HomeMy WebLinkAboutBLD-2010-0385 - COMMERCIAL TENANT IMPROVEMENT 1026602-1 0138 09/23/2010 001 6
Permit Fees 008837 $153.00
Al Off:_. City of Anacortes Permit#: BLD-2010-0385
904 6th Street Issue date: 09/23/2010
P.O.Box 547
n Expire date: 03/21/2012
oAnacortes, WA 98221-0547
9 L.O,��
(360) 293-1901
1400 4TH ST Permit Type: Commercial Re
Job Address yp air/Alter Permit P
ANACORTES WA 98221 Project:
APN: P55673
P55679
P55366
P31513
P31514
P31515
P31516
P31517
P31518
Remarks: Create 500 sf exercise room in existing storage area.
Owner: TRIDENT SEAFOOD CORP Contractor:
Address: PO BOX 17599 Address:
SEATTLE WA 98127-1269
Phone: (360)293-3133 Phone:
License#:
General Information: Fees:
Building Valuation 4296 Building Permit Fee 90.00
State Building Code Fee 4.50
Plan Review Fee 58.50
Total Calculated: 153.00
Deposits/Receipts: 0.00
Total Due: 153.00
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I
HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL
PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR
NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER
STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
SIGNATURE OF OWNER UTHORIZED AGENT ISSUED BY
[Dote
by RS
Project Information IBC Requirements Second Floor Plan Notes Drawing Index
by
PROJECT DESCRIPTION: S BUSINESS GROUP (IBC S@CflOn 304) 01 Dimensions are to centerline or face of concrete, steel and wood Al Project Information
05/07/10framing members unless indicated otherwise. Second Floor Plan
This project consists of tenant improvements to provide new second floor
g OCCUPANCIES 0 Existing pre-engineered steel building. ® Partial Second Floor Plan
office and storage areas. Business Offices Business Group B (IBC Section 304) 9 p 9 g Room Finish Schedule
OWNER(S): Food Processing Factory Industrial F-1 (IBG Section 306) Door Schedule
Moderate Hazard Occupancy O3 See Mechanical,Ventilation and Electrical, Lighting Plans for Window Schedule
Trident Secfood Corporation-Treasury Department heating, ventilating, plumbing and electrical requirements.
OCCUPANT LOAD (IBC Table 1gD4.1.1) A3 Partial Second Floor Reflected Ceilin Plan
5303 Shilshole Avenue NW New Business Areas: 1 occupant per 100 SF grass ® Provide accessible routes of travel to all portions of the building. g
Seattle, WA 98107 878 SF/100= 9 occupants Maintain 32"clear aisle width in areas serving only employees, A4 Construction Details
PROJECT ADDRESS: Maintain 36"wide minimum clear aisle width in public areas where
EGRESS (IBC Table 1015.1): 1 Exit allowed w/49 occupants tables,furnishings, or other similar obstructions are placed on one
400-4tfi Street 9 a 49 = 1 Exit required. side of the aisle only, and 44"when such obstructions are placed on
Anacortes, WA 98221 both sides ofthe aisle. t>J ���jjj
END
CORRIDOR' maximum per IBC 110D17.3 2 All doors which have a latch set or lock shall have lever type Z VO Lu
LEGAL DESCRIPTION: operating hardware. Locking mechanism to comply with IBC )
TYPE OF CONSTRUCTION (IBC Table 601):Type 11-8 Sections 1008-1.8.3 and 1008.1.8.3. Flush or surface bolts and not s Q — O
Anacortes Lot 4, Black 107, Portion of vacated 41h Street, less 22 feet of Lot ., -> t-
Qermitted. Door must unlock with one operation. Q r
S all of Lots 2 to 4. OCCUPANCY SEPARATIONS (IBC Table 508.3-3):BIF-1 w a. t (� � Zca
Section 13,Township 35, Range Ot,W.M. {i
Not Required D-
ASSESSOR'S TAX ID NO: AUTOMATIC SPRINKLER SYSTEM � W �, N N
3772-107-004-0009 (P 55673) Fully protected throughout complying with IBC Section 903 O t r Q — ri co r.
O W O
ZONING
QZ
25'-0" 24,-6" 24%6" 24'-6" 24'-6" 24'-6" 24,-6" 24•-6" 24'-5" 25'-0" A r m 0 } r�� ••
Light Manufacturing (LM) a, d J ,
PERMITTED USES 7 `,
Q � � � L ra V O �
Processing or storage of goods (Food Processing). f I I I I I I. I Q
BUILDING HEIGHT: Four stories
35'-D" City of Anacortes Height(36 Maximum)
Office Office Office ! 'lest I C. r
BUILDING SETBACK REQUIREMENTS: I i i Conference KLgnch& Laboratory I. Mechanical
CN
Roam j � W cV
I I I 4 o
SECOND FLOOR BUILDING AREAS
5,545 SF Business (Existing) I O New Office
38,758 SF Processing (Existing) I I o ! and Storage
44,303SF TOTAL (Existing) i SuPPly Office Mail o improvements; i �o ,°�,°
878 SF Offices (New Tenant Improvements e — -- —�` --'--' -- 0
from — -Q O c*�
from Processing) I Personnel I I I I I O N
office I j I I I I I o
CODES:
I I I I I j I
2006 International Building Code(IBC) I I I Processing/Storage
ICC/ANSI Al17.1-03, Accessible and Usable Buildings 8 Reception
I I
2006 International Mechanical Code(iMC)
I I I I I i I
2006 International Fire Cade(IFC)
2006 Uniform Plumbing Cale(UPC)
2008 National Electrical Code (NFPA 70)
1 2006 Washington State Energy Code
2006 Washington State Ventilation and Indoor Air Quality Code j I TO Scrubber I I I
# 1. Room Room
City of Anacortes Zoning Ordinance
i I I ►! I I I I I I I Boiler Z
i I. L I I i } I I&WH O
I I I I I I I I I -y
I I I I I I I
6 i I I I I I j I E
>
I j I I I i p O
I I E
I l I I I U en
I ! I I I I N W I O Q CU
I I I I I { I
I I I I I I yJ'�tUN� I
r�o ! O
I I I { I I IMID � to
�
LL 'f
Q p
m W CQ
�
� to
I I I I I I Q
�}-- --- I -J- I--
I I i I i i i •�
I I I I Locke I Private I Z
I I l I Lunch I 0W
I Area I 01 a Q
I i I I I I
Lunch
Area I I
I I
I I I I I I I
i
110 Vending I Z
M Machines I
I i I I I Locke I I
1 -- -- -- --- - Pq
Second Floor Plan
I. o s 10 20
11 I 1 I I I I I
r F SCALE: 1116"= T-0" Project oOJ
K
Number
Sheet A l
Number
sheets
Drawn by RS
Room Finish Schedule Door Schedule Window Schedule Second Floor Plan Notes Checked by
r+ (W x H) (W x H) Sash/ O Dimensions are to centerline or face of concrete, steel and wood framing members Date 05/07/10
Room Name --- Val lery Mark Opening Size Pairs Thickness Type Const. Finish Glass Remarks Mark Opening Size Finish Type Glass Exit Screen Remarks unless indicated otherwise.
Mark ---------- 1 A 2
OZ Existing pre-engineered steel building. ev.
1. T-0"x T-0" - 1 34' Interior X - - (2)
Description------- Floor/Walls/Ceiling A 6-0" x 4'-0" X X X - - (1)
2. T-0"x T-0" 1 3/4" Interior X - - -
3. T-0"x T-0" - 1-3/4" Interior X - - - O See Mechanical and Electrical Plans for heating, ventilating, plumbing and electrical
Mark Surface/Substrate/Base Finish Remarks 4. T-0" x T-0" - 1-3/4" Interior X - - - LEGEND: "X" shown on schedule indicates typical. requirements.
5. 3'-0" x T-0" - 1-3/4" Interior X -- -- - -
Sash/Finish: Typical = Vinyl sash and frame, white. O4 Provide accessible routes of travel to all portions of the building. Maintain 32"clear
aisle width in areas serving only employees. Maintain 36"wide minimum clear aisle
FLOOR
LEGEND "X" shown on schedule indicates typical. Type: Typical = Horizontal slider. width in public areas where tables, furnishings, or other similar obstructions are
placed on one side of the aisle only, and 44"when such obstructions are placed on
1. Carpet - (3) Pairs: Number of doors in mutt-component onent unit. both sides of the aisle.
2. Existing (2) P Glass: Typical = Clear, Low-E, argon gas-filled, insulated glass.
Construction: Typical = Wood or hardboard, solid core. (Glazing U-Factor= 0.40 or better) O The floor of landings at doors shall be not more than 1/2" lower than the threshold of
WALLS the doorway. Landings shall have a width of not less than the width of the door.
Landings shall have a length measured in the direction of travel not less than 44"
Remarks: except that within the accessible route of travel, the length shall not be less than 60" p
A. Gypsum wallboard Paint (1) Remarks v
B. 3132"thick Marlite FRP - - (1) Provide safety glazing as required by location. on the swing aside.
C. Existing (2) (1) All doors which have a latch set or lock shall have lever type operating hardware. r /1
Locking mechanism to comply with IBC Sections 1008.1.8.3 and 1008.1.8.3. Flush or O All doors which have a latch set or lock shall have lever type operating hardware. V J � 9
surface bolts and not permitted. Door must unlock with one operation. Locking mechanism to comply with IBC Sections 1008.1.8.3 and 1008.1.8.3. Flush —
CEILING or surface bolts and not permitted. Door must unlock with one operation. +,
(2) Tight-fitting solid core wood door with weather-stripping and automatic self-closer. • N
O Exit and Emergency lighting. See Electrical and Lighting Plans for additional 00
1. Gypsum wallboard Paint (1) V a,
requirements. v
2. Suspended acoustical grid ceiling - - �
3. Existing - (2) Og Install (2A10BC) fire extinguisher (FE) as indicated. Verify requirements with City of (`� r~
Anacortes Fire Marshall.
Remarks: O Existing 9" diameter air supply duct to remain. V p >~
(1) Fire-taped 5/8"thick Type "X"fire-rated gypsum wallboard. ca
-
(2) Modify, patch, or repair as required for new construction.
(3) Provide 4" high resilient base. 10 Existing steel cross bracing to remain. • *..� E
,� V
11 Typical 3-5/8" steel stud wall framing spaced at 24" on center with 518"thick gypsum V
wallboard (GWB) at each side.
�1 C. ug
12 6" steel top and bottom track with 2-1/2" stud wall framing spaced at 24"on center 6 9 13 �I�i y A
(staggered)with 518"thick gypsum wallboard (GWB) at each side. Provide 3-1/2" A4 A4 A4 N
F T
H thick unlaced glass-fiber acoustical insulation. ^
D CD
13 Provide 3/32"thick Marlite FRP over 5/8"thick gypsum wallboard(GWB) at 10 + can
24'-6" 24'-6" Processing Areas. A4 A4
cc
6'-0" 6-2 1/4" 5'-11 5/8" 14 3-5/8" steel stud wall framing spaced at 24" on center with 5/8"thick gypsum QJ Fx,
wallboard (GWB) at Hallway side. A4 A4 r
?�N 15 Remove existing non-structural steel stud wall wall framing as required for new 00
O V N
w 2 construction. n
,6 Existing steel stud wall framing to remain. Modify, patch, or repair as requried for 00 N
^
... s new construction. CD
All PA]
I I I Stairs '� Existing 10
Existing Wall 47/8" 11W114" 11'-111/2" 47/8"
11_L-L _L—I__L J-1_L LJ 1J 16 4 7!8" Z
O Z __,....._...__�_... ._._ —
Existing
Wall
Storage Office Office Office 16
1 A 1 11 1 A 1 11 1 A 1 1 A 1
N
Laboratory 18" °°
Existing z (Min) ate.. O
Mechanical
® O O Room E Q
00
I 8 Existing > �C
9 FEC " '�5 7k o
Hall
�� W I GF�s k'criM Q O
12" v 1 A 1 N O 12
(Min)
y�WY Laaenwva.+�lsercr um,w.,rmw„ y, as— , X-'
.....-r . - ... .�,.._._...-...-.m nMrC*
tM SNL� ��lLI Ne
14 - IT
ICU
9y � _ ^ 13 � 13 � O Q
Hall
Vestibule 0 CO
Existing
Clean om 15 , A , � O V_
Existing �sfit� Q
W ca
ca
m ! m ^`
VJ Q
Existing 16 Lynx NTZu�,� "C Z
WallProcessing/Storage z ExYs„"`' 0 0
T-1 5/8" 4 7/8"
Existing w,q�S L
Second Floor Plans„ cro
0 1 5 10
SCALE: 1/4"= 1'-0" 'V
o--
O F
1009
A2
sheets
Drawn by RS
Second Floor Reflected Ceiling Plan Notes Checked by
ODimensions are to centerline or face of concrete, steel and wood framing members Date 05/07/10
unless indicated otherwise. Verfiy dimensions with existing conditions.
OExisting pre-engineered steel building. rRev-
Reflected Ceiling Plans do not show all heating, ventilation or electrical items. See
Mechanical and Electrical Items for additional requirements.
OSuspended acoustical grid ceiling. T-Grid ceiling system shall be rated heavy-duty 17 18 19
and installed per IBC Section 803.9. Lateral force bracing shall comply with IBC A4 A4 A4
Section 1621. Install at height indicated.
OExposed steel roof framing with interior reinforced fabric-faced building insulation.
O Gypsum wallboard (GWB) ceiling or soffit.
OGypsum wallboard (GWB wrapped beam or soffit. 0
OSurface mounted fluorescent light fixture. See Electrical and Lighting Plans for •
additional requirements. @j
N V
OSuspended acoustical grid ceiling mounted fluorescent light fixture. See Electrical C
and Lighting Plans for additional requirements. rV v
10 Exit and emergency lighting fixtures. See Electrical and Lighting Plans for additional
requirements.
♦�
Cz
�� Cz
Q�
m
F G H
a\
24'_6" 24'_6" =�
00
00
N 0 uN
N
0�0 N
O
t1
O O O
9'-0" O
O O O
91-01. 91_01,
-Cn O
JL------ IL, O E
N
20
10 el� O O 9 0 � � 0. 0
CD O
U Cn
0
� N
8. O o.. , 9 O a)
O . D,.
Q o
W c
m
Q
LU
cn Z
Z o 0
L
Second Floor Reflected Ceiling Plan
0 1 5 10
SCALE: 1/4"= 1'-0"
Project 1009
Number
Sheet A3
Number
Fof sheets
Drawing by RS
Checked by
Date 05/07/10
HANGER WIRE
3-5/8" STEEL 5/8" THICK GLASS FIBER NFACED Rev.
TYP E-X GYPSUM
TD TRACK WALLBOARD BUILDING INSULATION
EXPOSED SUSPENDED
2-1/2"x 20 GA. STEEL CEILING TEE
3-5/8"x 20 GA. STEEL C STUD WALL FRAMING
C STUD WALL FRAMING 1"TYPE "S" SPACED @ 24"O.C.
SPACED @ 24" O.C. BUGLE HEAD (STAGGERED)
SCREWSa I
6" STEEL
TD TRACK f
20 GA STEEL STUDS LAY-IN TEGULAR ACOUSTICAL
CEILING TILE Ei
O
V
STEEL STUDS GYPSUM BOARD
ACOUSTICAL INSULATION SUSPENDED CEILING
q� SCALE: 3" = 1'-0" 9 SCALE: FULL SIZE 1 SCALE: 17 SCALE: FULL SIZE 0
V a\
� V
1
2-1/2"x 20 GA. STEEL V Cts O
_. C STUD WALL FRAMING WALL FINISH
SPACED @ 24" O.C. 5/8" THICK
(STAGGERED) •
TYPE-X GYPSUM � (,
WALL ANGLE FASTEN
WALLBOARD TO WALL AS REQUIREDACOUSTICAL CEILING
V
6" STEEL TILE CUT AND RABBETED �
TD TRACK AS REQUIRED 1
3/32"THICK co
co
MARLITE FRP 2-1/2" x 20 GA. STEEL PANELS V
C STUD WALL FRAMING
Cn co w
SPACED @ 24" O.C.
(STAGGERED) Liu—I �j00
O u `-'
ON co
0000 N
STEEL STUDS GYPSUM BOARD 18 ElLI WALL ANGLE
S3" = 1'-01, SCSC FULL SIZE
N VERTICAL -'
SUPPORT
U
45 WIRE IN 1/2"
CONDUIT TO w E O
STRUCTURE
ABOVE
45
90
W
CD
45 E O
45 S O
L
M 2" CROSS RUNNER C 0
�( 2, MAIN RUNNER — O 0
M MAIN SUPPORT RUNNER @ 4'-0" O.C. MAX
BRACE AS INDICATED AT 12'-0" O.C, 144 SQ FT MAX CUCn
O
(1:#�INOSUSPENDED CEILINGO
SCALE a)
O
If
O
U
CO
♦^ Q
a I—
oZ
W
0_//
Project 1 ,
Number 09
Sheet A4
Number
of sheets
NPR"%'
> r /{' ' >'
7�9��_ w M
DOCK
U_
r' ( EXISTING
r ; � w
w -
STRUCTURE / �'� �� - t I �..I -/ �^
t , DOCK / �. \ �)✓ \I U
\� \ I I w h' � z
\ I
RE w t i _
� I \ _
b:
t
O k w -Z
_
Q ®
FUTURE I / - I O
I CONSTRUCT. I I O �, Z W 7
DQ
2 � I
i
LZ _ EXISTING t
BUILDING 1
- - - - 71cr _
0 C
• _ c � w
C ►- _I - - - I LI PROPERTY LINE (n -
EXISTING
BUILDING I O f
71 (�
- r - LL 101-
r
I ♦ Q 0
: _ I w
Z Q
r _ A � Z a
� oUo
I ,
! w cc Q
4TH STREET = F" m
N
(N V)
J J
t xI
X x
0 o I
i i B
co N
i
x
B ( x }
I
I I $ N cn I
w w
x
I O O
in
if r_ X— — X — -X X = X = — X
I x > I w w> I
w
i > W
aUj
PROPERTY LINE x
I x I NOTES: Qo
0 0 �
ALL DIMENSIONS SHOWN ARE
APPROX. AND MUST BE VERIFIED. QUANTUM CONSTRUCTION, INC. o o
Commercial Industrial WBE
12761 Quantum Lane
I I x x I Macortes, WA 98221
PROJECT: 0
r
40 30 20 10 0
— 20' 40' 80' DATE: Oc
X X X X X - - X X — X - - X _ X X — — X - - - - ENGINEER: G.T
ENGINEER:
IN FEET DRAWN BY: ELS
( )
NORTH 1-= 40'-0• CHECKED BY: G.
GRAPHIC SCALE
E CA SCALE: AS NOT=
t Y SHEET: 1 OF
DRAWING
SITE PLAN
SCALE 1"=40'-Q
PLOT DATE: 07-05-06
3 2 REV
8 .
F
RS
Room Finish Schedule
Door Schedule Window Schedule Floor Plan Notes
(W x H) O Dimensions are to centerline or face of concrete, steel and wood framing members
07110
— Gallery
(Wx H) Sash/ unless indicated otherwise.
Room Name Mark Opening Size Pairs Thickness Type Const. Finish Glass Remarks Mark Opening Size Finish Type Glass Exit Screen Remarks
Mark ------ 1 A 2 O Existing pre-engineered steel building.
Description------ Floor/Walls/Ceiling 1. 3'-0"x T-0" - 1 3/4"' Interior METAL - yZl 3 A 3'o' 3 X X X
�+ 3'0' ��, D' X X X U O3 See Mechanical and Electrical Plans for heating, ventilating, plumbing and electrical
requirements.
Mark Surface/Substrate/Base Finish Remarks LEGEND: "X" shown on schedule indicates typical.
O Provide accessible routes of travel to all portions of the building. Maintain 32"clear
Sash/Finish: Typical = Vinyl sash and frame,white. aisle width in areas serving only employees. Maintain 36"wide minimum clear aisle
width in public areas where tables, furnishings, or other similar obstructions are
FLOOR
LEGEND ")C shown on schedule indicates typical Type: Typical _ Horizontal slider. placed on one side of the aisle only, and.44'when such obstructions are placed on
both sides of the aisle.
1. Carpet - (3)
2. Existing - (2) Pairs: Number of doors in muti-component unit. Glass: Typical = Clear, Low-E, argon gas-filled, insulated glass.
(Glazing LI-Factor= 0.40 or better) O The floor of landings at doors shall be not more than 1/2" lower than the threshold of
Construction: Typical = Wood or hardboard, solid core. the doorway. Landings shall have a width of not less than the width of the door.
Landings shall have a length measured in the direction of travel not less than 44"
WALLS
Remarks: except that within the accessible route of travel,the length shall not be less than 60"
A. Gypsum wallboard Paint (1) Remarks: on the swing aside.
B. Gyps thick wallboard
FRP - ( (1) Provide safety glazing as required by location. Ca
C. 3/32"Existing - (2) (1) All doors which have a latch set or lock shall have lever type operating hardware. O All doors which have a latch set or lock shall have lever type operating hardware.
Locking mechanism to comply with IBC Sections 1008.1.8.3 and 1008.1.8.3. Flush or Locking mechanism to comply with IBC Sections 1008.1.8.3 and 1008.1.8.3. Flush
surface bolts and not permitted. Door must unlock with one operation. or surface bolts and not permitted. Door must unlock with one operation. N
CEILING
(2) Tight-fitting solid core wood door with weather-stripping and automatic self-closer. 7O Exit and Emergency lighting. See Electrical and Lighting Plans for additional V �
1. Gypsum wallboard Paint (1) (3) Duictk S+AIL fir' requirements. Q;
2. Suspended acoustical grid ceiling - -
3. Existing - (2) O Install Ana¢ortes Fi
re Marshall.
(FE) as indicated. Verify requirements with City of
V 0 �
Remarks: O Existing 9" diameter air supply duct to remain. p
(1) Fire-taped 5/8"thick Type"X"fire-rated gypsum wallboard. +, r.
(2) Modify, patch, or repair as required for new construction. 10 Existing steel cross bracing to remain. '*"1 cd
(3) Provide 4" high resilient base. V V
11 Typical 3-5/8" steel stud wall framing spaced at 24" on center with 5/8"thick gypsum 5 9 -'-
wallboard (GWB) at each side.
12 6" steel top and bottom track with 2-1/2" stud wall framing spaced at 24"on center 6 9 13
(staggered)with 5/8"thick gypsum wallboard (GWB) at each side. Provide 3 i/2" A4 A4 A4 N
i thick unlaced glass-fiber acoustical insulation.
13 Provide 3/32"thick Marlite FRP over 5/8"thick gypsum wallboard (GWB) at 9 10 ���------++++ m
Processing Areas. A4 A4
14 3-5/8" steel stud wall framing spaced at 24"on center with 518"thick gypsum 5 y V J
wallboard (GWB) at Hallway side. 00
A4 A4
QUANTUM 15 Remove existing non-structural steel stud wall wall framing as required for new O V
cV
construction.
CONSTRUCTION INC. n/ 00 00 M
O N
16 Existing steel stud wall framing to remain. Modify, patch, or repair as requried for .-.
0
new construction. m
COMMERCIAL • INDUSTRIAL • CUSTOM
I RESIDENTIAL • METAL BUILDINGS
— T --- — T — T _7 T -
Z
U)
nor - — Ib o� l� kM1� Zzd� - - A
o O
25
�(
—I CV
a
— - —+--I— f -- — 7
— — - — — t — --i O 0
I
E
-_y aw6 UJ Ca
�-
_ -
T- — — -
I
I m U)
1 I
I
-- fjottuN IM67Al
Quantum Construction, Inc., 12761 Quantum Lane, Anacortes, WA 98221
Phone: (360) 293-0656 Fax: (360) 293-4736
www.quantumci.com `
Project 009
i Number 1 I
i r , _ Sheet A2
I o I '{ 1 Number
1r
,, of sheets