Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2024-0515 3801 W6th Street
For inspections, please call (360) 293-1901 PARCEL: P107120 LEGAL DESCRIPTION: APPLICANT: Freedom Forever 15943 NE Cameron Blvd Portland, OR 97230 9718087776 OWNER: GRAHAM MARGARET ELLEN UNKNOWN ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 14000.00 $14,000.00 $14,000.00Total: FEES:Paid Due Plan Review Fee $154.21 $0.00 State Building Code Council fee $6.50 $0.00 Building Permit Fee $237.25 $0.00 $0.00Totals : REQUIRED INSPECTIONS Solar Final $397.96 BLD-2024-0515 SOLAR PERMIT ISSUED: EXPIRES: 07/29/2024 01/29/2026 PROJECT NAME: MARGARET GRAHAM - SOLAR SITE ADDRESS: 3801 W 6TH ST ANACORTES * If you answered yes to all of the above questions, your PV installation is eligible for a building permit. CONDITIONS Page 1 of 1Printed by : Cheri Gleichmann on: 10/14/2024 03:44 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ REV #1 MARGARET GRAHAM 3801 W 6TH ST All corresponding changes are notated on the plans by revision clouds. Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or concerns. Construction Engineering Freedom Forever Planset Revision Letter Attn. City of Anacortes (WA): 8/8/2024 The changes outlined in Revision Details have been applied to the plans corresponding to the following customer: Revision Details: REV 1: Layout was adjusted per updated contract. Changes are reflected on PV2, PV2A, PV3, PV4, PV7A Freedom Forever engineering@freedomforever.com THIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE AS ADOPTED BY CITY OF ANACORTES CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: ROOF MOUNT PHOTOVOLTAIC SYSTEM PV-1 PROJECT DETAILS PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B ARRAY DETAILS PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. CRITTER GUARD TO BE INSTALLED PV-1 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 GREG ALBRIGHT SITE LOCATION PROJECT DETAILS THIS SYSTEM DESIGNED WITH: WIND SPEED: 98 WIND EXPOSURE: B SNOW LOAD: 17 108'-5" 98'-3"15'-5" 45'-9" 43'-10" 3'-10" INV JB UM AC MSP SITE PLAN SCALE: 2/25" = 1'-0"1 PV-2 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 ROOF AREA: 3313 SQ FT SITE PLAN LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT UTILITY METER JUNCTION BOX INVERTER MAIN SERVICE PANEL AC UM JB INV MSP GREG ALBRIGHT TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 3313 SQ FT SINGLE MODULE AREA: 21.88450368 SQ FT TOTAL NUMBER OF MODULES: 23 TOTAL AREA OF MODULES: 503.34 SQ FT ROOF COVERAGE: 15.19% FIRE SPRINKLERS : NO PV SYSTEM 9.085 kW-DC 7.600 kW-AC W 6TH ST DRIVEWAY 1 3' 3' 3' 3'3' 3' INV JB UM AC MSP 3' PV-2A FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 ROOF PLAN SCALE: 1/8" = 1'-0"1 NOTES: 1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3.JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 3313 SQ FT ROOF PLAN WITH MODULES LAYOUT LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT UTILITY METER JUNCTION BOX INVERTER MAIN SERVICE PANEL AC UM JB INV MSP TOTAL ROOF AREA: 3313 SQ FT TOTAL ARRAY AREA: 503.34 SQ FT ARRAY COVERAGE: 15.19% SYSTEM DISTRIBUTED WEIGHT: 2.36 LBS ROCKIT SMART SLIDE POINT-LOAD: 32.08 LBS GREG ALBRIGHT FIRE ACCESS PATHWAYS FIRE ACCESS PATHWAYS 1 PV-2B FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 ARRAY DETAILS ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA ROOF 1 14 35 35 247 647 SQ FT 306.38 SQ FT ROOF 2 6 35 35 247 273 SQ FT 131.31 SQ FT ROOF 3 3 35 35 157 440 SQ FT 65.65 SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT ROOF DETAILS: TOTAL ROOF AREA: 3313 SQ FT TOTAL ARRAY AREA: 503.34 SQFT ARRAY COVERAGE: 15.19% SYSTEM DISTRIBUTED WEIGHT: 2.36 LBS ROCKIT SMART SLIDE POINT-LOAD: 32.08 LBS GREG ALBRIGHT 1 ROCKIT MOUNT ROOF SURFACE SKIRT ROCKIT MOUNT ROOF MEMBRANE PV MODULE ROCKIT MOUNT ROOF MEMBRANE 2" MIN. EMBED. 2" MIN. EMBED. 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2" MIN. EM B E D . PV MODULE PV MODULE 3" M I N . (E)RAFTER/TOP-CHORD 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 6 " M A X . ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PV-3 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 MOUNTING DETAILS STAGGERED DETAIL For Illustration purposes only STACKED DETAIL For Illustration purposes only GREG ALBRIGHT 1 4 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #10 AWG MUST BE IN EMT CONDUIT STRING-2STRING-1 JUNCTION BOX SOLAREDGE S440 POWER OPTIMIZERS SOLAREDGE S440 POWER OPTIMIZERS 11 CANADIAN SOLAR: CS3N-395MS 12 CANADIAN SOLAR: CS3N-395MS 4 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT UM(E) 200A / 2P MAIN BREAKER (TOP FED) (E) 200A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) UTILITY METER X173426367 CL200 (N) 40A / 2P PV BREAKER TO OTHER LOADS TO UTILITY UNDERGROUND FEED (N) SOLAREDGE SE7600H-USRGM [SI1] INVERTER AC DC RAPID SHUTDOWN SWITCH (N) 60A RATED VISIBLE LOCKABLE LABELED DISCONNECT EATON DG222URB (OR EQUIVALENT) KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED 3 - #8 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT 3 - #8 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 32.00A @ 240V 32.00 X 1.25 =40.00AMPS 40A BREAKER - OK SEE 705.12 OF 2020 NEC 200 X 1.20 =240 240 -200 =40A ALLOWABLE BACKFEED PV-4 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 THREE LINE DIAGRAM GREG ALBRIGHT 1 PV-5 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO OPTIMIZER 2 10 40 14.30 1 1 40.00 17.88 2 DC OPTIMIZER TO JUNCTION BOX 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER 4 10 40 15.00 1 0.8 32.00 18.75 4 AC INVERTER TO AC DISCONNECT 3 8 55 32.00 1 1 55.00 40.00 5 AC AC DISCONNECT TO POI 3 8 55 32.00 1 1 55.00 40.00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST: PV-6 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 QTY.PART PART #DESCRIPTION 23 110 - MODULES PV-116-395 "MFG: CANADIAN, 395W MONO BOB, MFG SKU: CS3N-395MS" 1 120 - INVERTERS INV-120-768 "MFG: SOLAREDGE, 7.6 KW RGM SCREENLESS W/CONSUMPTION MONITORING, MFG SKU: SE7600H-US000BEI4" 1 180 - MONITORING EQUIPMENT ME-180-502 "MFG: SOLAREDGE, CELL MODEM W/5 YRS, MFG SKU: SE-CELL-B-R05-US-S-S2" 2 160 - EQUIPMENT ACCESSORIES EA-163-508 "MFG: SOLAREDGE, 225A CT, MFG SKU: SECT-SPL-225A-T-20" 1 160 - EQUIPMENT ACCESSORIES EA-163-304 "MFG: SOLAREDGE, ENERGY NET PLUG-IN, MFG SKU: ENET-HBNP-01" 23 130 - OPTIMIZERS OPT-130-440-2 "MFG: SOLAREDGE, 440W 60V OPTIMIZER, MFG SKU: S440" 2 260 - FITTINGS/ANCHORS RAC-261-527 "MFG: UNIRAC, JUNCTION BOX, COMP SHINGLE AND RAIL MOUNT APPLICATIONS, MFG SKU: SOLOBOX-D" 2 210 - RAILS RAC-211-201 "MFG: UNIRAC, E-BOSS J-BOX MOUNTING BRACKET, MFG SKU: 00802JB" 1 320 - DISCONNECTS EE-321-060 "MFG: EATON, DISCONNECT, GENERAL DUTY, 2P, 240V, 60A, NON FUSIBLE, NEMA 3R, MFG SKU: DG222URB" 230 260 - FITTINGS/ANCHORS RAC-260-550 "MFG: BURNDY, PV WILEY CABLE CLIP THICKNESS RANGE: 1.3 TO 3MM MFG SKU: ACC-FPV180" 3 350 - ELECTRICAL ACCESSORIES EA-350-585 "MFG: ILSCO, GROUND LUG, MFG SKU: SGB-4" 37 260 - FITTINGS/ANCHORS RAC-265-034 "MFG: ECO FASTEN, ROCKIT SMART SLIDE BLK 6 - 75"", MFG SKU: 2011024" 23 260 - FITTINGS/ANCHORS RAC-265-004 "MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021" 11.5 260 - FITTINGS/ANCHORS RAC-265-028 "MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012" 1 260 - FITTINGS/ANCHORS RAC-265-031 "MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035" 23 260 - FITTINGS/ANCHORS RAC-265-018 "MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012" 1 260 - FITTINGS/ANCHORS RAC-260-049 "MFG: EZ SOLAR, JUNCTION BOX, PV, MFG SKU: JB-1.2" 148 260 - FITTINGS/ANCHORS RAC-265-035 "MFG: ECO FASTEN, ROCKIT SCREW #12X3"" W/BW, MFG SKU: 2011025" 2 350 - ELECTRICAL ACCESSORIES EA-350-585 "MFG: ILSCO, GROUND LUG, MFG SKU: SGB-4" 37 260 - FITTINGS/ANCHORS RAC-265-003 "MFG: ECO FASTEN, ROCKIT MOUNT AL BLK, MFG SKU: 2011020" OCPD SIZES: 40A BREAKER SERVICE LIST: NONE EQUIPMENT & SERVICE LIST GREG ALBRIGHT NOTES: M 690.54 705.12(B)(2)(3)(b) "WARNING" DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 32.00 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS WARNING: POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY 690.56(C)(1)(A) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC 690.15, 690.54 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 32.00 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3) INVERTER ARRAY J/BDC "WARNING" PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT AND ENCLOSURES "WARNING" ELECTRICAL SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 690.13 (B) 690.53 PV SYSTEM DC DISCONNECT MAXIMUM VOLTAGE: 480V MAXIMUM CIRCUIT CURRENT: 20A MAX RATED OUTPUT CURRENT OF THE CONTROLLER OR DC-TO-DC CONVERTER: 15A NEC 690.31(G)(3) & (4) PMPV METER SOLAR ELECTRICPV PANELS MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX DC-DC CONVERTER OUTPUT CURRENT V A A 20 480 15 PV-7 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 LABELS GREG ALBRIGHT 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS CAUTION: PV-7A FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN 23 PV MODULES W 6TH ST UTILITY METER MAIN SERVICE PANEL AC DISCONNECT INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX 1 108'-5"3'-10" INV JB UM AC MSP PV-8 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 SOLAREDGE OPTIMIZER CHART OPTIMIZER CHART GREG ALBRIGHT 1 1-10 11-20 21-30 31-40 41-50 51-60 2 3 4 5 6 7 8 9 10 108'-5" 43'-10" 3'-10" INV JB UM AC MSP PV-9 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 SAFETY PLAN GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET INCIDENT REPORTING: INJURIES - CALL INJURY HOTLINE (855) 400-7233 *If injury is life threatening, call 911 first THEN the Injury Hotline NON-INJURIES - USE MOBILE INCIDENT REPORTING (Auto, Property Damage, Near Miss) NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: NAME: _______________________________________________ ADDRESS: ___________________________________________ NEAREST HOSPITAL: NAME:_______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION: NAME: _______________________________________________ PHONE NUMBER: _____________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O BREAK AND WATER LOG THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS POLICIES INSTRUCTIONS: 1.SCAN QR LINK BELOW TO ACCESS ALL FREEDOM FOREVER SAFETY POLICIES AND PROGRAMS. W 6TH ST JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access ·Ladders must be inspected before each use. ·Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. ·Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. ·A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). ·Additional notes: Mobile Equipment ·Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. ·Type(s) of mobile equipment (Type/Make/Model): ·Qualified operator(s): Material Handling and Storage ·Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection ·A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. ·First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. ·FPCP (name and title): ·FPU and LPD (name and title): Electrical Safety ·The Electrical Qualified Person (EQP) is required onsite to perform electrical work. ·All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. ·Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. ·EQP (name and tile): Public Protection ·The safety of the Client and Public must be maintained at all times. ·The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. ·Company, Client and Public property shall be protected from falling objects. ·Pets (including dogs) shall be secured by their owners prior to work start. ·The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. ·Crew leader responsible for communication with the client: ·Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing ·All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. ·Crew leader (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): Airborne Contaminants: ·Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) ·Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. ·If yes, list specific tasks and protection in place: Weather and Environment ·The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) ·The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. ·Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. ·Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention ·Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. ·Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. ·New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. ·Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. ·Cool Vests are encouraged for all employees at all times during periods of high heat. ·Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? ·If offsite replenish is necessary, where will you go to replenish water (location/address): ·Who will replenish the drinking water (name): Restroom facilities ·Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. ·Restroom facilities will be (circle one): Onsite - Offsite ·If Offsite, add location name and address: Incident Reporting Procedure ·Contact your Site Supervisor Name: Phone: ·Contact your Manager Name: Phone: ·Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREEDOM F O R E V E R I N D Y 8.00 TEMPLAT E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 464284 DESIGNED BY: T.S. CLIENT: MARGARET GRAHAM 3801 W 6TH ST, ANACORTES, WA 98221 AHJ: CITY OF ANACORTES UTILITY: PUGET SOUND ENERGY METER: X173426367 APN: P107120 EMAIL: CYCLINGCYCLOPS@GMAIL.COM FINANCE: CASH SYSTEM: SYSTEM SIZE (DC): 23 X 395 = 9.085 kW SYSTEM SIZE (AC): 7.600 kW @ 240V MODULES: 23 X CANADIAN SOLAR: CS3N-395MS OPTIMIZERS: 23 X SOLAREDGE S440 INVERTER: SOLAREDGE SE7600H-USRGM [SI1] DATE: 8/8/2024 T.S.8/8/2024 -- -- 1 - - 1 SAFETY PLAN GREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINK PV INSTALLATION REFERENCESFREEDOM REFERENCES BATTERY INSTALLATION REFERENCES ENPHASE SOLAREDGE TESLAINSTALL HOTLINE TESLA Storage Systems NON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage Systems Misc. Quick Guide FOR INSTALLATION REFERENCE ONLY V1.4 CS3N-380|385|390|395|400|405MS 380 W ~ 405 W MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 405 W 19.9 %405 W Better shading tolerance Minimizes micro-crack impacts MORE POWER Lower LCOE & BOS cost 25Years Years Linear Power Performance Warranty* Industry Leading Product Warranty on Materials and Workmanship* HiKuBlack Mono PERC Heavy snow load up to 8100 Pa, 6000 Pa* MANAGEMENT SYSTEM CERTIFICATES* 1st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% F23 FrameBLACK FRAME ON BLACK BACKSHEET PRODUCT CERTIFICATES* IEC 61215 / IEC 61730 / CE C M Y CM MY CY CMY K CS-HiKuBlack_CS3N-MS_v2.9C25_F23_J2_NA_PRINT.pdf 1 1/10/2022 4:25:38 PM PARTNER SECTION ENGINEERING DRAWING (mm)CS3N-400MS / I-V CURVES 0 ~ + 10 W Rear View Mounting Hole 9 14 R Frame Cross Section A - A 35 35 V A 11 10 9 7 6 5 4 3 1 0 V A 1000 W/m 600 W/m 400 W/m 5°C 45°C 65°C 11 10 9 7 6 5 4 3 1 0 TEMPERATURE CHARACTERISTICS Data MECHANICAL DATA Data Cell Type Mono-crystalline Dimensions Weight Front Cover Frame 1650 mm (65.0 in) (-) /1000 mm (39.4 in) (+)* Connector T4 or MC4 series Per Pallet 30 pieces * For detailed information, please contact your local Canadian Solar sales and ELECTRICAL DATA | STC* CS3N 380MS 385MS 390MS 395MS 400MS 405MS 390 W 395 W 400 W 405 W Operating Temperature Module Fire Performance Power Tolerance ELECTRICAL DATA | NMOT* CS3N 380MS 385MS 390MS 395MS 400MS 405MS 303 W 11 5 5 13 0 0 35 19 4 0 6-5GroundingHole MountingHoleMountingHole 50 Feb. 2022 | All rights reserved | PV Module Product Datasheet v2.9C25_F23_J4_NACSI SOLAR (USA) CO., LTD. C M Y CM MY CY CMY K CS-HiKuBlack_CS3N-MS_v2.9C25_F23_J2_NA_PRINT.pdf 2 1/10/2022 4:25:39 PM solaredge.com SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014-2023 per articles 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Small, lightweight, and easy to install both outdoors or indoors Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) 12-25 YEAR WARRANTY SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT Rated AC Power Output 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA ACOutput Voltage Min.-Nom.-Max. (211 - 240 - 264) Vac ACOutputVoltage Min.-Nom.-Max. (183 - 208 - 229) ---Vac ACFrequency (Nominal)59.3 - 60 - 60.5 (1)Hz Maximum Continuous Output Current @240V 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V 16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country ConfigurableThresholds Yes INPUT Maximum DC Power @240V 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 Vdc Maximum Input Current @240V(2)10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1)For other regional settings please contact SolarEdge support. (2)A higher current source may be used; the inverter will limit its input current to the values stated. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.All other trademarks mentioned herein are trademarks of their respective owners. Date: June 19, 2023 DS-000153-NAM. Subject to change without notice. SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), wireless SolarEdge Home Network (optional)(3),Wi-Fi (optional), Cellular (optional) Revenue Grade Metering,ANSI C12.20 Optional(4) Consumption Metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown -NEC 2014-2023 per articles 690.11 and 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14 (HI), CSA C22.3 No. 9 Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14 6 AWG 1'' Maximum / 14 4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1 2 strings / 14 6 AWG 1'' Maximum / 1 3 strings / 14 6 AWG Dimensions with Safety Switch (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(5) in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 44.9 / 20.4(5)lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(6) Protection Rating NEMA 4X (Inverter with Safety Switch) (3)For more information, refer to the SolarEdge Home Network datasheet(4)Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BEI4. For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box. (5) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (6)-rating information refer to the Temperature De-rating Technical Note for North America. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills. Product specifications Eaton DG222URB Catalog Number: DG222URB Eaton General duty non-fusible safety switch, single-throw, 60 A, NEMA 3R, Rainproof, Painted galvanized steel, Two-pole, Two-wire, 240 V General specifications Eaton general duty non-fusible safety switch DG222URB 782113144238 7.38 in 14.38 in 8.69 in 9 lb Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. UL Listed WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Product Name Catalog Number UPC Product Length/Depth Product Height Product Width Product Weight Warranty Certifications Catalog Notes Eaton Corporation plc Eaton House 30 Pembroke Road Dublin 4, Ireland Eaton.com © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are property of their respective owners.Eaton.com/socialmedia Product specifications General duty safety switch Painted galvanized steel Non-fusible, single-throw Non-fusible 2 NEMA 3R 240V 60A Two-pole Resources Eaton's Volume 2—Commercial Distribution Double Up on Safety Switching Devices Flex Center Eaton Specification Sheet - DG222URB Selling Policy 25-000 - Distribution and Control Products and Services Product Category Enclosure material Type Fuse configuration Number of wires Enclosure Voltage rating Amperage Rating Number Of Poles Catalogs Multimedia Specifications and datasheets Warranty guides ; 5,60$576/,'(%/. 52&.,7)/$6+/(666/,'($66(0%/< $'+(6,9(5(/($6(/,1(5 ,7(012'(6&5,37,21 52&.,760$576/,'($66(0%/< 3$57180%(5 '(6&5,37,21 5,60$576/,'(%/. 0$7(5,$/$/80,180(3'0$'+(6,9(75($7('3$3(5 ),1,6+%/$&.5HY&6 1 .31 7.8 2.87 72.8 3.00 76.2 .55 14.0 .42 10.5 RI SMART SCREW #12X3" W/BW PART NUMBER DESCRIPTION 2011025 RI SMART SCREW #12X3" W/BW ITEM NO.DESCRIPTION 1 SELF TAPPING SCREW #12 WITH SEALING WASHER ASSEMBLY MATERIAL STAINLESS STEEL, EPDM RUBBER FINISH MILL, BLACK Rev: CS-2 5Ζ&2036/Ζ'($/%/. 52&.,796/,'(&203 0DWHULDO $OXPLQXP )LQLVK %ODFN ,7(012'(6&5,37,21 52&.,796/,'(&203 /$*6&5(:7+5($'(3'0%$&.(':$6+(5 3$57180%(5 '(6&5,37,21 5,&2036/,'($/%/. REV.- CS1 5Ζ&2036/Ζ'($/%/. /$*6&5(:7+5($'(3'0%$&.(':$6+(5 7+' +HDG 0DWHULDO 6WDLQOHVV6WHHO )LQLVK 0LOO REV.- CS1 *))/$6+Ζ1**/9%/.; *)0*$/%/.:2:$6+(5$66(0%/< ,7(012'(6&5,37,21 *)0*$/%/.:2:$6+(5$66(0%/< 3$57180%(5 '(6&5,37,21 *))/$6+,1**/9%/.; REV.- CS1 7+58 0DWHULDO &RUURVLRQ5HVLVWDQW6WHHO )LQLVK %ODFN 01 March 27th, 2024 EcoFasten 4141 West Van Buren St. Phoenix, AZ 85009 Attn.: EcoFasten Solar Engineering Department Re: Report # 7.16-RockIt_ CS-SS EcoFasten RockIt System, with Comp Slide or Smart Slide, Certification for Gable and Hip roofs. This letter certifies the loading criteria and design basis used for the structural analysis of the EcoFasten - RockIt System as shown in Report # 7.16-RockIt_CS-SS "Engineering Certification for the EcoFasten - RockIt System with Comp or Smart Slide for Gable and Hip Roofs". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications. The Span Tables provided in the referenced report may be used when all assumptions listed therein are met. Building Codes: 1. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2021 Washington State Building Code, Based on 2021 International Building Code 3. 2021 Washington State Residential Code, Based on 2021 International Residential Code 4. SEAOC (Structural Engineer Association of California) report PV2-2017 Wind Design for Solar Arrays 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 6. Aluminum Design Manual 2020, by The Aluminum Association, Inc. 7. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council Please note our evaluation only applies to EcoFasten products and excludes the structural adequacy of the chosen roof attachments, PV modules, or underlying roof supporting members. It shall be the responsibility of the installer or system designer to verify the structural capacity and adequacy of the referenced system components with respect to the applied or resultant loads of the chosen array configuration. Sincerely, Matthew S Kuzila, P.E. Sealed 03.27.2024 6:.(8+ =7 ,7 /$ $0 3 5 5 2 ( )( (1,66 *,12(1 $/ 5 '(*(,56(7 6:.(8+ =7 ,7 /$ $0 3 5 5 2 ( )( (1,66 *,12(1 $/ 5 '(*(,56(7