HomeMy WebLinkAboutPermit File BLD-2024-0502 1301 6th StreetFIXTURES Qty Mechanical Fixtures 1 Range Hood 1 Refrigeration Unit 1 Stove/Range/Oven Qty Plumbing Fixtures PARCEL: P55636 LEGAL DESCRIPTION: APPLICANT: KREIDER, GAVEN 1010 22nd Street Anacortes, WA 98221 360-540-4806 OWNER: TOMAS STEVE P & TOMAS SHEILA 1301 6TH STREET ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 75000.00 $75,000.00 $75,000.00Total: FEES:Paid Due Building Permit Fee $818.75 $0.00 Mechanical and plumbing remodel fixtures fees $60.95 $0.00 State Building Code Council fee $6.50 $0.00 Plan Application Fee $200.00 $0.00 Plan Review Fee $532.19 $0.00 $0.00Totals : REQUIRED INSPECTIONS Fenestration U-Factors Framing CONTACT:Steve T. 1301 6th Street Anacortes, WA 98221 3607084105 CONSTRUCTION CONTRACTOR:KREIDER CONSTRUCTION INC 1010 22ND ST ANACORTES, WA 98221 360.707.5588 License: KREIDCI024PE Expires: 10/30/2025 $1,618.39 BLD-2024-0502 RESIDENTIAL INTERIOR ONLY REMODEL ISSUED: EXPIRES: 07/31/2024 01/31/2026 PROJECT NAME: TOMAS RESIDENCE SITE ADDRESS: 1301 6TH ST ANACORTES Page 1 of 2Printed by : Cheri Gleichmann on: 10/14/2024 02:31 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ For inspections, please call (360) 293-1901 Gas Piping Mechanical Rough-In Plumbing Rough-In Drywall or Lath Insulation Building Final Page 2 of 2Printed by : Cheri Gleichmann on: 10/14/2024 02:31 PM City of Anacortes, WA RESIDENTIAL INTERIOR ONLY REMODEL BLD-2024-0502 Kreider Design Studio 1010 22nd Street Anacores, WA 98221 tel. 360-540-4806 kreider.gaven@gmail.com kreiderdesignstudio.com KDS TO M A S R E S I D E N C E 13 0 1 6 t h S t . An a c o r t e s , W A 9 8 2 2 1 PE R M I T S E T SHEET TITLE: ISSUE DATE: 7.16.2024 TITLE SHEET A0 TOMAS RESIDENCE 1301 6TH ST ANACORTES, WA 98221 Parcel # P55636 N ABBREVIATIONS: ABV. CONC. EXT. INT. w/ Above Concrete Exterior Interior With PROJECT DESCRIPTION: Interior only remodel of existing kitchen and bath. PROPERTY LOCATION LOCATION MAP: DRAWING INDEX: A0 A2.1 A2.2 A2.3 A6.1 A6.2 COVER SHEET (E) FLOOR PLAN DEMO PLAN (N) FLOOR PLAN INTERIOR ELEVATIONS INTERIOR ELEVATIONS o/ SGD STRUCT. SSD. Over Sliding Glass Door Structural See Structural Drawings A0.0 0 Exterior Elev. Building Sec. Elevation Direction 1 Revision CloudRevision Number Revision Area SYMBOLS: Owner:Steve & Sheila Tomas 1301 6th St Anacortes, WA 98221 Designer:Gaven Kreider Kreider Design Studio 1010 22nd Street Anacortes, WA 98221 Tel. (360) 540-4806 DIRECTORY: Contractor:Greg Kreider Kreider Construction 1010 22nd Street Anacortes, WA 98221 Tel. (360) 421-1901 DESIGN CRITERIA: Project Data:Zoning: Old Town Lot Size: 6,098 SF (0.14 acres) Lot Coverage: No change Building Areas: No change Jurisdiction:City of Anacortes Building Code:2021 IRC Energy Code:2021 WSEC-R Energy Efficiency:See attached 2021 WSEC-R 2nd Edition Remodel / Alterations Worksheet. GENERAL NOTES: - All dimensions to face of framing. - GC to verify all dimensions in field. CITY OF ANACORTES PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT #:______________________________ ADDRESS:____ _______________ APPROVED BY: ______________ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. BLD-2024-0502 1301 6th St (E) KITCHEN TO BE REMODELED (E) BATH TO BE REMODELED (E) RESIDENCE NO WORK TO BE DONE (E) RESIDENCE NO WORK TO BE DONE Kreider Design Studio 1010 22nd Street Anacores, WA 98221 tel. 360-540-4806 kreider.gaven@gmail.com kreiderdesignstudio.com KDS TO M A S R E S I D E N C E 13 0 1 6 t h S t . An a c o r t e s , W A 9 8 2 2 1 PE R M I T S E T SHEET TITLE: ISSUE DATE: 7.16.2024 (E) FLOOR PLAN A2.1 1 1/4" = 1'-0" (E) FLOOR PLAN NORTH (E) KITCHEN (E) BATH 4'-0" 4'-0" replace (e) windows with (n) windows per owner demo all (e) cabinetry, typ. (E) RESIDENCE NO WORK TO BE DONE (E) RESIDENCE NO WORK TO BE DONE Kreider Design Studio 1010 22nd Street Anacores, WA 98221 tel. 360-540-4806 kreider.gaven@gmail.com kreiderdesignstudio.com KDS TO M A S R E S I D E N C E 13 0 1 6 t h S t . An a c o r t e s , W A 9 8 2 2 1 PE R M I T S E T SHEET TITLE: ISSUE DATE: 7.16.2024 DEMO PLAN A2.2 1 1/4" = 1'-0" DEMO PLAN NORTH (N) BATH breakfast bar w/ rolling cart below pantry (N) KITCHEN 36" ref. dw combo wall oven / m.w. 2 3 1 1 A6.14 2 3 1 1A6.24 (n) windows per owner, max. u-value = 0.30 counter 2'-1" 2'-8" new wood flooring new tile flooring corner sink per owner 18" counter 18 " c o u n t e r 50 hood at range, vent to outside100 min. UP H.R. @ 34" (e) stair to remain 12" shelves (E) RESIDENCE NO WORK TO BE DONE (E) RESIDENCE NO WORK TO BE DONE Kreider Design Studio 1010 22nd Street Anacores, WA 98221 tel. 360-540-4806 kreider.gaven@gmail.com kreiderdesignstudio.com KDS TO M A S R E S I D E N C E 13 0 1 6 t h S t . An a c o r t e s , W A 9 8 2 2 1 PE R M I T S E T SHEET TITLE: ISSUE DATE: 7.16.2024 (N) FLOOR PLAN A2.3 1 1/4" = 1'-0" (N) FLOOR PLAN NORTH 36" oven 24" DW breakfast bar w/ rolling cart microwave 36" REF/ FRZ pa i n t e d ca b i n e t pa i n t e d w d . pa n e l op e n w o o d sh e l v e s re p l a c e . wi n d o w s pe r o w n e r (e ) d o o r +9'-0" +3'-0" +9'-0" ro o m be y o n d (n ) p a n t r y do o r ma t c h e x i s t . ba s e b o a r d st o n e ba c k s p l a s h fa u c e t p e r ow n e r +9'-0" +3'-0" ro o m be y o n d (e ) b r i c k , fi n i s h p e r ow n e r pa i n t e d fr i d g e pa n e l pa i n t e d ca b i n e t +5'-0"+5'-0" 6" s t o n e ba c k s p l a s h gw b gw b gw b gw b gw b wall oven (e) stair 1 2 3 4 pa i n t e d ra n g e h o o d co v e r PT-01 PT-01 PT-01 PT-01 ST-01 ST-01 ST-01 Kreider Design Studio 1010 22nd Street Anacores, WA 98221 tel. 360-540-4806 kreider.gaven@gmail.com kreiderdesignstudio.com KDS TO M A S R E S I D E N C E 13 0 1 6 t h S t . An a c o r t e s , W A 9 8 2 2 1 PE R M I T S E T SHEET TITLE: ISSUE DATE: 7.16.2024 INTERIOR ELEVATIONS A6.1 1 3/8" = 1'-0" KITCHEN ELEVATION +3'-0" gla s s sh o w e r do o r gl a s s sh o w e r (e ) w i n d o w (e ) d o o r (e ) d o o r si n k p e r ow n e r si n k p e r ow n e r +3'-0"+3'-0" ti l e ti l e ti l e h a l f wa l l +7'-0" +7'-0" gw b gw b ti l e ti l e 1 2 3 4 PT-02 PT-02 PT-02 T-02 T-02 PT-02 T-02 gw b gw b Kreider Design Studio 1010 22nd Street Anacores, WA 98221 tel. 360-540-4806 kreider.gaven@gmail.com kreiderdesignstudio.com KDS TO M A S R E S I D E N C E 13 0 1 6 t h S t . An a c o r t e s , W A 9 8 2 2 1 PE R M I T S E T SHEET TITLE: ISSUE DATE: 7.16.2024 INTERIOR ELEVATIONS A6.2 1 3/8" = 1'-0" BATH ELEVATION Are the windows and/or doors being replaced? If yes, New windows and doors (+frames) must have an area weighted average U-factor of ≤0.30 Will the heating or cooling system be replaced? If yes, New equipment must meet current requirements and the ducts need to be tested Will the hot water system be altered? If yes, New water heating equipment must meet current code requirements Are more than 10% of the light fixtures being changed? If yes, 100% of all lamps must be high efficacy 2021 WSEC-R 2nd Edition Remodel / Alteration Worksheet Will you be exposing the walls? If yes, 2 X 4 wall studs require R-15 insulation 2 X 6 wall studs require R-21 insulation If siding is replaced C.I. equal to R-5 may need installed under the siding. Will the roof/ceiling framing cavities or attic be exposed? If yes, Exposed roof or ceiling assemblies must be insulated - Vaulted ceilings, Insulate to the full depth of the framing member Flat ceilings, install R-60 insulation or what the attic space can accommodate based on the roof pitch Will the will the floor framing cavities be exposed? If yes, Exposed floor cavities must be insulated to R-30 Yes Yes Yes Yes Yes Yes Yes No No No No No No No R503.1.1.1 Replacement fenestration. Where some or all of an existing fenestration unit is replaced with a new fenestration product, including sash and glazing, the replacement fenestration unit shall meet the applicable requirements for U-factor and SHGC in Table R402.1.3. Where more than one replacement fenestration unit is being installed, an area-weighted average of the U-factor and SHGC of all replacement fenestration shall be permitted to be used to demonstrate compliance. R503.1.1 Building envelope. Building envelope assemblies that are part of the alteration shall comply with Section R402.1.3 or R402.1.5, Sections R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.3.5 and R402.4.2. Exception: The following alterations need not comply with the requirements for new construction provided the energy use of the building is not increased: 1.Storm windows installed over existing fenestration. 2.Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a minimum of R-21. 3.Construction where the existing roof, wall or floor cavity is not exposed. 4.Roof recover. 5.Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. 6.Surface-applied window film installed on existing single pane fenestration assemblies to reduce solar heat gain provided the code does not require the glazing fenestration to be replaced. R503.2 Change in space conditioning. Any non-conditioned or low-energy space that is altered to become conditioned space shall be required to be brought into full compliance with this (WSEC-R) code. R502.1.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the addition shall comply with Section R403. Exception: The following need not comply with the testing requirements of Section R403.3.3: 1.Additions of less than 750 square feet. 2.Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in WSU RS-33. 3.Ducts with less than 40 linear feet in unconditioned spaces. 4.Existing duct systems constructed, insulated or sealed with asbestos. R503.1.4 Lighting. New lighting systems that are part of the alteration shall comply with Section R404.1. Exception: Alterations that replace less than 10 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. R503.1.3 Service hot water systems. New service hot water systems that are part of the alteration shall comply with Section R403.5. R503.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the alteration shall comply with Section R403. Exceptions: 1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear feet in unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2 2. Existing duct systems constructed, insulated or sealed with asbestos.