Loading...
HomeMy WebLinkAboutPermit File BLD-2025-0009 12220 10th StreetFor inspections, please call (360) 293-1901 PARCEL: P55408 LEGAL DESCRIPTION: APPLICANT: Jennings, Milo 17199 Bennett Rd Mount Vernon, WA 98273 3608481533 OWNER: ANACORTES PUBLIC LIBRARY UNKNOWN ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 5982.00 $5,982.00 $5,982.00Total: FEES:Paid Due Building Permit Fee $125.25 $0.00 Plan Review Fee $81.41 $0.00 State Building Code Council fee $25.00 $0.00 $0.00Totals : REQUIRED INSPECTIONS Fire Alarm ELECTRICAL CONTRACTOR:COMMERCIAL ALARM/DETECTION INC 17199 Bennett Rd MOUNT VERNON, WA 98273 3608481533 License: COMMEAI948LO Expires: 11/19/2026 $231.66 BLD-2025-0009 FIRE ALARM ISSUED: EXPIRES: 01/15/2025 07/15/2026 PROJECT NAME: ANACORTES LIBRARY - YOUNG ADULT RENOVATION SITE ADDRESS: 1220 10TH ST ANACORTES Page 1 of 1Printed by : Cheri Gleichmann on: 05/13/2025 10:01 AM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ Description The Wheelock Eluxa horns, horn strobes, and strobes by Eaton feature an advanced power saving LED technology with a full range of low and high candela settings for indoor wall and ceiling-mount applications. Designed in sleek, modern enclosures, Eluxa’s aesthetically pleasing low profile will blend with the building‘s interior décor. High efficiency, LED technology Eaton’s high energy efficient technology leads the industry in lowest current draw for a combined high and low candela device, which reduces overall power consumption. As the first notification appliances in the industry to utilize LED as the light source, this breakthrough optical design, resulting in best-in-class efficiency, enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. This reduces installation and operating costs. All strobe models feature six candela settings: 15, 30, 75, 110, 135, 185 cd on wall models and 15, 30, 75, 110, 150, 177 cd on ceiling models. Low profile design and rich feature set With the industry’s smallest footprint, the Eluxa horns, horn strobes, and strobes are aesthetically pleasing to building owners as the low profile design does not detract from the interior decor. Eluxa is feature rich with 6 candela settings and 3 horn patterns (Continuous, T3, T3/T4) in 1 device, pre-wire/pre-test via mounting plate with hinged feature for ease-of-installation, single-gang design (wall models), and no tools needed for setting changes. The ELST strobe, ELHS horn strobe, and the ELHN horn are for 24V operation. ELHN is suitable for 12V applications. Approvals and synchronization Eaton’s Eluxa strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. The Eluxa notification appliances are listed under UL Standards 1971, 1638, and 464 and under CAN/ULC-S525 and CAN/ULC-S526. The appliances are Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the Eluxa product line has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to be compatible with Exceder LED3 and Wheelock RSS strobe-based products including the RSS, CH, E, EH, ET, ST, HS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Eluxa strobes in the same notification zone and field of view with any Wheelock RSS and Exceder LED3 strobe models. Eluxa horns, horn strobes, & strobes Technical Data TD450157EN Effective August 2022 Supersedes July 2022 ELHN, ELHS, ELST ELHNC, ELHSC, ELSTC 2 Technical Data TD450157EN Effective August 2022 Eluxa horns, horn strobes, & strobes EATON www.eaton.com Features • Energy efficient • LED technology provides industry’s lowest current draw • Fewer power supplies required, smaller wire gage, reduced wire runs • Low-profile design • One of the smallest, most compact single-gang designs • Sleek, modern aesthetics with no visible mounting screws • Special lettering available • 6 Field selectable settings in 1 device • Wall: 15, 30, 75, 110, 135, 185 cd • Ceiling: 15, 30, 75, 110, 150, 177 cd • 3 horn patterns • Continuous, T3, and T3/T4; Fire and CO signaling in 1 device • Sound pressure (Anechoic) dBA • Low 86, High 91 (for Continuous, T3, and T4) • Easy-to-install • Mounting plate included with all models: Convenient capture hinge allows installers to easily hold the device while fastening the single-mount screw in place. • Pre-wire/pre-test capability to check for wiring and ground faults prior to appliance installation • Finger slide switches--No tools needed for setting changes • IN/OUT screw terminals using #12 to #18 AWG wires • Mounting options include ELSBB, any single-gang backbox and to 4” square with adapter kit for wall models and LSPKBB-C backboxes and 4” square, 1 1/2” or 2 1/8”deep for ceiling • Strobe synchronization • Meet synchronizing standards with Wheelock’s DSM Sync Modules, PS Power Supplies or SAFEPATH products • Ability to mix xenon and LED strobes in the same field of view • Compliance • NFPA 72 2016 - 20 ms flash duration requirements • UL 1971, UL 1638, UL 464, ULC-S525, ULC-S526 • California State Fire Marshal (CSFM) • Factory Mutual (FM) • RoHS • FCC Part 15, ICES ote: N Please read these specifications and associated installation instruc-tions, before using, specifying, or installing this product. Visit Eaton.com/ Lifesafetynotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their “Regulated Voltage Range.” Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective strobe intensity based on UL 1971. Drawings Figure 1. Wall, horn strobe Figure 2. Ceiling, horn strobe Eluxa Horns Model Regulated Voltage Range VDC High dB Low dB ELHN/ELHNCELHN/ELHNC 8.0 - 17.516.0 - 33.0 0.0250.028 0.0200.021 Table 1. Horn ratings per UL/ULC Anechoic 3 Technical Data TD450157EN Effective August 2022 Eluxa horns, horn strobes, & strobes EATON www.eaton.com Table 4. Specification & Ordering Information Model Mounting Strobe Candela Red White Lettering Sync w/ DSM or Wheelock Power Supplies Horn strobes ELHSRELHSW ELHSR-A ELHSR-N ELHSW-AELHSW-ALELHSW-NELHSW-EVELHSRCELHSWCELHSWC-N WallWallWallWallWallWallWallWallCeilingCeiling Ceiling 15/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/185 15/30/75/110/135/185 15/30/75/110/135/185 15/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/150/17715/30/75/110/150/17715/30/75/110/150/177 X X X X X X XXX XX FIREFIRE AGENT No Lettering AGENTALERTNo LetteringEVACUATEFIREFIRENo lettering XXXXXXXXXXX Strobes ELSTRELSTW ELSTR-A ELSTR-AL ELSTW-AELSTW-ALELSTW-NELSTR-NELSTW-EVELSTRCELSTWCELSTRC-ALELSTWC-ALELSTWC-EV WallWallWallWallWallWallWallWallWallCeilingCeilingCeilingCeilingCeiling 15/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/135/18515/30/75/110/150/17715/30/75/110/150/17715/30/75/110/150/17715/30/75/110/150/17715/30/75/110/150/177 X X X X X X X X XX X X XX FIREFIRE AGENT ALERT AGENTALERT No LetteringNo LetteringEVACUATEFIREFIREALERTALERTEVACUATE XXXXXXXXXXXXXX Horns ELHNRELHNWELHNRCELHNWC Wall WallCeilingCeiling X X X X No LetteringNo LetteringNo LetteringNo Lettering XXXX Accessories ELSBB-RELSBB-WESB-KIT-RESB-KIT-WLSPKBB-CRLSPKBB-CW LED Backbox, wallLED Backbox, wallTrim Plate, wallTrim Plate, wallBackbox, ceilingBackbox, ceiling X X X X X X a RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b Regulated Voltage Range - VDC Table 2. Strobe ratings Eluxa Horn Strobes UL/ULC Max Current a at Anechoic High continuous 24VDC Model Regulated Voltage Range VDC 15 30 75 110 135 150 177 185 ELHSELHSC 16.0-33.016.0-33.0 0.0370.037 0.0460.046 0.0770.077 0.1090.109 0.146 0.146 0.208 0.208 Table 3. Code 3 horn strobe ratings UL/ULC Max Current a 24VDC Model Regulated Voltage Range VDC 15 30 75 110 135 150 177 185 ELSTELSTC 16.0-33.016.0-33.0 0.0220.022 0.0300.030 0.0600.060 0.0860.086 0.125 0.125 0.185 0.185 Eluxa Horn Strobes UL/ULC Max Current a at Anechoic Low continuous 24VDC Model Regulated Voltage Range VDC 15 30 75 110 135 150 177 185 ELHSELHSC 16.0-33.016.0-33.0 0.0300.030 0.0390.039 0.0700.070 0.1020.102 0.139 0.139 0.201 0.201 ote: N Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. © 2022 Eaton All Rights Reserved Printed in USA Publication No. TD450157EN August 2022 Eaton is a registered trademark. All other trademarks are property of their respective owners. Eluxa horns, horn strobes & strobes Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/Lifesafetynotification Technical Data TD450157EN Effective August 2022 Architects and Engineers Specifications The LED notification appliances shall be Wheelock® ELHS audible visual strobe appliances, ELST visual strobe appliances and ELHN audible appliances for wall and ceiling-mount applications with a low- profile design or approved equals. Special lettering, including AGENT, ALERT, EVACUATE, and no lettering, shall be available. The ELHS and ELST strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service and UL 1638 (Visible Signaling Devices. The ELHS and ELHN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All models shall meet the requirements of FCC Part 15 and ICES-003. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 16 to 33 VDC/VFWR. The ELHS audible strobe and ELST strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Light Emitting Diode (LED) as the light source with a rugged Lexan® lens. The appliances shall be of low current design. The LED strobe flash duration shall be 20 ms. Where Multi-Candela appliances are specified, the strobe intensity shall have 6 field selectable settings at 15, 30, 75, 110, 135 and 185 candela for wall mount applications and 15, 30, 75, 110, 150 and 177 for ceiling applications. The selector switch for selecting the candela shall be tamper resistant. Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a choice of three (3) horn patterns (high & low output): Continuous, T3, and T3/T4 for fire (T3) and CO (T4) signaling. The ELHS audible strobe, ELST strobe, and ELHN audible shall include a hinged mounting plate. Mounting options shall include LED backboxes, single-gang backbox and to 4” square with adapter kit for wall-mount models and LED Ceiling backboxes and 4” square, 1 1/2” or 2 1/8”deep for ceiling models. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. The ELHS, ELHN and ELST wall models shall have a low profile measuring 4.79”H x 2.76”W x 1.18”D. The ELHSC, ELHNC and ELSTC ceiling models shall have a low profile measuring 6.27” Diameter with 1.69”D. When synchronization is required, the appliance shall be compatible with Wheelock®’s DSM Sync Modules, PS Power Supplies, SAFEPATH products or other manufacturer’s panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® patented sync protocol. NFPA 72 2016, UL 1971, UL, 1638, UL 464 ULC-S525-16, ULC-S526-16, CSFM, FM, FCC, RoHS, ICES WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Table 5. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating Weight Wall: 0.35 lbs; Ceiling: 0.55 lbs Lens Light Emitting Diode (LED) in a rugged Lexan lens Dimensions Wall: 4.79”H x 2.76” W x 1.18” D, Trimplate: 5.25” H x 4.58” W x 0.32” D; Ceiling: 6.27” Diameter x 1.69” D Operating Temperature Indoor: 32°F to 122°F (0°C to 50°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only)Mounting plate included with all models. ELHS and ELST are for wall-mount applications only. ELHN can be used for wall and ceiling-mount applications. Wall mounting: Single-gang, ELSBB backboxes or to 4” square with adapter kit. ELHN can be used for wall and ceiling-mount applications. ELHSC and ELSTC are for ceiling mount applications only. The ELHNC can also be used for wall-mount applications. Ceiling mounting: LSPKBB-C backboxes or to 4” square, 1 1/2” or 2 1/8” Wire Connections #12 through #18 AWG Power & General Operating voltage 12 VDC/VFWR: 8 - 17.5 VDC/VFWR; 24 VDC/VFWR: 16 - 33 VDC/VFWR (12 VDC ELHN/ELHNC models only) Strobe Output Rating UL 1971, UL 1638, ULC S526: Selectable 15, 30, 75, 110, 135, 185 candela output for wall models; Selectable 15, 30, 75, 110, 150, 177 candela output for ceiling models Synchronization Models Strobes can be synchronized with Wheelock’s DSM Sync Modules, PS Power Supplies or SAFEPATH products, using Wheelock patented sync protocol NON-FICTION / REFERENCE 136 MEETING 101 STOR 101A LOBBY 100 STOR 101B VEST 100A MEN 103 102 STOR 106 STOR 108 SERVER 109 TECH SERV 110 OFFICE 107 WOMEN 104 FRIENDS 105 OFFICE 115 DROP 116 WORK 122 MAIN HALL 132 STAIR 1 133 YOUNG ADULTS 134 STUDY 137 STUDY 138 STUDY 139 STUDY 140 CHILDRENS AREA 130 STAIR 3 131STORY 129 TABLES 129A STOR 129B ELEC 124 STAIR 2 118 TOILET 120CUST 119 TOILET 121 TOILET 128 ELEV 123 OFFICE 126 WORK 127 ELEV EQUIP 125 VOLUNTEER 112 IT DATA 114 DROP 113 ENTRY 117 COPY 135 MECH 111 ANN75 F 97:m025 F 97:m124 R 97:s80 F 97:m123 97:s018 97:s019 R 97:s079 75 F 97:m027 75 110 30 EOL NA C 2 2C NA C 2 2C NAC 2 2C NA C 2 2C NA C 2 2C NAC 2 4CNAC 24C NAC 2 2C 15 110 15 30 NA C 2 2C HR TO FACP WP 75 15 F 97:m028 EOL 15 15 110 15 15 WP 75 F 97:m034 F 97:m033 F 97:m032 F 97:m030 WP 75 110 110 15 15 15 15 WP 75 110 97:s001 97:s002 97:s003 97:s004 97:s00797:s00897:s00997:s010 97:s011 97:s012 97:s02397:s02297:s021 97:s02497:s02597:s026 97:s027 97:s028 97:s03097:s029 97:s020 97:s031 97:s04497:s043 97:s046 97:s047 97:s048 97:s017 97:s016 97:s015 97:s014 97:s013 97:s040 97:s045 97:s038 97:s041 97:s035 97:s034 97:s033 97:s032 97:s042 97:s039 97:s036 97:s037R 97:s078 R 97:s076 R 97:s089 R 97:s074 R 97:s077 R 97:s073 R 97:s072 R 97:s071 R 97:s069 R 97:s070 R 97:s068 R 97:s066 EOL 110 15 15 15 R 97:s067 110 15 15 FA C P 15 15 15 75 54 9 6 AE S B R 97:m051 R 97:m050 B RC SLC SLC SLC S L C SL C SL C SLC SL C SL C SLC SLC SL C S L C SL C SLC SLCSLC SL C S L C F 97:m026 SL C SL C SLC SLC SLC SLC SL C SLC SL C SL C SLC SLC SL C SL C SL C SL C SLC SL C SLC SLC SLCSLCSLC SLC SLC SL C S L C SL C SL C SL C SLC SL C SL C SL C SL C SL C N A C 8 4C NAC 8 2 C NA C 8 2 C NA C 8 2C NA C 8 2C NAC 8 2C NA C 8 2C N A C 8 2C NAC 84C NAC 8 4 C NA C 8 4 C NAC 8 2C NA C 8 2C NAC 8 2C NAC 8 2C NAC 8 2C NA C 3 2C NA C 3 2 C NA C 3 2C NAC 3 2C NAC 3 2C N A C 3 2C NAC 3 2C NA C 3 2 C N A C 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NAC 3 2C NA C 3 2C NA C 3 2C N A C 3 2 C NA C 3 2CNAC 32CNAC 3 2 C EOL S L C SL C SL C SL C SLC SLC SLC SLC SL C S L C SLC SLC SLC SLC SLC SL C SLC SLC SLC SLC SLC SLC SLC S L C SL C SLCF 97:m023 SLC SL C SL C SLC SLC SLC SLC SLC SL C SLC SLC SLC SLC SLC SL C SL C SLC SLC SLC SLC SLC SL C S L C SL C SLC SLC SLC SLC SLC SL C SL C SL C SL C SL C SL C SL C SL C SL C SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SL C SL C SLC SL C SL C SLC SLC SLC SLC SLC SLC SLC SLCSLCSLC SLC SLCSLC SLC SLCSLCSLC SLCSLC SLCSLCSLCSLC SLC SL C SL C SL C SLC SLC SLC SLC SL C SL C SLC NA C 8 4C NAC 8 4C NAC 8 4C NAC 8 4C NAC 8 4C NAC 8 4C R 97:s065 NA C 3 4 C NA C 3 4C NA C 3 4C SL C S L C S L C SLC SL C SL C SL C SL C SL C S L C SL C SL C SL C SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLCSLC SL C SL C SL C SL C SLC SL C SL C SL C SL C SL C HR TO FACP NAC 7 4C NA C 7 2C NA C 7 2C NA C 7 2C NAC 7 2C NA C 7 2C SLC SLCSLC 75 NAC 7 2CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72CNAC 7 2C NAC 7 2CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72CNAC 72C NAC 3 4C NA C 3 4C NAC 3 4C T 97:m020 WF97:m024 NA C 7 2C HR TO FACP NAC 2 2C NAC 2 2C NAC 2 2C NAC 82CNAC 82CNAC 82CNAC 82CNAC 82CNAC 82CNAC 82C N A C 8 4C NAC 8 4C NAC 8 4C NA C 2 2C 97:s101 97:s100 SLC S L C F 97:m031 SLC SLC SLC SLC SLC SLC SL C SL C SL C SLC SLC SL C SLC SLC SLC SLC SLC SLC SLC SLC RC SBUS SBUS TO FACP PIV ID C ID C ID C ID C ID C IDC P 97:m021 12'-0" AFF 13'-6" AFF 13'-6" AFF 21'-0" AFF FIBER ROOM 97:s102 R/E 75 SLC SL C S L C R 30 SLC SLC SLC SLC 30 NAC 3 4C NAC 3 4C N N N YOUNG ADULT RENOVATION AREA OF WORK J NA C 3 4C NA C 3 4 C -N81 -N82 -N8 3 -N84 -N8 5-N86 -N87 -N8 8 -N8 9 -N8 10 -N8 11 -N8 13 -N812 -N31 -N3 2 -N33 -N34 -N3 5 -N3 6 -N3 7 -N38 -N39 -N7 2 -N310 -N311 110 -N21 -N2 2 -N2 3 -N2 4 -N2 5 -N2 6 -N27 -N71 -N73 -N74 -N7 5 -N7 6 -N77 -N7 8 -N79-N710 -N711 R/E M 97:m105 M 97:m103 M 97:m104 M 97:m102 M 97:m100 M 97:m101 SLC SL C SL C SL C SL C M M M R97:m019 R97:m017 R97:m018 M97:m016 SLC SLC SLC SLC SLC SLC SLC SL C 97:s006 97:s005 F97:m029 SLC SLC SLC SLC SLC SLC NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C NAC 7 2C Act u a t e C o m m o n A l a r m S i g n a l I n d i c a t o r Manual Fire Alarm Station SYSTEM INPUTS SYSTEM OUTPUTS ANNUNCIATION Smoke Detector - Elevator Equipment Room Waterflow - Riser Room Tampers - Sprinkler Room Smoke Detector - Elevator Lobby - Floor 1 Fire Alarm AC Power Failure Fire Alarm System Low Battery Open Circuit Ground Fault Notification Appliance Circuit Short Act u a t e A u d i b l e A l a r m S i g n a l Act u a t e C o m m o n S u p e r v i s o r y S i g n a l I n d i c a t o r Act u a t e A u d i b l e S u p e r v i s o r y S i g n a l Act u a t e C o m m o n T r o u b l e S i g n a l I n d i c a t o r Act u a t e A u d i b l e C o m m o n T r o u b l e S i g n a l Dis p l a y C h a n g e o f S t a t u s Tra n s m i t F i r e A l a r m S i g n a l t o S u p e r v i s i n g S t a t i o n Tra n s m i t S u p e r v i s o r y S i g n a l t o S u p e r v i s i n g S t a t i o n Tra n s m i t T r o u b l e S i g n a l t o S u p e r v i s i n g S t a t i o n Ini t i a t e P r i m a r y L e v e l E l e v a t o r R e c a l l Ini t i a t e A l t e r n a t e L e v e l E l e v a t o r R e c a l l CONTROL UNIT Act u a t e G r o u n d L e v e l E x t e r i o r N o t i f i c a t i o n S i g n a l s 1 3 4 5 6 7 9 11 12 A B C D E F G H I J K L M N A B C D E F G H I J K L M N ICATION NOTIF- CONTROL FIRE SAFETY Act u a t e I n t e r i o r N o t i f i c a t i o n S i g n a l s Smoke Detector - Riser Room 2 1 3 4 5 6 7 2 Smoke Detectors - Elevator Lobby - Floor 2 8 10 9 11 12 8 10 13 13 Duct Smoke Detector HV A C U n i t - F a n S h u t d o w n O O NN FIRST FLOOR PLAN SCALE: 1/8" = 1'-0" SCOPE OF WORK COMMERCIAL ALARM & DETECTION WILL EXPAND EXISTING FIRE ALARM SYSTEM BY INSTALLING NEW & RELOCATING EXISTING AUDIBLE, VISIBLE, AND INPUT DEVICES. THE EXISTING SYSTEM UTILIZES WIRELESS RADIO TRANSMISSION FOR REMOTE EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. THIS IS ACCOMPLISHED THROUGH THE USE OF TWO-WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON FREQUENCY 465.9875 MHZ LICENSED TO SECURITAS TECHNOLOGY WITH THE FCC. THIS UNIT COMMUNICATES TO CENTRAL STATION THROUGH A MINIMUM OF TWO GOOD PATHS WITH A NETCON OF 5 OR LESS. THESE PATHS CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING FINAL INSPECTION. PHONE : EMAIL : ANACORTES PUBLIC LIBRARY 1220 10th ST Anacortes, WA 98221 24-151 Regency NW Construction Inc PO BOX 6429 BELLEVUE, WA 98008 Kim Bennett (425) 883-1301 FA-1 City of Anacortes and L&I AUTHORITIES HAVING JURISDICTION : kim.bennett@regencynw.com SIGNATURE NAME CERTIFICATION NO. BERNIE STEBAR NICET IV #116393 COMMERCIAL ALARM & DETECTION INC. 17199 BENNETT ROAD MT VERNON, WA 98273 LICENSE # COMMEAI948LO PHONE: (360) 848-1533 PAGE NUMBER JOB NUMBER OF APPROVAL REASON FOR REVISIONDATENO. CONTRACT INFORMATION CHECKED BY B. STEBAR DATEDRAWN BY M. JENNINGS REVISIONS JOB INFORMATION DOCUMENT NAME EXPIRATION DATE 4/1/27 SHEET LIST FLOOR PLAN FA-1 VICINITY MAP DEVICE LEGEND CABLE CODES SLC POINT LIST FIRE ALARM MATRIX FLOOR PLAN CONTINUED FA-2 SLC POINT LIST CONTINUED RISER DIAGRAM FA-3 BATTERY CALCULATIONS 01/10/2025 PROJECT MANAGER: 31 Device & Wiring Notes: All device wiring to be Class B configuration and not to exceed maximum distances per wire gauge (16 AWG = 4900 Ft). All audible notification devices to be set to a three pulse temporal pattern. All audible and visual notification devices serving the same area are to be synchronized. DESIGN CRITERIA DESIGNED PER IFC - 2021 INSTALLED PER NFPA 72 - 2019 INSTALLED PER NFPA 70 - 2023 DEVICE LEGEND SYMBOL TYPE MANUFACTURER MODEL CANDELA MOUNTING STATUS COUNT FACP AES ANN 5496 F R D B R RC M R WP CABLE CODES CODE FUNCTION DESCRIPTION NECTYPE CABLE ROUTING NN VICINITY MAP SCALE: NTS FIRE ALARM MATRIX OF OPERATIONS SCALE: NTS NOTES: All devices are existing unless otherwise noted. N:New device R: Relocate existing device R/E: Remove existing device 97:M016 ELEVATOR SHAFT TAMPER 97:M017 SECONDARY RECALL RELAY 97:M018 PRIMARY RECALL RELAY 97:M019 FLASHING HAT RELAY 97:M020 WET SYSTEM TAMPER 97:M021 RISER PIV NORTH SIDE 97:M023 RISER ROOM EXIT 97:M024 WET SYSTEM WATERFLOW 97:M025 MEETING 101 EXIT SOUTH 97:M026 MEETING 101 NORTH EAST EXIT 97:M027 MAIN ENTRY PULL 97:M028 EAST MAIN SIDE ENTRY 97:M029 NORTH EAST EXIT TEENS AREA 97:M030 NORTH EAST STAIRCASE EXIT 97:M031 CHILDRENS AREA NORTH EAST EXIT 97:M032 FACP ROOM NORTH EXIT 97:M033 NORTH STAIRCASE EXIT 97:M034 NORTH EMPLOYEE ENTRANCE/EXIT 97:M050 NON FICTION NORTH BEAM DET 97:M051 NON FICTION SOUTH BEAM DETECTOR 97:M100 IT ROOM SUPPRESSION RELEASE ALARM 97:M101 IT ROOM SUPPRESSION RELEASE SUPERVISORY 97:M102 IT ROOM SUPPRESSION RELEASE TROUBLE 97:M103 FIBER ROOM SUPPRESSION RELEASE ALARM 97:M104 FIBER ROOM SUPPRESSION RELEASE SUPERVISORY 97:M105 FIBER ROOM SUPPRESSION RELEASE TROUBLE 97:M123 MEETING ROOM WEST EXIT 97:M124 MEETING ROOM WEST EXIT 97:S001 EAST STUDY ROOM 140 97:S002 EAST STUDY ROOM 139 97:S003 EAST STUDY ROOM 138 97:S004 EAST STUDY ROOM 137 97:S005 TEENS BOOK AREA EAST 97:S006 CENTER MAIN AREA 97:S007 CENTER MAIN AREA 97:S008 CENTER MAIN AREA 97:S009 CENTER MAIN AREA 97:S010 CENTER MAIN AREA 97:S011 COPY ROOM WEST 135 97:S012 WEST NON FICTION AREA 97:S013 THEFT SCANNERS ENTRANCE 97:S014 LOBBY MAIN ENTRY DOORWAY 97:S015 MAIN LOBBY SKYLIGHT 97:S016 MAIN ENTRY BREEZWAY 97:S017 MAIN ENTRY BREEZWAY 97:S018 MEETING ROOM MAIN ENTRY 101 97:S019 MEETING ROOM MAIN ENTRY 101 97:S020 CHILDRENS AREA ENTRY FROM SOUTH 97:S021 CHILDRENS AREA SOUTH 97:S022 CHILDREN AREA CENTER 97:S023 CHILDRENS AREA EAST 97:S024 CHILDRENS AREA EAST CENTER 97:S025 CHILDRENS AREA CENTER OF ROOM 97:S026 CHILDRENS AREA WEST CENTER 97:S027 CHILDRENS AREA NORTH EAST CORNER 97:S028 CHILDRENS AREA NORTH EAST 97:S029 NORTH EAST STAIRCASE 97:S030 NORTHEAST STAIR CASE MID LANDING 97:S031 CHILDRENS AREA STORY ROOM 129 97:S032 CHILDRENS AREA RECEPTION 97:S033 NORTH EAST MIDDLE OFFICE 126 97:S034 ELEVATOR MACHINE ROOM 97:S035 1ST REAR ELEVATOR LOBBY 97:S036 1ST FRONT ELEVATOR LOBBY 97:S037 WORK STATION 122 NORTH MIDDLE 97:S038 WORK STATION 122 NORTH MIDDLE 97:S039 FRIENDS ROOM OFF MAIN ENTRY NORTH 106 97:S040 OFFICE 115 NORTH WEST MIDDLE 97:S041 OPEN OFFICE NORTH 97:S042 REAR STAFF ENTRY HALL NORTH 97:S043 NORTH MIDDLE STAIR CASE 97:S044 NORTH MIDDLE STAIR CASE MID LANDING 97:S045 VOLUNTEER 112 HALL 97:S046 TECH SERVER 110 NORTH WEST 97:S047 TECH SERVER 110 NORTH WEST 97:S048 OFFICE 107 NORTH WEST CORNER 97:S065 STORAGE CLOSET 129A 97:S066 STORAGE ROOM 129B 97:S067 RESTROOM ROOM 128 97:S068 FACP/ELECTRICAL ROOM 97:S069 RESTROOM 120 97:S070 RESTROOM 121 97:S071 CUSTODIAL ROOM 119 97:S072 MACHINE ROOM 111 97:S073 STORAGE ROOM 106 97:S074 STORAGE ROOM 108 97:S076 WOMENS RESTROOM 104 97:S077 MENS RESTROOM 103 97:S078 CUSTODIAN ROOM 102 97:S079 STORAGE 101A 97:S080 STORAGE 101B 97:S089 IT CLOSET IN OFFICE AREA ADMIN 97:S100 IT DATA 114 97:S101 DROP 113 97:S102 FIBER ROOM SLC POINT LIST POINT NUMBER LABEL CITY OF ANACORTES FIRE DEPARTMENT APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT#:________________________ ADDRESS:_______________________ APPROVED BY:___________________ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. BLD-2025-0009 1220 10th St OUTDOOR MECHANICAL 218 MECH BOILER 216 DECK 217 STAFF 215 TOILET 207 WORK 206 SHOWER 208 STOR 212OFFICE 214 HALL 210 ADMINISTRATION 203 ELEV 123COMM 204 OFFICE 211 OFFICE 213 ELEC 205 FICTION 201 STAIR 3 131 MAIN HALL BELOW 132 STAIR 1 BELOW 133 BROWSING 200 CL 209 STAIR 2 118 TOILET 202 R 97:m054 RC 15 F 97:m035 15 15 EOL 97:s054 BR 97:m053 RC 110 75 15 15 75 WP 75 97:s04997:s05097:s05197:s05297:s053 97:s05797:s059 97:s060 97:s058 97:s061 97:s056 97:s055 97:s063 97:s062 R 97:s084 R 97:s082 R 97:s086 R 97:s081 R 97:s088 R 97:s085 15 15 F97:m036 15 15 15 15 15 15 15 R 97:s083 110 F 97:m037 RC SLC SL C SL C R 97:m052 B B 75 EOL LOCATED ABOVE CEILING IN ROOM "FRIENDS 105" ON FIRST FLOOR NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2 C NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2C NAC 9 2C N A C 9 2C NA C 9 2C NAC 9 2C NAC 9 2C NA C 9 2 C N A C 4 2C NA C 4 4C NA C 4 4C NA C 4 4C NAC 4 4C NA C 4 4C NA C 4 4C NA C 4 4C NA C 4 4 C NA C 4 4C NAC 44CNAC 44CNAC 44CNAC 44C NAC 4 4 C NAC 4 2C NAC 4 2C NAC 4 2C NAC 4 2C NAC 4 2C NAC 4 2C NA C 4 2C NAC 4 2C NAC 4 2C NAC 4 2C NAC 4 2C NAC 4 2C NA C 4 2C NA C 4 2C NA C 4 2C NAC 9 2C HR TO FACP 97:s087 SLC SLCSLC SLC SL C SL C HR TO FACP SLC SLC SLC SLC SLC SLC SL C SL C SL C SL C SL C SL C SL C SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLCSLCSLCSLCSLCSLCSLCSLCSLCSLCSLC SLC SL C S L C SLC SL C SL C SL C SL C SL C SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLC SLCSLCSLCSLCSLCSLCSLCSLCSLCSLCSLCSLC SLC SLC SLC SL C SLC SL C SL C SL C SL C SL C SLC SLC S L C SLCSLC SLC SL C S L C SL C SL C SL C SL C SL C SL C S L C SLC SLCSLCSLC SL C SL C SLCSLC SLC D 97:s120 SLC SLC CONNECTED TO97:s039 IN ROOM "FRIENDS 105" 97:s090 9'-6" AFF 9'-6" AFF 12'-0" AFF 12'-0" AFF 21'-0" AFF 21'-0" AFF -N91 -N9 2 -N93 -N9 4 -N9 5 -N96 -N97 -N9 8 -N99 -N9 10 -N9 12 -N9 11 -N41 -N4 2 -N45 -N46 -N4 7 -N48 -N4 3 -N4 4 R 97:m055 NN SECOND FLOOR PLAN SCALE: 1/8" = 1'-0" SCOPE OF WORK COMMERCIAL ALARM & DETECTION WILL EXPAND EXISTING FIRE ALARM SYSTEM BY INSTALLING NEW & RELOCATING EXISTING AUDIBLE, VISIBLE, AND INPUT DEVICES. THE EXISTING SYSTEM UTILIZES WIRELESS RADIO TRANSMISSION FOR REMOTE EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. THIS IS ACCOMPLISHED THROUGH THE USE OF TWO-WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON FREQUENCY 465.9875 MHZ LICENSED TO SECURITAS TECHNOLOGY WITH THE FCC. THIS UNIT COMMUNICATES TO CENTRAL STATION THROUGH A MINIMUM OF TWO GOOD PATHS WITH A NETCON OF 5 OR LESS. THESE PATHS CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING FINAL INSPECTION. PHONE : EMAIL : ANACORTES PUBLIC LIBRARY 1220 10th ST Anacortes, WA 98221 24-151 Regency NW Construction Inc PO BOX 6429 BELLEVUE, WA 98008 Kim Bennett (425) 883-1301 FA-2 City of Anacortes and L&I AUTHORITIES HAVING JURISDICTION : kim.bennett@regencynw.com SIGNATURE NAME CERTIFICATION NO. BERNIE STEBAR NICET IV #116393 COMMERCIAL ALARM & DETECTION INC. 17199 BENNETT ROAD MT VERNON, WA 98273 LICENSE # COMMEAI948LO PHONE: (360) 848-1533 PAGE NUMBER JOB NUMBER OF APPROVAL REASON FOR REVISIONDATENO. CONTRACT INFORMATION CHECKED BY B. STEBAR DATEDRAWN BY M. JENNINGS REVISIONS JOB INFORMATION DOCUMENT NAME EXPIRATION DATE 4/1/27 SHEET LIST FLOOR PLAN FA-1 VICINITY MAP DEVICE LEGEND CABLE CODES SLC POINT LIST FIRE ALARM MATRIX FLOOR PLAN CONTINUED FA-2 SLC POINT LIST CONTINUED RISER DIAGRAM FA-3 BATTERY CALCULATIONS 01/10/2025 PROJECT MANAGER: 32 Device & Wiring Notes: All device wiring to be Class B configuration and not to exceed maximum distances per wire gauge (16 AWG = 4900 Ft). All audible notification devices to be set to a three pulse temporal pattern. All audible and visual notification devices serving the same area are to be synchronized. DESIGN CRITERIA DESIGNED PER IFC - 2021 INSTALLED PER NFPA 72 - 2019 INSTALLED PER NFPA 70 - 2023 SLC POINT LIST POINT NUMBER LABEL 97:M035 NORTH EAST STAIR 3 PULL 97:M036 STAIR 2 NORTH 97:M037 TOP OF MAIN STAIR CASE 97:M052 TOP OF STAIR 1 BEAM DET 97:M053 SOUTH FICTION BEAM DET 97:M054 NORTH FICTION BEAM DET 97:M055 HVAC SHUT DOWN 97:S049 FICTION CORRIDOR 97:S050 FICTION CORRIDOR 97:S051 FICTION CORRIDOR 97:S052 FICTION CORRIDOR 97:S053 SECOND FLOOR FRONT ELEVATOR LOBBY 97:S054 STAIR 3 NORTH EAST 97:S055 2ND FLOOR REAR ELEVATOR LOBBY 97:S056 ADMIN RECEPTION 97:S057 ADMIN OFFICE 211 97:S058 ADMIN 210 HALLWAY 97:S059 ADMIN OFFICE 213 97:S060 ADMIN OFFICE 214 97:S061 ADMIN WORK ROOM 206 97:S062 TOP OF STAIR 2 97:S063 ADMIN WORK ROOM 203 97:S081 RESTROOM 202 97:S082 RESTROOM 207 97:S083 SHOWER 208 97:S084 STAFF BREAKROOM 215 97:S085 MACHANICAL/BOILER ROOM 216 97:S086 STORAGE 212 97:S087 COMM ROOM 204 NEXT TO ELEVATOR 97:S088 ELECTRICAL ROOM 205 97:S090 TOP OF ELEVATOR SHAFT 97:S120 DUCT DETECTOR ABOVE FRIENDS ROOM DE D I C A T E D 1 2 0 V A C CI R C U I T ( B Y O T H E R S ) SLC LOOP 1 DEVICES: (97:s001-159, 97:m001-159) SEE POINT LISTING TWO EXISTING 12V-18AH BATTERIES FACP (SK-6820) LOCATED IN ELEC 124 6860 REMOTE ANNUNCIATOR LOCATED IN LOBBY ENTRY NAC 4 NAC 2 NAC 3 NAC 1 NAC 6 NAC 5 UNUSED UNUSED J1 RESET SWITCH Tr a n s m i t - T X Re c i e v e - R X Wa i t - W A St a t u s - A L M J4, Antenna Cut/Trouble Output Form C Relay, Fail Secure Contact Rating: 24vdc, 1a Resistive Tr a n s c e i v e r +BAT-16.5VAC Z4 Z3 Z2 Z1 G G Accessory & Programmer Port NOTE: ALL 7707P resistors 2.2k Ohm PHONE LINES TROUBLE RELAY AES RADIO (7707P-88-ULP-M) LOCATED BY FACP RELAYS Z6 Z5 G Z8 Z7 G SUPERVISORY ALARM RELAY FIRE ALARM RELAY EXISTING 12V-12AH BATTERY 16.5VAC, 40VA Transformer 7794A 2.0 IntelliPro 5496: m01/AUX 1 LOCATED IN ELEC 124 NAC 9 NAC 8 NAC 10 NAC 7 04 SMOKE DAMPER RELAY AUX 4 AUX 3 AUX 2 AUX 1 SBUS BATTERY TWO 12V-7AH BATTERIES SBUS TO FACP AUX POWER FOR DUCT DETECTORS & BEAM DETECTORS SBUS 110 15 110 30 75 75 75 15 15 15 110 15 110 15 30 75 110 75 15 110 110 75 15 15 15 110 110 15 15 15 WP 75 15 75 15 15 WP 75 110 15 15 110 30 15 15 WP 75 15 15 WP 7515 15 15 15 15 15 15 15 15 15 15 WP 7575 -N71-N72-N73-N74-N75-N76-N77-N78-N79-N711 -N81-N82-N8 3-N8 4-N8 5-N8 6-N8 7-N88-N8 9-N8 10-N8 11-N8 12-N813 -N9 1-N9 2-N9 3-N9 4-N9 5-N96-N97-N9 8-N9 9-N9 10-N9 11-N912 -N21 -N22 -N2 3 -N24 -N25 -N26 -N27 -N31 -N32 -N3 3 -N34 -N35 -N36 -N37 -N38 -N39 -N310 -N41 -N42 -N43 -N44 -N45 -N46 -N47 -N48 75 -N311 NEW NEW NEW 30 -N710 SCOPE OF WORK COMMERCIAL ALARM & DETECTION WILL EXPAND EXISTING FIRE ALARM SYSTEM BY INSTALLING NEW & RELOCATING EXISTING AUDIBLE, VISIBLE, AND INPUT DEVICES. THE EXISTING SYSTEM UTILIZES WIRELESS RADIO TRANSMISSION FOR REMOTE EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. THIS IS ACCOMPLISHED THROUGH THE USE OF TWO-WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON FREQUENCY 465.9875 MHZ LICENSED TO SECURITAS TECHNOLOGY WITH THE FCC. THIS UNIT COMMUNICATES TO CENTRAL STATION THROUGH A MINIMUM OF TWO GOOD PATHS WITH A NETCON OF 5 OR LESS. THESE PATHS CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING FINAL INSPECTION. PHONE : EMAIL : ANACORTES PUBLIC LIBRARY 1220 10th ST Anacortes, WA 98221 24-151 Regency NW Construction Inc PO BOX 6429 BELLEVUE, WA 98008 Kim Bennett (425) 883-1301 FA-3 City of Anacortes and L&I AUTHORITIES HAVING JURISDICTION : kim.bennett@regencynw.com SIGNATURE NAME CERTIFICATION NO. BERNIE STEBAR NICET IV #116393 COMMERCIAL ALARM & DETECTION INC. 17199 BENNETT ROAD MT VERNON, WA 98273 LICENSE # COMMEAI948LO PHONE: (360) 848-1533 PAGE NUMBER JOB NUMBER OF APPROVAL REASON FOR REVISIONDATENO. CONTRACT INFORMATION CHECKED BY B. STEBAR DATEDRAWN BY M. JENNINGS REVISIONS JOB INFORMATION DOCUMENT NAME EXPIRATION DATE 4/1/27 SHEET LIST FLOOR PLAN FA-1 VICINITY MAP DEVICE LEGEND CABLE CODES SLC POINT LIST FIRE ALARM MATRIX FLOOR PLAN CONTINUED FA-2 SLC POINT LIST CONTINUED RISER DIAGRAM FA-3 BATTERY CALCULATIONS 01/10/2025 PROJECT MANAGER: 33 Device & Wiring Notes: All device wiring to be Class B configuration and not to exceed maximum distances per wire gauge (16 AWG = 4900 Ft). All audible notification devices to be set to a three pulse temporal pattern. All audible and visual notification devices serving the same area are to be synchronized. DESIGN CRITERIA DESIGNED PER IFC - 2021 INSTALLED PER NFPA 72 - 2019 INSTALLED PER NFPA 70 - 2023 FIRE ALARM RISER DETAIL SCALE: NTS SK-6820 BATTERY & EOL CALCULATIONS BATTERIES USED : (2) 12v-18AH 5496 BATTERY & EOL CALCULATIONS BATTERIES USED : (2) 12v-7AH