Loading...
HomeMy WebLinkAboutBLD-2010-0489 - FIRE SPRINKLER 1035107-1 02238 12/2012010 001 9 c. Permit Fees 000-1 31 $115.88 Y 4 ._r City of Anacortes Permit#: BLD-2010-0489 �. 904 6th Street Issue date: 12/20/2010 Expire date: 06117/2012 Anacortes, WA 98221-0547 (360) 293-1901 Job Address: 1400 4TH ST Permit Type: Fire Sprinkler Permit ANACORTES WA 98221 Project: APN: P55673 P55679 P55366 P31513 P31514 P31515 P31516 P31517 P31518 Remarks: Modify the existing wet pipe automatic fire sprinkler system to accomodate the new tenant improvement including new walls and ceilings. Owner: TRIDENT SEAFOOD CORP Contractor: COMMERCIAL FIRE PROTECTION INC Address: PO BOX 17599 Address: PO BOX 128 SEATTLE WA 98127-1269 MOUNT VERNON WA 98273-0128 Phone: (360)293-3133 Phone: (360)848-9093 License#: COMMEFP132MM General Information: Fees: Building Valuation 2800 Building Permit Fee 67.50 Plan Review Fee 43.88 State Building Code Fee 4.50 Total Calculated: 115.88 Deposits/Receipts: 0.00 Total Due: 115.88 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. WNER OR ORIZED AGENT ISSUED BY Commercial Building Permit Application Building Department P.O. Box 547 Anacortes, WA 98221 Phone No.: 360-293-1901 FAX: 360.293.1938 SITE ADDRESS:1400 4th Street AjP R � 1R `Lfi Name Commercial Fire Protection, Inc. Modify the existing wet pipe automatic fire 17199 Bennett Rd sprinkler system to accommodate the new Address tenant improvement including new walls and City/State/zip Mount Vernon, WA 98273 ceilings. Phone 360 848-9093 FAX 360 848-1072 State License#COMMEFP132MM ExP 08/16/12 City of Anacortes License Name Trident Seafood Address City/State/Zip F 3 CT ALUA!rI1�1�2800.00 Phone FAQ{ E-Mail Address Number of Stories Building Area: t Appuit ls`Floor s.f. 2"d Floor s.f. Name Yd Floor s.f. Basement s.f. Address Lot Area s.f. Construction Type City/State/Zip Use Zone Phone FAX Impervious Area E-mail Address Other(Describe) I LENDER INFORMATION MUST BE PROVIDED FOR PROJECTS OVER$5,000 Name IN VALUATION PER RCW. Address Name City/State/Zip Address Phone FAX City/State/Zip I E-mail Address Phone No. � Q. CONTINUED ON THE BACK Commercial Mechanical Fixtures Fuel Type ❑ Natural Gas ❑ Electric ❑ Wood ❑ Propane Gas ❑ Other Type of Equipment Number of Type of Equipment Number of Fixtures Fixtures Furnace<=100K BTU Gas Fireplace Boilers/AC/Heat Pump Other Units Gas Outlets Ventilation Fans Gas Water Heater Range Hood Commercial Plumbing Fixtures Type of Fixture Number of Type of Fixture Number of Fixtures Fixtures Toilet Utility Sink Dishwasher Hose Bibb Hand Sink Water Piping Kitchen Sink w/Dis osal Additional Fixtures I Clothes Washer Electric Water Heater I HEREBY ACKNOWLEDGE IF HAVE READ THIS PERMIT APPLICANT AND STATE THE INFORMATION IS CORRECT,AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING ACITIVIES COVERED BY THIS PERMIT APPLICATION. WITH THIS PERMIT ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT WASHINGTON STATE CONTRACTORS LICENSE AND A CITY BUSINESS LICENSE.STOP WORK ORDERS WILL BE ISSUED ON JOB SITES WHERE CONTRACTORSISUBCONTRACTORS ARE WORKING WITHOUT PR ER CE A 121011� SSIGNATURE DATE Last Updated 11-29-05 March 14, 2008 Sprinkler 41a MICROFAST@ AND MicrofastHP® QUICK NiKiNC4 RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast® and MicrofastHP®Quick Response Pendent Sprinklers are small, thermosensitive,glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements.The special Polyester and Teflon®coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval s . Chart. (Note: FM Global has no approval classification for Teflon®and Polyester coat- tz ings as corrosion resistant.) I< 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Viking Technical Data may be found on Minimum Operating Pressure: 7 psi (0.5 bar) The Viking Corporation's Web site at Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for http://www.vikinggroupinc.com. use with water working pressures ranging from the minimum 7 psi The Web site may include a more recent (0.5 bar) up to 250 psi (17 bar)for high-pressure systems. High-pres- edition of this Technical Data Page. sure (HP)sprinklers can be identified by locating "250"stamped on the deflector.All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to-65°F (-55 °C) Overall Length: Refer to the Approval Chart Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cl1000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 0666613,Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 MICROFAST"AND MicrofastHP® QUICK 11110: RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Teflon®Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon®Coated For Polyester Coated Sorinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast®and MicrofastHP®Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome-Enloy®= F, White Polyester= M-/W, Black Polyester= M-/B, and Black Teflon®= N Temperature Suffix(°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° =G For example, sprinkler VK302 with a 1/2"thread, Brass finish and a 155°F/68°C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B.Wrench for coated and/or recessed sprinklers: Part No. 12144W/B**(available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A'/"ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast®and MicrofastHP®Quick Response Pendent Wrench Sprinklers are available through a network of domestic and Flats international distributors. See The Viking Corporation web site for Pr o tE t the closest distributor or contact The Viking Corporation. o® Sprir k,err ap 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. M896 Figure 1: Standard Sprinkler Wrench 10896W/B March 14, 2008 Sprinkler 41c MICROFAST11 AND MicrofastHP® QUICK RESPONSE PENDENT -NIKJSPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 9161 Ordinary 135°F(57 °C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175°F(79 °C) 150°F(65-C) Yellow Intermediate 200°F(93°C) 150°F(65°C) Green High 286 °F(141 -C) 225°F (107-C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. z Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41 d.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon®coatings. Sprinkler Wrench 12144W/B)K)K for installing coated and/or recessed pendent sprinklers y Carefully slide the := with protective caps. _I_- wrench sideways 1 around the protective cap, ensuring engage- Ment with the sprinkler xxA 112' ratchet is required wrench flats. (not available from Viking). Figure 2: Wrench 121"W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41d March 14, 2008 MICROFAST11 AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT I BSP U.S. metricz Inches mm cULus° FMs NYC' VdS LPCB C E o` Standard Orifice 06662B I VK302 1 1/2" 15 mm 5.6 80.6 2-1/4" 1 58 A1X, 131Y I A3X,63Y AlX,B1Y A3 A3X, 63Y C3X, E3Yi3 C3X, E3Y1f Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 A1X, B1Y A2X,B2Y A1X,B1Y -- A3X C313 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 G3 06765E VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A1X,B1Y — A1X, B1Y A3 Small Orifice' 06718610 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 A1X,B1Y A2X A1X,B1Y 06720B1O VK331 1/2" 15 mm 4.2 60.5 2-1/4" 58 A1X,B1Y A1X,B1Y 06932E VK331 10 mm 4.2 60.5 2-3/8" 60 A3 - G214 Maximum 260 PSI(17 bar)WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT I BSP U.S. metric' Inches mm cULus° FM NYC" VdS LPCB fi E 12282 VK317 1IT 15 mm 5.6 80.6 2-1/4" 58 A1X,61Y — A1X - Maximum 250 PSI(17 bar)WWP Small Orifice' 1229010 VK342 1/2" 1 15 mm 2.8 40.3 2-3/16" 56 1 A1X,B1Y — A1X Approved Temperature Ratings Approved Escutcheons A-135 OF(57°C),155 OF(68°C), 175 OF(79°C),200 OF(93°C), Approved Finishes X - Standard surface-mounted escutcheon or and 286 OF °C) B-135 OF(557°C), 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-1 Adjustable 1 155°F(68°C),175°F(79°C),and 200°F(93°C) C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and 286 OF ester71, Black Polyester'', and Black Escutcheon12 (141 °C) Teflon87 Y - Standard surface-mounted escutcheon or D- 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), and 286 OF 2-Brass and Chrome-Enloya the Viking Microfast® Model F-1 Adjustable (141 °C) 3-Brass,Chrome-Enloy®,White Polyester', Escutcheon12 or recessed with the Viking E-155 OF(68°C), 175 OF(79°C),and 200 OF(93°C) and Black Polyester' Micromati& Model E-1 or E-2 Recessed F-155 OF(68°C), 175 OF(79'C),and 286 OF(141 °C) G-155 OF(68°C) IEscutcheon Footnotes 1 Base part number is shown.For complete part number,refer to Viking's current price schedule. 1 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. °Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5 FM Approved for use only in wet-pipe sprinkler systems(or preaction systems qualifying as wet systems)for protection of occupancies described in the Factory s Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. Accepted for use,City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 7 cULus Listed as corrosion resistant. 'Other colors are available on request with the same Listings and Approvals as the standard colors. 'Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only.Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized O The sprinkler orifice is bushed. 11Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol. 16. "The Viking Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13`E Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 CE Certified,Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. t5 19 MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. March 14, 2008 Sprinkler 41e MICROFAST@ AND MicrofastHP® QUICK w4ils :RESPONSE PENDENT SPRINKLERS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com cULus Listing Reauirements: Microfast®and MicrofastHP®Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets(including 2-8N)and Technical Advisory Bulletins.FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards, whenever applicable. Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/8" 2-1/2" (63.5 mm) maximum (54 mm) 1/2" (15 r,m) NPT Tr(44.5 2-1/4" mm) 2" 1-1/2" (38.1 mm) I 1 mm (58 mm) <50,8 mm) Minimum (41�) � Maximum Installed with a Pendent Sprinkler standard 1/8" surface- p Installed with a Microfast 06662B (VK302) mounted escutcheon. Model F-1 Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 41f March 14, 2008 MicrofastHP® QUICK NIKJW*iRESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 2-1/8" Ceiling Opening Size 2-1/8" (54 mm) 2-5/16" (58.7 mm) minimum (54 mm) 2-1/2" (63 5 mm) maximum B�1►°I[alb® B�B►°I�Bb� 1-3/4" 1-1/8' (28.6 mm) (44.5 mm) Minimum 2" 1-1/8" (28.6 mm) �_ (50.8 mm) Minimum Maximum + Maximum L Installed with a Micromatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 06666B,Added Dry System note in approval chart for Small Orifice.) H K GENERAL NOTES 2♦'$ 1. ALL GROOVED COUPLINGS TO BE RIGID TYPE UNLESS NOTED OTHERWISE. ARMOVER WITH V=IPUNG PER PUN 2. ALL STEEL PIPE TO BE AS FOLLOWS: ERIGw SIEE WTTR IIPRIGIR 8P%NNIFA—� SCHEDULE♦0 BR:CIflG4TgNS PIPE WALL INTERNAL WEIDHTOF CIRAGMY IN SIZE THOXNESS DIAMETER ENDPREPTYMS Fl EORPE OA ANSI". BMNCHUNE 0133 OIB THREADED.COT d ROLL GROOVED.PWN END,PIX&ED 2.060 OOH 1,/♦ DAQ 1.383 THREADED,CI.FT d ROLL GROOVED,PLAIN ENO,POU8HE0 P.890 O.WB BRANCHUNE J 1 1/! 0.1♦6 1.810 THREADED,CIIt 8 ROLL(iROOYED,PLAIN ENO,POLISHED 3.610 0108 - T 2 a.151 2.a87 THREADED,DDTd POLL GIIOOYEO,PLAIN ENO,FOU&IEO 5.190 0.174 ! B$ 21/2 0203 2.♦BB THREADED,CU d ROL GROOVED,PLAIN END,POLISHED 7.863 02♦B 1'x 12'FIE%HFPD FpOEL� FIEXHEN]MWEL AU. SCHEDULE,OSPEGFlGAnms 1 :.... :. - .. S� THICIOlm D METER END PREP TYFES FIMPIPE CGKlA B/F. 3 _.-, 1 O,IOB tw7 R GROOVED,POLISHED,PU END(BUR WNG) 1210 0.018 I 11/4 0108 1N2 NXLGROOVW,P WED,PLWEND(BURWEIDNG) 25= o.a65 --` ......� 1la 0108 1.682 ROLLORO3V®.POLISHED.PLAN END(BIRT WELgNG) SOb 0.116 f•.._.-". , -_ ..._f--' "' .._ NEWSTEMADMTINSTILLIID 9ELOW ACT LOUNG pCi CHONG� ACT CEIUNG� 2 DIM 2157 ROLL GROOVED,POLISHED.PLW END(BUIT WELONO) ♦.= DAN III RECESSED SSP� 21M 0.101 2.8b flOLd(1ROOVFA.PWN ENO(BUR WELDING) 5.BS0 a2K1 RECE95EDSSP 3 0.1m 3TB0 ROLLGROOVED.PWNEND(BIIRWEIDING) 7.81a a.♦O 6 Dl1 LL 6.%7 ROGROOVED,PLUNEND(B WEIDN IITTG) 2003 I'M 6$ I \iEMSTINGPENDBITSPRINMER ! TPICAL B 0.168 B.2♦S ROLLGROWED,PWNEND(BUTTWRDNG) ♦015 2]70 1 I I I 3. MAXIMUM DISTANCE BETWEEN HANGERS TO BE AS FOLLOWS: NOMIN&PIPESIZE 3/1 1 1 1114 11M 2 21n 1 3 1 ♦ 1 5 1 6 1B _............ 7 I 7 STEELPq£ NIA 124) 12G I" 150 160 15a I" 158 I 15a I150 II I I E%fSTIKGSPPoMIO�IRPI%NO TO�PEMNN AS NS(Al1�D I RELOCATE EMI3nNDPENDENT SPANMB'� ' ADD EW PENOEN.0tMET Fl1 REu manNG 1•ouREr I a SCOPE OF WORK i e$ I ; I II l I I - rEYJSTING BPMNNIER%RNG S r 1 ! TO REMAN M NSTA B'$ 3$ COMMERCIALFIRE PROTECTION(CFP)WILLMODIFYTHE EXISTINGWET PIPE AUTOMATIC FIRE f RELOGTE EMsnNO PENfEl1TSRENMHV Roo EWPENDENTSP%NNLER SPRINKLER SYSTEM TO ACCOMMODATE THE NEW TENANT IMPROVEMENT INCLUDING NEW $` WDH 1•.1/ranNFi�� RE uEwsnNo rOUTLET WALLS AND CEILINGS. CFP WILL BEGIN WORK INSIDE THE BUILDING AT THE EXISTING WET PIPE AUTOMATIC FIRE 7 -T SPRINKLER SYSTEM. ,$ CUTi11 '-TEE CLARIFICATIONS f ADD(1)NEws I a I 1 ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM OF 40°F TO PREVENT FREEZING. I I 2. CFP ASSUMES THE STRUCTURE TO BE ADEQUATE TO SUPPORT THE SPRINKLER SYSTEM.! 1 L EXI GPENOENTSPkNIOER TYPIQL BP 41 I I REMMEEMTING PENDENT B%INNER II 4 ! I EXCLUSIONS - —y� WRH 1'a1IT RFXII6T�1 LABEL DOOMEKE, L MSG GS RIN R%%NG 1. PAINTING OR LABELING OF SPRINKLER PIPING AND/OR EQUIPMENT. I I i I TOR NN AS NSTALIED � KIND.---- �-- --; , - i � .--.-----! 2. ELECTRICAL WIRING OF ANY ND. 3 � 3. CENTRAL STATION ALARM EQUIPMENT,WIRING,AND MONITORING. 4. ALARM NOTIFICATION DEVICES(STROBES,BELLS,ETC)TO BE SUPPLIED AND INSTALLED BY FIRE ALARM CONTRACTOR. PRODUCTION OFFICE PROCESS FLOOR STEAM DUCT LABEL ROOM .lice SCALE 1II'=1'$ SDAIE 1P'=1'$ SCALE tls•=r$ DESIGN CRITERIA PER NFPA 13-2007 EDITION INSTALLATION OF SPRINKLER SYSTEMS OFFICE UGHT HAZARD .10 GPM/SQ.FT.OVER 1500 SQ.FT. SECTION 11.2.3.2.3.1 ALLOWS FOR A 40%REDUCTION IN THE DESIGN AREA WITHOUT REVISING THE DENSITY WHERE USTED QUICK-RESPONSE SPRINKLERS ARE USED FOR CEIUNG HEIGHTS UP TO 10 FT. FINAL DESIGN DENSITY .10 GPM/SQ.FT.OVER 900 SOFT. NO ADDITIONAL HYDRAULIC CALCULATIONS ARE PROVIDED FOR THIS TENANT. THIS TENANT IMPROVEMENT IS LESS DEMANDING THAN THE HYDRAULICALLY MOST DEMANDING AREA ORIGINALLY CALCULATED FOR ORDINARY HAZARD GROUP II-.20 GPWSQ.FT.OVER ISM SOFT. n CITY C!—'ANACORTES PERMI f ,EN TER Oy� D PLANS 7 OL BCIIDD, ,4 VX �gy , 0 RMIT NO. 9• L6v6I URESS i�f 6o Lf /_sY I I I ., Mike . 58 (;ROVED BY'—__ 30 1 1-_ 58"� Si re 10 TIO FIELD INSPECTION. OVERSIG 16 1*0 D. 9A, OR VIOLATION OF rODE IS NOT INCLUDE ��`m,,"/•°„nn dP'1OV`e` � ' t4rOlgh DID HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS CONTRACT W^H COMMOaCit6 P188 PBOT6CT101. INC. SYM 8NI MY111FILNREA TYPE NCDEL "' `�"°®' "' "� w '"•^" us .W.x,weRm noon NO, DATE BY REASON FOR REM6,0N Iv avow ff rx, 12 CENTERUNE OF PIPE TO REFERENCED e°P Rom,a o STRUCTURE IN INCHES TRIDENT SEAFOOD$ 1188 pill R ROPD Vim VIMNG RECD SEP W*IX? WHITE WHITE 5A 10 Iw 13 o e�w E VEIMON WA BB27J I_ SWAY EMin1QU SWAY GLACE 14004TH STREET LICEN6E ICOM I.EFP132MM NUMBER INp TES TYPE ANACORTES,WA 98221 PwPaE. (aB�I�6-em' F":(36M NB-tan .w• raolr vwru ?'- ♦WAY EMHHOUAJE SWAY BRACE T NUMBER INp TES TYPE o HANGER LOCATION PROJECT MANAGER:JEFF JOHNSON TRIDENT SEAFOODS PRODUCTION OFFICE ELEVATION PROVE REFERENCED PHONE:360-299-7052 CELL:39G220-7488 POINT IN FEET AND INCHES 14M 4TH STREET FAX. ANACORTES,WA 98221 0 HYDRA000 C UTION NODE SUPERINTENDENT: �- FLE%IBIE LOURING PHONE: FAX: DESIGNER DATE SHEET JOB N . 19 �- RIGID CWWNG AUTHORITY HAVING JURISDICTION:CITY OF ANACORTES ON PLAN MIKE HINTON I2ll l0 1 OF 1 2010555