HomeMy WebLinkAboutBLD-2016-1517 - SOLAR PERMIT L C3' City of Anacortes Invoice/Permit#: BLD-2016-1517
904 6th Street
Applied date: 08/29/2016
Issue date: 09/27/2016
tP' try; Anacortes, WA 98221-0547
.- _: Expire date: 03/28/2018
' (360).293-1901
Job Address: 1200 0 AVE Permit Type: Commercial Alteration/Repair Permit
ANACORTES WA 98221 Project:
APN:
Remarks: New Flush mounted rack for roof mounted Solar Photovoltaic system.
Owner: CHANDLER'S SQUARE HOLDINGS, LLC Contractor: ECOTECH ENERGY SYSTEMS LLC
Address: 201 NE PARK PLAZA DR Address: 814 DUPONT ST
STE 105
VANCOUVER WA 98684-5874 BELLINGHAM WA 98225
Phone: Phone: (360) 318-7646
License#: ECOTEES951 RG
General Information: Fees:
Building Valuation 18924 Plan Review Deposit 99.86
Building Permit Fee 307.25
Plan Review Fee 99.85
State Building Code Fee 4.50
Total Calculated: 511.46
Deposits/Receipts: 0.00
Total Due: 511.46
ti -; mom- `,
:..� •i-
`7 'I -h I I 1i
7,1
11
�1 5 I AL.
•�▪ Q. 1 .-a 11
'•• A,, �.' I is Vl
)
.f , 1 . 1
✓ .I Ti E.
:t. i.
7l
'3
TI
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,;;OA I,FI
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMFNG, D;; ::I
HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROV IONS
OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR[NOT, THE
GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STAtE:OIfy
LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
SIGNATUROF OWNER OR AUTHORIZED AGENT ISSUED BY f ,aa ii
tlL i
!
CJR Engineering
Civil - Structural Engineering
Comprehensive Project Management
i
14602 15th PL W Phone: (425) 269-5204
Lynnwood, WA 98087-6043 Fax: (425) 671-0003
August 24, 2016
Cityof Anacortes ( 6.----,„
lBuildshg Dept. � � �::oy904 6 St. A _ ,
Anacortes WA 98221 (i T
.17
4*.liJitip__ libi
RE: Solar PV on 1200 & 1300 0 Ave 443,46'&•
Anacortes WA 9822140, '
tiff � G � � �.
,1'eap _ , 1
h �
Dear Sirs, Pi4t,, - �-
�
Echotech Solar is proposing installing solar systems at 1200 0 Ave and 1300 0 Ave in),' C)o, , '" ;
Anacortes, WA(formerly Anacortes Senior Housing, now Chandler's Square Retirement �'„ �`4.v 1'
Community). The solar panels have a distributed weight of 2.70 pounds per square foot '°{), --j
(psf). 45,i
I reviewed the original building structural drawings prepared by myself in 1996. The
2012 IEBC allows a 10% increase in lateral loads and a 5% increase in vertical loads
before the structural system has to be re-evaluated by an engineer. According to the
original drawings the roof design snow load is 30 psf; the design dead load is not listed
in the drawings. The current design snow load is 25 PSF. The increase in additional
dead load due to the proposed solar panels is less than the excess snow load that the
roof was originally designed for, so there is no need for additional engineering
calculations to re-evaluate the capacity.
If anything else is required regarding this matter, please call me at (425) 269-5204, or
email to cemens@cjreng.com .
Sincerely, OS J. Ros
0„IGITA[ WAS s
S�
CJR Engineering 4c G'may Gv�<Qo _ liN ,t<,
M \ /�� ,fin P/�..
suite *:'?; I� -�� - , , �1* .
■ . �2�1
Clemens J. Rossell, P.E. �°.,` s1Tv 9 4''
CJR Engineering Signed by: Clemens Rossell PE �s''ONAL �oti
Signature
Date: 2016.08.27 11:20:36 --7
. Tr. •-•,,.--..: t,•,,t':,17:- ... l'stro,'Itm, i'
•
; l' imk .
. . 4 . '1"" ... 1 0 '' 1111\47%.....,....
( ..: : /�. t • , is �.
t ! I e t t
7...n.'. .*"..."(/ __.,__.........1„..,...........
i
i I'Y p' _
f — -4
: i
•
it
• .(....1
— —11'
> ,
e,
1 .. k
___
„.,..„.
0
. II
, ___ __
;, , ,.
_1,_
L . _lb ii -
-
., ij4 T 1 MEI
p _
i' A ' j 4,2S,
i .
*I
k n T . � _
t
\iii-'"-"""'''
.41
y
T
/o•
/- 1\1\
f.
•
[ 11.,
`
40
L-
-:, i Y OF N ,( UR f E s -)r_HM•f ' E4,-s:-.
Ai-f‘,. ritzp T:77:-, 4'. .,i,A , ?''!-''''1-7. in'' '''-1)11 ir?.i cty ,`":41 g ---:
.:-..-RmiT NO. 8
_.
.. _ - _ _._ 6ir4
E..,UR F SS-
.H.. . .E - piiiiit 4;ti-g i
:� Y j� 4 #F La f I\d 0 t'^EC:WI {O (J V R f ; %. r *:1/ 1:5 yi r) a / 4 ,
rrAA
D 'i3 k I 'O)l !- !r "7R )'i F !S r �' I`�c'5 Q E``+"• "'_ p y
-. -
a - - E
4141
.ai �.. .,,,. p
.I.rr11l•'y illE
----1, ,
i 1
„i„„„
, ,
_ ........ 0,'
i r
, 1 lb I 1
,.......
{ may.--�-+
- IIP lIPP' i I______
i� t.+ o
10 Y I 11 b i 4$ - ..w�..++w!
I 1
r.i,.a.,.- 1 RRR 4l,
!_..1 , 1 r 1 , , , .011t f el"
. tali , , u...L4hihr Hi , Ahhiii _ ...N. ., _. 4.1
L ,11 _
am , ii , 1 . I 1 14""."'.."7/41 4.
Mil f
- M a
Si MI . • • ''''
/ .
! ,
Lowww
A
i, ............. ,. _
1 • 4
...., ,
,,,,.,,,,,,,,, ,
_ .
, _ • ,
.. , , .
iii, ., .
, 'i • , a 1 . - v I i f tili thifik.,_ flab I
1 'lif ' 41 . 4- 1 — ilk A„,„ , , e.,1 , „
' '' .
o i. ,r ... y. I
Y
a i
, , Alt ' , ir .
.,. ,, -r i— 0 t 4.- , 1_ I 1 II_ Mill l 4
l
. F
a A _
„ , -— il
•-- 66 ceiltd,;(4:::, . Mo. _. . ,._
; s. ... CI
O'
Jr
_ M
14 R
, ,yr:.: Nli.- ,
4
i
ill / ..*
a 4_. _..-..- --____�__.______
111111111111:t 1.
411011: -
� � R !• -
..ii
Ikir
AL
*it ii,44 IN
r •- 411. .i004104, IP ;
/ III ell
qa____IA /
•
i*4 *'
'ir+,-AI r d Illook
41.
0 Ss '/
t \ / ........ .
.O - 1
l i s A A A i 4a 444 4 i * +
• t
9• 1 I ' 4
_ gin.. I
1 I Ai, AL. .......
r d 11 T
t 1 1 .: 4 a
0 w * 0 -.),;.,-. oR•ii lirtss,-_ ,
. isli4„,. ,4
a i ti
k
Or 4
+ ll 41 ti •
4t4L it
'! - 1...-
CI
ill ,p, allibil .
tIMO 1
N •
. W.
r
- - -
. 1
144 aPtillit. ig
Go ogle r . l 3.d ca 1 ID Savo/ ' r c-R6 of Us* 1 Port a m error
1
Susie Deyo
From: Tim West <tim@ecotechenergy.com>
Sent: Monday, September 26, 2016 2:55 PM
To: Susie Deyo
Subject: Fwd: Chandler's Square Solar
Attachments: Chandler's Solar Site Map - Conduit Runs and Fire Access.jpg; Chandler's Solar
Explanation of Conformity to IFC Requirements.pdf
Forwarded message
From: "Dana Brandt" <dana@ecotechsolar.com>
Date: Sep 26, 2016 2:53 PM
Subject: Fwd: Chandler's Square Solar
To: "Tim West" <tim@ecotechsolar.com>
Cc:
Forwarded message
From: Dana Brandt <dana@ecotechsolar.com>
Date: Mon, Sep 26, 2016 at 2:26 PM
Subject: Chandler's Square Solar
To: Jack Kennedy <jackk@cityofanacortes.org>
Hi Jack,
Let's try this again...
Thanks a lot for your time on Friday - I really appreciate it. I've attached the updated site map for you with the following additions:
• The larger east-facing array is moved south away from the dormer to the north
• The DC conduit runs on the roof are marked in red
•The access points to the east and west roofs are called out.
•The location of the AC disconnects for the solar are marked on each building
I've also attached the statement you requested regarding the compliance of the electrical work with the IFC and NFPA 70.
Please let me know if you have any questions. Thanks again for working with me on this.
Best,
Dana
Dana Brandt
Ecotech Solar
www.ecotechsolar.com
dana@ecotechsolar.com
360.318.7646
seaP". " t-= 8l � PI
�Ls'wYR 3 Y � '� �rt
Explanation of Conformity to IFC Requirements
Solar Electric System
1200 & 1300 0 Ave, Anacortes
The solar electric systems installed at 1200 &1300 0 Ave will comply with all applicable
codes including IFC 605 and NFPA 70. All DC conduit runs will be labeled with the
following language: "WARNING: PHOTOVOLTAIC POWER SOURCE." AC disconnects,
inverters and points of interconnection will also be label according to the applicable
codes.
Ecotech Energy Systems, LLC DBA Ecotech Solar has obtained electrical permits
2703510E and 2703516E from Washington State Labor & Industries. The completed
installation will be inspected for NFPA 70, WAC and RCW compliance by Washington
State Labor & Industries.
Ecotech Solar • 814 Dupont Street Bellingham,WA 98225 • www.ecotechsolar.com
Dana Brandt,President • info@ecotechsolar.com • (360)318-7646
piiiii ,
Sunmodule/ SOLARWORI®
SW 340-350 XL MONO REALi/ALUE
AetntTUV Power controlled:
Lowest measuring tolerance in industry F---11_- --==-
CERTIFIED I.:.�
I I, pppoliq 0.
[13 Illf I
Every component is tested to meet 1500 V
3 times IEC requirements Y
RELIABLE O N O' %i
, I I NOW
, iiimiIL,"
AVAILABLE
To
Designed to withstand heavy
accumulations of snow and Ice 11111111 i1
011lloe4
MAX,LOAD i I
8500 P8/178 p,f O
Ii
I I
1000V Available with either 1000 V or 1500 V
1500V maximum voltage rating I
PER UL1703 O I
t
ZSR 25-year linear performance warranty l
WARRANTY 1111111111111/
and 10-year product warranty iiiiiin
i EI
O
I 1l
1 I
I, � I 1 j
111111 ,
I
Glass with anti-reflective coating j i ! 1 I i
---
Anti-Reflective6 --
Coating
I 1 1
World-class quality •Qualified,IEC 61215
•Sanely gtested,IEC 61730
V •Blowing sand resistance,IEC 60068-2-68
Fully-automated production lines and seamless monitoring of the process and Q E •Ammonia resistance,IEC 62716
1•� •Salt mis(corrosion,IEC 61701
material ensure the quality that the company sets as its benchmark for its sites •Perlodicinspection c US
worldwide. UL 1703
A. •Periodic inspection
luvFnhdY..e a Power controlled
SolarWorld Plus-Sorting ISO'900
Plus-Sortingguarantees highest system efficiency. SolarWorld onlydelivers modules LI ISO�aoa
g Y Y Eceltifi-d:
that have greater than or equal to the nameplate rated power. IC°"'°EEN CER`F°"
q f.BS CREEN CERIr FtEO-
C AIL
25-year linear performance guarantee and extension of product warranty to 10 years • IN.
SolarWorld guarantees a maximum performance digression of 0.7%p.a. in the course °d ,i7a V
of 25years,a significant added value compared to the two-phase warranties common
in the industry, along with our industry-first 10-year product warranty.*
'in accordance with the applicable SolarWorld Limited Warranty at purchase
www.solarworld.com/warranty
solarworld.com
, __ 7
111111/
Sunmodule/ SOLARW®RLD
SW 340-350 XL MONO REAL VALUE
PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)*
SW 340 SW 345 SW 350
Maximum power Pm„ 340 Wp 345 Wp 350 Wp
Open circuit voltage V°, 47.6 V 47.8 V 48 0 V
Maximum power point voltage V,,,pp 38.0 V 38.2 V 38.4 V
Short circuit current I. 9 69 A 9.75 A 9.82 A
Maximum power point current I,,,pp 9.01 A 910 A 9.17 A
Module efficiency r,,, 17.04% 17.29% 17.54%
'SIC:1000W/m2,25"C,AM 1.5
PERFORMANCE AT 800 W/M2,NOCT,AM 1.5
SW 340 SW 345 SW 350
Maximum power P,,,a% 259.3 Wp 263.8 Wp 267.2 Wp
Open circuit voltage Vo, . 41.5 V 41 8 V 42.0 V
Maximum power point voltage Vmpp 34.9 V 35.2 V 35.4 V
Short circuit current I,C 8.05A 8.10 A 816 A
Maximum power point current Impp 7.42 A 7.50 A 7.56 A
Minor reduction in efficiency under partial load conditions at 25'C:at 200 W/m',100%of the STC efficiency(1000 W/m')is achieved.
loon w/m2
I5c COMPONENT MATERIALS
Cellspermodule 72 Front Low-iron tempered glass
800 W/m2 with ARC(EN 12150)
a 600 w/m2 Cell type Monocrystalline Frame Clear an i ed.aiuminum
L Cell dimensions 6.17 in x 6.17 in Weight 47.6 Ibs(21. kg)
400 W/m2 (156.75 x 156.75 mm)
s
200 W/m2 _ THERMAL CHARACTERISTICS ADDITIONAL DATA
100 W/m2
- NOCT 46°C Power sorting -0 Wp/+5 Wp
V. TC1,. 0.042%/'C J-Box I P65
Module voltage(V]
-
TCV,, -0.304%/"C Connector PV wire per UL4703
37.8(961) with H4/UTX connectors
TCPmpp -0.43%/°C
4.20 T 1T T Module fire performance (UL 1703)Type 1
(106.65)- _L 4x J Operating temp -40 to+85°C
11.53 0 0.26(6.6)
(292 85)
° 00.35(9) ° PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION
u 63 Maximum system voltage NEC 1000 V or 1500 V-Specify when ordering
(397)
o Maximum system voltage SC 11 1000 V
0 0.39 x0.27 = 0 0, Maximum reverse current 25 A
(10 x 7)(4) N a
Number of bypass diodes 3
15.75
(400) Design loads* Two rail system 113 psf downward,64 psf upward
0 0 Design loads* Edge mounting 178 psf downward,23 psf upward
`Please refer to the Sunmodule installation instructions for the details associated with these load cases.
15.63
(397) o.as(n)
0 o I ,
= ° 0035(9) . Compatible with both"Top-Down"
0 0 0 0 -0 ' and"Bottom"mounting methods
1533
(399.50) 1.30(33) • J-Grounding Locations:
i . , - -4 locations along the length of the
F 39.4(1001) •It , .
module In the extended flange.
1.30(33)
114(29) -04
All units provided are imperial.SI units provided in parentheses.
SolarWorld AG reserves the right to make specification changes without notice. SW-01-7540US-I 1500V 160419
IRONRIDGE Engineering Design Guide
Roof •
Mount
System
2015 Edition v ./
A complete guide to engineering and designing with the IronRidge XR Rail based Roof Mount System.
IRON RI DGE Engineering Design Guide Table of Contents
This Engineering Design Guide was created to help our Engineering Data
engineering partners more easily design and specify PV 12 Code Compliance
roof mount applications using IronRidge components.
In addition to this document, IronRidge provides Thermal Expansion
a complete system of technical support including Engineering Assumptions
installation guides, pre-stamped certification letters 13 AWC Lag Pull-Out Chart
for most PV-friendly states, our online Design Assistant
software, and live, knowledgeable person-to-person Part Sizing & Part Numers
customer service.
14 Rails& Splices
Clamp Size Table
15 Clamps
Overview 16 Attachments
1 Introduction 17 Accessories
Technical Specifications Grounding
2 Assembled Views
3 Component View Support
4 Assembly CAD Details 18 System Support
Downloadable Support Documents
System Parts 3rd Party Partners
5 XR Rail Design Assistant
6 Internal Splice 19 Engineering Services
Customer Service
End Clamp
Mid Clamps
Warranty
7 Adjustable L-Foot
FlashFootTM 20 Warranty Information .
Under Clamp
8 Flush Mount Standoff
Fixed Tilt Length Leg
9 Adjustable Tilt Length Leg
Grounding Strap
Wire Clips
End Caps
10 Grounding
Design Assistant
11 Summary
support@ I ironridge.com I (800)227-9523 T.O.C. 2015 v1.73
IRON RI DGE Engineering Design Guide Overview
Introduction
IronRidge provides a comprehensive platform for designing a wide variety of photovoltaic systems for roof mounting applications.Due
to its modular architecture,it can handle nearly all commercially available PV modules and layout designs.The IronRidge Roof Mount
provides an all-in-one mounting solution,with the roof attachment FlashFoot,XR rails,and integrated grounding.IronRidge products
are engineered to last in the most extreme weather conditions and have been installed in every continent in the world.
Technical Specifications
Below is a brief summary of the technical specifications of the IronRidge Roof Mount platform. More detail will be provided in the
following pages. If there is additional information you require that is not listed in this Engineering Design Guide, please do not hesitate
to contact us at support@ironridge.com.
Allowable Roof Slope 0 to 45 Degrees Warranty 20 Year
Span Lengths Up to 12' Tilt Legs Yes (10"to 40")
Rail Lengths Standard &Custom Adjustable Tilt Legs Up to 45 Degrees
Rail Finish Clear, Black(Only XR10&XR100) Adjustable L Feet 1-1/8"vertical adjustability
Building Height Certified to 60' Splices Patent-pending internal
Max Wind Speed 170 Mph (for 7-10) Stand-offs Yes(4",7")
Module Orientation Landscape&Portrait Tilt Stand-offs Yes (3.75;6', 9")
Wind Exposure Category B,C&D Flashing FlashFoot(All-in-One Attachment)
Cantilever 40%of Maximum Span T-bolts Multiple Sizes
Max Ground Snow Load 90 psf Wire Clips Black Polycarbonate
Component Materials Aluminum and Stainless Steel End Caps Black Polycarbonate
Hardware Stainless Steel Fasteners Engineering Support Yes(P.E.Certified)
support@ I ironridge.com I (800)227-9523 Page 1 2015 v1.73
RON RIDGE Engineering Design Guide Overview
Assembled Views -
�� S _ `,
. ■ w
V • --'-- - ,t
•
• /
1.
J. .010 AA
• ♦ / • r ♦ • 1 + + .~.—.1 " i * .1.. l •, •+ ''R. \ •
i
r •` • 4. t r I t • 1 , . .; • 4 • •
f' ♦ l ♦ 4- , i •. j. • r R -i. { . -4. • ♦ • t ,+ '4 • L 4 ♦
+` • r • + 1 • • + r + t t If ♦ t. i 1 t 11` } ♦ i 4 } `•
♦�. - ♦ —• - _ I ♦ 1 t
�]J JrT 1 1
T •♦� ♦ t. •♦ / r t 1 t • y , r- -k� t • 1 —.i t. + t--- 4 ? , t--T
` 111
Flush Mounted
•
1 `1
ti r
S. .."'! 4411. 4. "
• _ • a ? - •
• '
• I I . -. , , .
Y t
Irf• • • • : . • -• t - r• •-
;
t • • • r ,. • t ♦ . • "• ,
♦ • • i i • • ,• 1 t . : 1 ♦ . t. t. 1 • • t y ♦
• + r • 4 • —• • • • 4 .t. — I 1j • ♦ • ♦ -. I t e 4 . 4 • y R • 4
♦ ♦ ♦ i ♦ + • • ♦ •- Tr t a 1 j 4 4 t • i 4 t 4 + R
.- - r r v
I I I 4 R
---4
t + r � ill I t i LL
' f I ' i
4 TTTTT
F r �. r i •- -t +- -,- i • �..j_ r-♦— + i s t +- 'i 1 + t • F - • • • • t
Tilt Mounted
For a complete 360 degree interactive roof mounting viewing environment,go to:ironridge.com/products/roofmounting/360view.
support@ I ironridge.com I (800)227-9523 Page 2 2015 v1.73
•
IRONRIDGE Engineering Design Guide Overview
XR Rails
XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q
JL
A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices
for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections.
• 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-tapping screws
• Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails
• Clear& black anod.finish • Clear& black anod.finish - Clear anodized finish • Grounding Straps offered
Attachments
FlashFoot Slotted L-Feet Standoffs Tilt Legs
--_ -____,......._ . _ - ..j.-._____ )16.Cik.-- —",... st- ,
Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired
with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees.
• Ships with all hardware • High-friction serrated face • Works with vent flashing • Attaches directly to rail
• IBC& IRC compliant • Heavy-duty profile shape • Ships pre-assembled • Ships with all hardware
• Certified with XR Rails • Clear& black anod.finish • 4"and 7" Lengths • Fixed and adjustable
Clamps &Grounding
End Clamps Mid Clamps Q Grounding Lugs Q Accessories
jili iiiii. ' 41 , .i _
. -
IMINIIP—/IMF L 1.0•MINP— - ..111L- -.11L-
Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and
modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails.
• Clear and black anod. • Parallel bonding T-bolt • No clips or washers • Snap-in Wire Clips
• Sizes from 1.22"to 2.3" • Reusable up to 10 times - Eliminates pre-drilling • Perfected End Caps
• Optional Under Clamps • Mill & black stainless • Easy top-slot mounting • UV-protected polymer
support@ I ironridge.com I (800)227-9523 Page 3 2015 v1.73
/lam IRON RI DGE Engineering Design Guide Overview
Assembly CAD Details Download AutoCAD File I Download PDF
VARIES - .
I I I I I I I I I I I I I I I 1
I I 1 I I I I I I I I I I I I
I I I I I I I I I I 1 1 1 1
Mid Clamp
I I I I I I I I I 1 1 1 1 1 1
1 I- 1 I I I I I I I I 1 I I I
I
1 1
I [ I I I
1 I I •-
o
),
1 1 I Ig 1 1 IaQ 1 1 I I I I I 1 C` A - __ I I I I_ Detail A-Mid Clamp to Rail-Plan
1 e I I 1I r SLOPE 3"=1'-0"
I I 1 1 1 1 1 I 1 1 1 11 1 I I I I
I.__ I111111 11111 111111111111111
Typical Flush Mount Array-Plan View
1/2"= 1'-0" End Clamp ,
4, "
,Numlmm,Standoff
...fr.,n.-4e>�._.cR i�3t'�.::�.4-.\.-\r..�'w�.+,.si:.�c��:Q.. y;,�..:t•..
-Magog Roof StNch,o `--Membmnwbn Madan
Section-Flush Mount-Flat Roof Detail B-End Clamp to Rail-Plan
3/4"= 1'-0" 3"=1'-0"
xR Rae tp
Rear TR Lop(Length Vali*
S.FrontTR Log —--
Steel Standoff
Aid Clamp \ — Solar Panel
cog.Roomy.). -Membandfnsdagan
AIllibL
Section-Tilt Mount-Flat Roof ,-- L-Foot
3/4"= 1'-0" _
6 �
aa_
Mid Clamp End Clamp— • � =
liaThi
XR Rail Flashing
Existing Roof Structure
Detail C-Typical Roof Connection
3"=1'-0"
w
Detail D-Mid Clamp to Rail-Elevation_ Detail E-End Clamp to Rail-Elev.
6"=1'-0" 6"=1'-0"
XR Roe VARIES
C j—D 1(E
u u u u u
Existing Roof Sbuoavo
I—VARIES—I
Editing Roof Structure
Section-Flush Mount-Sloped Roof
3/4"= 1'-0" Typical Flush Mount Array-Elevation
3/4"= 1'-0"
support@ I ironridge.com I (800)227-9523 Page 4 2015 v1.73
IRON RIDGE Engineering Design Guide System Parts
XR1000 Rail
XR1000 is a heavyweight among solar mounting rails, built to handle extreme climates and spans 12 feet or more for commercial applications.
Property Value
Material 6000 Series Aluminum
Finish Clear Anodized
Beam Height 3.00"
t
Weight/Linear Foot 0.945 Lbs
Total Cross-Sectional Area 0.807 In2
Section Modulus(X-axis) 0.530 In3
Moment of Inertia (X-axis) 0.843 In4
Moment of Inertia (Y-axis) 0.182 In4
Torsional Constant 0.436 In3
Polar Moment of Inertia 0.3299 In4
XR100 Rail
XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans.
Property Value
Material 6000 Series Aluminum
Finish Clear&Black Anodized
Beam Height 2.44"
Weight/Linear Foot 0.68 Lbs
Total Cross-Sectional Area 0.582 In2
Section Modulus(X-axis) 0.297 In3
Moment of Inertia (X-axis) 0.390 In4
Moment of Inertia(Y-axis) 0.085 In4
Torsional Constant 0.214 Ina
Polar Moment of Inertia 0.126 In4
XR10 Rail
XR10 is a low-profile mounting rail, perfectly matched to regions with light snow. It achieves 6 foot spans, while staying light and economical.
Property Value
Material 6000 Series Aluminum
Finish Clear&Black Anodized
- Beam Height 1.75"
Weight/Linear Foot 0.436 Lbs
Total Cross-Sectional Area 0.363 In2
--■ Section Modulus(X-axis) 0.136 In3
Moment of Inertia (X-axis) 0.124 In4
Moment of Inertia (Y-axis) 0.03211)4
Torsional Constant 0.076 Ina
Polar Moment of Inertia 0.033 In4
support@ I ironridge.com I (800)227-9523 Page 5 2015 v1.73
IRON RI DGE Engineering Design Guide System Parts
Internal Splice
IronRidge Rails are easy to extend with our patent-pending Internal Splices.
Property Value
• ' Material 6000 Series Aluminum
Finish Mill
----------"------._Ihll—
Length 12"
Hardware 2 SS Self-tapping Screws
End Clamp
IronRidge End Clamps secure PV modules to XR Rails using the top slot,independent upon the module's mounting holes.
Property Value
/
• Material 5000&6000 Series Aluminum
Finish Mill &Black
Height Varies depending on Module
I
, •�'�f Width 1.5"
Depth 1.5"
°i Weight 0.05 Lbs
Hardware '/a"-20 SS Nut and Bolt
Mid Clamp
IronRidge Mid Clamps secure PV modules to the rail when there are multiple modules in a row.
Property Value
Material 5000 Series Aluminum
,4111111nOtH ,
Ai % I Finish Mill&Black
Spacing between Modules 1/4"
Width 1"
a
410
Depth 1.5"
Weight 0.05 Lbs
Hardware Y4"-20 SS Nut and Bolt
Grounding Mid Clamp
Grounding Mid Clamps pierce through anodized coatings to ground array,being ETL listed to UL 2703.
'""' Property Value
ToMaterial 304 Stainless Steel
Finish Mill &Black
Spacing between Modules '/a"
Width 1"
Depth 1.2"
Weight 0.08 Lbs
Hardware '"-20 SS Nut and Bolt
support@ I ironridge.com I (800)227-9523 Page 6 2015 v1.73
IRONRIDG
E Engineering Design Guide System Parts
Slotted L-Foot
Our Slotted L-feet are engineered for most roof mounting applications.Vertical slots allow for easily dropping in rails with
attached hardware and provide adjustability to account for roof irregularities.
Property Value
Material 6000 Series Aluminum
Finish Mill & Black
Height 3"
Width 2"
Depth 2„
Length of Vertical Slot 1.125"
Weight 0.22 Lbs
Hardware 3/8"SS
FlashFootTM
IronRidge FlashFootTM is an all-in-one solar mounting product for composition shingle roofs that eliminates the need
for separate standoffs, flashings, and L-feet. FlashFoot incorporates a number of structural and waterproofing features
to securely attach IronRidge Rails to roof structures, while also protecting against water intrusion and weather damage.
Comes with flashing, lag bolt, and L-Foot.
i Property Value
Material Aluminum
Finish Mill & Black
Height 3.5"
Length 12"
Width 12"
Dual Mechanical Seal Yes
Open L-Foot Slot Yes
Weight 1.35 Lbs
Hardware 5/16"and 3/8"SS
Under Clamp
IronRidge Under Clamps secure PV modules to the XR1000 Rail using the mounting holes of the PV module and the side slot of the rail.
Property Value
Material 6000 Series Aluminum
Finish Mill
Spacing between Modules 1"
Width 1.6"
Depth 1.5"
Weight 0.05 Lbs
Hardware '"-20 SS Nut and Bolt
support@ I ironridge.corn I (800)227-9523 Page 7 2015 v1.73
,4,,/,,ik IRON RI DGE Engineering Design Guide System Parts
Flush Mount Standoff
Our Flush Mount Aluminum Standoffs are sized to integrate easily with Oatey Flashings. IronRidge Flush Mount Standoffs are available
in 4"and 7"lengths. Standoffs include L-Foot mounting hardware.Lag bolts not included.
r Property Value
Material (Post) 6000 Series Aluminum
Material (Base) 5000 Series Aluminum
Finish Mill
Heights 4,7"
Post Diameter 1.5"
Depth 4"
40410 Weight 0.84 Lbs
Hardware 5/16"
Fixed Tilt Length Leg
Our Fixed Tilt Legs attach directly to IronRidge XR Rails.This simple design provides adjustability in all 3 axes,and a variety of lengths
cover most angles. Each Tilt Leg Kit comes with the shorter front leg,the longer rear leg,mounting brackets and-VA. Property Value
IrlY Material (Legs) 6000 Series Aluminum
Material (Brackets) 5000 Series Aluminum
Finish Mill
Length (Short Leg) 6"
Length (Long Legs) 10'; 15,20"
Leg Diameter 1.5"Square Tube
Tube Weight/Linear Foot 0.80 Lbs
Height(Brackets) 2.6"
Width(Brackets) 1.85"
'41C., Depth (Brackets) 2"
Hardware 3/8"SS
support@ I ironridge.com I (800)227-9523 Page 8 2015 v1.73
•
IRON RIDGE Engineering Design Guide System Parts
Adjustable Tilt Length Leg
As with our Fixed Tilt Legs,the Adjustable Tilt Legs attach directly to IronRidge XR Rails. Each Tilt Leg Assembly kit comes with the
shorter fixed front leg,the longer adjustable rear leg,and all the necessary hardware.
Property Value
Material (Legs) 6000 Series Aluminum
Material (Brackets) 5000 Series Aluminum
Finish Mill
'Ilk ..
Length (Short Leg) 6"
)''- - 16"Range(Long Leg) 18"-22"
% 28"Range(Long Leg) 30"-46"
Outer Tube Diameter 1.8"Square Tube
l,'
Inner Tube Diameter 1.5"Square Tube
INio/ Upper Bracket 2.2"x4.25"x2"
Lower Bracket 2.6"x1.85"x2"
Hardware 3/8"SS
Bonding Strap
Bonding Straps are used to bond rail-to-rail connections.They are only required on the rail with the grounding lug. Bonding Strap
Expansion Joint also available.
,� .- 4- r' �. Property Value
Material Tin-plated Copper Flat Braid
Weight 0.054 Lbs
Wire Gauge 9 AWG
End Caps
End caps provide a finished look while protecting against the collection of water and debris inside the rail.
I_ 1_ I Property Value
Material Polycarbonate
Color Black
UV Protection Yes
Wire Clips
IronRidge Wire Clips snap into the top slot of XR Rails,and accommodate up to ten 5mm panel wires,or one MC4,one Enphase wire
and one dual Enphase wire. The Wire Clips are molded from black polycarbonate with UV protection.
lir Property Value
Material Polycarbonate
Color Black
UV Protection Yes .
Weight 0.01 Lbs
support@ I ironridge.com I (800)227-9523 Page 9 2015 v1.73
IRON RIDGE Engineering Design Guide System Parts
Microinverter Mounting Kit
Mount either one or two microinverters,depending on model.
.'4: . : Property Value
rill' ,, - ` ,,t Material Stainless Steel
Color Mill
Hardware 1/4 x 3/4"Hex orT-Bolts
Weight 0.06 Lbs
Grounding Lug
Manufactured from high strength copper alloy with stainless steel screw, UL listed and CSA certified. Hex bolt and grounding T bolt
versions available. Hex bolt version not compatible with XR10 or XR100 rails.
- .a Property Value
Material SS&Tin-plated Copper
'::--r.
Weight 0.154 Lbs
__ 0 Conductor Size 4-14 AWG
4, Listing UL 467 Compliant
-`I Hardware #10& 1/4"SS
Third-Party Grounding Components
Wiley grounding clips(WEEB DMC)are used in conjunction with the IronRidge Mid Clamps for grounding PV modules to rails.
Property Value
Material 304 Stainless Steel
..," 40, ETL Listed ANSI/UL 467 Compliant
7 Maximum Conductor Size 6 AWG(with two WEEBs
Vile •' contacting each module)
Hardware None
Wiley WEEB 6.7 grounding lugs are used in conjunction with copper wire to provide a continuous ground for every row of rails.
Property Value
WEEB Material 304 Stainless Steel
.
J ` Lug Material Tin-plated Copper
h.,
"J s ETL Listed ANSI/UL 467 Compliant
_y_ Ground Conductor One 14 AWG to 6 AWG or two
10 AWG,two 12 AWG
Hardware 1/4"-20&1/a"-28 SS
Wiley bonding jumpers are used to provide a continuous ground between spliced rail sections.Order one jumper for every splice.
.� . Property Value
'' WEEB Material 304 Stainless Steel
t i- 1,4 - - Braid Material Tin-plated Copper
_ rh ETL Listed ANSI/UL 467 Compliant
Hardware 1/4"-20 SS
support@ I ironridge.com I (800)227-9523 Page 10 2015 v1.73
IRON RIDGE Engineering Design Guide Design Assistant
Summary
With the IronRidge Design Assistant''our customers move from laboriously designing systems across the span of weeks,to intuitively
designing while pricing,a bill of materials and engineering calculations all updates in real-time.
If you choose to register for an online account,you will then be able to save your work and prevent losing your project's configuration
settings.
The application is so quick and easy to use,multiple what-if scenarios can be evaluated through immediate engineering and pricing
feedback. Engineered calculations comply with ASCE 7-10 building codes for expedited P.E.approval.
The IronRidge Design Assistant'"is provided free of charge to IronRidge customers.
Design, engineer and quote,
online, in just minutes.
ironridge.com/support/designassistant
.r•" .
el
Deign Asys1ant
414
f! '
i N11....•-a�11
1,3
Ii1.lA MAIN'
yexJ.0 11 I"
11.4-
support@ I ironridge.com I (800)227-9523 Page 11 2015 v1.73
IRON RI DGE Engineering Design Guide Engineering Data
Code Compliance
IronRidge Roof Mount components,when installed in accordance with the IronRidge Roof Mount Installation Manual,will be
structurally adequate and will meet the structural requirements of:
• ASCE/SEI 7-10 Min. Design Loads for Buildings&Other Structures
• California Building Code 2013 Edition
• AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, Effective November 1, 2012 (ICC-ES)
• Aluminum Design Manual, 2010 Edition
• Florida Building Code 2010 Edition
• Florida Residential Building Code 2010 Edition
• International Building Code 2012 Edition
• International Residential Building Code 2012 Edition
IronRidge Rails with Integrated Grounding conforms to:
• UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat-Plate Photovoltaic
Modules and Panels
• ETL Listed requirements and certification
Thermal Expansion (Expansion Joints)
For rows exceeding 100 feet of rail,a Grounding Strap Expansion Joint is required for thermal expansion.Insert Internal Splice into first
rail and secure with screw.Assemble and secure Expansion Joint an inch from rail end.Slide second rail over Internal Splice,attach
other end of Expansion Joint with hardware,and secure with screw.Torque screws and nuts to 84 in-lbs.
support@ I ironridge.com I (800)227-9523 Page 12 2015 v1.73
IRON RI DGE Engineering Design Guide Engineering Data
AWC Lag Pull-out Chart
Lag pull-out(withdrawal)capacities(Ibs) in typical roof lumber(ASD)
Material Specific Gravity Lag Screw Specifications*
Douglas Fir, Larch 0.50 266
Douglas Fir,South 0.46 235
Engelmann Spruce, Lodgepole Pine 0.46 235
(MSR 1650 f&higher)
Hem, Fir, Redwood (close grain) 0.43 212
Hem, Fir(North) 0.46 235
Southern Pine 0.55 307
Spruce,Pine,Fir 0.42 205
Spruce Pine Fir 0.50 266
(E of 2 million psi and higher grades of MSR and MEL)
Sources:American Wood Council,NDS 2005, Table 11.2A, 11.3.2A.
Notes:(1)Thread must be embedded in the side grain of a rafter or other structural member integral with the building structure.
(2)Lag bolts must be located in the middle third of the structural member.
4.
(3)These values are not valid for wet services. •
(4)This table does not include shear capacities.If necessary,contact a local engineer to specify lag bolt size with regard to
shear forces.
(5) Install lag bolts with head and washer flush to surface(no gap).Do not over-torque.
(6) Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary.
See Table 70.3.1 in the American Wood Council NDS for Wood Construction.
Thread
depth
*5/16"shaft,per inch thread depth(Use flat washers with lag screws).
support@ I ironridge.com I (800)227-9523 Page 13 2015 v1.73
IRON RIDGE Engineering Design Guide Part Sizing &Part#s
Rails & Splices When top mounting panels,the lengths of XR Rails required for each row may be determined by
multiplying the quantity of modules in a row by the modules width.Add to this 1/4 inch space between
each module and 1.5 inches to each end for the total length of rail required for that row.
XR Rails
Part Number Description Weight Packaging
XR-1000-132A XR1000,Rail 132"(11 Feet),Clear 11.24 Lbs Sub-bundles of 4;Bundles of 80
XR-1000-168A XR1000,Rail 168"(14 Feet),Clear 14.30 Lbs Sub-bundles of 4;Bundles of 80
XR-1000-204A XR1000,Rail 204"(17 Feet),Clear 17.36 Lbs Sub-bundles of 4;Bundles of 80
XR-100-132A XR100,Rail 132"(11 Feet),Clear 7.69 Lbs Sub-bundles of4;Bundles of 80
XR-100-1328 XR100,Rail 132"(11 Feet),Black 7.69 Lbs Sub-bundles of 4;Bundles of 80
XR-100-168A XR100,Rail 168"(14 Feet),Clear 9.76 Lbs Sub-bundles of 4;Bundles of 80
XR-100-168B XR100,Rail 168"(14 Feet),Black 9.76 Lbs Sub-bundles of 4;Bundles of 80
XR-100-204A XR100,Rail 204"(17 Feet),Clear 11.88 Lbs Sub-bundles of 4;Bundles of 80
XR-100-2048 XR100,Rail 204"(17 Feet),Black 11.88 Lbs Sub-bundles of 4;Bundles of 80
XR-10-132A XR10,Rail 132"(11 Feet),Clear 4.80 Lbs Sub-bundles of 4;Bundles of 160
XR-10-132B XR10,Rail 132"(11 Feet),Black 4.80 Lbs Sub-bundles of 4;Bundles of 160
XR-10-168A XR10,Rail 168"(14 Feet),Clear 6.11 Lbs Sub-bundles of 4;Bundles of 160
XR-10-168B XR10,Rail 168"(14 Feet),Black 6.11 Lbs Sub-bundles of4;Bundles of 160
XR-10-204A XR10,Rail 204"(17 Feet),Clear 7.41 Lbs Sub-bundles of 4;Bundles of 160
XR-10-204B XR10,Rail 204"(17 Feet),Black 7.41 Lbs Sub-bundles of 4;Bundles of 160
Internal Splices
Part Numer Description Weight Packaging
XR-1000-SPLC XR1000 Splice 0.55 Lbs 1 Splice/Kit;20 Splices/Box
XR-100-SPLC XR100 Splice 0.54 Lbs 1 Splice/Kit;20 Splices/Box
XR-10-SPLC XR10 Splice 0.53 Lbs 1 Splice/Kit;20 Splices/Box
Clamps Module Clamp size depends on the module thickness.Use the table below to determine which Module Clamp will fit
your projects module thickness.
ModuleThickness Clamp Info Part Numbers
Mm Inches Type End Clamp Hex Mid Clamp T-bolt Mid Clamp Grounding Mid Clamp
31.0-32.5 1.22-1.28 I 29-7000-125 29-7000-105 29-70TB-105 RS-GD-MCL-200
32.5-33.5 1.28-1.32 L 29-7000-130 29-7000-105 29-7018-105 RS-GD-MCL-200
33.3-34.8 1.31-1.37 A 29-7000-134 29-7000-105 29-70TB-105 RS-GD-MCL-200
34.8-36.8 1.37-1.45 B 29-7000-224 29-7000-105 29-70TB-105 RS-GD-MCL-225
37.6-38.6 1.48-1.52 M 29-7000-150 29-7000-101 29-70TB-101 RS-GD-MCL-225
39.0-41.0 1.53-1.61 C 29-7000-157 29-7000-101 29-70TB-101 RS-GD-MCL-225
41.1 -42.7 1.62-1.68 J 29-7000-165 29-7000-101 29-70TB-101 RS-GD-MCL-250
42.7-44.2 1.68-1.74 E 29-7000-171 29-7000-101 29-70TB-101 RS-GD-MCL-250
45.0-47.0 1.77-1.85 F 29-7000-214 29-7000-108 29-70TB-108 RS-GD-MCL-250
46.7-48.3 1.84-1.90 K 29-7000-187 29-7000-108 29-70TB-108 RS-GD-MCL-275
49.0-51.1 1.93-2.01 G 29-7000-204 29-7000-108 29-70TB-108 RS-GD-MCL-275
57.4-58.9 2.26-2.32 H 29-7000-230 29-7000-104 29-70TB-104 Unsupported
support@ I ironridge.com I (800)227-9523 Page 14 2015 v1.73
IRON RI DGE Engineering Design Guide Part Sizing& Part #s
End Clamps
Part Number Description Weight Packaging
29-7000-125 Kit,4pcs,End Clamp I,1.25';Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-130 Kit,4pcs,End Clamp L,1.30';Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-134 Kit,4pcs,End Clamp A,1,34;Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-224 Kit,4pcs,End Clamp B,1.41,Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-150 Kit,4pcs,End Clamp M,1.50',Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-157 Kit,4pcs,End Clamp C,1.57';Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-165 Kit,4pcs,End Clamp J,1.65';Mill 0,3 Lbs Kits of 4;Boxes of 25
29-7000-171 Kit,4pcs,End Clamp E,1.71';Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-214 Kit,4pcs,End Clamp F,1.81',Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-187 Kit,4pcs,End Clamp K,1.87;Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-204 Kit,4pcs,End Clamp G,1.97';Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-230 Kit,4pcs,End Clamp H,2.30",Mill 0.3 Lbs Kits of 4;Boxes of 25
29-7000-125B Kit,4pcs,End Clamp I,1.25"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-130B Kit,4pcs,End Clamp L,1.30';Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-134B Kit,4pcs,End Clamp A,1.34"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-224B Kit,4pcs,End Clamp B,1.41"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-1 SOB Kit,4pcs,End Clamp M,1.50';Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-157B Kit,4pcs,End Clamp C,1.57"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-165B Kit,4pcs,End Clamp J,1.65"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-171B Kit,4pcs,End Clamp E,1.71"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-214B Kit,4pcs,End Clamp F,1.81"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-187B Kit,4pcs,End Clamp K,1.87"Black 0.3 Lbs Kits of 4;Boxes of 25
29-7000-204B Kit,4pcs,End Clamp G,1.97"Black 0.3 Lbs Kits of 4;Boxes of 25
Mid Clamps
Part Number Description Weight Packaging
29-7000-105 Kit,4pcs,Mid Clamp A/B/I/L,2.00",Mill(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-101 Kit,4pcs,Mid Clamp C/D/J/E/M,2.25',Mill(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-108 Kit,4pcs,Mid Clamp F/K/G,2.50';Mill(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-104 Kit,4pcs,Mid Clamp H 2.75",Mill(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-105 Kit,4pcs,Mid Clamp A/B/I/L,2.00';Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-101 Kit,4pcs,Mid Clamp C/D/J/E/M,2.25',Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-108 Kit,4pcs,Mid Clamp F/K/G,2.50';Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-104 Kit,4pcs,Mid Clamp H,2.75';Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-105B Kit,4pcs,Mid Clamp A/B/I/L,2.0';Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-101 B Kit,4pcs,Mid Clamp C/D/J/E/M,2.25';Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-108B Kit,4pcs,Mid Clamp F/K/G,2.5',Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-7000-104B Kit,4pcs,Mid Clamp H,2.75';Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-105B Kit,4pcs,Mid Clamp A/B/I/L,2.0O'lack(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-101 B Kit,4pcs,Mid Clamp C/D/J/E/M,2.25",Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-108B Kit,4pcs,Mid Clamp F/K/G,2.50 Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
29-70TB-104B Kit,4pcs,Mid Clamp H,2.75,Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
support@ I ironridge.com I (800)227-9523 Page 15 2015 v1.73
IRON RIDGE Engineering Design Guide Part Sizing & Part #s
Grounding Mid Clamps
Part Number Description Weight Packaging
RS-GD-MCL-200 Kit,4pcs,Mid Clamp A/B/I/L,2.00",Mill (T bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-225 Kit,4pcs,Mid Clamp C/D/J/EM,2.25", Mill (T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-250 Kit,4pcs, Mid Clamp F/K/G,2.50'; Mill (T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-275 Kit,4pcs, Mid Clamp H 2.75';Mill (T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-200B Kit,4pcs,Mid Clamp A/B/1/L,2.00', Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-225B Kit,4pcs,Mid Clamp C/D/J/E/M,2.25'; Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-250B Kit,4pcs, Mid Clamp F/K/G,2.50'; Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50
RS-GD-MCL-275B Kit,4pcs, Mid Clamp H, 2.75', Black(T bolt) 0.3 Lbs Kits of 4;Boxes of 50
Under Clamps
Part Number Description Weight Packaging
29-7000-117 Kit,4pcs, Under Clamp 0.4 Lbs Kits of 4;Boxes of 25
Attachments
Slotted L-Feet
Part Number Description Weight Packaging
RS-LFT-001 4-pack,Slotted L-Foot,Mill 1.14 Lbs 4 L-feet/Pack;25 Kits/Box
RS-LFT 001 B 4-pack,Slotted L-Foot,Black 1.14 Lbs 4 L-feet/Pack;25 Kits/Box
FlashFootTM
Part Number Description Weight Packaging
RF-FLSH-001 Kit,6-pack, IronRidge FlashFoot(Mill) (L-foot Included) 8.1 Lbs 6 Flashings/Box
RF-FLSH-001 B Kit,6-pack, IronRidge FlashFoot(Black) (L-foot Included) 8.1 Lbs 6 Flashings/Box
Flush Mount Standoffs
Part Number Description Weight Packaging
51-6004-500L Kit,4"Standoff, Flush Mount,Mill 0.56 Lbs 20 Standoffs/Box
51-6007-500L Kit,7"Standoff, Flush Mount,Mill 0.84 Lbs 20 Standoffs/Box
support@ I ironridge.com I (800)227-9523 Page 16 2015 v1.73
I
,1
I
RONRIDGE Engineering Design Guide Part Sizing & Part #s
Adjustable Tilt Legs
Part Number Description Weight Packaging
51-7516-016H Adjustable Tilt Leg, 16 inches(18-22") 4.29 Lbs 12 Adjustable Tilt Legs/Box
51-7528-028H Adjustable Tilt Leg,28 inches (30-46") 6.34 Lbs 12 Adjustable Tilt Legs/Box
Fixed Tilt Legs
Part Number Description Weight Packaging
51-7210-010 Tilt Leg Kit, 10';Mill 1.87 Lbs 20 Fixed Tilt Legs/Box 1
51-7215-015 Tilt Leg Kit, 15': Mill 2.20 Lbs 20 Fixed Tilt Legs/Box
51-7220-020 Tilt Leg Kit,20'; Mill 2.56 Lbs 20 Fixed Tilt Legs/Box
Accessories
Part Number Description Weight Packaging I1
XR-1000-CAP XR1000 End Cap (Polybag, 20) 7 Lbs/Box 20 End Caps/Bag;500 Caps/Box
XR-100-CAP XR100 End Cap(Polybag,20) 5 Lbs/Box 20 End Caps/Bag;500 Caps/Box
XR-10-CAP XR10 End Cap(Polybag,20) 4 Lbs/Box 20 End Caps/Bag;500 Caps/Box
29-4000-077 Wire Clip (Polybag,20) 6.70 Lbs/Box 20 Clips/Bag;500 Clips/Box
29-5003-005 Kit,'/a x 3/4 Microinverter Mounting 10.30 Lbs/Box 150 Kits/Box
29-50TB-005 Kit,1/4 x 3/4 Microinverter Mounting,T Bolt 10.30 Lbs/Box 150 Kits/Box
Grounding
Part Number Description Weight Packaging
RS-GDST-001 Bonding Strap 2.7 Lbs/Box 50 Kits/Box
RS-GDXP-001 Bonding Strap Expansion Joint 2.0 Lbs/Box 25 Kits/Box
RS-GDLG-001 Grounding Lug (XR1000 Compatible Only) 7.7 Lbs/Box 50 Kits/Box
RS-GDLG-002 Grounding Lug CT-Bolt) 7.9 Lbs/Box 50 Kits/Box
29-4000-001 WEEB DMC Compression Clip .50 Lbs/Box 100 Clips/Box
29-4000-002 WEEB Grounding Lug 6.7 12.45 Lbs/Box 100 Lugs /Box
29-4000-003 WEEB Bonding Jumper 17.55 Lbs/Box 100 Jumpers/Box
support@ I ironridge.com I (800)227-9523 Page 17 2015 v1.73
IRON RIDGE Engineering Design Guide Support
System Support
IronRidge provides a complete system of technical support including installation guides, pre-stamped certification letters for most
PV-friendly states, our online Design Assistant software, and live, knowledgeable person-to-person customer service.
Downloadable Support Documents
Our website at www.ironridge.com/products/roofmounting/systemsupport contains all of the technical support information necessary
to design,quote, certify,and install an IronRidge Roof Mount system.The specific documents that can be found here include:
• CAD files (AutoCAD format)
• Engineering Design Guide
• Pre-stamped Certification Letters
• Installation Guides
• Parts Catalog
3rd Party Partners
•
We've engineered best-of-class 3rd party solutions with our Roof Mount platform to further improve the quality we offer customers.
Where appropriate, pre-stamped certification letters are included to simplify and expedite the design,quoting,and permitting
processes.At this time,we work with roofing products from the following companies:
• Ecofasten
• Enphase
• Quick Mount PV
• S5!
• Wiley
Design Assistant
The IronRidge Design Assistant automates much of the Design and Engineering phases of a project.Easily accessible from our website,
the Design Assistant provides a highly intuitive layout interface,automatically calculates critical engineering information based on
your project's specific load conditions,provides the ability to add optional components and 3rd party products,and determines an
accurate bill of materials and quotations.
The Roof Mount Design Assistant can be accessed at:www.ironridge.com/rm
support@ I ironridge.com I (800)227-9523 Page 18 2015 v1.73
IRONRIDGE Engineering Design Guide Support
Engineering Services
IronRidge provides expedited site specific certification letters for many standard load conditions.These letters are available in most
PV-friendly states, including:
Arizona North Carolina
California New Hampshire
Colorado New Jersey
Connecticut New Mexico
D.C. Nevada
Delaware New York
Florida Ohio
Georgia Oklahoma
Hawaii Oregon
Iowa Pennsylvania
Illinois Rhode Island
Indiana South Carolina
Louisiana Tennessee
Massachusetts Texas
Maryland Utah
Michigan Virginia
Maine Vermont
Minnesota Washington
Missouri
In addition,we provide pre-stamped certification letters for:
Ontario
New Zealand
Puerto Rico
For non-standard certifications,wet-stamped letters,or specialized engineering requests, please contact support@ironridge.com.
Customer Service
The IronRidge support staff is knowledgeable,experienced,friendly,and responsive.We would be happy to provide assistance on any
questions you may have. Please feel free to contact us through your preferred method at:
Email:supportPironridge.com
Phone:800-227-9523
•
support@ I ironridge.com I (800)227-9523 Page 19 2015 v1.73
IRON RIDGE Engineering Design Guide Warranty
Warranty Information
Effective for IronRidge, Inc. ("IronRidge") mounting structure components("Products") manufactured after April 1st, 2012, IronRidge
provides the following warranties,for Products installed properly and used for the purpose for which the Products are designed:
• finishes shall be free of visible defects,peeling,or cracking, under normal atmospheric conditions,for a period of
three (3)years from the earlier of(i)the date of complete installation of the Product or(ii)thirty days after the
original purchaser's date of purchase of the Product("Finish Warranty");
• components shall be free of structurally-related defects in materials fora period of ten (10)years from the earlier of(i)
the date of complete installation of the Product or(ii)thirty days after the original purchaser's date of purchase of the
Product;
• components shall be free of functionally-related manufacturing defects for a period of twenty(20)years from date of
manufacture.
The Finish Warranty does not apply to:(a)surface oxidation of the galvanized steel components or any foreign residue deposited on
Product finish;and (b) Products installed in corrosive atmospheric conditions,as defined solely by IronRidge;corrosive atmospheric
conditions include, but are not limited to,conditions where Product is exposed to corrosive chemicals,fumes,cement dust,salt water
marine environments or to continual spraying of either salt or fresh water.The Finish Warranty is VOID if(c)the practices specified by
AAMA 609&610-02—"Cleaning and Maintenance for Architecturally Finished Aluminum"(www.aamanet.org)are not followed by Pur-
chaser for IronRidge's aluminum based components;and (d)if the practices specified by ASTM A780/A780M-09"Standard Practice
for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings"are not followed by Purchaser for IronRidge's galvanized
steel-based components.
The warranties above do not cover any parts or materials not manufactured by IronRidge,and exclude non-functionally-related de-
fects,as defined solely by IronRidge. The warranties do not cover any defect that has not been reported to IronRidge in writing within
twenty(20)days after discovery of such defect.
In the event of breach of or non-compliance with the warranties set forth above, IronRidge's sole obligation and liability,and the sole
and exclusive remedy for such breach or non-compliance,shall be correction of defects by repair,replacement,or credit,at IronRidge's
sole discretion. Such repair, replacement or credit shall completely satisfy and discharge all of IronRidge's liability with respect to these
warranties.
Refurbished Product may be used to repair or replace the defective components.Transportation,installation,labor,or any other costs
associated with Product replacement are not covered by these warranties and are not reimbursable.These warranties additionally do
not cover(a) normal wear,or damage resulting from misuse,overloading,abuse, improper installation (including failure to follow pro-
fessional instruction and certification),negligence,or accident,or from force majeure acts including any natural disasters,war or crimi-
nal acts;and (b) Products that have been altered, modified or repaired without written authorization from IronRidge or its authorized
representative;and (c) Products used in a manner or for a purpose other than that specified by IronRidge.A formal document proving
the purchase and the purchase date of the Product is required with any warranty claim.
Except as set forth above,IronRidge sells the Products on an"AS IS"basis,which may not be free of errors or defects,and ALL EXPRESS
OR IMPLIED REPRESENTATIONS AND WARRANTIES, INCLUDING ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE,QUALITY,WORKMANLIKE EFFORT,CORRESPONDENCE TO DESCRIPTION, DESIGN,TITLE OR NON-INFRINGEMENT,OR ARISING
FROM COURSE OF DEALING,COURSE OF PERFORMANCE OR TRADE PRACTICE,ARE HEREBY DISCLAIMED.
support@ I ironridge.com I (800)227-9523 Page 20 2015 v1.73
•
r
1,
S
I
t 9
.
40,
S - -
bi ..
e .-. .= _
it
111 15 01
iv ► ' 4.7
sr if i 4
sib..
•
RR
io
NI . . ' ,
,•
. 4It v. rir
a !
ter ►
r
. . aii,li
11/
•
r . ;I . . , ,
_ _
, .,
. . .. . . , _ , :v.. . a, .-- 21, .A I.
) r
•
11.
L. _ . _ i
..
Ili . t lie
r _
ri-
Ilk I ,
' . .4
4, (h. r . ,., , yAI
'IL
�M/ ��
i et: • ' . 1* 0
I k A la ' . t ,4 0
tt
ilk • v ... ._. ..
4 NOMMIIIIII: 7 t
ir
^ram
• .ra 4 ,! ii
•
k
_
..
, ..
, .
I to
4,1114411)
' ..... •
r.
� *r s � a .*� .r `S
+ t
•
Alt I
vr
Ar
0
W .
•
0
is
Ai
d
1
•
f
i
1