Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-2024-0654 - FIRE ALARM
For inspections, please call (360) 293-1901 PARCEL: P19989 LEGAL DESCRIPTION: APPLICANT: Odushkin, Charity 1501 Kentucky Street Bellingham, WA 98226 4252002724 OWNER: ANACORTES HOSPITALITY INC UNKNOWN ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 7000.00 $7,000.00 $7,000.00Total: FEES:Paid Due Plan Review Fee $90.51 $0.00 Building Permit Fee $139.25 $0.00 State Building Code Council fee $25.00 $0.00 $0.00Totals : REQUIRED INSPECTIONS Fire Alarm ELECTRICAL CONTRACTOR:GUARDIAN SECURITY SYSTEMS INC 1743 1ST AVE S SEATTLE, WA 98134 2066226545 License: GUARDSS233K5 Expires: 09/30/2026 $254.76 BLD-2024-0654 FIRE ALARM ISSUED: EXPIRES: 10/15/2024 04/15/2026 PROJECT NAME: COUNTRY CORNER SITE ADDRESS: 7601 STATE ROUTE 20 ANACORTES Page 1 of 1Printed by : Cheri Gleichmann on: 12/24/2024 12:49 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ Seattle - Tacoma - Yakima -Bellingham 1501 Kentucky St. Bellingham WA 98229 Tel: 360-647-0110 GUARDIAN SECURITY Skagit County Attn: Planning and Development Re: Country Corner 7601 State Route 20 Anacortes, WA 98221 Scope of Work: I am requesting a fire permit to replace the existing fire system with a AFC-100 potter fire panel and an AES radio, along with notification and initiating devices. For fire monitoring. I have included all the required information. Please let me know if you need anything further. Thank you, V{tÜ|àç bwâá{~|Ç Fire Division Project Manager O: 360-647-0110 Ext. 324 Cell: 425-200-2724 E: W: www.guardiansecurity.com SY S T E M I N F O R M A T I O N FA-01 COUNTRY CORNER 7601 STATE ROUTE 20, ANACORTES, WA 98221 FIRE ALARM SYSTEM PANEL REPLACEMENT SHEET INDEX SEQUENCE OF OPERATIONS MATRIXWIRE DESIGNATION GENERAL NOTES SCOPE OF WORK MONITORING COMPANY TAHARKA MUHAMMAD NICET LEVEL IV CERT. 138245 EXP. 01/07/2026 SYMBOLS LEGEND H FOR POTTER SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. CODE ANALYSIS INFORMATION NVICINITY MAP SCALE: NTS SITE LOCATION DA T E NO RE L E A S E / R E V I S I O N S DE S C R I P T I O N RE V . B Y : GU A R D I A N S E C U R I T Y 17 4 3 1 S T A V E . S O . , S E A T T L E , W A S H I N G T O N 9 8 1 3 4 TE L . ( 2 0 6 ) 6 2 2 - 6 5 4 5 FA X ( 2 0 6 ) 6 2 8 - 4 9 9 0 C O U N T R Y C O R N E R FI R E A L A R M P A N E L R E P L A C E M E N T 76 0 1 S T A T E R O U T E 2 0 AN A C O R T E S , W A S H I N G T O N 9 8 2 2 1 1 1 CITY OF ANACORTES FIRE DEPARTMENT APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT#:________________________ ADDRESS:_______________________ APPROVED BY:___________________ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. BLD-2024-0654 7601 State Route 20 FA C P D E T A I L , C A L C S , D E V I C E D E T A I L S & M O U N T I N G H E I G H T S TAHARKA MUHAMMAD NICET LEVEL IV CERT. 138245 EXP. 01/07/2026 SYSTEM CALCULATIONS FA-02 TYPICAL WIRING AND MOUNTING DETAILS TO SLC DEVICES (SPARE NOTIFICATION CIRCUIT) POTTER AFC-100 CONTROL PANEL END-OF-LINE RESISTOR 5.1K OHM Part #3005013 12 W END-OF-LINE RESISTOR 5.1K OHM Part #3005013 12 W AUXILIARY 24 VOLT POWER FROM FACP +++ --- +++ --- MOVE THE “CL-A” DIP SWITCH TO “DOWN” POSITION FOR CLASS B WIRING TO 5623 HEAT DETEXTOR PAD100-SIM FROM FACP TO NEXT DEVICE PAD100-ZM DA T E NO RE L E A S E / R E V I S I O N S DE S C R I P T I O N RE V . B Y : GU A R D I A N S E C U R I T Y 17 4 3 1 S T A V E . S O . , S E A T T L E , W A S H I N G T O N 9 8 1 3 4 TE L . ( 2 0 6 ) 6 2 2 - 6 5 4 5 FA X ( 2 0 6 ) 6 2 8 - 4 9 9 0 C O U N T R Y C O R N E R FI R E A L A R M P A N E L R E P L A C E M E N T 76 0 1 S T A T E R O U T E 2 0 AN A C O R T E S , W A S H I N G T O N 9 8 2 2 1 TYPICAL DEVICE MOUNTING HEIGHTS STORAGE ROOM LOWER LEVEL 12V 18AH BATTERIES PROVIDED FIELD VERIFY (SPARE NOTIFICATION CIRCUIT) FIELD VERIFY NOTES: CEILING HEIGHT = 10' OR LESS, UNLESS OTHERWISE NOTED. CEILING TYPE = MIX BUILDING MONITORING IS EXISTING PHONE LINE. 1. 2. 3. STORAGE ROOM LOWER LEVEL 1D 120 VAC, DEDICATED ( BY OTHERS ) 1 MAIN UPPER LEVEL H HHH 1 H EXISTING CONVENTIONAL ZONE CIRCUIT 1 T.B.D T.B.D H H OFFICE RECEPTIONSTORAGE CORRIDOR CORRIDOR RESTROOM MECHANICAL CRAWL SPACE CLO. STAIR UP CRAWL SPACE CONCRETE SLAB CONCRETE SLAB STORAGE 1 1 T.B.D T.B.D NOT IN SCOPE OF WORK H H H H STORAGE WOMEN'S RR MEN'S RR FREEZER COOLER KITCHEN RESTAURANT STORAGE GROCERY MEN'S RR STAIRDN LOADING DOCK STORAGE WOMEN'S RR BAR COOLER MEN'S RR COFFEE BAR PASS THRU WITH HEAT LAMPS WOMEN'S RR WALK-IN COOLER HALL H 1 NOT IN SCOPE OF WORK FLAGNOTE: REPLACE/SWAP OUT EXISTING FACP PANEL.1 RI S E R D I A G R A M , L O W E R & M A I N L E V E L F I R E A L A R M L A Y O U T RISER DIAGRAM SCALE: NTS FA-03 TAHARKA MUHAMMAD NICET LEVEL IV CERT. 138245 EXP. 01/07/2026 DA T E NO RE L E A S E / R E V I S I O N S DE S C R I P T I O N RE V . B Y : GU A R D I A N S E C U R I T Y 17 4 3 1 S T A V E . S O . , S E A T T L E , W A S H I N G T O N 9 8 1 3 4 TE L . ( 2 0 6 ) 6 2 2 - 6 5 4 5 FA X ( 2 0 6 ) 6 2 8 - 4 9 9 0 C O U N T R Y C O R N E R FI R E A L A R M P A N E L R E P L A C E M E N T 76 0 1 S T A T E R O U T E 2 0 AN A C O R T E S , W A S H I N G T O N 9 8 2 2 1 LOWER LEVEL FIRE ALARM LAYOUT SCALE: 1/8" = 1'-0" N MAIN UPPER LEVEL FIRE ALARM LAYOUT SCALE: 1/8" = 1'-0" N Fire Alarm System Submittal Project # 76331-1 COUNTRY CORNER 7601 STATE ROUTE 20, ANACORTES, WASHINGTON 98221 MFG. MODEL# DESCRIPTION [CONTROL] POTTER AFC-100 FIRE ALARM CONTROL PANEL ANALOG/ADRESSABLE POTTER UD2000 DACT DIGITAL ALARM COMMUNICATOR TRANSMITTER [MODULES] POTTER PAD100-SIM SINGLE INPUT MONITOR MODULE POTTER PAD100-ZM ZONE MODULE [BATTERIES] PACIFIC POWER SLA-12180NB 12V 18 AH BATTERIES MATERIALS LIST AFC-100 Fire Alarm Control Panel 8830134 - REV G • 5/23 PAGE 1 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description The AFC-100 is an analog/addressable fire alarm system with a total system capacity of 100 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The AFC-100 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN-1000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Technical Specifications Features • 100 addresses available on this analog addressable system • Additional system capacity achieved via multi-point SLC modules • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built-In • System Operates as Class A or Class B for SLC, P-Link and NACs • 5 Amp Power Supply, Expandable to 310 amps • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP Communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information • Product includes 5 year warranty Dimensions 16”W x 17”H x 3 7/8”D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Battery Standby Current-130 mA Alarm Current-200 mA• 5 Amps power for NACs, I/O, and P-Link• 3 Amps per NAC, regulated• 1 Amp per I/O circuit, regulated• Battery Charger range 8-55 Ah• Battery Charger voltage 27.3 VDC• P-Link maximum current of 1 Amp Temperature and Humidity Range 32° to 120° (0°C to 49°C) with a maximum humidity of 93% non-condensing. Standards • NFPA, 13, 15, 16, 17, 17A, 70, 72, and 750 • ANSI/UL 864 - Local (L), Remote Station (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX). Type of Service: Automatic (A), Manual (M),Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT) • IBC (International Building Code) S7357165-0328:0509 NYC Fire Dept. Certificate of Approval6256 8830134 - REV G • 5/23 PAGE 2 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com AFC-100 Fire Alarm Control Panel SLC Loop Accessories SLC Loop Devices The control panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. Device Description PAD Series-PD Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.1 to 3.5%/foot. UL 268 7th Edition. PAD Series-PHD Combination Analog Photoelectric Smoke/Heat Detector – a smoke detector with a listed obscuration of 1.1 to 3.5 %/foot obscuration and a fixed temperature range of 135° to 185° F heat detector. Smoke detection compliant with UL 268 7th Edition. PAD Series-PCD Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon Monoxide detection compliant with UL 2075. PAD200-PCHD Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat detection with a fixed temperature range of 135° to 185° F and UL 521 7th Edition compliant. Carbon Monoxide detection compliant with UL 2075. PAD Series-HD Analog Fixed Temperature (135° - 185°F) or Rate-of-Rise Heat Detector (software selectable). PAD Series-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at 10Amps @ 250/120VAC or 8 Amps at 30VDC. PAD Series-DUCT Addressable Duct Smoke Detector. PAD100-6DB 6” round base that is mountable to an electrical box and wired for connection to the PAD100/200 devices. PAD100-4DB 4” round base that may be mounted to an electrical box and wired for connection to the PAD100/200 devices. PAD100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop and used for connection to the PAD100/200 devices. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay at rated at 2 amps at 30 VDC or 0.5A at 125VAC. For PAD100/200 devices only. PAD100-SB Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local, group, and/or all call. For PAD100/200 devices only. PAD Series-CD Addressable CO gas detector. PAD200-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. PAD300-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure or pendant mount applications. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration of local, group, and/or all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) and used for connection to the PAD100/200 devices. PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W and used for connection with the PAD100/200 devices. PAD300-6DB 6” round base which is mountable to an electrical box and wired for connection to the PAD300 devices. PAD300-4DB 4” round base which is mountable to an electrical box and wired for connection to the to the PAD300 devices. PAD300-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. Used for connection to the PAD300 devices. PAD300-RB Addressable Relay Base that contains one relay controlled by the SLC. The Relay is rated 2 amps at 30 VDC or 0.5A at 125VAC and used for connection to the PAD300 devices PAD300-SB Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local, group, and/or all call; and used for connection to the PAD300 devices. PAD300-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration of local, group, and/or all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) and used for a connection to the PAD300 devices. 8830134 - REV G • 5/23 PAGE 3 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com AFC-100 Fire Alarm Control Panel Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4” square electrical box. PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD100-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PAD100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. For use with the PAD100-DUCTR only. PAD100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. 8830134 - REV G • 5/23 PAGE 4 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com AFC-100 Fire Alarm Control Panel SLC Features Sensor Features User Interface Ethernet/I.P. Connection P-Link The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as “T-Taps”, with a max wiring distance of 10,000 Ft. The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. The AFC-100 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. The AFC-100 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 32 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: SLCE-127 -Nohmi addressable loop expansion module for retrofit applications. The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre-Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. RA-6500R(F) – 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) – 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) – 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the AFC-100 as releasing circuits. CA-6075 – Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 – UL listed, Dual line telephone alarm communicator DRV-50 – LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 – Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 – Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 – Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 – Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three AFC series panels to share a single reporting technology. IDC-6 – Initiating device circuit provides 6 programmable inputs AE-2 – Two card expansion cabinet AE-8 – Eight card expansion cabinet AE-14 – Fourteen card expansion cabinet 8830134 - REV G • 5/23 PAGE 5 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com AFC-100 Fire Alarm Control Panel Dimensions Model Description Stock No. AFC-100 Fire Alarm Control Panel 3992753 Replacement Board AFC-100 3992757 Ordering Information DO O R = 16 . 7 8 " BA C K B O X = 1 6 . 5 6 " DOOR = 16.07"BACKBOX = 15.77" 3.75 "DEPTH = DEPTH = 3.84" TOP LEFT SIDE RIGHT SIDE BOTTOM DWG #593-1 8830146 - REV B • 6/19 page 1 OF 3 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com UD-2000 Digital Alarm Communicator Description The UD-2000 Digital alarm Communicator Transmitter (DaCT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-2000 communicates using the SIa- DCS or ademco Contact ID protocols. When enabled, the DaCT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DaCT will hang up. The DaCT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DaCT to work properly, it must be installed on a plain old telephone service (pOTS) line or equivalent deemed by the authority having jurisdiction. The DaCT must be installed before any other equipment to ensure it can seize the phone line. phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DaCT to the phone system should be 26 aWg or larger. Technical Specifications Operating Voltage 22.0-24.0V Standby Current 16ma alarm Current 23ma Max UD-2000s per panel 1 Dimensions 4”W * 6”H * 1-5/8”D Operating Tempuratures 0°C - 49°C (32°F- 120°F) Operating Humidity Range 10% - 93% @ 30°C (86°F) (non-condensing) Mounting Options In FaCp Behind keypad Shipping Weight 0.47 lbs Features • allows for communication to Monitoring Station • Communicates using SIa-DCS or ademco Contact ID protocols • For use with Ipa, aFC, and aRC series addressable panels and pFC-4064 Conventional panel • Status LeDs indicate operation of DaCT card • Installs with ease behind main panel LCD display via User Interface bracket • Device address is set internally to address 1 • Includes two (2) RJ45 phone cords 8830146 - REV B • 6/19 page 2 OF 3 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com UD-2000 Digital Alarm Communicator Installation Install in accordance with compatible fire alarm control panel installation manual The UD-2000 DaCT is connected to the control panel using the provided four-wire cable connection (p/N 5210514) between p4 and UD-2000 p1. The connection is power limited and supervised. 1. power system down. 2. Slide the UD-2000 into the card guides located under the User Interface bracket. 3. Secure the UD-2000 to the User Interface bracket using the provided #6-32x3/8” screw 4. Install the provided four-wire conductor jumper between UD-2000 p1 and p4. 1 2 3 4 5 6 7 8 1 - Grey2 - Tan3 - Black4 - Red5 - Green6 - Yellow7 - Blue8 - Brown 1 2 3 4 5 6 7 8 Plain Old Telephone (POTS) lines RJ31X Phone Jack to UD-2000 Ring (Grey) Line In From Telco UD-2000 Communicator Tip (Brown)Out to Premises Phones Ring (Red) Tip (Green) Ring (Grey) Tip (Brown)Out to Premises Phones Ring (Red) Tip (Green) Line In From Telco Telco 2TipRingTip Ring TipRingTip RingPhone 2Telco 1 Phone 1 Telco Tip = RedTelco Ring = GreenPhone Tip = BrownPhone Ring = Grey 8830146 - REV B • 6/19 page 3 OF 3 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com UD-2000 Digital Alarm Communicator UD-2000 DACT Installation on Small Platform Panel UD-2000 DACT Installation on Large Platform Panel Slides in guides under main board. Screw DWG #593-32A Slides in guides under main board. Screw DWG #593-32A DETAIL E SCALE 1 : 1 DETAIL D SCALE 1 : 1 p Connector on small platform control panel p Connector on main board DETAIL B SCALE 1 : 1 Fig 1 Fig 2 Ordering Information Model Description Stock No. UD-2000 Digital Alarm Communicator 3992769 PAD100-ZM Conventional Zone Module 8830085 - REV D • 12/18 page 1 OF 4 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description The paD100-ZM module uses one (1) address on an SLC Loop when monitoring two (2) Class B or one (1) Class a circuit. The module requires and supervises a 24VDC auxiliary power connection. The 24VDC power source must be either a potter Ipa series addressable panel, or a potter pSN series power supply. The IDC may be wired Class B or Class a which is selectable by an on board DIp switch. The paD100-ZM employs one red LeD to indicate the module’s status. In normal condition, the LED flashes when the device is being polled by the control panel. When a device is activated, the LED will flash at a fast rate. Application The paD100-ZM is compatible with potter’s Ipa and aFC/aRC series addressable fire alarm control panels. The PAD100-ZM is used to supervise a zone of conventional 2-wire smoke detectors on an Initiating Device Circuit (IDC). The paD100-ZM is capable of monitoring two (2) separate Class B or one (1) Class a circuits. Setting the Address each addressable SLC device must be assigned an address. The address is set using the DIp switch located on the paD100-ZM. When the paD100-ZM is used to monitor two individual Class B circuits a single device address is assigned, each input is then identified as a sub-point of the module address. For example, if the address number is assigned as “8”, the B1 input will be “8.1” and the B2 input will be “8.2”. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24.0V Max SLC Standby Current 240μA Max SLC alarm Current 240μA aux power Required 19 - 28V Max Detector Standby Current of IDC at 24 VDC 1ma Max Module alarm Current of IDC at 24 VDC 50ma Max Wiring Resistance of IDC 100Ω Max Wiring Capacitance of IDC 1μF eOL Resistor 5.1K Ω Operating Temperature Range 32 to 120ºF (0 to 49ºC) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module per Loop 127 units Dimensions 4.17” (106mm)L × 4.17”(106mm)W × 1.14” (29mm)D Mounting Options Standard 4” Square or Double gang Box Shipping Weight 0.6 lbs Features • Compatible with conventional 2-wire smoke detectors • IDC can be wired One (1) Class a or Two (2) Class B • Monitors presence of 24VDC aux power • SLC Class a, Class X & Class B • Mounts in a standard 4” or double gang box • Wiring terminals accessible when mounted in box • all wiring terminals accept 22 to 12aWg • product includes a 5 year warranty • UUKL Listed for Smoke Control PAD100-SIM Single Input Module 8830083 - REV D • 12/18 page 1 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description The paD100-SIM uses one (1) SLC loop addresses when monitoring one (1) Class B circuit. The module mounts on either a 4” square or double gang box. The module is capable of monitoring one (1) Class B circuit. The paD100-SIM includes one red LeD to indicate the module’s status. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The paD100-SIM is compatible with potter’s Ipa and aFC/aRC series addressable fire alarm control panels. The PAD100-SIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIp switch located on the paD100-SIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24.0V Max SLC Standby Current 240μA Max SLC alarm Current 240μA Max Wiring Resistance of IDC 100 Ω Max Wiring Capacitance of IDC 1μF eOL Resistor 5.1K Ω Operating Temperature Range 32 to 120ºF (0 to 49ºC) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module per Loop 127 units Dimensions 4.17” (106mm)L × 4.17” (106mm)W × 1.14” (29mm)D Mounting Options Standard 4” Square or Double gang Box Shipping Weight 0.6 lbs Features • One (1) Class B monitoring input • SLC Class a, Class X & Class B • Mounts in a standard 4” or double gang box • Wiring terminals accessible when mounted in box • all wiring terminals accept 22 to 12 aWg • product includes a 5 year warranty • UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. 8830083 - REV D • 12/18 page 2 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PAD100-SIM Single Input Module Installation Using Compatible Electrical Box Wiring Diagram PAD100-SIM With Class B Circuit Fig 1 Model Description Stock No. paD100-SIM Single Input Module 3992704 Ordering Information Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END-OF-LINE RESISTOR 5.1K OHM Part #3005013 12 W 8830085 - REV D • 12/18 page 2 OF 4 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PAD100-ZM Conventional Zone Module Installation Using Compatible Electrical Box Wiring Diagrams Typical Class B Wiring Diagram Typical Class A Wiring Diagram Fig 1 Model Description Stock No. paD100-ZM Conventional Zone Module 3992706 Ordering Information Fig 2 Fig 3 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END-OF-LINE RESISTOR 5.1K OHM Part #3005013 12 W END-OF-LINE RESISTOR5.1K OHM Part #3005013 12 W AUXILIARY 24 VOLT POWER FROM FACP +++ --- +++ --- MOVE THE “CL-A” DIP SWITCHTO “DOWN” POSITIONFOR CLASS B WIRING FROM FACP OR PREVIOUS MODULE TO NEXT MODULE 24 VOLT POWER TO FACPOR NEXT MODULE 24 VOLT POWER FROM FACPOR PREVIOUS MODULE NOTE: END-OF-LINE RESISTORIS NOT REQUIRED+++ --- MOVE THE “CL-A” DIP SWITCH TO “UP” POSITION FOR CLASS A WIRING 8830085 - REV D • 12/18 page 3 OF 4 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PAD100-ZM Conventional Zone Module Compatible 2-Wire Smoke Detectors & Bases Detector Model Identifier Base Model Identifier SYSTEM SENSOR (Brk) (Max. No. Of Detectors Per Zone is 10) 1400 a N/a N/a 2400 a N/a N/a 2400TH a N/a N/a 2W-B a N/a N/a 2WT-B a N/a N/a DETECTION SYSTEM (Max. No. Of Detectors Per Zone is 11) DS250 a MB2W/MB2WL a DS250TH a MB2W/MB2WL a ESL (Max. No. Of Detectors Per Zone is 20) 611U S10 601U S00 611UD S10 601U S00 611UT S10 601U S00 612U S10 601U S00 612UD S10 601U S00 613U5 S10 601U S00 611UD S10 609U10 S00 612UD S10 609U10 S00 425C S10 N/a N/a 425CT S10 N/a N/a HOCHIKI (Max. No. Of Detectors Per Zone is 20) SLR-24 HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 NS6-220 HB-3 SLR-24H HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 SIJ-24 HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 8830085 - REV D • 12/18 page 4 OF 4 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PAD100-ZM Conventional Zone Module Detector Model Identifier Base Model Identifier FENWAL (Max. No. Of Detectors Per Zone is 14) CpD-7051 I51Fe1 2-WIRe Fe51a pSD-7155 p55Fe1 2WRLT Fe52a pSD-7156 p56Fe1 2WRB Fe55a all of the above Fenwal detectors and bases can be used in any combination. Retrofit Base Adaptor 70-501000-003, Identifier MAFE1 (for series 70-201000 Bases, Models -001, -002, -003, and -005). Duct Housing with Detector Base DH-51, Identifier DH22FE5 (for CPD-7051 and PSD-7155 detectors only). POTTER (Max. No. Of Detectors Per Zone is 25) pS-24 HD-3 (HOCHIKI)SB-46 HB-71(HOCHIKI) HB-54 (HOCHIKI) SB-93 HB-3 (HOCHIKI) pS-24H HD-3 (HOCHIKI)SB-46 HB-71 (HOCHIKI) HB-54 (HOCHIKI) IS-24 HD-3 (HOCHIKI)SB-46 HB-71 (HOCHIKI) HB-54 (HOCHIKI) NOTE: If using a mix of System Sensor and other smoke detectors, a maximum of 20 detectors shall be permitted. PS S E R I E S TERMINALS: (mm) DIMENSIONS: inch (mm)PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (900mA to 10.50 volts) 10-hr. (1.70A to 10.50 volts) 5-hr. (3.20A to 10.20 volts) 1-hr. (11.1A to 9.00 volts) 18.00 AH17.00 AH 16.00 AH 11.1 AH Approximate Weight 12.60 lbs. (5.72 kg) Internal Resistance (approx.) 14.0 milliohms Max Short-Duration Discharge Current (10 Sec.)180.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)1 Month 3 Month 6 Month 97% 91% 83% Operating Temperature Range ChargeDischarge 5°F (-15°C) to 122°F (50°C) -4°F (-20°C) to 140°F (60°C) Case ABS Plastic Power Sonic Chargers PSC-122000A-C PSC-122000-PCPSC-124000-PC PSC-124000A-C www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com General Purpose Fire & SecurityEmergency Lighting Warning: Risk of fire, explosion, or burns.Do not disassemble,heat above 60 C, or incinerate. Rechargeable Sealed Lead-Acid BatteryDC power, constant voltage chargeCycle use: 14.4 - 15.0V(20 C)Standby use: 13.5 - 13.8V(20 C)Initial current: 5.4A MAX 8 3 1334001054 MODEL PS-12180 NB 12 Volt 18.0 Amp. Hr. Sealed RechargeableBattery 120180400208 L HT H W Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. L: 7.13 (181) W: 3.00 (76) H: 6.59 (167) HT: 6.59 (167) L: 7.13 (181) W: 3.00 (76) H: 6.59 (167) HT: 6.59 (167) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. FEATURES •10 – 12 year design life •Absorbent Glass Mat (AGM) technology for superior performance •Valve regulated, maintenance free spill proof construction •Power/volume ratio yielding excellent energy density •Rugged vibration and impact resistant ABS case and cover •Gas recombination technology APPROVALS •Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed •U.L. recognized •ISO9001:2015 – Quality management systems Medical Re v 1 : 1 1 / 1 8 PS-12180S 12V 18.0 AH @ 20-hr.12V 17.0 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Torque – Not Applicable 6. 3 5 1. 5 7.95 3.4 2.5 0. 8 F2: Quick disconnect tabs, 0.250" x 0.032" – Mate with AMP. INC FASTON “250” series NB2: Tin plated brass post with ‘Nut & Bolt’ fasteners Torque: 3.9~5.4 Nxm T12: Threaded insert with 5mm stud fastener Torque: 2.0~3.0 Nxm 14mm 4.5 m m 6m m 12 m m 2mm 12mm M5 6mm PS S E R I E S www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Cap a c i t y R e t e n t i o n R a t i o ( % ) Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC(104oF) 30oC(86oF)20oC(68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage2.25 - 2.30 V/Cell Ret e n t i o n C a p a c i t y ( % ) Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Cap a c i t y R e t e n t i o n R a t i o ( % ) Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC(104oF) 30oC (86oF)20oC (68oF) 5oC(41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Ret e n t i o n C a p a c i t y ( % ) Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to fl oat charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifi cations. CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have diffi culty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certifi cation, etc. APPLICATIONS •General purpose •Emergency lighting •Medical •Fire and security PS-12180S 12V 18.0 AH @ 20-hr.12V 17.0 AH @ 10-hr. Rechargeable Sealed Lead Acid BatteryPS – General Purpose Series Re v 1 : 1 1 / 1 8