HomeMy WebLinkAboutPermit File BLD-2024-0502 1301 6th StreetFIXTURES
Qty Mechanical Fixtures
1 Range Hood
1 Refrigeration Unit
1 Stove/Range/Oven
Qty Plumbing Fixtures
PARCEL: P55636
LEGAL DESCRIPTION:
APPLICANT: KREIDER, GAVEN
1010 22nd Street
Anacortes, WA 98221
360-540-4806
OWNER: TOMAS STEVE P & TOMAS SHEILA
1301 6TH STREET
ANACORTES, WA 98221
VALUATIONS:
Estimated construction cost 75000.00 $75,000.00
$75,000.00Total:
FEES:Paid Due
Building Permit Fee $818.75 $0.00
Mechanical and plumbing
remodel fixtures fees
$60.95 $0.00
State Building Code Council fee $6.50 $0.00
Plan Application Fee $200.00 $0.00
Plan Review Fee $532.19 $0.00
$0.00Totals :
REQUIRED INSPECTIONS
Fenestration U-Factors Framing
CONTACT:Steve T.
1301 6th Street
Anacortes, WA 98221
3607084105
CONSTRUCTION CONTRACTOR:KREIDER CONSTRUCTION INC
1010 22ND ST
ANACORTES, WA 98221
360.707.5588
License: KREIDCI024PE
Expires: 10/30/2025
$1,618.39
BLD-2024-0502 RESIDENTIAL INTERIOR ONLY
REMODEL
ISSUED:
EXPIRES:
07/31/2024
01/31/2026
PROJECT NAME: TOMAS RESIDENCE
SITE ADDRESS: 1301 6TH ST ANACORTES
Page 1 of 2Printed by : Cheri Gleichmann on: 10/14/2024 02:31 PM
City of Anacortes, WA
904 6th Street
Anacortes, WA 98221
(360) 293-1901
http://cityofanacortes.org/
For inspections, please call (360) 293-1901
Gas Piping
Mechanical Rough-In
Plumbing Rough-In
Drywall or Lath
Insulation
Building Final
Page 2 of 2Printed by : Cheri Gleichmann on: 10/14/2024 02:31 PM
City of Anacortes, WA
RESIDENTIAL INTERIOR ONLY REMODEL BLD-2024-0502
Kreider Design Studio
1010 22nd Street
Anacores, WA 98221
tel. 360-540-4806
kreider.gaven@gmail.com
kreiderdesignstudio.com
KDS
TO
M
A
S
R
E
S
I
D
E
N
C
E
13
0
1
6
t
h
S
t
.
An
a
c
o
r
t
e
s
,
W
A
9
8
2
2
1
PE
R
M
I
T
S
E
T
SHEET TITLE:
ISSUE DATE:
7.16.2024
TITLE SHEET
A0
TOMAS RESIDENCE
1301 6TH ST
ANACORTES, WA 98221
Parcel #
P55636
N
ABBREVIATIONS:
ABV.
CONC.
EXT.
INT.
w/
Above
Concrete
Exterior
Interior
With
PROJECT DESCRIPTION:
Interior only remodel of
existing kitchen and bath.
PROPERTY LOCATION
LOCATION MAP:
DRAWING INDEX:
A0
A2.1
A2.2
A2.3
A6.1
A6.2
COVER SHEET
(E) FLOOR PLAN
DEMO PLAN
(N) FLOOR PLAN
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
o/
SGD
STRUCT.
SSD.
Over
Sliding Glass Door
Structural
See Structural Drawings
A0.0
0 Exterior Elev.
Building Sec.
Elevation
Direction
1
Revision CloudRevision
Number
Revision Area
SYMBOLS:
Owner:Steve & Sheila Tomas
1301 6th St
Anacortes, WA 98221
Designer:Gaven Kreider
Kreider Design Studio
1010 22nd Street
Anacortes, WA 98221
Tel. (360) 540-4806
DIRECTORY:
Contractor:Greg Kreider
Kreider Construction
1010 22nd Street
Anacortes, WA 98221
Tel. (360) 421-1901
DESIGN CRITERIA:
Project Data:Zoning: Old Town
Lot Size: 6,098 SF (0.14 acres)
Lot Coverage: No change
Building Areas: No change
Jurisdiction:City of Anacortes
Building Code:2021 IRC
Energy Code:2021 WSEC-R
Energy Efficiency:See attached 2021 WSEC-R 2nd Edition
Remodel / Alterations Worksheet.
GENERAL NOTES:
- All dimensions to face of framing.
- GC to verify all dimensions in field.
CITY OF ANACORTES
PLANNING AND BUILDING DEPT:
APPROVED PLANS
REVIEWED FOR CODE COMPLIANCE
PERMIT #:______________________________
ADDRESS:____ _______________
APPROVED BY: ______________
SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT
BE ALTERED WITHOUT AUTHORIZATION.
BLD-2024-0502
1301 6th St
(E) KITCHEN
TO BE REMODELED
(E) BATH
TO BE REMODELED
(E) RESIDENCE
NO WORK TO BE DONE
(E) RESIDENCE
NO WORK TO BE DONE
Kreider Design Studio
1010 22nd Street
Anacores, WA 98221
tel. 360-540-4806
kreider.gaven@gmail.com
kreiderdesignstudio.com
KDS
TO
M
A
S
R
E
S
I
D
E
N
C
E
13
0
1
6
t
h
S
t
.
An
a
c
o
r
t
e
s
,
W
A
9
8
2
2
1
PE
R
M
I
T
S
E
T
SHEET TITLE:
ISSUE DATE:
7.16.2024
(E) FLOOR PLAN
A2.1
1 1/4" = 1'-0"
(E) FLOOR PLAN NORTH
(E) KITCHEN
(E) BATH
4'-0"
4'-0"
replace (e) windows with
(n) windows per owner
demo all (e) cabinetry, typ.
(E) RESIDENCE
NO WORK TO BE DONE
(E) RESIDENCE
NO WORK TO BE DONE
Kreider Design Studio
1010 22nd Street
Anacores, WA 98221
tel. 360-540-4806
kreider.gaven@gmail.com
kreiderdesignstudio.com
KDS
TO
M
A
S
R
E
S
I
D
E
N
C
E
13
0
1
6
t
h
S
t
.
An
a
c
o
r
t
e
s
,
W
A
9
8
2
2
1
PE
R
M
I
T
S
E
T
SHEET TITLE:
ISSUE DATE:
7.16.2024
DEMO PLAN
A2.2
1 1/4" = 1'-0"
DEMO PLAN NORTH
(N) BATH
breakfast bar
w/ rolling cart below
pantry
(N) KITCHEN
36" ref.
dw
combo
wall
oven /
m.w.
2
3
1
1
A6.14
2
3
1
1A6.24
(n) windows per owner,
max. u-value = 0.30
counter 2'-1"
2'-8"
new wood flooring
new tile flooring
corner sink
per owner
18" counter
18
"
c
o
u
n
t
e
r
50
hood at
range, vent
to outside100
min.
UP
H.R. @ 34"
(e) stair to remain
12" shelves
(E) RESIDENCE
NO WORK TO BE DONE
(E) RESIDENCE
NO WORK TO BE DONE
Kreider Design Studio
1010 22nd Street
Anacores, WA 98221
tel. 360-540-4806
kreider.gaven@gmail.com
kreiderdesignstudio.com
KDS
TO
M
A
S
R
E
S
I
D
E
N
C
E
13
0
1
6
t
h
S
t
.
An
a
c
o
r
t
e
s
,
W
A
9
8
2
2
1
PE
R
M
I
T
S
E
T
SHEET TITLE:
ISSUE DATE:
7.16.2024
(N) FLOOR PLAN
A2.3
1 1/4" = 1'-0"
(N) FLOOR PLAN NORTH
36" oven
24"
DW
breakfast bar
w/ rolling cart
microwave
36"
REF/
FRZ
pa
i
n
t
e
d
ca
b
i
n
e
t
pa
i
n
t
e
d
w
d
.
pa
n
e
l
op
e
n
w
o
o
d
sh
e
l
v
e
s
re
p
l
a
c
e
.
wi
n
d
o
w
s
pe
r
o
w
n
e
r
(e
)
d
o
o
r
+9'-0"
+3'-0"
+9'-0"
ro
o
m
be
y
o
n
d
(n
)
p
a
n
t
r
y
do
o
r
ma
t
c
h
e
x
i
s
t
.
ba
s
e
b
o
a
r
d
st
o
n
e
ba
c
k
s
p
l
a
s
h
fa
u
c
e
t
p
e
r
ow
n
e
r
+9'-0"
+3'-0"
ro
o
m
be
y
o
n
d
(e
)
b
r
i
c
k
,
fi
n
i
s
h
p
e
r
ow
n
e
r
pa
i
n
t
e
d
fr
i
d
g
e
pa
n
e
l
pa
i
n
t
e
d
ca
b
i
n
e
t
+5'-0"+5'-0"
6"
s
t
o
n
e
ba
c
k
s
p
l
a
s
h
gw
b
gw
b
gw
b
gw
b
gw
b
wall oven
(e) stair
1 2
3 4
pa
i
n
t
e
d
ra
n
g
e
h
o
o
d
co
v
e
r
PT-01 PT-01
PT-01 PT-01
ST-01 ST-01
ST-01
Kreider Design Studio
1010 22nd Street
Anacores, WA 98221
tel. 360-540-4806
kreider.gaven@gmail.com
kreiderdesignstudio.com
KDS
TO
M
A
S
R
E
S
I
D
E
N
C
E
13
0
1
6
t
h
S
t
.
An
a
c
o
r
t
e
s
,
W
A
9
8
2
2
1
PE
R
M
I
T
S
E
T
SHEET TITLE:
ISSUE DATE:
7.16.2024
INTERIOR
ELEVATIONS
A6.1
1 3/8" = 1'-0"
KITCHEN ELEVATION
+3'-0"
gla
s
s
sh
o
w
e
r
do
o
r
gl
a
s
s
sh
o
w
e
r
(e
)
w
i
n
d
o
w
(e
)
d
o
o
r
(e
)
d
o
o
r
si
n
k
p
e
r
ow
n
e
r
si
n
k
p
e
r
ow
n
e
r
+3'-0"+3'-0"
ti
l
e
ti
l
e
ti
l
e
h
a
l
f
wa
l
l
+7'-0"
+7'-0"
gw
b
gw
b
ti
l
e
ti
l
e
1 2
3 4
PT-02 PT-02
PT-02
T-02
T-02
PT-02
T-02
gw
b
gw
b
Kreider Design Studio
1010 22nd Street
Anacores, WA 98221
tel. 360-540-4806
kreider.gaven@gmail.com
kreiderdesignstudio.com
KDS
TO
M
A
S
R
E
S
I
D
E
N
C
E
13
0
1
6
t
h
S
t
.
An
a
c
o
r
t
e
s
,
W
A
9
8
2
2
1
PE
R
M
I
T
S
E
T
SHEET TITLE:
ISSUE DATE:
7.16.2024
INTERIOR
ELEVATIONS
A6.2
1 3/8" = 1'-0"
BATH ELEVATION
Are the windows and/or doors being replaced?
If yes,
New windows and doors (+frames) must
have an area weighted average U-factor of
≤0.30
Will the heating or cooling system be replaced?
If yes,
New equipment must meet current
requirements and the ducts need to be
tested
Will the hot water system be altered?
If yes,
New water heating equipment must
meet current code requirements
Are more than 10% of the light fixtures being
changed?
If yes,
100% of all lamps must be high
efficacy
2021 WSEC-R 2nd Edition
Remodel / Alteration Worksheet
Will you be exposing the walls?
If yes,
2 X 4 wall studs require R-15 insulation
2 X 6 wall studs require R-21 insulation
If siding is replaced C.I. equal to R-5 may need installed
under the siding.
Will the roof/ceiling framing cavities or attic be exposed?
If yes,
Exposed roof or ceiling assemblies must be insulated -
Vaulted ceilings, Insulate to the full depth of the
framing member
Flat ceilings, install R-60 insulation or what the
attic space can accommodate based on the roof
pitch
Will the will the floor framing cavities be exposed?
If yes,
Exposed floor cavities must be insulated to R-30
Yes Yes Yes
Yes Yes Yes Yes
No No
No No No No
No
R503.1.1.1 Replacement fenestration.
Where some or all of an existing fenestration unit is replaced with a new fenestration product, including sash and glazing,
the replacement fenestration unit shall meet the applicable requirements for U-factor and SHGC in Table R402.1.3. Where
more than one replacement fenestration unit is being installed, an area-weighted average of the U-factor and SHGC of all
replacement fenestration shall be permitted to be used to demonstrate compliance.
R503.1.1 Building envelope.
Building envelope assemblies that are part of the alteration shall comply with Section R402.1.3 or R402.1.5, Sections
R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.3.5 and R402.4.2.
Exception: The following alterations need not comply with the requirements for new construction provided the energy use
of the building is not increased:
1.Storm windows installed over existing fenestration.
2.Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with
insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a
minimum of R-21.
3.Construction where the existing roof, wall or floor cavity is not exposed.
4.Roof recover.
5.Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be
insulated either above or below the sheathing.
6.Surface-applied window film installed on existing single pane fenestration assemblies to reduce solar heat gain
provided the code does not require the glazing fenestration to be replaced.
R503.2 Change in space conditioning. Any non-conditioned or low-energy space
that is altered to become conditioned space shall be required to be brought into
full compliance with this (WSEC-R) code.
R502.1.1.2 Heating and cooling systems.
New heating, cooling and duct systems that are part of the addition shall comply with Section R403.
Exception:
The following need not comply with the testing requirements of Section R403.3.3:
1.Additions of less than 750 square feet.
2.Duct systems that are documented to have been previously sealed as confirmed through field verification
and diagnostic testing in accordance with procedures in WSU RS-33.
3.Ducts with less than 40 linear feet in unconditioned spaces.
4.Existing duct systems constructed, insulated or sealed with asbestos.
R503.1.4 Lighting.
New lighting systems that are part of the alteration shall comply with Section R404.1.
Exception: Alterations that replace less than 10 percent of the luminaires in a space, provided that such
alterations do not increase the installed interior lighting power.
R503.1.3 Service hot water systems.
New service hot water systems that are part of the alteration shall comply with Section R403.5.
R503.1.2 Heating and cooling systems.
New heating, cooling and duct systems that are part of the alteration shall comply with Section R403.
Exceptions:
1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear
feet in unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2
2. Existing duct systems constructed, insulated or sealed with asbestos.