HomeMy WebLinkAboutBLD-2024-0322 - WINDOWS/DOORS/SIDING NEW OR REPLACEDFor inspections, please call (360) 293-1901 PARCEL: P56826 LEGAL DESCRIPTION: APPLICANT: Newhard, Zachary 209 Prospect St #1 Bellingham, WA 98225 360.390.5847 OWNER: HOUSING AUTHORITY OF ANACORTES UNKNOWN ANACORTES, WA 98221 VALUATIONS: SIDING SQUARE FOOTAGE NEW OR REPLACED 9440.00 $84,960.00 $84,960.00Total: FEES:Paid Due BUILDING PERMIT FEE WINDOWS/DOORS/SIDING $888.75 $0.00 PLAN REVIEW FEE WINDOWS DOORS SIDING $577.69 $0.00 State Building Code Council fee $25.00 $0.00 $0.00Totals : REQUIRED INSPECTIONS Fenestration U-Factors HOUSEWRAP/FLASHING Windows/Siding/Doors Final $1,491.44 BLD-2024-0322 WINDOWS/DOORS/SIDING NEW OR REPLACED ISSUED: EXPIRES: 10/24/2024 10/24/2026 PROJECT NAME: AHA SITE 1 RECLADDING SITE ADDRESS: 508-511 6TH & T AV ANACORTES Page 1 of 1Printed by : Cheri Gleichmann on: 11/13/2024 01:34 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ SITE ONE RE-CLADDING 511 AVENUE, ANACORTES 98221 PERMIT SET SITE CITY OF ANACORTES PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT #:______________________________ ADDRESS:____ _______________ APPROVED BY: ______________ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. BLD-2024-0322 508-511 T Avenue Approved 04/30/2024 INDEX / PROJECT INFORMATION G0.01 ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ARROW CENTERLINE PLAN NORTH TRUE NORTH NORTH ARROWS GRID HEAD WALL TAG FLOOR TAG ROOF TAG CEILING TAG INTERIOR WALL TAG A.H.U. ALT. A.V. BLDG. DIA. D.S. (E) EF EH 0 WL-X FL-X RF-X CL-X 1' - 0" A.F.F. X DOOR # WL-X FL-X RF-X ELECT. ELEV. EQ CL-X 1' - 0" A.F.F. EXIST. EXT. F.E. F.E.C F.F FIN. G.A. G.L.B. G.W.B. HR. INSUL. INT. DOOR TAG WINDOW TAG ROOM TAGS 101 00 HARDWARE GROUP X Room name 101 Room name 101 INTERIOR PLANSW S EXTERIOR CLADDING TAG EXTERIOR ELEVATION TAG 1 TYPE X Ref A101 1 1 Ref REVISION TAG 1 MECH. MIN. MISC. MTL. (N) O.C. O.D. O.F.C.C. O.F.C.I. P.L. P.T. REF. REQ'D RM. RWL. SCHED. SHT. SIM. S.S. ST. STL. 1 SPOT ELEVATION (USED WHEREVER THERE IS NO REVISION CLOUD) STRUCT. T.O. T.O.B. T.O.S. T.S. TYP. U.N.O. V V.I.F. W/ W/O @ & AIR HANDLING UNIT ALTERNATE AUDIO / VISUAL BUILDING DIAMETER DOWNSPOUT EXISTING EXHAUST FAN EXHAUST HOOD ELECTRICAL ELEVATION EQUAL EXISTING EXTERIOR FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FINISH GAUGE GLUE LAMINATED BEAM GYPSUM WALLBOARD HOUR INSULATION INTERIOR MECHANICAL MINIMUM MISCELLANEOUS METAL NEW ON CENTER OVERFLOW DRAIN OWNER FURNISHED CONTRACTOR COORDINDATED OWNER FURNISHED CONTRACTOR INSTALLED PROPERTY LINE PRESSURE TREATED REFERENCE REQUIRED ROOM RAINWATER LEADER SCHEDULE SHEET SIMILAR STAINLESS STEEL STREET STEEL STRUCTURAL TOP OF TOP OF BEAM TOP OF SLAB TUBE STEEL TYPICAL UNLESS NOTED OTHERWISE VENT PIPE VERIFY IN FIELD WITH WITHOUT AT AND Re f Re f ARCHITECTURAL ABBREVIATIONSARCHITECTURAL SYMBOLS ARCHITECTS ZERVAS 209 PROSPECT STREET BELLINGHAM, WA 98225 PH: (360) 734-4744 CONTACT: ZACH NEWHARD ZACH@ZERVASGROUP.COM ANACORTES HOUSING AUTHORITY 719 Q AVE ANACORTES, WA 98221 PH: (360) 293-7831 CONTACT: SNADY COX DESIGN TEAM OWNER SITE ADDRESS : 511 T AVENUE, Anacortes 98221 PARCEL #: P56826 SITE INFORMATION SITE ADDRESS: PROJECT SITE 4th St 2021 IEBC ANALYSIS THE FOLLOWING IS A PARTIAL LISTING OF REQUIREMENTS, ALL APPLICABLE CODES TO APPLY PROJECT SHALL COMPLY WITH 2021 IEBC, STATE AND LOCAL CODES. ROOF FIRE CLASSIFICATION: CLASS C PER TABLE 1505.1 UL CLASS A IEBC - CHAPTER 7 ALTERATIONS - LEVEL 1 VICINITY MAP PROJECT DESCRIPTION / NARRATIVE SITE ONE RECLADDING IS APPROXIMATELY 9,440 SQUARE FEET OF SIDING ON TWO ADJACENT SEPARATE BUILDING ON THE SAME SITE. WORK WILL INCLUDE COMPLETE TEAR OFF TO EXPLOSE WALL SHEATHING. INSTALLATION OF NEW UNDERLAYMENT, SIDING, AND ASSOCIATED FLASHINGS. NOT TO SCALE NORTH PARCEL # LEGAL DESCRIPTION: 511 T AVENUE, Anacortes 98221 P56826 (0.6900 ac) LOTS 11 THROUGH 20, BLOCK 12, BOWMAN'S CENTRAL SHIP HARBOR WATERFRONT PLAT OF ANACORTES, AS PER PLAT RECORDED IN VOLUME 2 OF PLATS, PAGE 33, RECORDS OF SKAGIT COUNTY, WASHINGTON. SURVEY AF# 201004210001 GENERAL NOTES: 1. PRIOR TO COMMENCEMENT OF WORK COORDINATE WITH OWNER CONSTRUCTION STAGING, ACCESS, AND MAJOR DELIVERIES. 2. PROTECT LANDSCAPING, LAWN AREAS AND PAVERS. LAY DOWN TRIM BOARDS OVER LAWN AND PAVER AREAS PRIOR TO TRAVERSING OR PARKING MAN/MATERIAL LIFTS. RESTORE LANDSCAPING, CLEAN TRACK/TIRE MARKS FROM SIDEWALKS. 3. PROVIDE TEMPORARY FENCE ENCLOSURES AND SAFETY BARRIERS FOR: A. MATERIAL STAGING AREAS B. AREAS THAT MATERIAL/MAN LIFTS ARE CONTINUOUSLY OPERATING IN. C. PEDESTRIAN WALKWAYS THAT ARE WITHIN 10' OF ROOF EDGE (WHEN WORK IS BEING PERFORMED). STAGING AREA AND PARKING TO BE COORDINATED WITH THE ANACORTES HOUSING AUTHORITY OWNER AND RESIDENT ACCESS TO THIS ENTRY/EXIT MUST BE MAINTAINED THROUGH DURATION OF CONSTRUCTION OWNER AND RESIDENT ACCESS TO THIS ENTRY/EXIT MUST BE MAINTAINED THROUGH DURATION OF CONSTRUCTION STAGING AREA AND PARKING TO BE COORDINATED WITH THE ANACORTES HOUSING AUTHORITY PLAYGROUND CONTRACT LIMITS AND STAGING CO M M E R C I A L S t AD-2.01 ARCHITECTURE BUILDING 1 EXISTING EXTERIOR ELEVATIONS DRAWING INDEX GENERAL G0.00 G0.01 COVER INDEX / PROJECT INFORMATION AD-2.02 BUILDING 1 EXISTING EXTERIOR ELEVATIONS AD-2.03 BUILDING 2 EXISTING EXTERIOR ELEVATIONS AD-2.04 BUILDING 2 EXISTING EXTERIOR ELEVATIONS A-2.01 BUILDING 1 EXTERIOR ELEVATIONS A-2.02 BUILDING 1 EXTERIOR ELEVATIONS A-2.03 BUILDING 2 EXTERIOR ELEVATIONS A-1.01 SITE PLAN A-2.04 BUILDING 2 EXTERIOR ELEVATIONS A-7.01 EXTERIOR DETAILS A-7.02 EXTERIOR DETAILS A-3.01 RE-CLADDING DETAILS / EXISTING PHOTOS A-8.01 PAINT SCHEME PERSPECTIVES Approved 04/30/2024 SITE PLAN A1.01 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING SITE PLAN 3/32" = 1'-0"1 17 ' - 6 " 28 ' - 4 " 13 ' - 0 " 36 ' - 0 " 17 ' - 6 " 9' - 6 " 53'-0" 9'- 0 " 7' - 0 " 78'-8"28'-4" 67 ' - 4 " 37'-4" 1 ST FL. ELEV. = 100.0' 4'-0" BUILDING #1 1 ST FL. ELEV. = 113.0' BUILDING #2 1 ST FL. ELEV. = 118.0' 99 ' - 1 0 " 8' - 0 " 4'- 0 " 8' - 0 " 12 ' - 0 " 13 ' - 0 " 14'-0"24'-0"6'-0"78'-8"7'-0"28'-4"20'-0" 90° 12'-0"18'-0"56'-0" 12'-0"27'-0"62'-4"45'-0"28'-0"28'-4"7'-0" 28 ' - 4 " 8'- 0 " 24 ' - 0 " 12 ' - 6 " 6' - 0 " 8'- 0 " 4'-0" 3'- 6 " 12 ' - 6 " 4' - 0 " 9' - 0 " 12 ' - 0 " 4'-0"8'-0" 4' - 0 " 4' - 0 " 4' - 0 " 9'-0" 4'-0" 6'-0" 4'-0" 9'-0" PARKING AREA ASPHALT PLAY AREA ASPHALT DRYING MAINT. SCREEN FENCING 4'-0" 12'-0"13'-8"32'-0"10'-4" PARKING AREA ASPHALT DR Y I N G GA R B . GA R B . 36'-0" Approved 04/30/2024 BUILDING 1 EXISTING EXTERIOR ELEVATIONS AD2.01 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING EAST ELEVATION BUILDING - 1 1/4" = 1'-0"1 NORTH ELEVATION BUILDING - 1 1/4" = 1'-0"2 TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" 16' 11-3/4" 8' 11-1/4" 0' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR EXISTING, ROUGH-SAWN 5/8" CEDAR TEXTURED FACE T-111 PLYWOOD EXISTING 2" Ø G. I. DOWNSPOUTS (TYPICAL) EXISTING, ROUGH-SAWN 5/8" CEDAR TEXTURED FACE T-111 PLYWOOD 12" 4-1/2" Approved 04/30/2024 EXISTING 2" Ø G. I. DS (TYP.) EXISTING 2 SQ. FT. MINIMUM SCREENED LOUVER (TYPICAL) EXISTING 1 X 12 FASCIA BOARD 12" 4-1/2" EXISTING, ROUGH-SAWN 5/8" CEDAR TEXTURED FACE T-111 PLYWOOD BUILDING 1 EXISTING EXTERIOR ELEVATIONS AD2.02 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING WEST ELEVATION BUILDING - 1 1/4" = 1'-0"1 SOUTH ELEVATION BUILDING - 1 1/4" = 1'-0"2 TOP OF PLATE 2 ND FLOOR 1 ST FLOOR TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" 16' 11-3/4" 8' 11-1/4" 0' 0" Approved 04/30/2024 BUILDING 2 EXISTING EXTERIOR ELEVATIONS AD2.03 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING EAST ELEVATION BUILDING - 2 1/4" = 1'-0"1 NORTH ELEVATION BUILDING - 2 1/4" = 1'-0"2 TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 20' 11-3/4" 12' 11-1/4" 4' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 20' 11-3/4" 12' 11-1/4" 4' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" 4 EXISTING, ROUGH-SAWN 5/8" CEDAR TEXTURED FACE T-111 PLYWOOD EXISTING 2" Ø G. I. DOWNSPOUTS (TYPICAL) EXISTING 2 SQ. FT. MINIMUM SCREENED LOUVER (TYPICAL) EXISTING FLASH UP 4" BEHIND SIDING TYPICAL AT JUNCTION OF SIDING AND ROOFING EXISTING 5/8" CEDAR SAW TEXTURED FACE T-111 PLYWOOD EXISTING 2" Ø G. I. DOWNSPOUTS (TYPICAL) 12" 4-1/2" Approved 04/30/2024 BUILDING 2 EXISTING EXTERIOR ELEVATIONS AD2.04 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING WEST ELEVATION BUILDING - 2 1/4" = 1'-0"1 SOUTH ELEVATION BUILDING - 2 1/4" = 1'-0"2 TOP OF PLATE 2 ND FLOOR 1 ST FLOOR TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 0+20' 11-3/4" 0+12' 11-1/4" 0+4' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 0+16' 11-3/4" 0+8' 11-1/4" 0+0' 0" 0+16' 11-3/4" 0+8' 11-1/4" 0+0' 0" EXISTING FLASH UP 4" BEHIND SIDING TYPICAL AT JUNCTION OF SIDING AND ROOFING EXISTING FLASH UP 4" BEHIND SIDING TYPICAL AT JUNCTION OF SIDING AND ROOFING EXISTING, ROUGH-SAWN 5/8" CEDAR TEXTURED FACE T-111 PLYWOOD Approved 04/30/2024 BUILDING 1 EXTERIOR ELEVATIONS A2.01 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING EAST ELEVATION BUILDING - 1 1/4" = 1'-0"1 NORTH ELEVATION BUILDING - 1 1/4" = 1'-0"2 JAMES HARDIE PAINTED 6" SHINGLE SIDING - STRAIGHT EDGE PANEL JAMES HARDIE PAINTED 6" PLANK LAP SIDING JAMES HARDIE PAINTED 8" PLANK LAP SIDING SMOOTH JAMES HARDIE PAINTED TRIM 5/4 SMOOTH - WHITE 1 2 3 4 1 1 1 2 2 2 2 2 3 3 1 1 3 3 3 2 2 4 4 4 4 4 4 4 TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" 16' 11-3/4" 8' 11-1/4" 0' 0" EXISTING CONCRETE FUNDATION EXISTING CONCRETE FUNDATION 3 SIDING TYPES TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 2 2 A7.01 6 A7.01 5 A7.01 4 A7.01 3 A7.01 8 A7.02 3 A7.01 9 A7.01 8 A7.02 2 A7.01 9 A7.02 2 6 6 6 6 6 A7.01 7 A7.02 2 A7.02 2 9 9 9 9 A7 . 0 1 11 4 4 10 10 A7.01 5 A7.01 4 1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS . 2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS. 3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS. 4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT. 5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR ALL EXISTING CONDITIONS. 6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS. 7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS. REFER ENLARGED DETAILS. 8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP THROUGHOUT. 9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT. 10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS. RE-CLADDING NOTES Approved 04/30/2024 1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS . 2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS. 3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS. 4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT. 5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR ALL EXISTING CONDITIONS. 6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS. 7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS. REFER ENLARGED DETAILS. 8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP THROUGHOUT. 9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT. 10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS. RE-CLADDING NOTES BUILDING 1 EXTERIOR ELEVATIONS A2.02 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING WEST ELEVATION BUILDING - 1 1/4" = 1'-0"1 SOUTH ELEVATION BUILDING - 1 1/4" = 1'-0"2 1 1 1 1 1 222 2 3 3 3 22222 2 2 3 3 4 TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 4 4 SIDING TYPES 1 2 3 4 16' 11-3/4" 8' 11-1/4" 0' 0" 6 6 6 6 6 6 JAMES HARDIE PAINTED 6" SHINGLE SIDING - STRAIGHT EDGE PANEL JAMES HARDIE PAINTED 6" PLANK LAP SIDING JAMES HARDIE PAINTED 8" PLANK LAP SIDING SMOOTH JAMES HARDIE PAINTED TRIM 5/4 SMOOTH - WHITE 5 1 A7.02 3 9 9 9 4 4 4 4 4 4 4 4 A7 . 0 1 11 10 A7.01 5 A7.01 4 A7.01 4 A7.01 4 Approved 04/30/2024 BUILDING-2 EXTERIOR ELEVATIONS A2.03 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING EAST ELEVATION BUILDING - 2 1/4" = 1'-0"1 NORTH ELEVATION BUILDING - 2 1/4" = 1'-0"2 1 1 2 2 1 1 3 2 2 4 4 4 4 EXISTING CONCRETE FUNDATION EXISTING CONCRETE FUNDATION EXISTING CONCRETE FUNDATION TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 20' 11-3/4" 12' 11-1/4" 4' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 0+20' 11-3/4" 0+12' 11-1/4" 0+4' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" SIDING TYPES 1 2 3 4 6 6 6 6 JAMES HARDIE PAINTED 6" SHINGLE SIDING - STRAIGHT EDGE PANEL JAMES HARDIE PAINTED 6" PLANK LAP SIDING JAMES HARDIE PAINTED 8" PLANK LAP SIDING SMOOTH JAMES HARDIE PAINTED TRIM 5/4 SMOOTH - WHITE 45 1 9 9 9 10 10 A7.01 5 A7.01 4 A7.01 5 A7.01 4 1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS . 2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS. 3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS. 4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT. 5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR ALL EXISTING CONDITIONS. 6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS. 7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS. REFER ENLARGED DETAILS. 8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP THROUGHOUT. 9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT. 10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS. RE-CLADDING NOTES Approved 04/30/2024 BUILDING-2 EXTERIOR ELEVATIONS A2.04 SCALE: AS NOTED 0 PLAN NORTH TRUE NORTH 8' ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING WEST ELEVATION BUILDING - 2 1/4" = 1'-0"1 SOUTH ELEVATION BUILDING - 2 1/4" = 1'-0"2 1 1 1 1 2 2 2 1 1 3 3 4 4 4 4 4 4 EXISTING CONCRETE FUNDATION EXISTING CONCRETE FUNDATION TOP OF PLATE 2 ND FLOOR 1 ST FLOOR TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 20' 11-3/4" 12' 11-1/4" 4' 0" TOP OF PLATE 2 ND FLOOR 1 ST FLOOR 16' 11-3/4" 8' 11-1/4" 0' 0" SIDING TYPES 1 2 3 4 16' 11-3/4" 8' 11-1/4" 0' 0" 4 4 44 6 6 6 6 JAMES HARDIE PAINTED 6" SHINGLE SIDING - STRAIGHT EDGE PANEL JAMES HARDIE PAINTED 6" PLANK LAP SIDING JAMES HARDIE PAINTED 8" PLANK LAP SIDING SMOOTH JAMES HARDIE PAINTED TRIM 5/4 SMOOTH - WHITE 4 9 9 9 9 A7 . 0 1 11 10 10 10 A7.01 5 A7.01 4 A7.01 5 A7.01 4 1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS . 2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS. 3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS. 4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT. 5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR ALL EXISTING CONDITIONS. 6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS. 7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS. REFER ENLARGED DETAILS. 8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP THROUGHOUT. 9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT. 10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS. RE-CLADDING NOTES Approved 04/30/2024 RE-CLADDING DETAILS/ EXISTING PHOTOS A3.01 ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING BUILDING - 1 WEST-SOUTH 1/4" = 1'-0"1 BUILDING - 2 NORTH-WEST 1/4" = 1'-0"4 BUILDING - 2 WEST-SOUTH 1/4" = 1'-0"5 BUILDING - 2 EAST-SOUTH 1/4" = 1'-0"6 BUILDING - 1 NORTH-EAST 1/4" = 1'-0"2 BUILDING - 1 SOUTH 1/4" = 1'-0"3 8 8 8 8 7 7 7 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 5 5 5 4 4 4 4 3 3 2 2 2 22 1 1 1 1 1 1 1 9 9 9 9 9 9 1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS . 2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS. 3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS. 4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT. 5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR ALL EXISTING CONDITIONS. 6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS. 7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS. REFER ENLARGED DETAILS. 8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP THROUGHOUT. 9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT. 10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS. RE-CLADDING NOTES Approved 04/30/2024 EXTERIOR DETAILS A7.01 SCALE: AS NOTED ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING A7.02 4 A7.02 5 A7.02 6 A7.02 7 A7.01 3 NEW 1 x TRIM MATERIAL AT INTERSECTION OF SIDING / SOFFIT NEW PAINTED SOFFIT MATERIAL. DEPTH VARIES, 2'-6" TYPICAL. MATCH EXISTING DEPTH THROUGHOUT. NEW SIDING PER WALL ASSEMBLY 4 TYPICAL EAVE DETAIL NEW WEATHER RESISTIVE BARRIER FASCIA AND GUTTER OUTSIDE OF SCOPE OF PROJECT. SCALE: 3"=1'-0" EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. EXISTING SOFFIT PANEL TO BE REMOVED AND REPLACED WITH NEW VENTED, FIBER CEMENT SOFFIT PANEL. 2 1 / 2 " 2'-6" (E) BLOCKING TO REMAIN SCALE: 3"=1'-0"3 TYPICAL BELLYBAND DETAIL NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) NEW WEATHER RESISTIVE BARRIER 1/2" PRESSURE TREATED PLYWOOD NAILER 1 x 7 1/4 PAINTED FIBER CEMENT TRIM; TERMINATE VERTICAL CORNER TRIM BOARDS INTO HORIZONTAL TRIM SHEET METAL FLASING EXTEND DOWN HEAD TRIM 3/4" MIN, WITH DRIP EDGE NEW SIDING RE: EXTERIOR ELEVATION FOR TYPE) NEW PAINTED SOFFIT MATERIAL RAKE DEPTH VARIES, 2'-6" TYPICAL. MATCH EXISTING DEPTH THROUGHOUT. NEW SIDING PER WALL ASSEMBLY SCALE: 3"=1'-0"5 TYPICAL RAKE DETAIL NEW WEATHER RESISTIVE BARRIER 2 1 / 2 " 2'-6" (E) FRAMING SERVE AS SOFFIT NAILER PROVIDE (N) FIBER CEMENT TRIM EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. SCALE: 3"=1'-0"2 TYPICAL PLANK SIDING DETAIL NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) NEW WEATHER RESISTIVE BARRIER MIN. 1-1/4" OVERLAP 3 1 / 2 " 3 1/2" 9 TYPICAL DOOR TRIM ELEVATION SCALE: 1 1/2"=1'-0" 1 X TRIM AS NEEDED TO MEET EXTERIOR FLOOR SURFACE, HOLD 1/2" OFF CONCRETE AND SEAL JOINT. PAINTED FIBER CEMENT TRIM PAINTED FIBER CEMENT TRIM NEW SIDING (RE: EXTERIOR ELEVATION FOR TYPE) 1/2" PRE-FINISHED METAL FLASHING SET IN ROOFING CEMENT STARTER STRIP SCALE: 3"=1'-0"6 HEADWALL FLASHING DETAIL NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. 3 1 / 2 " 3 1/2" 3 1 / 2 " 8 TYPICAL WINDOW TRIM ELEVATION SCALE: 1 1/2"=1'-0" NEW SIDING (RE: EXTERIOR ELEVATION FOR TYPE) PAINTED FIBER CEMENT TRIM PAINTED FIBER CEMENT TRIM 1/2" SCALE: 3"=1'-0"7 WALL BASE STARTER STRIP SLAB NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) NEW WEATHER RESISTIVE BARRIER SELF ADHERED BITUMINOUS FLASHING TAPE TO SEAL PLYWOOD / CONCRETE INTERSECTION. UNDER WRB AND METAL FLASHING. 24 GA PREFINISHED MTL BASE FLASHING WITH DRIP EDGE, LAP WRB OVER FLASHING. SCALE: 3"=1'-0"1 NEW WEATHER RESISTIVE BARRIER TYPICAL SHINGLE SIDING DETAIL EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) 10 LIGHT FIXTURE BLOCKING ELEVATION SCALE: 1 1/2"=1'-0" REINSTALL EXISTING LIGHT FIXTURE CENTERED ON NEW BLOCKING 1' - 0 " 1'-0" 54 FIBER CEMENT BOARD PAINTED TO MATCH ADJACENT SIDING. NOTCH BOTTOM OF BLOCKING 1 2" FOR SIDING UNDERNEATH NOTE: THIS BLOCKING DETAIL IS TYPICAL FOR ALL WALL MOUNTED VENTS, LIGHT FIXTURES, F.E.C. AND OTHER FIXTURES / ACCESSORIES. MOUNT DOORBELLS TO SIDING (NO BLOCKING NECESSARY). WHERE FIXTURE IS LARGER, EXTEND BLOCKING 3" BEYOND WIDTH / HEIGHT OF FIXTURE. PAINT (E) PLYWOOD SOFFIT NEW SIDING PER WALL ASSEMBLY SCALE: 3"=1'-0"11 BUMPOUT SOFFIT DETAIL NEW WEATHER RESISTIVE BARRIER 2 1 / 2 " 1 x 7 1/4 PAINTED FIBER CEMENT TRIM; WRAP CORNERS. 1 1/2" 1/ 2 " PROVIDE (N) FIBER CEMENT TRIM SHEET METAL FLASING EXTEND DOWN HEAD TRIM 3/4" MIN, WITH DRIP EDGE Approved 04/30/2024 EXTERIOR DETAILS A7.02 SCALE: AS NOTED ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING A7.0 2 8 SCALE: 3"=1'-0"1 INSIDE CORNER SHINGLE/PLANK DETAIL EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. EXISTING WALL FRAMING AND INSULATION TO REMAIN. NEW WEATHER RESISTIVE BARRIER NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) SHEET METAL 90° INTERNAL " W " MOULD NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) SCALE: 3"=1'-0"2 OUTSIDE CORNER PLANK DETAIL HARDIE PLANK LAP SIDING LEAVE APPROPIATE GAP AND CAULK HARDIE TRIM BOARDS PAINTED TO MATCH ADJACENT TRIMLEAVE APPROPIATE GAP AND CAULK NEW WEATHER RISISTIVE BARRIER HARDIE PLANK LAP SIDING EXTERIOR SHEATING EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. EXISTING WALL FRAMING AND INSULATION TO REMAIN. 3 1 / 2 " 3 1/2" SCALE: 3"=1'-0"3 OUTSIDE CORNER SHINGLE DETAIL NEW WEATHER RISISTIVE BARRIER HARDIE SHINGLE LAP SIDING EXTERIOR SHEATING HARDIE SHINGLE SIDING EXISTING EXTERIOR BUILDING MATERIALS AND FINISHES TO BE REMOVED TO EXPOSE BARE PLYWOOD SHEATHING. REPAIR OR REPLACE AS REQUIRED TO RECEIVE NEW WRB AND SIDING. EXISTING WALL FRAMING AND INSULATION TO REMAIN. LEAVE APPROPIATE GAP AND CAULK HARDIE TRIM BOARDS PAINTED TO MATCH ADJACENT TRIMLEAVE APPROPIATE GAP AND CAULK 3 1 / 2 " 3 1/2" NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) SCALE: 3"=1'-0" TYP. WINDOW HEAD BACKER ROD & SEALANT 4 PAINTED FIBER CEMENT TRIM SEE 1/7.01, 2/7.01 FOR WALL CONSTRUCTION EXISTING WINDOW AND INTERIOR TRIM TO REMAIN BACKER ROD & SEALANT SCALE: 3"=1'-0" TYP. WINDOW JAMB EXISTING WINDOW AND INTERIOR TRIM TO REMAIN 5 PAINTED FIBER CEMENT TRIM SEE 1/7.01, 2/7.01 FOR WALL CONSTRUCTION NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) SCALE: 3"=1'-0" TYP. DOOR HEAD PAINTED FIBER CEMENT TRIM JAMES HARDIE TRIM OR NEW SIDING (SEE EXTERIOR ELEVATIONS) 6 SEE 1/7.01, 2/7.01 FOR WALL CONSTRUCTION EXISTING DOOR AND INTERIOR TRIM TO REMAIN PAINTED FIBER CEMENT TRIM SCALE: 3"=1'-0" TYP. DOOR JAMB7 NEW SIDING (RE:EXTERIOR ELEVATION FOR TYPE) EXISTING DOOR AND INTERIOR TRIM TO REMAIN SEE 1/7.01, 2/7.01 FOR WALL CONSTRUCTION 8 OUTLOOKER ROT REPAIR AND FLASHING INCLUDE SHEET METAL FLASHING END CAP AT GABLE ENDS. SCALE: 3"=1'-0" REPAIR WOOD ROT ON BEAM AND BLOCKING WITH SYSTEMTHREE ENDROT KIT WITH Sculpwood Max Putty FOR STRUCTURAL REPAIR. ATTACHMENT CLEAT AT UNDER TOP CAP VERTICAL WRAP FLASHING ON BEAM HORIZONTAL FLASHING WITH CLEAT Approved 04/30/2024 PAINT SCHEME PERSPECTIVES A8.01 ANACORTES C 2014 REV ISSUED FOR DATE PROJECT No: 202301.01 DRAWN BY: CHECKED BY: DATE ISSUED:04.29.2024 209 Prospect Street Bellingham, WA 98225 360.734.4744 PERMIT SET ARCHITECTURE | INTERIOR DESIGN zervasgroup.com SITE ONE RE-CLADDING BUILDING - 1 PERSPECTIVE N.T.S.1 BUILDING - 2 PERSPECTIVE N.T.S.4 BUILDING - 2 PERSPECTIVE N.T.S.5BUILDING - 1 PERSPECTIVE N.T.S.2 BUILDING - 1 PERSPECTIVE N.T.S.3 BUILDING - 2 PERSPECTIVE N.T.S.6 NOTE: REFER TO ALL OTHER SHEETS FOR DETAILS AND MATERIAL LOCATION. THESE RENDERINGS ARE SHOWN FOR GENERAL DESING REFERENCE AND PAINTING SCHEME ONLY. Approved 04/30/2024