Loading...
HomeMy WebLinkAboutBLD-2012-0263 - RE-ROOF COMMERCIAL =G1T Y. Off._ City of Anacortes Permit#: BLD-2012-0263 f 904 6th Street Issue date: 07/26/2012 #� P.O.Box 547 Expire date: 01/22/2014 s Anacortes, WA 98221-0547 �z9Cpg`S : , `•YMN�y�r Job Address: 1011 12TH ST Permit Type: Reroof Commercial Permit ANACORTES WA 98221-2101 Project: APN: P55111 Remarks: Reroof garage Owner: PROSPERITY INVESTMENTS FLP Contractor: Address: 1582 SCENIC HEIGHTS RD Address: OAK HARBOR WA 98277-8415 Phone: Phone: License#: General Information: Fees: Building Valuation 10852 Building Permit Fee 195.25 State Building Code Fee 4.50 Total Calculated: 199.75 Deposits/Receipts: 0.00 Total Due: 199.75 c:r rt L_1 W 'r1 � rn i+ 16 N 0 C:t C? r O O •a? .tom CK � a. � o THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCEDtn HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL8 PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR— NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. ,p dld�t.z SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY Professional Services Prompt Courteous Knowledgeable Inc. Advanced Construction a Maintenance, Inc. 1151 N.E. 21 st Ct. Unit A. Oak Harbor, WA 98277 Phone: 360 678-0710 Fax: 360 678-0769 Project Binder Client Name: Rick Rennebohm Job Name & Location: Old Fire House Parking Garage 1011 12'' Street Anacortes, WA 98221 Specifications: Replacement of Roof Over old Engine Parking Garage. Upgrade Fire Rating Install pvc roofing from IB Roof Systems Material Options Chosen: IB Roof Systems 50mil Pvc Roof Membrane in White. 26ga. Cap metal on Parapets. Fly re lg et system on Masonry walls BLDG . VIEWS .............. • • • Goble earth feet 10 meters 14 �+ l ffr Skagit County Assessor Photo Page 1 of 1 Skagit County A raisal di ital hoto for arcel number P55111 . . . I► Pin wI r If http://www.skagitcounty.net/apps/AssessorNiewPicture/Default.aspx?id=P55111 7/25/2012 t T C; jib 4 Go_) Ie earth feet 80 meters 20 r PERMIT LICENSE APP . TO Re-Roof Building Permit Application 'AwV1� City of Anacortes Building Department P.O.Box 547 Anacortes,WA 98221 Phone No.:360-293-1901 FAX.360.293.1938 Type of Permit(check one) El Residential commercial Project Address: /C>I( tz4l�fir, co r Parcel ID# Z7 77--&qf-Vo Owner. Izelv&' oo Phone Number: '7 -ix""r State: ��r- Zip Code: qA�77 Address: /5,92 City:0K-'< Contractor: AVr­r4 6c-; D % --7;A::-Phone Number:,?&O 6,7 9 Address:116/ 14 City: e9P$� L­i,:-n�-r- state: "' -Zip Code:I�O�77 Contractor's License Number: 32 P.Z ---Expiration: /,0/7-10 1_3 Type of Roofing: FV7 c- Number of Layers: Number of Squares: -*-2- Class of Roofing: El A *13 [1 C Installing or replacing sheeting:-- QA1 4, 1' Work Scheduled to Benin: -713 0 Work Scheduled to End: Sz 0 The following is required for NON-Residential Buildings: F1 All Non-Residential projects will require a site visit prior to the issuance of the permit for obvious signs of fatigue, condition of existing roofing and number of existing layers. Fi Two copies of the installation specifications and U.L. listed roof assembly. El Building square footage:.r- -7 11 Occupancy Group Office Retail Church Restaurant School Project Valuation: 10 1 951;� - q �? -_ - I hereby certify the above information is correct and that the construction on,and the occupancy and the use of the above described property will be accordance with the laws,rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. 2- 7/, Applicants Signature Date State of Washington t>$t E g Business Licensing Service _ PO Box 9034 Owner pan e Olympia WA 98507-9034 - Aoft 180 1-800-451-7985 r;I City Business License Addendum Side A: For a business physically located inside city limits(resident) This form must be submitted with a completed Business license Application and required fees. For faster service-Apply online at business.ws.gov/BLS Refer to the instructions and list of cities on page 1 of this form. Complete this section for a city license if your business is ptrysically looted inside city limits. 1. From the city names and fees listed on page 1 of this form,indicate the city where your business is physically located and the associated fee amount: name Fee anwt" r 2. First date of business in the city indicated: �J 3- Have you ever held a business license in the city you indicated above? ----------------------------- ❑ Yes 0 No If yes,note the city license number of your previous business Cd known): 4. Will you use or store arty hazardous or flammable materials at this location?.................... ❑ Yes - No 5- Are you conducting the business from a residence?............................................................ ❑ Yes 0 No If yes,will business customers be visiting the residience?---------------------------------------------------- ❑ Yes ❑ No Some cities have special home occupation regulations please contact the city for more frrfor whon. 6. Square feet of floor space utilized by your business at this location: /"'.', 7. Give the name and phone number of two after-hours Emergency Contact persons for this business location: Name Phone nm im Nam`r -_ !�Y✓ �L t �'-.,'r Rtorte nmlber� 8- Are you applying as a nonprofit organization?--------------------------------------------------------------------- ❑ Yes No If yes,attach a copy of your IRS tax exemption certificate issued under section Sol(c)of the IRS code. 9. Are you a general or specialty construction contractor?..............................................E......... j I Yes ❑ No If yes,provide the Dept.of Labor&industries registration number(if known): 1 U. Mark any of the following activities that will be conducted at or from this business location: ❑ Sexually oriented Business ❑ Charging Admission ❑ Amy Devices/Arcades ❑ Adult Entertainment ❑ Taxi or For Hire Service/Dispatch ❑ Ambulance Service/Dispatch ❑ Gambling ❑ Utility(telephone%Nular/[W cable,gas,eWnc,garbage) Note: In Section 2 of the Business License Application, write the city name and flee indicated above. For assistance or to request this doc wTmt in an altamate format,visit i>Kp-.Nbusines&w&gm/BL s or caA 1 BUO 451-7985.Teletype(r rY)users may cal 3�7oS671 a. State of Washington UMa� WP7Business Licensing service CPO � `-1&iD` HoI PO Box 9034 owner noine Olymr wA 98507-9034''1,� 1-soo-451a985zP-i' City Business License Addendum Side B: For a business physically located outside city limits(non-resident) j This form must be submitted with a completed Business License Application and required fees. For faster service-Apply online at business.wa.gov/BLS Refer to the instructions and list of cities on page 1 of this form. Complete this section for city licenses N there is no physical location inside the city limits. 1. From the cities and fees shown on page 1,list all the cities where you will travel into to conduct business. Previous city license number City name First date of business (if Ivtown) Fee amount $ ,0 $ $ $ $ $ Total amount due for non-resident cities $ 2- Are you applying for your business as a nonprofit organization?------------------------------------------ El Yes ,No If yes,attach a copy of your IRS tax exemption certificate issued under section 501(c)of the IRS code. 3. Are you a general or specialty construction contractor?........................................................ Err Yes ❑ No If yes,provide the Dept.of Labor&Industries registration number(if Ivtown): 4. Do you provide utility service(telephone%eliular/ISP,cable,gas,electric,garbage)?.......... ❑ Yes ONO Note: In Section 2 of the Business License Application, write the city name and fee indicated above. For amdarm or to mquest this document in an alemate format,visit httPjftw less.wa.gmmLs or cal 1-80Q-451-7985.Teletype(TTY)users may cal 360-705.671 S_ I . B . SPECS . � u Roofing Specification for: Old Fire House Parking Garage 1011 12th St. Anacortes, WA `.rl ���: z Project Name Old Fire House Parking Garage 1011 12th St. Anacortes, WA PROJECT NAME: Old Fire House Parking Garage Description:lB Roofing Systems (IB) Mechanically Attached PVC membrane roofing system over an approved plywood roof deck, complete with related insulation, separator sheets, flashings, and accessories and performing such incidental or other work as may be necessitated by these operations. — Mechanically Attached Membrane ( 50 rail ) EPS 1/2in Fanfold `o. -- 1 Layer PS-10 Plywood Deck Assembly Overview Type: Mechanically Attached ( 50 mil ) Construction: Roof Replacement Fire Rating Class: Class "B" Slope: 0112 to .5 J 12 Membrane Color: White Roof Dimensions: Length- 49ft Width- 46ft Height- loft Warranty Type Commercial Limited Materials Warranty Warranty Length 15 yr PREPARED BY: SYSTEM SPECIFICATION NUMBER: Advanced C&M,Inc. M A- 5 0- F F- 1 F S-W SCALE:NTS APPROVED BY: DRAWN BY:IB SPECWRITER PLOT DATE: REV:AS 7-12 2877 Chad Dr..Euaene,OR 97408 800-426-1626 www.ibroof.com r a' SECTION 07543 THERMOPLASTIC MEMBRANE ROOFING PART1 GENERAL 1.01 SECTION INCLUDES. A. Provide an IB Roofing Systems (IBRS)MA PVC membrane roofing system over an approved plywood roof deck, complete with related insulation, separator sheets, flashings, and accessories and performing such incidental or other work as may be necessitated by these operations. B. Preparation of substrate to receive roofing materials. C. Installation of separator sheets/thermal insulation. D. Roof membrane application. E. Roof flashings application. F. Incorporation of sheet metal flashing components and roofing accessories into the roof system. 1.02 SUBMITTALS A. Submit product data of IBRS, samples, shop drawings, and IBRS installer certification under provisions of Division 1. B. Submit product data indicating membrane materials,base flashing materials, insulation, separator/thermal insulation, accessories and manufacturer's installation instructions and details. C. Samples: Submit 8"x I V samples of specified color of IBRS PVC membrane for approval. D. Installer Certification: Submit certification from IBRS certifying that installer is approved by IBRS for installation of specified roofing system. E. Submit IBRS certificate under provisions of Division 1 that products and installed system meet or exceed specified requirements. 1.03 QUALITY ASSURANCE A. Manufacturer: Company specializing in manufacturing the products specified in this Section with minimum 20 years documented experience. B. Applicator: Company specializing in applying thermoplastic roofing with minimum five years documented experience and approved by IBRS. C. Work of this Section to conform to NRCA Roofing and Waterproofing Manual and manufacturer's instructions. It is the responsibility of the applicator to address any conflicts or disparities between NRCA requirements and manufacturer's requirements. D. Materials: All materials shall be provided or recommended by IBRS and in compliance with specification. 1.04 REGULATORY REQUIREMENTS A. Conform to applicable requirements of the Local Building Code for roof assembly fire hazard requirements. 1.05 WARRANTY A. Water tightness: Membrane roofing system, including membrane base flashing, roof insulation, and roofing accessories, is part of the watertight integrity of the project and as such shall be warranted for Five years (or other time period as required by the state/local contractors licensing board)by the Roofing Contractor. B. Manufacturer's Warranty: Submit executed copy of IBRS 15 yr Commercial Limited Materials Warranty Warranty agreement from the date of final acceptance by the Owner. PART PRODUCTS 2.01 MANUFACTURER A. Acceptable Manufacturer: IB Roofing Systems, 2877 Chad Dr. Eugene, OR 97408: Toll Free: 800-426-1626 Fax: 541-610-1726, Email: technical@ibroo£com,Website: www.ibroof.com B. The IB MA-50-FF-IFS-W roofing system specified herein is the basis of design for all roofing assemblies. The structural deck,method of attachment and installation will be specific to each roofing assembly identified. 2.02 ROOF INSULATION/COVERBOARD/SEPARATORS SHEETS AND MEMBRANE MATERIALS A. 4' x 50', 1-1/2 to 2.0 lbs. density, ASTM C-578 Type X, 3/8 inch(9.5mm) extruded polystyrene fan-fold board(XPS), EPS 1/2" Fanfold. C. Field&Base Flashing Membrane: 50 mil Poly-Vinyl-Chloride(PVC)non- wicking polyester scrim reinforced thermoplastic membrane, conforming to the following standards: 1B Roof SN-stems 50 mil PVC Roofincy Alembrane Typical Propetlies Property 'Method Requirement 50 Afil Thickness'in: ; Breakiu=_Streneth,Af in.' MID 1fl] A-s t_y7�Z y Eloneation Z Brealt'Oai JID .kSTI! _XAM a .4 Retention of Properties a£terHeat seines :'o'^. ,1.,r D;'1-_ Tearins Strenath'lbf, nST:'•°Dsc _YID 4 ![p "ors"Temperature 9SI ?.^y_ Bend—C", "a. - Accelerated Weathenne " x - i Er. z-.icL` Linear Dimensional Chanse.'=e' 'J- MD `t'4ID Chanee in Wei=ht Afterlmmersion D=- ' intl"ateriv:a' `C , _4S t e ..; S '5J- StaticPunctureResistance -- Dvnamic Puncture Resistance Seam Stren=th --- = Weight(per S40sq.£t.) Solar Reflective I lermaIEmittance 11'3rr3nrk tyearsnon-prorateds 2.03 ROOFING ASSEMBLY SUMMARIES: A. Roof Deck: 1/2 in plywood. B. Substrate: Roof deck must be clean, dry, smooth, and structurally sound to receive the new roofing system. Drainage must be incorporated in the design to prevent ponding water. C. EPS 1/2" Fanfold is to be attached to the roof deck per the uplift design pressures determined by the Authority Having Jurisdiction(AHJ)/Design Professional as outlined by the 'International Building Code' (IBC) and ASCE-07. D. Field Membrane,Mechanically Attached over the surface of the specified components per the Roofing Manufacturers IBRS attachment requirements for the design pressure determined by the Authority Having Jurisdiction (AHJ) and the building code (whichever is more stringent). PART 3 EXECUTION 3.01 PROTECTION A. Protect building surfaces against damage from roofing work. Provide safety barriers and other protection devises as needed to protect property and people. 3.02 ROOF DRAINS A. Roof drains to connect to existing roof drain system. 3.03 ROOF SCUPPERS A. Exact type or style of scupper or roof drain will be determined once existing drains are freed from current roof system. 3.04 ROOF VENTS A. Roof vents to be installed per IBRS venting specifications for this type of roof system. Vents are supplied to vent the roofing system,not the structure itself. u RQQf yste/j]r SpecWriter/Mechanically Attached Details ROOF & MEMBRANE VENTS VENT CAP PLASTIC BUG SCREEN TARGET SHEET, PERIMETER WELDED x x 10° BASE OF VENT ATTACHED TO DECK INSULATION/SUBSTRATE OPENING IN DECK ROOF DECK NOTES: 1. ROOF VENT IS TO BE USED TO VENT ATTICS OR OCCUPIED SPACES AS RECOMMENDED BY THE FHA, ALL VENTING SHOULD INCORPORATE A BALANCED APPROACH SPLITTING THE INTAKE AND OUTTAKE AS FOLLOWS:50%, EVENLY SPACED AT THE EAVES,AND 50%AT THE RIDGE. 2. ROOF VENT CAN BE USED FOR BATH ROOM VENTS AND DRYER VENTS.THE ROOF VENT IS NOT INTENDED FOR HIGH HEAT SOURCES LIKE CHIMNEYS,STOVE PIPES, HEATER PIPES, ETC. PROJECT NAME: TITLE: MP-4 ROOF AND MEMBRANE VENTS APPROVED BY: PLOT DATE:11-08 SCALE: NTS DRAWN BY:A.SCHWAB REV:AS 11-08 65 Roo f System- SpecWriter/Mechanically Attached Details REGLET METAL FLASHING IB SEALANT IB WATER STOP D - ° ° ANCHOR @ 12" O.0 0 0 IB TERM BAR n D ° TWO PIECE REGLET METAL D ° D - ° 4' > IB BASE FLASHING . o. to p c IB FASTENER AND PLATE s' p @ 12" O.C. D ° . D . .. HOT AIR WELD 5 B FIELD MEMBRANE C It ° D Q � 4 d TERMINATION BAR OPTION: CAN BE USED IN LIEU OF SCREWS AND PLATES AT THE BASE OF THE WALL NOTES: 1. IB VERTIBOND BONDING ADHESIVE,APPLIED AT THE NOMINAL RATE OF 2 GALS. PER SQUARE(50%TO THE BACK OF THE SHEET AND 50%TO THE SUBSTRATE)MANDATORY ON BASE FLASHING HEIGHTS OF<18" (GREATER THAN), OPTIONAL ON HEIGHTS>18"(LESS THAN). 2. RETROFIT ROOFS REQUIRE ALL EXISTING BASE FLASHING TO BE REMOVED BEFORE INSTALLING IB MEM BRANE BASE FLASHINGS. PROJECT NAME: TITLE: M13-4 REGLET METAL FLASHING APPROVED BY: PLOT DATE:11-08 SCALE: NTS DRAWN BY:A.SCHWAB REV:AS 11-08 33 SpecWriter/Mechanically Attached Details : RoofSys f�►msj SINGLE LAYER OF FIRE SHEET EXISTING ROOF FIRE SHEET SLOPE FIRE RATING LAYERS SINGLE LAYER OF FIRE SHEET Fire Sheet 10 Recover: Main- N or Fire Sheet 50 0-3/4" tains exisiting 1 Fire Rating Fire Sheet 10 or New/Re-Roofs Fire Sheet 50 0-3/4"' Class'B' 1 o NOTES: 1. Fire Sheet is typically used over combustible roof decks (I.E.plywood/OSB/wood plank)in combination with 00 Single Ply to achieve either a Class`A or B'Fire SINGLE PLY Rating.*See graph for requirements. 2. Fire Ratings for IB Roof Systems can be found on the Underwriters Laboratory(UL)website:www.ul.com on no 3- Fire Sheets are to be attached to the roof deck with #12,#14,915, or XHD screws and insulation plates. FULL WIDTH SHEET OF FIRE SHEET Fastener spacing may vary depending on AHJ. DOUBLE LAYER OF FIRE SHEET ROOF DECK FIRE SHEET SLOPE FIRE RATING LAYERS • N DOUBLE COVERAGE FIRE Fire Sheet 10 0-3/4" Class'A' 2 SHEET LAYERS Fire Sheet 50 0-3/4" Class'A 2 NOTES: 1. Fire Sheet is typically used over combustible roof decks no (I.E. plywood/OSB/wood plank)in combination with Single Ply to achieve either a Class`A or'B'Fire N N; Rating.*See graph for requirements. 2. Fire Ratings for IB Roof Systems can be found on the Underwriters Laboratory(UL)website:www.ul.com SINGLE PLY 3. Fire Sheets are to be attached to the roof deck with 1/2 WIDTH SHEET OF FIRE SHEET #12,#14,#15, or XHD screws and insulation plates. FULL WIDTH SHEET OF IB FIRE SHEET Fastener spacing may vary depending on AHJ. PROJECT NAME: TITLE: MA-8 FIRE SHEETS APPROVED BY: PLOT DATE:11-08 SCALE: NTS DRAWN BY:A.SCHWAB REV.AS 11-08 16 SpecWriter I Mechanically Attached Details : Roo f ystem- CLAMPING RING DRAIN **OVERF OW DRAINS ARE THE SAME EXCEPT OR THE RESTRICTOR COLLAR INSTALL INTER-LOCKING METAL STRAINER AND BASKET OVER THE DRAIN TARGET SHEET INSTALL SCREWS AND PLATES @ 12"O.C.AROUND PERIMETER OF THE DRAIN TARGET SHEET INSTALLA 1"WIDE CONT BEAD OF WATER CUT-OFF SEAL- ANT BETWEEN THE BOTTOM OF THE DRAIN TARGET SHEET,AND THE DRAIN FLANGE OF THE METAL BOWL DRAIN TARGET SHEET TO EX- TENDAMIN.OF 12"FROM OUTER EDGE OF DRAIN RING 2" weld ROOF DRAIN,SECURED AS REQUIRED BY --- -- - --- DRAIN MANUFACTURER TO DECKING�— IB MEMBRANE DRAIN TARGET SHEET TO EXTEND A MIN.OF 2"BEYOND THE INNER FLANGE OF THE CLAMPING RING. DRAIN LINE - NOTES: 1. THIS DETAIL IS TO BE USED FOR NEW CONSTRUCTION RE-ROOF,AND RE-COVER APPLICATIONS. 2. RE-ROOF AND RE-COVER INSTALLATIONS: ENSURE THAT NO ASPHALTIC RESIDUE(I.E. PLASTIC ROOF CEMENT, STEEP SLOPE ROOFING ASPHALT,WET PATCH, ETC)COMES IN DIRECT CONTACT WITH THE PVC MEMBRANE. 3. RIGID ROOF INSULATION CAN BE SHAVED TO FORM A ROUND TAPERED SUMP FOR BETTER WATER-FLOW TO THE DRAIN RECEPTACLE. ALL NON-CLAMPING STYLE ROOF DRAINS ARE NOT COVERED UNDER ANY IB ROOF SYSTEM WARRANTY. PRE- APPROVAL OF ALTERNATE ROOF DRAINS MUST BE MADE FOR ANY`NDU OR'LABOR AND MATERIAL'WARRANTIES. PROJECT NAME: TITLE: MD-2 CLAMPING RING DRAIN APPROVED BY: PLOT DATE:11-08 SCALE: NTS DRAWN BY:A.SCHWAB REV:AS 11-08 56 COMMERCIAL LIMITED MATERIAL WARRANTY 15 YEAR A. What does this warranty cover? IB Roof Systems, hereafter known as(IBRS), proudly warrants that the IBRS membrane will be free from manufacturing defects and, so long as the membrane is correctly installed according to IBRS product installation specifications over a compatible substrate, IBRS further warrants that the IBRS membrane will not, due to manufacturing defects, deteriorate to the point of permitting leaks through the membrane material for the period specified below under normal conditions,subject to the other written terms and exclusions of this Warranty, or IBRS will provide a replacement IBRS membrane shipped to your building site. This Warranty does not become effective unless full payment of all invoices f Ilation and material has been received. This Warranty also requires you to notify IBRS of any leaks or del s provided in G below. Repair, alteration, removal or addition to an installed roof membrane without notice a S's prio itten authorization may render this Warranty null and void. lanmv B. How long does the coverage last? This is a fifteen (15) year Warranty that, subject to the other to nd conditions commg&s upon the original installation date. To transfer this warranty to a new owner go IBRS website ollgiWinstructions in the Warranty Transfer section. C. What will IBRS do? if the roof membrane leaks due to manufacturing defe S will p de a re a membrane shipped to you,the owner, at your building site.The aninot IBR or in however, ceed your original cost of the roof membrane materials and shipping. D. What this warranty does not cover? 1.Certain causes of damage to the membr a e date anufacture.IBRS does not cover membrane damage or failure cau by: a. Natural disaster,whi without li tion, fall or -blown debris,flood, hail,tornado, full gale, hurricane, lightning,fire, or any f Go b.Failure of substrate un incl colla ovement,deflection or failure of any portion of any structure; c.Vandalism or misuse, ing i destruction or harm,failure to adequately protect prior to or during install of war or ci obedie damage,excessive foot traffic or storage of materials on the roo Ili ts, or fai follow maintenance directions or unreasonable and excessive delay in taking corre acti this Misuse includes using the roof membrane for any purpose other Aftroof mem e; a ions durin aft including additions, penetrations, or substantial work performed on rough the roof su re not in a workmanlike manner and in substantial compliance with IBR ecifications and ins on instructions; e. mp products,materials,cleaners,chemicals or compounds,environmental fallout a I and the"Satisfactory"designation on the Chemical Compatibility Sheet in the "Approvals"section of th S ifications manual current as of the Installation Date; f.Animals,plants,in or other organisms, including algae, moss, fungi, lichens, mold, or mildew,on or beneath the membrane; g.Any buildin or component other than the IBRS membrane,including without limitation: Improper flashings gs;caulking,seams or any other connection, product or adhesive that ties or connects the membrane to any other product, component or structure, including penetrations through the membrane; improper ventilation; cracking, deterioration or failure of any other material, component or product other than the membrane itself. 2.Maintenance. IBRS does not warrant maintenance issues. The owner must take reasonable care in maintaining the roof,for example, cleaning gutters, roof drains and scuppers; keeping the roof free of debris;and if required, properly caulking any areas(such as reglets, pitchpans, etc)to maintain waterproofing. 3.Discoloration. IBRS does not warrant the appearance of the membrane, including stains,fading or discoloration or dirt retention, or odor. 4. Inspections. Inspection(s) (if any)of the installation or condition of a roof are solely for IBRS's information and convenience, and any such inspection(s)shall not create any additional duty, liability or warranty by IBRS,express or implied, nor any additional remedy for the Owner or any other person. 5.Workmanship. IBRS does not warrant or cover the workmanship of any installer. The designation of an IBRS installer as"approved" means the installer has received initial training related to IBRS products and in no way is intended to warrant workmanship in any particular case. 6. Removal or repair. IBRS does not provide labor or cover the cost to remove, dispose, re-install,construct, repair or maintain any product, improvement or structure except for the replacement of the IBRS membrane to the limited extent provided in C. E.REMEDIES LIMITED TO SHIPMENT OF NEW MEMBRANE. The remedy stated in C above is the SOLE AND EXCLUSIVE REMEDY for failure of the roof membrane described herein.IBRS SHALL UNDER NO CIRCUMSTANCES WHETHER FOR BREACH OF CONTRACT,WARRANTY RS'S NEGLIGENCE,STRICT LIABILITY IN TORT,OR OTHERWISE,BE LIABLE FOR INCIDENTAL OR EQUENTIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO DAMAGES TO ANY BUl ,ITS CONTENTS,AND ANY PERSON DUE TO ANY CAUSE,INCLUDING WITHOUT LIMITATION UCT FAILURE,LEAKS, MOISTURE,CONDENSATION,MOLD,ORGANISMS,OR ODORS,FIR TION O CONOMIC OR BUSINESS EXPECTATIONS,LOSS OF PROFITS,LOSS OF DATA,COS AP FACILITIES OR SERVICES,OR DOWNTIME COST. F. LIMITATIONS OF WARRANTY. 1. THIS WARRANTY STATES IBRS'S ENTIRE LIABILITY A PLACES ALL RaWOR WRITTEN WARRANTIES. ALL IMPLIED WARRANTIE ING IMPLIED WA OF MERCHANTABILITY AND FITNESS FOR A PARTIC E,A EREBY EXPR Y DISCLAIMED AND EXCLUDED. NO REPRESENTATIVE IS AUT ED TO TO AN GE WARRANTY. 2. This Warranty shall be considered void in ent tha repai t k is done on or through the roof membrane(i)without IBR ' rior w appr of the pr ork,and/or(ii)not in accord with the IB Roof Systems Specifica nual the date of roposed work. Asa condition of service under G below,the install BRS s e reasonable access to the roof during normal business hours.The Owner shall be responsibl st of I investigation to the extent defects are determined not to be covered by the Warranty. G. What to do in case of a lea Immediately call the original roo i hen RS a 26-1626 within five(5)days of discovering the problem. Failure to notify IBRS withi od hours at IBRS's sole discretion, render this Warranty null and void.Written notice de Iso be g en within thirty(30)days to: IB Roof Systems, 2877 Chad Drive, Eu R 97408. H. Application of Sta This Warranty is governe the the St a regon. Purchase of this product constitutes irrevocable consent t clusive ju 'ction a in s r federal courts in Multnomah or Lane County, Oregon in all dispute s IBRS arisin to he purchase, use or warranty of this product. Some states do not allow t xclusion or limi ciden consequential damages,or limitation or exclusion of implied warran so the above exc s and limitations may not apply to you. INSTALLATION DATE: APPROVED INSTALLER: OWNERS OR REP: JOB NAME: ADDRESS: IB Roof Systems, 2877 Chad Drive, Eugene OR 97408 ID#C ROOF SAMPLE LO WMOS (DRoofSystemsi Expect More. MIL Manufacturere PVC Membranes Since 1978 00i Title 24 Weathering Surface dey5 .. 9 Fb Compliant • 156%Thicker than industry standard for a longer lasting roof • Solarwise'"^finish maintains reflectivity and appearance • Superior UV stabilization formula resists harsh elements • Class-A fire rated to protect building and contents Reinforcement • Non-wicking reinforcement eliminates edge treatments Base Ply • Similar properties as weathering surface for stronger, more reliable seams 4�. why IB 50 Mil membrane is the Industr 's Best. SurpassingASTM Standards >Weathering Surface..................... 156 Thicker >Seam Strength.................. 247" More Reliable > V #iKii,*MiEN.f7f��IMf.H.s.. 26V - r IB Roof Systems Affiliated with: Se OOTAW CA All test results taken from the typical properties of IB Roof Systems PVC roofing membranes. Requirements were taken from ASTM D4434-96. 10 I DO5N0r REMOVE a CORRECTIONS REPORT "Q' Building Codes 293-1901 ANACORTES 8 Fire cones 293-1925 ❑ Public.Works 293-1920 The corrections listed below are hereby ordered and must be completed within days. ER/CONTRACTOR PERMIT NUMBER '1 ADDRESS � \ DATE ❑ NOT APPROVED FORCOVER NOT APPROVED FOR OCCUPANCY OR USE KI CORRECTIONS NEEDED ❑ STOP WORK � ?�C1Al \ b 51, f�%:-%A "Je"K< Q �+QCl IA]/* ►�t�0� l�hr2cs cs�. s yS1 Aft►-� o -t- b� c•.SZAo p^.�i . NIiii:4 .t,; 'ND CA cZaA ID 4C r-�.usz NOTIFY INSPECTION.OFFICE WHEN READY FOR REINSPECTION NR�r�»7tswo�.� 0�` . t' } Nor REMOVE CORRECTIONS REPORT Building codes 293-1901 ANACORTES Fire codes 293-1925 ., ❑ Public Works 293-1920 The corrections listed below are hereby ordered and must be completed within days. OWNERI CONTRACTOR PERMIT NUMBER ADDRESS DATE 0 NOTAPVED FOR COVER ❑ NOT AP: 4VED'FOR OCCUPANCY OR USE CORRElINS NEEDED ❑ STOP WORK ec\tvno -f-� caji N011FY-INSPECT11GU OFRIDE w: WHEN REAE*FOR`R€INSPECTION. R