BLD-2007-0030 - FIRE ALARM
Y 0 ::.. City of Anacortes Permit#: BLD-2007-0030 or I904 6th Street Issue date: 01/18/2007 P.O.Box 547 Expire date: 01/18/2008 Anacortes, WA 98221-0547 (360) 293-1901 00, Job Address: 1400 4TH ST Permit Type: Fire Alarm Permit ANACORTES WA 98221-1532 Project: APN: Remarks: Expand fire alarm system to monitor new dock sprinkler system. Owner: TRIDENT SEAFOODS Contractor: COMMERCIAL ALARM&DETECTION Address: PO BOX 954 Address: PO BOX 128 ANACORTES WA 98221-0954 MOUNT VERNON WA 98273-0128 Phone: Phone: (360)848-9093 License#: COMMEAD961 LS General Information: Fees: Building Valuation 2000 Building Permit Fee 56.25 Plan Review Fee 36.56 State Building Code Fee 4.50 Total Calculated: 97.31 Deposits/Receipts: 0.00 Total Due: 97.31 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING,WKSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNA OF OW ER OR XTHO ED AG T ISSUED BY ACCESSORYINTELLIKNIGHT i SD500-AIM & SD-500-MI M Addressable Input Modules g'r IntelliKnight's addressable contact monitor modules combine fast response with pinpoint 01 location ID. A combination that saves lives and a property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Up to 2500 ft wiring distance from - - - - The SD500-AIM and SD500-MIM are either input module to contact addressable input modules for use with Use up to 14 gauge wire the Intelliknight fire alarm control UL listed I panels(FACPs).The SD500-AIM addressable input module mounts to a Electrical Specifications 4"-square box.The SD500-MIM mini Standby Current: 0.55 mA input module fits inside a single gang Alarm Current: 23 mA max for one a box. Both input modules are designed device; 46 mA max for two devices; SD500-AIM to be used with pull stations, water flow 0.55 mA for each additional device switches, and other applications requiring dry contact alarm initiation Line Resistance: 500 max devices. Mechanical Specifications These modules are supervised, single SD500-AIM Physical Description input contact monitors. Using an EOL Dimensions: resistor, they monitor for alarm contact _ 4.9"W x 4.9" H x 1"D closures and for open circuit wiring (12.4 W x 12.4 H x 2.5 D cm) fault conditions. If a fault occurs in the Weight: 3.6 oz(120.1 g) SD500-MIM. wiring, the module alerts the FACP. Color: Ivory cover plate Each addressable input module is Approvals programmed with a unique signal line SD500-MIM Physical Description NFPA 71 &NFPA 72 circuit(SLC)loop address. Dimensions: UL 864 1.5"W x 2.5" H x 0.7" D CSFM 7300-0559: 132 Features (3.8 W x 6.4 H x 1.8 D cm) MEA 429-92-E Vol. IX • Single contact monitor Weight: 1.6 oz(45.4 g) FM Approved for use with the 5820XL • Support for Class A(Style 6& Style Environmental 7)or Class B (Style 4)wiring Operating Temperature: • Attractive ivory cover plate with the 32-F-120-F (0°C-49-C) SD500-AIM • Small and lightweight size allows for Humidity:Q flexible mounting options with the 10/o-93/o non-condensing SD500-MIM SILENT • DIP switch programmable for fast KNIGHT installation 01 by Honeywell ATELLIKINJIGHT ACCESSORY SD500-AIM & SD500-MIM Addressable Input Modules f d Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate tIX .p. .." Al14tAr .. ... ;1 ER ,nr;t:vc riEti;thi .ram y tr, i, I A L` Compatibility Ordering Information IntelliKnight 5820 FACP SD500-AIM Input Module IntelliKnight 5808 FACP Addressable input module with ivory cover plate. IntelliKnight 5700 FACP SD500-MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all FORM#350231 Rev.C,05/06 KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight Copyright©2006 Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Phone:(800)328-0103,Fax:(763)493-6475.