HomeMy WebLinkAboutBLD-2024-0322 - WINDOWS/DOORS/SIDING NEW OR REPLACEDFor inspections, please call (360) 293-1901
PARCEL: P56826
LEGAL DESCRIPTION:
APPLICANT: Newhard, Zachary
209 Prospect St #1
Bellingham, WA 98225
360.390.5847
OWNER: HOUSING AUTHORITY OF ANACORTES
UNKNOWN
ANACORTES, WA 98221
VALUATIONS:
SIDING SQUARE
FOOTAGE NEW OR
REPLACED
9440.00 $84,960.00
$84,960.00Total:
FEES:Paid Due
BUILDING PERMIT FEE
WINDOWS/DOORS/SIDING
$888.75 $0.00
PLAN REVIEW FEE WINDOWS
DOORS SIDING
$577.69 $0.00
State Building Code Council fee $25.00 $0.00
$0.00Totals :
REQUIRED INSPECTIONS
Fenestration U-Factors
HOUSEWRAP/FLASHING
Windows/Siding/Doors Final
$1,491.44
BLD-2024-0322 WINDOWS/DOORS/SIDING NEW OR
REPLACED
ISSUED:
EXPIRES:
10/24/2024
10/24/2026
PROJECT NAME: AHA SITE 1 RECLADDING
SITE ADDRESS: 508-511 6TH & T AV ANACORTES
Page 1 of 1Printed by : Cheri Gleichmann on: 11/13/2024 01:34 PM
City of Anacortes, WA
904 6th Street
Anacortes, WA 98221
(360) 293-1901
http://cityofanacortes.org/
SITE ONE RE-CLADDING
511 AVENUE, ANACORTES 98221
PERMIT SET
SITE
CITY OF ANACORTES
PLANNING AND BUILDING DEPT:
APPROVED PLANS
REVIEWED FOR CODE COMPLIANCE
PERMIT #:______________________________
ADDRESS:____ _______________
APPROVED BY: ______________
SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT
BE ALTERED WITHOUT AUTHORIZATION.
BLD-2024-0322
508-511 T Avenue
Approved
04/30/2024
INDEX / PROJECT
INFORMATION
G0.01
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ARROW
CENTERLINE
PLAN NORTH
TRUE NORTH
NORTH
ARROWS
GRID HEAD
WALL TAG
FLOOR TAG
ROOF TAG
CEILING TAG
INTERIOR WALL TAG
A.H.U.
ALT.
A.V.
BLDG.
DIA.
D.S.
(E)
EF
EH
0
WL-X
FL-X
RF-X
CL-X
1' - 0" A.F.F.
X
DOOR #
WL-X
FL-X
RF-X
ELECT.
ELEV.
EQ
CL-X
1' - 0" A.F.F.
EXIST.
EXT.
F.E.
F.E.C
F.F
FIN.
G.A.
G.L.B.
G.W.B.
HR.
INSUL.
INT.
DOOR TAG
WINDOW TAG
ROOM TAGS
101
00 HARDWARE GROUP
X
Room name
101
Room name
101
INTERIOR PLANSW S
EXTERIOR
CLADDING TAG
EXTERIOR
ELEVATION TAG
1
TYPE X
Ref
A101
1
1
Ref
REVISION TAG
1
MECH.
MIN.
MISC.
MTL.
(N)
O.C.
O.D.
O.F.C.C.
O.F.C.I.
P.L.
P.T.
REF.
REQ'D
RM.
RWL.
SCHED.
SHT.
SIM.
S.S.
ST.
STL.
1
SPOT
ELEVATION
(USED WHEREVER
THERE IS NO REVISION
CLOUD)
STRUCT.
T.O.
T.O.B.
T.O.S.
T.S.
TYP.
U.N.O.
V
V.I.F.
W/
W/O
@
&
AIR HANDLING UNIT
ALTERNATE
AUDIO / VISUAL
BUILDING
DIAMETER
DOWNSPOUT
EXISTING
EXHAUST FAN
EXHAUST HOOD
ELECTRICAL
ELEVATION
EQUAL
EXISTING
EXTERIOR
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR
FINISH
GAUGE
GLUE LAMINATED BEAM
GYPSUM WALLBOARD
HOUR
INSULATION
INTERIOR
MECHANICAL
MINIMUM
MISCELLANEOUS
METAL
NEW
ON CENTER
OVERFLOW DRAIN
OWNER FURNISHED CONTRACTOR COORDINDATED
OWNER FURNISHED CONTRACTOR INSTALLED
PROPERTY LINE
PRESSURE TREATED
REFERENCE
REQUIRED
ROOM
RAINWATER LEADER
SCHEDULE
SHEET
SIMILAR
STAINLESS STEEL
STREET
STEEL
STRUCTURAL
TOP OF
TOP OF BEAM
TOP OF SLAB
TUBE STEEL
TYPICAL
UNLESS NOTED OTHERWISE
VENT PIPE
VERIFY IN FIELD
WITH
WITHOUT
AT
AND
Re
f
Re
f
ARCHITECTURAL ABBREVIATIONSARCHITECTURAL SYMBOLS
ARCHITECTS
ZERVAS
209 PROSPECT STREET
BELLINGHAM, WA 98225
PH: (360) 734-4744
CONTACT: ZACH NEWHARD
ZACH@ZERVASGROUP.COM
ANACORTES HOUSING
AUTHORITY
719 Q AVE
ANACORTES, WA 98221
PH: (360) 293-7831
CONTACT: SNADY COX
DESIGN TEAM
OWNER
SITE ADDRESS :
511 T AVENUE, Anacortes 98221
PARCEL #:
P56826 SITE INFORMATION
SITE ADDRESS:
PROJECT
SITE
4th St
2021 IEBC ANALYSIS
THE FOLLOWING IS A PARTIAL LISTING OF REQUIREMENTS, ALL APPLICABLE CODES TO APPLY
PROJECT SHALL COMPLY WITH 2021 IEBC, STATE AND LOCAL CODES.
ROOF FIRE CLASSIFICATION: CLASS C PER TABLE 1505.1
UL CLASS A
IEBC - CHAPTER 7 ALTERATIONS - LEVEL 1
VICINITY MAP
PROJECT DESCRIPTION / NARRATIVE
SITE ONE RECLADDING IS APPROXIMATELY 9,440 SQUARE FEET OF SIDING
ON TWO ADJACENT SEPARATE BUILDING ON THE SAME SITE. WORK WILL INCLUDE
COMPLETE TEAR OFF TO EXPLOSE WALL SHEATHING.
INSTALLATION OF NEW UNDERLAYMENT, SIDING, AND ASSOCIATED FLASHINGS.
NOT TO SCALE
NORTH
PARCEL #
LEGAL DESCRIPTION:
511 T AVENUE, Anacortes 98221
P56826
(0.6900 ac) LOTS 11 THROUGH 20, BLOCK 12,
BOWMAN'S CENTRAL SHIP HARBOR WATERFRONT PLAT OF
ANACORTES, AS PER PLAT RECORDED IN VOLUME 2 OF PLATS, PAGE
33, RECORDS OF SKAGIT COUNTY, WASHINGTON. SURVEY AF#
201004210001
GENERAL NOTES:
1. PRIOR TO COMMENCEMENT OF WORK COORDINATE WITH OWNER CONSTRUCTION STAGING, ACCESS, AND
MAJOR DELIVERIES.
2. PROTECT LANDSCAPING, LAWN AREAS AND PAVERS. LAY DOWN TRIM BOARDS OVER LAWN AND PAVER
AREAS PRIOR TO TRAVERSING OR PARKING MAN/MATERIAL LIFTS. RESTORE LANDSCAPING, CLEAN TRACK/TIRE
MARKS FROM SIDEWALKS.
3. PROVIDE TEMPORARY FENCE ENCLOSURES AND SAFETY BARRIERS FOR:
A. MATERIAL STAGING AREAS
B. AREAS THAT MATERIAL/MAN LIFTS ARE CONTINUOUSLY OPERATING IN.
C. PEDESTRIAN WALKWAYS THAT ARE WITHIN 10' OF ROOF EDGE (WHEN WORK IS BEING PERFORMED).
STAGING AREA AND PARKING TO BE
COORDINATED WITH THE
ANACORTES HOUSING AUTHORITY
OWNER AND RESIDENT ACCESS TO
THIS ENTRY/EXIT MUST BE
MAINTAINED THROUGH DURATION
OF CONSTRUCTION
OWNER AND RESIDENT ACCESS TO
THIS ENTRY/EXIT MUST BE
MAINTAINED THROUGH DURATION
OF CONSTRUCTION
STAGING AREA AND PARKING TO BE
COORDINATED WITH THE
ANACORTES HOUSING AUTHORITY
PLAYGROUND
CONTRACT LIMITS AND STAGING
CO
M
M
E
R
C
I
A
L
S
t
AD-2.01
ARCHITECTURE
BUILDING 1 EXISTING EXTERIOR ELEVATIONS
DRAWING INDEX
GENERAL
G0.00
G0.01
COVER
INDEX / PROJECT INFORMATION
AD-2.02 BUILDING 1 EXISTING EXTERIOR ELEVATIONS
AD-2.03 BUILDING 2 EXISTING EXTERIOR ELEVATIONS
AD-2.04 BUILDING 2 EXISTING EXTERIOR ELEVATIONS
A-2.01 BUILDING 1 EXTERIOR ELEVATIONS
A-2.02 BUILDING 1 EXTERIOR ELEVATIONS
A-2.03 BUILDING 2 EXTERIOR ELEVATIONS
A-1.01 SITE PLAN
A-2.04 BUILDING 2 EXTERIOR ELEVATIONS
A-7.01 EXTERIOR DETAILS
A-7.02 EXTERIOR DETAILS
A-3.01 RE-CLADDING DETAILS / EXISTING PHOTOS
A-8.01 PAINT SCHEME PERSPECTIVES
Approved
04/30/2024
SITE PLAN
A1.01
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
SITE PLAN
3/32" = 1'-0"1
17
'
-
6
"
28
'
-
4
"
13
'
-
0
"
36
'
-
0
"
17
'
-
6
"
9'
-
6
"
53'-0"
9'-
0
"
7'
-
0
"
78'-8"28'-4"
67
'
-
4
"
37'-4"
1 ST FL. ELEV. = 100.0'
4'-0"
BUILDING #1
1 ST FL. ELEV. = 113.0'
BUILDING #2
1 ST FL. ELEV. = 118.0'
99
'
-
1
0
"
8'
-
0
"
4'-
0
"
8'
-
0
"
12
'
-
0
"
13
'
-
0
"
14'-0"24'-0"6'-0"78'-8"7'-0"28'-4"20'-0"
90°
12'-0"18'-0"56'-0"
12'-0"27'-0"62'-4"45'-0"28'-0"28'-4"7'-0"
28
'
-
4
"
8'-
0
"
24
'
-
0
"
12
'
-
6
"
6'
-
0
"
8'-
0
"
4'-0"
3'-
6
"
12
'
-
6
"
4'
-
0
"
9'
-
0
"
12
'
-
0
"
4'-0"8'-0"
4'
-
0
"
4'
-
0
"
4'
-
0
"
9'-0"
4'-0"
6'-0"
4'-0"
9'-0"
PARKING AREA
ASPHALT
PLAY AREA
ASPHALT
DRYING MAINT.
SCREEN FENCING
4'-0"
12'-0"13'-8"32'-0"10'-4"
PARKING AREA
ASPHALT
DR
Y
I
N
G
GA
R
B
.
GA
R
B
.
36'-0"
Approved
04/30/2024
BUILDING 1
EXISTING EXTERIOR
ELEVATIONS
AD2.01
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
EAST ELEVATION BUILDING - 1
1/4" = 1'-0"1
NORTH ELEVATION BUILDING - 1
1/4" = 1'-0"2
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
16'
11-3/4"
8' 11-1/4"
0' 0"
TOP OF
PLATE
2 ND
FLOOR
1 ST
FLOOR
EXISTING, ROUGH-SAWN
5/8" CEDAR TEXTURED
FACE T-111 PLYWOOD
EXISTING
2" Ø G. I. DOWNSPOUTS
(TYPICAL)
EXISTING, ROUGH-SAWN
5/8" CEDAR TEXTURED
FACE T-111 PLYWOOD
12"
4-1/2"
Approved
04/30/2024
EXISTING
2" Ø G. I.
DS (TYP.)
EXISTING
2 SQ. FT.
MINIMUM
SCREENED
LOUVER
(TYPICAL)
EXISTING
1 X 12
FASCIA
BOARD
12"
4-1/2"
EXISTING, ROUGH-SAWN
5/8" CEDAR TEXTURED
FACE T-111 PLYWOOD
BUILDING 1
EXISTING EXTERIOR
ELEVATIONS
AD2.02
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
WEST ELEVATION BUILDING - 1
1/4" = 1'-0"1
SOUTH ELEVATION BUILDING - 1
1/4" = 1'-0"2
TOP OF
PLATE
2 ND FLOOR
1 ST FLOOR
TOP OF
PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
16'
11-3/4"
8' 11-1/4"
0' 0"
Approved
04/30/2024
BUILDING 2
EXISTING EXTERIOR
ELEVATIONS
AD2.03
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
EAST ELEVATION BUILDING - 2
1/4" = 1'-0"1
NORTH ELEVATION BUILDING - 2
1/4" = 1'-0"2
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
20' 11-3/4"
12' 11-1/4"
4' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
20' 11-3/4"
12' 11-1/4"
4' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
4
EXISTING, ROUGH-SAWN
5/8" CEDAR TEXTURED
FACE T-111 PLYWOOD
EXISTING
2" Ø G. I.
DOWNSPOUTS
(TYPICAL)
EXISTING
2 SQ. FT. MINIMUM
SCREENED LOUVER
(TYPICAL)
EXISTING
FLASH UP 4" BEHIND
SIDING TYPICAL AT
JUNCTION OF SIDING
AND ROOFING
EXISTING
5/8" CEDAR SAW TEXTURED
FACE T-111 PLYWOOD
EXISTING
2" Ø G. I. DOWNSPOUTS
(TYPICAL)
12"
4-1/2"
Approved
04/30/2024
BUILDING 2
EXISTING EXTERIOR
ELEVATIONS
AD2.04
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
WEST ELEVATION BUILDING - 2
1/4" = 1'-0"1
SOUTH ELEVATION BUILDING - 2
1/4" = 1'-0"2
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
0+20' 11-3/4"
0+12' 11-1/4"
0+4' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
0+16' 11-3/4"
0+8' 11-1/4"
0+0' 0"
0+16' 11-3/4"
0+8' 11-1/4"
0+0' 0"
EXISTING
FLASH UP 4" BEHIND
SIDING TYPICAL AT
JUNCTION OF SIDING
AND ROOFING
EXISTING
FLASH UP 4" BEHIND
SIDING TYPICAL AT
JUNCTION OF SIDING
AND ROOFING
EXISTING, ROUGH-SAWN
5/8" CEDAR TEXTURED
FACE T-111 PLYWOOD
Approved
04/30/2024
BUILDING 1
EXTERIOR
ELEVATIONS
A2.01
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
EAST ELEVATION BUILDING - 1
1/4" = 1'-0"1
NORTH ELEVATION BUILDING - 1
1/4" = 1'-0"2
JAMES HARDIE PAINTED 6"
SHINGLE SIDING - STRAIGHT
EDGE PANEL
JAMES HARDIE PAINTED 6"
PLANK LAP SIDING
JAMES HARDIE PAINTED 8"
PLANK LAP SIDING SMOOTH
JAMES HARDIE PAINTED TRIM
5/4 SMOOTH - WHITE
1
2
3
4
1 1
1
2 2 2 2
2
3
3
1
1
3
3
3
2 2
4 4
4 4 4 4 4
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
16'
11-3/4"
8' 11-1/4"
0' 0"
EXISTING CONCRETE FUNDATION
EXISTING CONCRETE FUNDATION
3
SIDING TYPES
TOP OF
PLATE
2 ND FLOOR
1 ST FLOOR
2
2
A7.01
6
A7.01
5
A7.01
4
A7.01
3
A7.01
8
A7.02
3
A7.01
9
A7.01
8
A7.02
2
A7.01
9
A7.02
2
6
6
6
6
6
A7.01
7
A7.02
2
A7.02
2
9
9
9 9
A7
.
0
1
11
4
4
10
10
A7.01
5
A7.01
4
1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE
PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING
CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS .
2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS.
3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS.
4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT.
5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR
ALL EXISTING CONDITIONS.
6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO
SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS.
7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS.
REFER ENLARGED DETAILS.
8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP
THROUGHOUT.
9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT.
10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS.
RE-CLADDING NOTES
Approved
04/30/2024
1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE
PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING
CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS .
2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS.
3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS.
4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT.
5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR
ALL EXISTING CONDITIONS.
6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO
SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS.
7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS.
REFER ENLARGED DETAILS.
8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP
THROUGHOUT.
9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT.
10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS.
RE-CLADDING NOTES
BUILDING 1
EXTERIOR
ELEVATIONS
A2.02
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
WEST ELEVATION BUILDING - 1
1/4" = 1'-0"1
SOUTH ELEVATION BUILDING - 1
1/4" = 1'-0"2
1 1
1
1 1
222 2
3
3
3
22222
2
2
3
3
4
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
TOP OF
PLATE
2 ND FLOOR
1 ST FLOOR
4 4
SIDING TYPES
1
2
3
4
16' 11-3/4"
8' 11-1/4"
0' 0"
6
6
6
6
6
6
JAMES HARDIE PAINTED 6"
SHINGLE SIDING - STRAIGHT
EDGE PANEL
JAMES HARDIE PAINTED 6"
PLANK LAP SIDING
JAMES HARDIE PAINTED 8"
PLANK LAP SIDING SMOOTH
JAMES HARDIE PAINTED TRIM
5/4 SMOOTH - WHITE
5
1
A7.02
3
9
9
9
4
4
4
4
4
4
4
4
A7
.
0
1
11
10
A7.01
5
A7.01
4
A7.01
4
A7.01
4
Approved
04/30/2024
BUILDING-2
EXTERIOR
ELEVATIONS
A2.03
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
EAST ELEVATION BUILDING - 2
1/4" = 1'-0"1
NORTH ELEVATION BUILDING - 2
1/4" = 1'-0"2
1
1
2
2
1
1 3
2
2
4
4
4
4
EXISTING CONCRETE FUNDATION
EXISTING CONCRETE FUNDATION
EXISTING CONCRETE FUNDATION
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
20' 11-3/4"
12' 11-1/4"
4' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
0+20' 11-3/4"
0+12' 11-1/4"
0+4' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
SIDING TYPES
1
2
3
4
6
6
6
6
JAMES HARDIE PAINTED 6"
SHINGLE SIDING - STRAIGHT
EDGE PANEL
JAMES HARDIE PAINTED 6"
PLANK LAP SIDING
JAMES HARDIE PAINTED 8"
PLANK LAP SIDING SMOOTH
JAMES HARDIE PAINTED TRIM
5/4 SMOOTH - WHITE
45
1
9
9
9
10
10
A7.01
5
A7.01
4
A7.01
5
A7.01
4
1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE
PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING
CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS .
2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS.
3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS.
4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT.
5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR
ALL EXISTING CONDITIONS.
6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO
SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS.
7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS.
REFER ENLARGED DETAILS.
8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP
THROUGHOUT.
9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT.
10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS.
RE-CLADDING NOTES
Approved
04/30/2024
BUILDING-2
EXTERIOR
ELEVATIONS
A2.04
SCALE: AS NOTED 0
PLAN NORTH TRUE NORTH
8'
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
WEST ELEVATION BUILDING - 2
1/4" = 1'-0"1
SOUTH ELEVATION BUILDING - 2
1/4" = 1'-0"2
1 1
1
1
2
2
2
1
1
3
3
4 4 4
4
4
4
EXISTING CONCRETE FUNDATION
EXISTING CONCRETE FUNDATION
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
20' 11-3/4"
12' 11-1/4"
4' 0"
TOP OF PLATE
2 ND FLOOR
1 ST FLOOR
16' 11-3/4"
8' 11-1/4"
0' 0"
SIDING TYPES
1
2
3
4
16' 11-3/4"
8' 11-1/4"
0' 0"
4 4 44
6
6
6
6
JAMES HARDIE PAINTED 6"
SHINGLE SIDING - STRAIGHT
EDGE PANEL
JAMES HARDIE PAINTED 6"
PLANK LAP SIDING
JAMES HARDIE PAINTED 8"
PLANK LAP SIDING SMOOTH
JAMES HARDIE PAINTED TRIM
5/4 SMOOTH - WHITE
4
9
9
9
9
A7
.
0
1
11
10
10 10
A7.01
5
A7.01
4
A7.01
5
A7.01
4
1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE
PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING
CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS .
2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS.
3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS.
4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT.
5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR
ALL EXISTING CONDITIONS.
6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO
SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS.
7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS.
REFER ENLARGED DETAILS.
8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP
THROUGHOUT.
9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT.
10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS.
RE-CLADDING NOTES
Approved
04/30/2024
RE-CLADDING
DETAILS/
EXISTING PHOTOS
A3.01
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
BUILDING - 1 WEST-SOUTH
1/4" = 1'-0"1
BUILDING - 2 NORTH-WEST
1/4" = 1'-0"4 BUILDING - 2 WEST-SOUTH
1/4" = 1'-0"5 BUILDING - 2 EAST-SOUTH
1/4" = 1'-0"6
BUILDING - 1 NORTH-EAST
1/4" = 1'-0"2 BUILDING - 1 SOUTH
1/4" = 1'-0"3
8
8
8
8
7 7 7
6
6
6
6
6 6
6
6
6
6
6
6
6
6
6
6
5
5
5
4
4
4
4
3
3
2
2
2
22
1
1
1
1
1
1
1
9
9
9
9
9
9
1 REPLACE EXISTING EXTERIOR SIDING WITH NEW. REMOVE EXISTING VINYL SIDING AND T-111 PLYWOOD SIDING TO EXPOSE
PLYWOOD SHEATHING. PREPARE SHEATHING AS NECESSARY FOR INSTALLATION OF NEW MATERIALS. TYPICAL FOR ALL EXISTING
CONDITIONS. REFER TO SIDING TYPES AND ENLARGED DETAILS .
2 REMOVE AND REPLACE SEALANT AT EXISTING WINDOWS. TYPICAL FOR ALL EXISTING CONDITIONS.
3 SALVAGE AND REINSTALL DOORBELLS AT SAME LOCATION. TYPICAL FOR ALL EXISTING CONDITIONS.
4 EXISTING BALCONIES TO REMAIN, REPAINT / REFINISH ALL ELEMENTS TO MATCH SIDING 1 THROUGHOUT.
5 INSTALL NEW SIDING WITH JOINTS WHERE METERS PENETRATE WALL AND FULLY SEAL AROUND PENETRATIONS. TYPICAL FOR
ALL EXISTING CONDITIONS.
6 PROVIDE PAINTED FIBER CEMENT TRIM AT ALL INSIDE AND OUTSIDE CORNERS AND AS SHOWN IN ENLARGED DETAILS. REFER TO
SIDING TYPES. TYPICAL FOR ALL EXISTING CONDITIONS.
7 REPLACE EXISTING SOFFIT PANELS WITH NEW PAINTED, VENTED FIBER CEMENT SOFFIT TYPICAL FOR ALL EXISTING CONDITIONS.
REFER ENLARGED DETAILS.
8 REMOVE AND REINSTALL EXISTING EXTERIOR BUILDING MOUNTED LIGHT FIXTURES ON NEW 54 x 12 x 12 PAINTED BLOCKING, TYP
THROUGHOUT.
9 PAINT (E) PLYWOOD ON UNDERSIDE OF BUMPOUTS AND BREEZEWAY, THROUGHOUT.
10 WRAP EXPOSED WOOD BEAMS IN SHEET METAL FLASHING PER 8/7.02. TYPICAL ALL OUTRIGGER BEAMS.
RE-CLADDING NOTES
Approved
04/30/2024
EXTERIOR
DETAILS
A7.01
SCALE: AS NOTED
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
A7.02
4
A7.02
5
A7.02
6
A7.02
7
A7.01
3
NEW 1 x TRIM MATERIAL AT
INTERSECTION
OF SIDING / SOFFIT
NEW PAINTED SOFFIT MATERIAL.
DEPTH VARIES, 2'-6" TYPICAL. MATCH
EXISTING DEPTH THROUGHOUT.
NEW SIDING PER
WALL ASSEMBLY
4 TYPICAL EAVE DETAIL
NEW WEATHER
RESISTIVE BARRIER
FASCIA AND
GUTTER OUTSIDE
OF SCOPE OF
PROJECT.
SCALE: 3"=1'-0"
EXISTING EXTERIOR BUILDING MATERIALS AND
FINISHES TO BE REMOVED TO EXPOSE BARE
PLYWOOD SHEATHING. REPAIR OR REPLACE AS
REQUIRED TO RECEIVE NEW WRB AND SIDING.
EXISTING SOFFIT PANEL TO BE REMOVED AND
REPLACED WITH NEW VENTED, FIBER CEMENT
SOFFIT PANEL.
2
1
/
2
"
2'-6"
(E) BLOCKING TO REMAIN
SCALE: 3"=1'-0"3 TYPICAL BELLYBAND DETAIL
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR
TYPE)
NEW WEATHER
RESISTIVE BARRIER
1/2" PRESSURE
TREATED PLYWOOD
NAILER
1 x 7 1/4 PAINTED FIBER
CEMENT TRIM;
TERMINATE VERTICAL CORNER
TRIM BOARDS INTO
HORIZONTAL TRIM
SHEET METAL FLASING
EXTEND DOWN HEAD
TRIM 3/4" MIN,
WITH DRIP EDGE
NEW SIDING
RE: EXTERIOR
ELEVATION FOR
TYPE)
NEW PAINTED SOFFIT MATERIAL
RAKE DEPTH VARIES, 2'-6"
TYPICAL. MATCH EXISTING
DEPTH THROUGHOUT.
NEW SIDING PER
WALL ASSEMBLY
SCALE: 3"=1'-0"5 TYPICAL RAKE DETAIL
NEW WEATHER
RESISTIVE BARRIER
2
1
/
2
"
2'-6"
(E) FRAMING
SERVE AS SOFFIT NAILER
PROVIDE (N) FIBER
CEMENT TRIM
EXISTING EXTERIOR BUILDING
MATERIALS AND FINISHES TO BE
REMOVED TO EXPOSE BARE
PLYWOOD SHEATHING. REPAIR OR
REPLACE AS REQUIRED TO RECEIVE
NEW WRB AND SIDING.
SCALE: 3"=1'-0"2 TYPICAL PLANK SIDING DETAIL
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR TYPE)
NEW WEATHER
RESISTIVE BARRIER
MIN. 1-1/4" OVERLAP
3
1
/
2
"
3 1/2"
9 TYPICAL DOOR TRIM ELEVATION
SCALE: 1 1/2"=1'-0"
1 X TRIM AS NEEDED TO MEET
EXTERIOR FLOOR SURFACE,
HOLD 1/2" OFF CONCRETE AND
SEAL JOINT.
PAINTED FIBER
CEMENT TRIM
PAINTED FIBER
CEMENT TRIM
NEW SIDING (RE:
EXTERIOR ELEVATION
FOR TYPE)
1/2"
PRE-FINISHED
METAL FLASHING
SET IN ROOFING CEMENT
STARTER STRIP
SCALE: 3"=1'-0"6 HEADWALL FLASHING DETAIL
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR TYPE)
EXISTING EXTERIOR BUILDING
MATERIALS AND FINISHES TO BE
REMOVED TO EXPOSE BARE
PLYWOOD SHEATHING. REPAIR OR
REPLACE AS REQUIRED TO RECEIVE
NEW WRB AND SIDING.
3
1
/
2
"
3 1/2"
3
1
/
2
"
8 TYPICAL WINDOW TRIM ELEVATION
SCALE: 1 1/2"=1'-0"
NEW SIDING (RE:
EXTERIOR ELEVATION
FOR TYPE)
PAINTED FIBER
CEMENT TRIM
PAINTED FIBER
CEMENT TRIM
1/2"
SCALE: 3"=1'-0"7 WALL BASE
STARTER STRIP
SLAB
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR
TYPE)
NEW WEATHER
RESISTIVE BARRIER
SELF ADHERED BITUMINOUS
FLASHING TAPE TO SEAL
PLYWOOD / CONCRETE
INTERSECTION. UNDER WRB AND
METAL FLASHING.
24 GA PREFINISHED MTL BASE
FLASHING WITH DRIP EDGE,
LAP WRB OVER FLASHING.
SCALE: 3"=1'-0"1
NEW WEATHER
RESISTIVE BARRIER
TYPICAL SHINGLE SIDING DETAIL
EXISTING EXTERIOR BUILDING
MATERIALS AND FINISHES TO BE
REMOVED TO EXPOSE BARE
PLYWOOD SHEATHING. REPAIR OR
REPLACE AS REQUIRED TO RECEIVE
NEW WRB AND SIDING.
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR TYPE)
10 LIGHT FIXTURE BLOCKING ELEVATION
SCALE: 1 1/2"=1'-0"
REINSTALL EXISTING
LIGHT FIXTURE CENTERED
ON NEW BLOCKING
1'
-
0
"
1'-0"
54 FIBER CEMENT BOARD
PAINTED TO MATCH
ADJACENT SIDING.
NOTCH BOTTOM OF
BLOCKING 1
2" FOR SIDING
UNDERNEATH
NOTE: THIS BLOCKING DETAIL IS TYPICAL FOR ALL
WALL MOUNTED VENTS, LIGHT FIXTURES, F.E.C.
AND OTHER FIXTURES / ACCESSORIES. MOUNT
DOORBELLS TO SIDING (NO BLOCKING
NECESSARY). WHERE FIXTURE IS LARGER,
EXTEND BLOCKING 3" BEYOND WIDTH / HEIGHT OF
FIXTURE.
PAINT (E) PLYWOOD SOFFIT
NEW SIDING PER
WALL ASSEMBLY
SCALE: 3"=1'-0"11 BUMPOUT SOFFIT DETAIL
NEW WEATHER
RESISTIVE BARRIER
2
1
/
2
"
1 x 7 1/4 PAINTED FIBER
CEMENT TRIM; WRAP
CORNERS.
1 1/2"
1/
2
"
PROVIDE (N) FIBER
CEMENT TRIM
SHEET METAL FLASING
EXTEND DOWN HEAD
TRIM 3/4" MIN,
WITH DRIP EDGE
Approved
04/30/2024
EXTERIOR
DETAILS
A7.02
SCALE: AS NOTED
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
A7.0
2
8
SCALE: 3"=1'-0"1 INSIDE CORNER SHINGLE/PLANK DETAIL
EXISTING EXTERIOR
BUILDING MATERIALS
AND FINISHES TO BE
REMOVED TO EXPOSE
BARE PLYWOOD
SHEATHING. REPAIR OR
REPLACE AS REQUIRED
TO RECEIVE NEW WRB
AND SIDING. EXISTING
WALL FRAMING AND
INSULATION TO REMAIN.
NEW WEATHER
RESISTIVE BARRIER
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR
TYPE)
SHEET METAL 90°
INTERNAL
" W " MOULD
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR
TYPE)
SCALE: 3"=1'-0"2 OUTSIDE CORNER PLANK DETAIL
HARDIE PLANK LAP SIDING
LEAVE APPROPIATE
GAP AND CAULK
HARDIE TRIM BOARDS
PAINTED TO MATCH
ADJACENT TRIMLEAVE APPROPIATE
GAP AND CAULK
NEW WEATHER
RISISTIVE BARRIER
HARDIE PLANK LAP SIDING
EXTERIOR SHEATING
EXISTING EXTERIOR
BUILDING MATERIALS
AND FINISHES TO BE
REMOVED TO EXPOSE
BARE PLYWOOD
SHEATHING. REPAIR OR
REPLACE AS REQUIRED
TO RECEIVE NEW WRB
AND SIDING. EXISTING
WALL FRAMING AND
INSULATION TO REMAIN.
3
1
/
2
"
3 1/2"
SCALE: 3"=1'-0"3 OUTSIDE CORNER SHINGLE DETAIL
NEW WEATHER
RISISTIVE BARRIER
HARDIE SHINGLE LAP SIDING
EXTERIOR SHEATING
HARDIE SHINGLE SIDING
EXISTING EXTERIOR
BUILDING MATERIALS
AND FINISHES TO BE
REMOVED TO EXPOSE
BARE PLYWOOD
SHEATHING. REPAIR OR
REPLACE AS REQUIRED
TO RECEIVE NEW WRB
AND SIDING. EXISTING
WALL FRAMING AND
INSULATION TO REMAIN.
LEAVE APPROPIATE
GAP AND CAULK
HARDIE TRIM BOARDS
PAINTED TO MATCH
ADJACENT TRIMLEAVE APPROPIATE
GAP AND CAULK
3
1
/
2
"
3 1/2"
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR TYPE)
SCALE: 3"=1'-0"
TYP. WINDOW HEAD
BACKER ROD
& SEALANT
4
PAINTED FIBER
CEMENT TRIM
SEE 1/7.01, 2/7.01 FOR
WALL CONSTRUCTION
EXISTING WINDOW
AND INTERIOR TRIM
TO REMAIN
BACKER ROD
& SEALANT
SCALE: 3"=1'-0"
TYP. WINDOW JAMB
EXISTING WINDOW
AND INTERIOR TRIM
TO REMAIN
5
PAINTED FIBER
CEMENT TRIM
SEE 1/7.01, 2/7.01 FOR
WALL CONSTRUCTION
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR TYPE)
SCALE: 3"=1'-0"
TYP. DOOR HEAD
PAINTED FIBER
CEMENT TRIM
JAMES HARDIE
TRIM OR NEW SIDING (SEE
EXTERIOR ELEVATIONS)
6
SEE 1/7.01, 2/7.01 FOR
WALL CONSTRUCTION
EXISTING DOOR
AND INTERIOR
TRIM TO REMAIN
PAINTED FIBER
CEMENT TRIM
SCALE: 3"=1'-0"
TYP. DOOR JAMB7
NEW SIDING
(RE:EXTERIOR
ELEVATION FOR
TYPE)
EXISTING DOOR
AND INTERIOR
TRIM TO REMAIN
SEE 1/7.01, 2/7.01 FOR
WALL CONSTRUCTION
8 OUTLOOKER ROT REPAIR AND FLASHING
INCLUDE SHEET METAL FLASHING
END CAP AT GABLE ENDS.
SCALE: 3"=1'-0"
REPAIR WOOD ROT ON BEAM AND
BLOCKING WITH SYSTEMTHREE
ENDROT KIT WITH Sculpwood Max
Putty FOR STRUCTURAL REPAIR.
ATTACHMENT CLEAT AT
UNDER TOP CAP
VERTICAL WRAP
FLASHING ON BEAM
HORIZONTAL FLASHING
WITH CLEAT
Approved
04/30/2024
PAINT SCHEME
PERSPECTIVES
A8.01
ANACORTES
C 2014
REV ISSUED FOR DATE
PROJECT No: 202301.01
DRAWN BY:
CHECKED BY:
DATE ISSUED:04.29.2024
209 Prospect Street
Bellingham, WA 98225
360.734.4744
PERMIT SET
ARCHITECTURE | INTERIOR DESIGN
zervasgroup.com
SITE ONE
RE-CLADDING
BUILDING - 1 PERSPECTIVE
N.T.S.1 BUILDING - 2 PERSPECTIVE
N.T.S.4
BUILDING - 2 PERSPECTIVE
N.T.S.5BUILDING - 1 PERSPECTIVE
N.T.S.2
BUILDING - 1 PERSPECTIVE
N.T.S.3 BUILDING - 2 PERSPECTIVE
N.T.S.6
NOTE:
REFER TO ALL OTHER SHEETS
FOR DETAILS AND MATERIAL
LOCATION. THESE RENDERINGS
ARE SHOWN FOR GENERAL
DESING REFERENCE AND
PAINTING SCHEME ONLY.
Approved