fy = 36000 psi Base plate rests on leveling nuts (does not bear on pedestal) Gap between plate and pedestal = 1 in Column Section = W10xl9 d = 10.24 in bf = 4.009 in Design Results -------------- Plate Dimensions: Strong Width = 12 in weak Width = 6 in _ Thickness = 0.2500 in Pedestal Dimensions: Strong Width = 24 in Weak width = 12 in Anchors: Anchors are located at the following positions (strong coordinate, weak coordinate) , as measured from the center of the plate: (Units = in) (010) (010) Anchor Diameter = 0.6250 in Anchor Embedment Depth = 4 in Shear: A shear lug was required in the strong direction: Depth = 2 in Width = 1.250 in Thickness = 0.5000 in A shear lug was not required in the weak direction. -1-Fri Oct 02 12:58:55 2009 -19 D NXI PR DA H I G H P E R F O R M A N C E R O L L I N G D O O R Specifications: Subject to change ••• _ , T.M PREDADOOR® NXTT" Model:Rytecc'PredaDoor®Nor'M Door `` Standard Size: Up to 16 feet wide by 15 feet high. ITM Door Panel: Standard 32 ounce replaceable vinyl sections with wind ribs and full-width replaceable vision panel. Options include 2-ply or 3-ply Rilon, USDA compliant ��� MAW �.,� material,and screen material. Color options available. roakowc�m.. � x„ Side Frames. Fully bolt together anodized my - InL aluminum construction with two full- - _ _.w +.. ' ..._ m..� ..._.,a •A•' � an--tr!tD height brush seals in each column.Hidden `�"` raceway allows for additional wiring. Break Away: The Quick SetT"' tabs permit the wireless bottom bar to release in either - ----_---slirection_wrthout.--.damage--to---the--door. Standard dual cutoff switches shut off' motor when bottom bar is impacted. reversing e is standard. Pneumatic ev g edge �g Optional electric reversing edge is available for certain applications. Optional padded -�-- bottom bar is available. IF is Resetting System: After the door takes a hit, Tight Seal on All Sides Extended Battery Life NXT Quick-Set Repair the NCI' Quick-Set Repair System resets Edge-to-edge brush seal Automatic sleep modes Permits the operator to the bottom bar after user alignment. at the top of the door extend battery life by reset the door using the seals any gaps. Full- reducing consumption. System 3 controller after height brush seals inside Average 3-year battery aligning the bottom bar. Drive System: Three-phase,variable speed each side column seal with replacement indica- AC Drive provides soft acceleration and both sides of the door tor. deceleration. Independent opening and panel. closing speeds provide flexibility to accommodate any application. Wireless Safety System: Continuous Travel Speed:Opens at up to 50 inches per and uninterruptible signal eliminates second. need for coil cords on the bottom bar while maintaining safety and reducing maintenance. The control-reliable Electrical Controls:System 3 controller is system is self-contained on each door housed in a NEMA 4 rated enclosure with directional transmitters and .with factory set parameters. Self-diagnostic + features and atwo-line, receivers operating independently, 32-character LCD allowing the control box to be mounted One Cedar Parkway display in En fish, Spanish or French in a remote location. Jackson,WI 53037-0403 provide quid and straight forward Phone: 262-677-9046 installation and control adjustments. Fax: 262-677-2058 Warranty:Programmable inputs and outputs W ear limited warranty g P p tY� Two-year Toll Free: 888-GO-RYTEC accommodate special control requirements on materials and workmanship. Email: info@rytecdoors.com without the need for additional electrical components. Web: www.rytecdoors.com 0 Rytec Corporation LIT.EAZS - _ R DA OOR H I G H P E R F O R M A N C E R O L L I N G D O O R America's LeadingHigh-Spe ed Door Taken to the Next Level. Rytec has taken the PredaDoor",the industry's top selling high performance Fast - Opens at up to 50 inches per door,and added NCI'generation features to offer the most advanced direct second for improved traffic flow, drive roll door available the PredaDoor NXT. productivity and energy conservation. In addition to contoured side columns,the PredaDoor NCI'offers a tighter Safe - Full-width vision panel, two ` seal on all sides and an advanced wireless safety system. Like the original,it sets of thru-beam photo eyes and a is durable and can take a hit. The NX-f Quick Set TM repair system engages pneumatic reversing edge a r e through the System 3`' afteraligning the bottom bar. standard. Optional Ry-Beam TM light curtain is available. The PredaDoor NCI'offers high performance for interior and exterior applications where speed, low maintenance and dependability are critical. Takes a Hit and Resets - The NXT Plus, a two-year warranty makes it the best value in the business. Quick-Set repair system permits the operator to reset the door after aligning the bottom bar. Ry-Wi'" System - State-of-the-art -----— - _ ^_ - ----_W1 - ec n e reless-t -ology-eliminates eliminat s..tchy. --- — - —: need for a coil cord. Two-way O Way © communication and total frequency ` control ensure safety and eliminate a interference. g System 3®Controller - Using only three buttons,the door is easy to set i up, operate and maintain. Variable speed AC drive provides soft starting and stopping. Durable Fabric Panel - Standard replaceable vinyl panel sections .:: available in a variety of colors. - Optional 2-ply and 3-ply Rilon 7'M x available. i Full-Perimeter Seals - Brush seal at £ the top of the door. Two brushes in A each side column seal both sides of ' fn the panel. Vinyl loop along the floor completes a full-perimeter seal. PRE D NXI 1 j g ' r z5: rf rhl"`.✓V-N,�> r q�.a',+ �W� xY4 SF� .;e 3 ��,�Yj:"^y -�kEY 2 q �i Y�4 5 ✓'l� k Jf �ryg"� S bEdf>T3'� i f� ,Y " y�v .. , ' x"t✓r. 6m' ttt..�:.k Driving The.Dona Industry. sr u r u r+ AMR=3+cu..fa-..?.., W = �2 Z w N U � 0 w 2 0 Cl) -17- o 3 91 2 y 00 y �n W� z v> z m o o O v m (n 2 w tn Z !� V m oa.0❑❑ �+ pz 3r� �o w y 3 i W O tg zWa �s ^gym a O Z W 0 O 44 m Op � = CC Q z 2 ' H ao (� oU30om Q w0�`' zoom V Nw� zaw ~ d all V3 & ° a z ar00 ��,�, n� oFzaO �w (L, ZLUF WMoz 00p a o � z � � t i i> of � mog a� !+ oo z L) W �i $z0 ' y O Q Wa m cc Z z CL W MCl y 'was �a y = 0 ono o �0 V-)i0 `AI ~o rt � O D 8 0 z � O � w �� � � i aW � � aa� a o o F N .. Z M N M O NN�N N O N m In x W Q �''' ppG Z Q'❑❑❑❑ 1-'11'ln❑❑ .=fV M'C N 10 ❑❑❑ ❑F❑•❑ 1--IL'ILAJ❑❑❑ U o 9_ _ ci a v G J a I I I I I I I I I I GI I I I I G <� I 0 i I I o I I I I I I I I I I I I L r ;9>4 Cj L �j •. . W t • a z b0 t a z toN 'to N �1 O N obi rn W ~ N3 0 EXISTING 105c14'ROLL-UP E" M MAINTAIN `'o EXISTING Ux7-0 DOOR MAINTAIN Q a TOP OF STEM:1'-0" N-°i TOP OF STEM:IV TOP OF SLAB:FIELD MEASURE EXISTING 8"x4'TALL CONCRETE STEM WALL ^ N= cto 0 to v an 1Y4" I I N���Illnllllllll��ll O O (�pl v N 6N � I EXISTING SLAB ON GRADE MIN 6 DEPTH O O O Lj W TOP OF STEM:IV* 8' CONCRETE SLAB:0'-0" %0co ao y Eg Ilk 22 3 t.0 , 1 is r,E zv s o -S SJ NAL Date.- to d�a9 Job: 1,14 -w1 Sheet: S10F 5 z O00 ON f 1p O STEEL MOMENT FRAME,SEE S5 Q — — — � a Uv NJ I a N= 4W4'CONCRETE �~ o VAULT "`'il �c ° ° L o 000 a Q an �1111joillillillillill co I) ° co N T 0 CONCRETE VAULT O O O 3-0x7-0 ETAL DOOR 5'-5"0 CONCRETE VAULT co O� :o C h STEEL DOOR FRAME SEE S4 y WT 10-0x14-0 ROLL-UP a R� LST a�i � � 5' 10, S' A"' I�; Vv _ $ g Q ISTIEN ANAL Dots: 1a5Jm (0 (, a 9 Job: 1547-001 Sheet: S20F 5 z ` 01N 01N 0 OD My O N 0, ELASTIC SEALING MEMBRANE C4 rT, � 3 FROM EXISTING BUILDING SIDING TO NEW ROOF. W E,, (0 o; DIFFERENTIAL HORIZONTAL MOVEMENT BETWEEN BUILDINGS. ~~ O V d Qc � c Q W O Ino NJ 0 O i 600S162-4 PURLINS 2&p RIBBED ROOFING [ FLUSH MOUNT MATCH EXISTING COLOR 00 SPACING PER METAL ROOFING a STD 54-n*ANGLE CLIP (3)#10X%"SCREWS .........----L N y a N 6WT150-33 END CAP u- J ` m 1,CC,1 W 6"B0X BEAM y c; _ v_ nCO d O''AL a Dote. 1LV5✓1009 fo'b(a9 Job: 1547-001 Shoot: S30F 5 54-mi1 2%2'WIDE PLATES v x ro N t 350S162-33 WEB&BTTM CHORD (6)#10x%-SCREWS PER MEMBER 10 3/'FROM EDGES, %'SPACING o 600S162-M TOP CHORD 5' '` CT, o 0 E►1 d x o LLQ I I a I I � m I ° ° I 26-ga RIBBED METAL SIDING AND ROOFING 0 N o MATCH EXISTING COLORS o , ^ N HSS6x6x3/16 L 0 ~ a o 0 to �� o I10, I 0 C to `�1 U a^ I %g"RATED SHEATHING,EDGES BLOCKED I � No. 10 FLAT HEAD SCREWS 0.333"MIN HEAD DIAMETER I `;s�' ' SPACING:4"dc EDGES END PANEL ( t r) ,� ����gllllllihnb��� 6101c EDGES SIDE PANELS, 1210 c FIELD I (orb 09 TRACK BLOCKING SHEAR PANEL SEAM I (typ) I 9/,g"FILLET OR GROVE WELDS, E70XX ROD I I I SEE ROLL-UP DOOR PRINTS FOR BOLT PATTERN ° I - I I I cc #4 BARS,EVENLY SPACED BETWEEN ALL-THREAD r ,�,� � I "A36 BASE%2 SIMPSON'SEr EPDXY4'EMBED %g"HOLES y I lo I I q ` irk I, 1 o %2"ALL-THREAD,SIMPSON'3ErEPDXY I 1�2" �.— 1�2. (n 3 4'EMBED INTO EXISTING SLAB (2)MIN PER TRACK,48"o%MAX SPACING F I O O c Ioo ELEVATION 1'-0" $ I I O o ELEVATION 0'l o \ 6' 6 I - I a v • T° � a ° BASE PLATE Dote: fa5�zoos I I u iT IJob: 1547.001 Sheet: S40F 5 �} z 0)N 4N O NOD 0) 20' H '° o o W10x19 a 6• (6)3/•A325 BOLTS W/WASHERS o o v %Z"A36 END PLATE N r✓y'i�% �r�1 la ^C �� % STIFFNER PLATE(0) ! a M �✓o �", p( 31160 FILLET&GROOVE WELDS a�; E70XX ROD z' t ��� �f�� „� Q �� �IIIIIIIIIIIIIIINIIII�� �`rl°�'����v INdghNall _ - - --- - ---- - ---- - ---------- - - - - - - - - - --- - -� --- - -- ---- - -- - ----------- 3 3 '4 i W y 1111610 HOLES c j 2!12 LL G O 5�e TOP OF STEM:V-0" CO SIMPSON'SET'EPDXY r c 4•EMBEDMENT C (2)#3 HOOPS AROUND BOLTS NON-SHRINK4,000-psi GROUT O o c 8 Y 2 a 2 g u u 6-314NX12-516"PEDISTALS NON-SHRINK 4,000-psi GROUT a BASE PLATE Date: 1Q/5/1009 1/2'A36 ,lob: 1547.001 Sheet: S50F 5