Loading...
HomeMy WebLinkAboutPermit File BLD-2024-0055 705 Saint Mary's Drive (2)For inspections, please call (360) 293-1901 PARCEL: P79420 LEGAL DESCRIPTION: APPLICANT: PM, General 2500 Mottman RD SW suite 100 Tumwater, WA 98512 3607776681 OWNER: GRAN DANA UNKNOWN ANACORTES, WA 98221 VALUATIONS: Entered valuation 5640.00 $5,640.00 $5,640.00Total: FEES:Paid Due State Building Code Council fee $6.50 $0.00 Building Permit Fee $125.25 $0.00 Plan Review Fee $81.41 $0.00 $0.00Totals : REQUIRED INSPECTIONS Building Final $213.16 BLD-2024-0055 SOLAR PERMIT ISSUED: EXPIRES: 01/26/2024 07/26/2025 PROJECT NAME: SOLAR PROJECT- GRAN SITE ADDRESS: 705 ST MARYS DR ANACORTES * If you answered yes to all of the above questions, your PV installation is eligible for a building permit. CONDITIONS Page 1 of 1Printed by : Cheri Gleichmann on: 08/02/2024 11:29 AM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1902 http://cityofanacortes.org/ COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 705 SAINT MARYS DR, ANACORTES, WA 98221, USA REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-0 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 06 MODULES-ROOF MOUNTED - 2.400 kWDC, 1.740 kWAC GOVERNING CODES: 2020 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2018 INTERNATIONAL FIRE CODE 2018 WASHINGTON STATE ENERGY CODE 2018 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 UNIFORM PLUMBING CODE 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 SHEET INDEX PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLANPV-2 ROOF PLAN WITH MODULESPV-3 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM WITHCALCULATION PV-5 WARNING LABELS & PLACARD PV-6 SAFETY PLANPV-7+ EQUIPMENT SPEC SHEETS NOTES: 1. PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED INACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018 IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLE REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVINGJURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTEDWITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13, 705.10 AND 706.15. 2. PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITHTHE WIRING METHODS AND INSTALLATION AND MARKINGREQUIREMENTS OF NEC 690.31(D). 3. BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND "BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKERALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING ACVOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUITBREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUTCONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PER NEC 705.12 (B)(3)(2). 4. WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING"WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION." 5. LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCH TO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADEDISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC705.22. 6. LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE,MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH LOCKED PER NEC 690.13(B). 7. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWERINVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B).8. LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED) 9. BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY. 10. DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOTTO BE ADDED TO THIS PANEL."11. ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND ATTACHED PER APPROVED METHOD. 12. LABEL "BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2)." NO NEWLOADS.13. EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINES DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR. 14. WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIREREADS "SUNLIGHT RESISTANT."15. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC GROUNDING ELECTRODE SYSTEM PER NEC 250.64(B).16. AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2). CONDUIT ELEVATED MIN. 1/2"; ADDER 33 DEG F.17. ALL EXTERIOR EQUIPMENT TO BE NEMA 3R.18. THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITSMAY BE EXPOSED DURING SERVICE: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SYSTEM SUMMARY:(N) 06 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES(N) 06 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS [240V] (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) ENPHASE IQ COMBINER BOX 4 [240V]X2-IQ-AM1-240-4 (IEEE 1547:2018) (N) 30A NON-FUSED VISIBLE, LOCKABLE, LABELED AC DISCONNECTKNIFE SWITCH [240V] ROOF TYPE: - ASPHALT SHINGLES NUMBER OF LAYERS: - 01ROOF FRAME: - 2"X6" TRUSSES @ 24" O.C.STORY: - ONE STORY SNOW LOAD : - 15 PSF WIND SPEED :- 98 MPHWIND EXPOSURE:- CRISK CATEGORY:- II COORDINATE:- 48.486318, -122.608666 DESIGN CRITERIA: UTILITY METER NO: X173465326 CITY OF ANACORTES PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT #:______________________________ ADDRESS:____ _______________ APPROVED BY: ______________ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. BLD-2024-0055 705 St Mary's Dr PV systems shall not be installed in locations that would restrict the function of plumbing or mechanical vents, skylights, drains or other rooftop features. Vents that serve as exhaust for dryers, bathrooms, and attics, may not have solar panels installed over them. These vents must remain unobstructed by solar panels. ACD MSPUMCB JB 33 ' - 8 " 20'-0" 6'-8" 27 ' - 9 " ~73.51' ~1 2 8 . 4 5 ' ~1 4 8 . 9 5 ' ~28 . 6 0 ' ~26.73'~18.53' ACD MSP UMCB JB SITE PLAN WITH ROOF PLAN REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-1 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SITE PLAN WITH ROOF PLAN 1 SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE: THE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH IS LOCATED WITHIN 10FT OF UTILITY METER NOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE) LEGEND JUNCTION BOXJB MSP MAIN SERVICE PANEL TREES ENPHASE IQ COMBINER BOX 4 X2-IQ-AM1-240-4 (IEEE 1547:2018)CB UTILITY METERUM VENT, ATTIC FAN (ROOF OBSTRUCTION) PROPERTY LINE VISIBLE, LOCKABLE, LABELED ACDISCONNECT KNIFE SWITCHACD NOTE : NO FENCE SURROUNDING THE PROPERTY LINE. SAINT MARYS DR EXISTING DRIVEWAY ONE- STORY HOUSE (E) PATIO PV systems shall not be installed in locations that would restrict the function of plumbing or mechanical vents, skylights, drains or other rooftop features. Vents that serve as exhaust for dryers, bathrooms, and attics, may not have solar panels installed over them. These vents must remain unobstructed by solar panels. ACD MSP UMCB JB 3'-0"13'-9"19'-8"6'-10"3'-2" 10 ' - 4 " 5' - 8 " 2'- 9 " REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-2 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 1/8" = 1'-0"1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 06 MODULES MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t(400W) MODULESMODULE WEIGHT = 48.5 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.30 PSF NOTE: ACTUAL ROOF CONDITIONS ANDTRUSSES LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF SURFACE) ARRAY AREA & ROOF AREA CALC'S AREA OF NEW ARRAY(Sq. Ft.) AREA OF ROOF(PLANVIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 126.73 2718 4.66% ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAYAREA(Sq. Ft.) ROOFAREA (Sq. Ft.) ROOFAREACOVERED BYARRAY (%) #1 06 126.73 535.00 23.69 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLESROOF ROOF ROOFTILT AZIMUTH TRUSSESSIZE TRUSSESSPACING #1 23° 182° 2"x6"24" O.C. LEGEND VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT UNIRAC STRONGHOLD BUTYL @ 48" O.C. TRUSSES JUNCTION BOXJB MSP MAIN SERVICE PANEL FIRE PATHWAY UNIRAC NXT UMOUNT RAIL ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS ENPHASE IQ COMBINER BOX 4 X2-IQ-AM1-240-4 (IEEE 1547:2018)CB UTILITY METERUM VISIBLE, LOCKABLE, LABELED ACDISCONNECT KNIFE SWITCHACD BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 4 UNIRAC NXT UMOUNT RAIL 168" DRK RAIL SPLICE 0 NXT UMOUNT RAIL SPLICE UNIVERSAL CLAMP 16 NXT UMOUNT COMBO CLAMP DRK ROOFATTACHMENTS 13 UNIRAC STRONGHOLD BUTYL ACCESSORIES 8 NXT UMOUNT RL & CLMP CAP KIT MLPE & GROUNDING 8 NXT UMOUNT MLPE & LUG CLAMP SAINT MARYS DR FRONT YARD REAR YARD 18" FIRE PATHWAY 18" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y ROOF #1 NOTE: THE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFESWITCH IS LOCATED WITHIN 10FT OF UTILITY METER PV systems shall not be installed in locations that would restrict the function of plumbing or mechanical vents, skylights, drains or other rooftop features. Vents that serve as exhaust for dryers, bathrooms, and attics, may not have solar panels installed over them. These vents must remain unobstructed by solar panels. REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-3 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS (E) 2"X6" TRUSSE S @ 24" O.CENLARGE VIEW (N) PV MODULES (E) ASPHALT SHINGLES ROOF (N) NXT UMOUNT COMBO CLAMP (N) PV MODULES (N) NXT UMOUNT RAIL (N) NXT UMOUNT RAIL CLAMP ASSY (E) ROOF / DECK MEMBRANE (E) ASPHALT SHINGLES ROOF 5/16"-18 x 2" SERRATED FLANGE HEX SCREW ~4 " ~ 4 " 1-3/4" MIN. EMBEDMENT 1 . 2 6 " 1. 2 6 " (N) DTD BUTYL ATT ASSY (1/8" BUTYL) 2X12-14 SCREW, HWH, SS, SELF-DR W/ #12 EPDM WASHER (N) STRONGHOLD BUTYL ATTACHMENTS, DRK REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-4 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 ELECTRICAL LINE DIAGRAM & CALCULATION ELECTRICAL LINE DIAGRAM WITH CALCULATION SCALE: NTS1 L 200A EXISTINGGROUNDINGSYSTEM (E) MAIN BREAKER200A/2P, 240V 20A/2P (N) 20A/2P PVBREAKER (E) MAINSERVICE PANEL,200A RATED,120/240V BI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60Hz G (N) 30ANON-FUSED,VISIBLE,LOCKABLE, LABELED ACDISCONNECT KNIFESWITCH, 240 VAC N N L2 L1 L2 L1 VLL AC DISCONNECT KNIFE SWITCH SHALL BE LOCATED WITHIN 10' OF UTILITY METER INTERCONNECTION 120% RULE - NEC 705.12(B)(3)(2) UTILITY FEED + SOLAR BACKFEED 200A + 20A = 220A BUSS RATING x 120% 200A x 120% = 240A C NOTE: THE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFESWITCH IS LOCATED WITHIN 10FT OF UTILITY METER ·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/ORDISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ(AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLECODES. ·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN TO INVERTER. ·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BEPROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64). ·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THENEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. ·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC300.6 C1, 310.8 D). ·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. ·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED. UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: PSE 240V EATON (E) 200A (E) 200A SOUTH SERVICE INFO. UNDERGROUND NOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE) SYSTEM SIZE:- 06 x 400W = 2.400 kWDC 06 x 290VA = 1.740 kWAC INVERTER SPECIFICATIONS MANUFACTURER / MODEL #QUANTITY NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENTENPHASE ENERGYIQ8PLUS-72-2-US 06 240 VAC 1.21A (06) ENPHASE ENERGYIQ8PLUS-72-2-USMICRO-INVERTERS (240V)(LOCATED UNDER EACH PANEL) (N) JUNCTION BOX G NG TERMINATOR CAP ON LAST CABLECONNECTOR Q- CABLE (TYP) 10A/15A M*IQ-GATEWAY 20A 06 MICRO-INVERTERS IN BRANCH #1 L1L1 L2L2 (N) ENPHASE IQCOMBINER BOX 4X2-IQ-AM1-240-4(IEEE1547:2018) [240V] A B AMBIENT TEMPERATURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP(HIGH TEMP 2%) CONDUCTORTEMPERATURERATE -10°26°90° NOTE-EQUIPMENT RATED AT 75 DEGREES Wire Tag Conduit Wire Qty WireGauge Wire Type Temp.Rating WireAmpacity (A)Temp.Derate ConduitFill Derate DeratedAmpacity (A)InverterQty NOC (A)NECCorrection DesignCurrent (A)GroundSize Ground WireType A OPEN AIR 1 12 AWG Q Cable 90°C 30 1.00 N/A 30.00 06 1.21 1.25 9.08 06 AWG BARE CU B 3/4" EMT 2 12 AWG THWN-2 90°C 30 1.00 1.0 30.00 06 1.21 1.25 9.08 06 AWG THWN-2 C 3/4" EMT 3 10 AWG THWN-2 90°C 40 1.00 1.0 40.00 06 1.21 1.25 9.08 10 AWG THWN-2 UTILITY METER NO: X173465326 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VMP (V) IMP (A) VOC (V) ISC (A) TEMPERATURECOEFFICIENTOF Voc # OF MODULES HANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ / t (400W)38.09 10.50 45.55 11.07 -0.27%/K 06 MODULE DIMENSION 74.0" L x 41.1" W x 1.26" D CONSUMPTIONCT's REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-5 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 WARNING LABELS & PLACARD POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 705 SAINT MARYS DR (E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER(E) UTILITY METER (N) 30A NON-FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 4 (N) PV MODULES CAUTION ! MULTIPLE SOURCES OF POWER WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC690.31(D)(2) PHOTOVOLTAIC POWER SOURCE LABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.12(D)(3) & NEC 690.59) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITION LABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2020: NEC 690.13(B)& NEC 690.15(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 7.26 AMPS 240 VAC LABEL LOCATION:VLL AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2020: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRICPV PANELS TURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWN PV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY. LABEL LOCATION:MAIN SERVICE PANEL.PER CODE(S): NEC 2020: IFC 605.11.3.1(1) & 690.56(C) ! 3" 3" PHOTOVOLTAIC SYSTEM AC DISCONNECT MAIN PHOTOVOLTAICSYSTEM DISCONNECT LABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B)) LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER (WITHIN 3FT),INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2020: 690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM ! WARNING THE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT ! LABEL LOCATION:COMBINER BOX PER CODE: NEC 690.31(E) THIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKERCODE: NEC 705.12(B)(3)(3) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDSPANEL RATINGNEC 705.12 (B)(3)(2) ! LABEL LOCATION:MSP (PER CODE: NEC 705.12(D)(2) &NEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! PHOTOVOLTAIC KNIFE SWITCH LABEL LOCATION:VISIBLE, LOCKABLE, LABELED ACDISCONNECT KNIFE SWITCHNEC 690.13(B) REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-6 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SAFETY PLAN SYSTEM SIZE:- 06 x 400W = 2.400 kWDC 06 x 290VA = 1.740 kWAC SAFETY PLAN SCALE: NTS1 INSPECT ENTIRE JOB SITE FOR HAZARDS SAFETY PLAN CHECKLIST ABBR. INDICATE PARKING LOCATION FOR COMPANY VEHICLES SD CV INDICATE LOCATION OF SAFETY DOCUMENTS FIRE EXTINGUISHER LOCATION FE H FIRST AID KIT LOCATION FA EYE WASH LOCATION EW DRINKING WATER LOCATION DW IDENTIFY HARD HAT ZONE HHZ DRAW FALL PROTECTION ANCHOR LOCATION X DRAW LADDER & ROOF ACCESS LOCATION L DRAW LADDER ANCHOR LOCATION LA IDENTIFY ELECTRICAL HAZARD AREAS EH INDICATE OTHER HAZARD LOCATION AND SPECIFY (E.G. WATER,TRIPPING,ANIMALS,INSECTS,ETC.) WEATHER FORECAST HOURLYHEAT INDEX HIPP MEASURES 7 AM 8 AM 9 AM 10 AM 11 AM 12 AM 1 AM 2 AM 3 AM 4 AM 5 AM OTHER WEATHER RELATED HAZARDS & MEASURES WET OR ICY SURFACES HIGH WINDS THUNDER STOMS WILDFIRE SMOKE OTHER ADDRESS & PHONE NUMBER OF CLOSEST URGENT CARE FACILTY CREW LEAD SIGNATURE & DATE(S) CREW LEAD SIGNATURE & DATE(S) NOTE: CREW LEAD MUST CONDUCT A DAILY MEETING TO REVIEW ALL SAFTEY ITEMS. 1 2 3 4 5 NOTE: FOR MULTIPLE DAY JOBS,SAFETY MEETINGS MUST BE CONDUCTED EACH DAY.INDICATE BY INITIALING NEXT TO YOUR SIGNATURE FOR EACH ADDITIONAL DAY. SAINT MARYS DR REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-7 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-8 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-9 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-10 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-11 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-12 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-13 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-14 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-15 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-16 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-17 PROJECT NAME SHEET SIZE ANSI B11" X 17" DA N A G R A N 70 5 S A I N T M A R Y S D R , AN A C O R T E S , W A 9 8 2 2 1 , U S A AP N # P 7 9 4 2 0 UT I L I T Y : P S E AH J : C I T Y O F A N A C O R T E S PR O J E C T N U M B E R : P - 0 0 9 2 8 9 7 SPEC SHEETS COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 705 SAINT MARYS DR, ANACORTES, WA 98221, USA REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-0 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED 06 MODULES-ROOF MOUNTED - 2.400 kWDC, 1.740 kWAC GOVERNING CODES: 2020 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2018 INTERNATIONAL FIRE CODE 2018 WASHINGTON STATE ENERGY CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 UNIFORM PLUMBING CODE 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 SHEET INDEX PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM WITH CALCULATION PV-5 WARNING LABELS & PLACARD PV-6 SAFETY PLAN PV-7+EQUIPMENT SPEC SHEETS NOTES: 1.PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018 IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLE REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVING JURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13, 705.10 AND 706.15. 2.PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITH THE WIRING METHODS AND INSTALLATION AND MARKING REQUIREMENTS OF NEC 690.31(D). 3.BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND "BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKER ALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING AC VOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUIT BREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PER NEC 705.12 (B)(3)(2). 4.WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING "WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION." 5.LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCH TO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADE DISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22. 6.LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC 690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH LOCKED PER NEC 690.13(B). 7.LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B). 8.LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED) 9.BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY. 10.DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOT TO BE ADDED TO THIS PANEL." 11.ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND ATTACHED PER APPROVED METHOD. 12.LABEL "BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2)." NO NEW LOADS. 13.EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINES DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR. 14.WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIRE READS "SUNLIGHT RESISTANT." 15.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC GROUNDING ELECTRODE SYSTEM PER NEC 250.64(B). 16.AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2). CONDUIT ELEVATED MIN. 1/2"; ADDER 33 DEG F. 17.ALL EXTERIOR EQUIPMENT TO BE NEMA 3R. 18.THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SYSTEM SUMMARY: (N) 06 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES (N) 06 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS [240V] (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) ENPHASE IQ COMBINER BOX 4 [240V] X2-IQ-AM1-240-4 (IEEE 1547:2018) (N) 30A NON-FUSED VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH [240V] ROOF TYPE: - ASPHALT SHINGLES NUMBER OF LAYERS: - 01 ROOF FRAME: - 2"X6" TRUSSES @ 24" O.C. STORY: - ONE STORY SNOW LOAD : - 15 PSF WIND SPEED :- 98 MPH WIND EXPOSURE:- C RISK CATEGORY:- II COORDINATE:- 48.486318, -122.608666 DESIGN CRITERIA: UTILITY METER NO: X173465326 ACD MSP UMCB JB 33 ' - 8 " 20'-0" 6'-8" 27 ' - 9 " ~73.51' ~1 2 8 . 4 5 ' ~1 4 8 . 9 5 ' ~2 8 . 6 0 ' ~26.73'~18.53' MSP UM JB ACD CB SITE PLAN WITH ROOF PLAN REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-1 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SITE PLAN WITH ROOF PLAN 1 SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE: THE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH IS LOCATED WITHIN 10FT OF UTILITY METER NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF SURFACE) LEGEND JUNCTION BOXJB MSP MAIN SERVICE PANEL TREES ENPHASE IQ COMBINER BOX 4 X2-IQ-AM1-240-4 (IEEE 1547:2018)CB UTILITY METERUM VENT, ATTIC FAN (ROOF OBSTRUCTION) PROPERTY LINE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCHACD NOTE : NO FENCE SURROUNDING THE PROPERTY LINE. SAINT MARYS DR EXISTING DRIVEWAY ONE- STORY HOUSE (E) PATIO A ACD MSP UMCB JB 3'-0"10'-4"33'-1" 1' - 2 " 14 ' - 1 1 " 2' - 9 " REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-2 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 1/8" = 1'-0"1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 06 MODULES MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES MODULE WEIGHT = 48.5 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.30 PSF NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF SURFACE) ARRAY AREA & ROOF AREA CALC'S AREA OF NEW ARRAY (Sq. Ft.) AREA OF ROOF(PLAN VIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 126.73 2718 4.66% ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 06 126.73 535.00 23.69 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLES ROOF ROOF ROOF TILT AZIMUTH TRUSSES SIZE TRUSSES SPACING #1 23°182°2"x6"24" O.C. LEGEND VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT UNIRAC STRONGHOLD BUTYL @ 48" O.C. TRUSSES JUNCTION BOXJB MSP MAIN SERVICE PANEL FIRE PATHWAY UNIRAC NXT UMOUNT RAIL ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS ENPHASE IQ COMBINER BOX 4 X2-IQ-AM1-240-4 (IEEE 1547:2018)CB UTILITY METERUM VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCHACD BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 5 UNIRAC NXT UMOUNT RAIL 168" DRK RAIL SPLICE 0 NXT UMOUNT RAIL SPLICE UNIVERSAL CLAMP 18 NXT UMOUNT COMBO CLAMP DRK ROOF ATTACHMENTS 17 UNIRAC STRONGHOLD BUTYL ACCESSORIES 12 NXT UMOUNT RL & CLMP CAP KIT MLPE & GROUNDING 9 NXT UMOUNT MLPE & LUG CLAMP SAINT MARYS DR FRONT YARD REAR YARD 18" FIRE PATHWAY 18" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y ROOF #1 NOTE: THE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH IS LOCATED WITHIN 10FT OF UTILITY METER A A REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-3 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS (E) 2"X6" TRUSS E S @ 24" O.CENLARGE VIEW (N) PV MODULES (E) ASPHALT SHINGLES ROOF (N) NXT UMOUNT COMBO CLAMP (N) PV MODULES (N) NXT UMOUNT RAIL (N) NXT UMOUNT RAIL CLAMP ASSY (E) ROOF / DECK MEMBRANE (E) ASPHALT SHINGLES ROOF 5/16"-18 x 2" SERRATED FLANGE HEX SCREW ~4 " ~ 4 " 1-3/4" MIN. EMBEDMENT 1 . 2 6 " 1. 2 6 " (N) DTD BUTYL ATT ASSY (1/8" BUTYL) 2X12-14 SCREW, HWH, SS, SELF-DR W/ #12 EPDM WASHER (N) STRONGHOLD BUTYL ATTACHMENTS, DRK REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-4 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED ELECTRICAL LINE DIAGRAM & CALCULATION ELECTRICAL LINE DIAGRAM WITH CALCULATION SCALE: NTS1 L 200A EXISTING GROUNDING SYSTEM (E) MAIN BREAKER 200A/2P, 240V 20A/2P (N) 20A/2P PV BREAKER (E) MAIN SERVICE PANEL, 200A RATED, 120/240V BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz G (N) 30A NON-FUSED,VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH, 240 VAC N N L2 L1 L2 L1 VLL AC DISCONNECT KNIFE SWITCH SHALL BE LOCATED WITHIN 10' OF UTILITY METER INTERCONNECTION 120% RULE - NEC 705.12(B)(3)(2) UTILITY FEED + SOLAR BACKFEED 200A + 20A = 220A BUSS RATING x 120% 200A x 120% = 240A C NOTE: THE VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH IS LOCATED WITHIN 10FT OF UTILITY METER ·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ (AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES. ·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN TO INVERTER. ·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64). ·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. ·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC 300.6 C1, 310.8 D). ·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. ·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED. UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: PSE 240V EATON (E) 200A (E) 200A SOUTH SERVICE INFO. UNDERGROUND NOTE: 3/4" OR GREATER EMT CONDUIT RUN (7/8" ABOVE ROOF SURFACE) SYSTEM SIZE:- 06 x 400W = 2.400 kWDC 06 x 290VA = 1.740 kWAC INVERTER SPECIFICATIONS MANUFACTURER / MODEL #QUANTITY NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT ENPHASE ENERGY IQ8PLUS-72-2-US 06 240 VAC 1.21A (06) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS (240V) (LOCATED UNDER EACH PANEL) (N) JUNCTION BOX G N G TERMINATOR CAP ON LAST CABLE CONNECTOR Q- CABLE (TYP) 10A/15A M*IQ-GATEWAY 20A 06 MICRO-INVERTERS IN BRANCH #1 L1L1 L2L2 (N) ENPHASE IQ COMBINER BOX 4 X2-IQ-AM1-240-4 (IEEE1547:2018) [240V] A B AMBIENT TEMPERATURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%) CONDUCTOR TEMPERATURE RATE -10°26°90° NOTE-EQUIPMENT RATED AT 75 DEGREES Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp. Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A)NEC Correction Design Current (A) Ground Size Ground Wire Type A OPEN AIR 1 12 AWG Q Cable 90°C 30 1.00 N/A 30.00 06 1.21 1.25 9.08 06 AWG BARE CU B 3/4" EMT 2 12 AWG THWN-2 90°C 30 1.00 1.0 30.00 06 1.21 1.25 9.08 06 AWG THWN-2 C 3/4" EMT 3 10 AWG THWN-2 90°C 40 1.00 1.0 40.00 06 1.21 1.25 9.08 10 AWG THWN-2 UTILITY METER NO: X173465326 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VMP (V) IMP (A) VOC (V) ISC (A) TEMPERATURE COEFFICIENT OF Voc # OF MODULES HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W)38.09 10.50 45.55 11.07 -0.27%/K 06 MODULE DIMENSION 74.0" L x 41.1" W x 1.26" D CONSUMPTION CT's REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-5 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED WARNING LABELS & PLACARD POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 705 SAINT MARYS DR (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) 30A NON-FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 4 CAUTION ! MULTIPLE SOURCES OF POWER WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: EMT/CONDUIT RACEWAYS (PER CODE: NEC690.31(D)(2) PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER NEC 705.12(D)(3) & NEC 690.59) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: NEC 690.13(B) & NEC 690.15(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 7.26 AMPS 240 VAC LABEL LOCATION: VLL AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: MAIN SERVICE PANEL. PER CODE(S): NEC 2020: IFC 605.11.3.1(1) & 690.56(C) ! 3" 3" PHOTOVOLTAIC SYSTEM AC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: NEC 690.13(B)) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER (WITHIN 3FT), INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2020: 690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM ! WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! LABEL LOCATION: COMBINER BOX PER CODE: NEC 690.31(E) THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: NEC 705.12(B)(3)(3) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING NEC 705.12 (B)(3)(2) ! LABEL LOCATION: MSP (PER CODE: NEC 705.12(D)(2) & NEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! PHOTOVOLTAIC KNIFE SWITCH LABEL LOCATION: VISIBLE, LOCKABLE, LABELED AC DISCONNECT KNIFE SWITCH NEC 690.13(B) (N) PV MODULES A REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-6 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SAFETY PLAN SYSTEM SIZE:- 06 x 400W = 2.400 kWDC 06 x 290VA = 1.740 kWAC SAFETY PLAN SCALE: NTS1 INSPECT ENTIRE JOB SITE FOR HAZARDS SAFETY PLAN CHECKLIST ABBR. INDICATE PARKING LOCATION FOR COMPANY VEHICLES SD CV INDICATE LOCATION OF SAFETY DOCUMENTS FIRE EXTINGUISHER LOCATION FE H FIRST AID KIT LOCATION FA EYE WASH LOCATION EW DRINKING WATER LOCATION DW IDENTIFY HARD HAT ZONE HHZ DRAW FALL PROTECTION ANCHOR LOCATION X DRAW LADDER & ROOF ACCESS LOCATION L DRAW LADDER ANCHOR LOCATION LA IDENTIFY ELECTRICAL HAZARD AREAS EH INDICATE OTHER HAZARD LOCATION AND SPECIFY (E.G. WATER,TRIPPING,ANIMALS,INSECTS,ETC.) WEATHER FORECAST HOURLY HEAT INDEX HIPP MEASURES 7 AM 8 AM 9 AM 10 AM 11 AM 12 AM 1 AM 2 AM 3 AM 4 AM 5 AM OTHER WEATHER RELATED HAZARDS & MEASURES WET OR ICY SURFACES HIGH WINDS THUNDER STOMS WILDFIRE SMOKE OTHER ADDRESS & PHONE NUMBER OF CLOSEST URGENT CARE FACILTY CREW LEAD SIGNATURE & DATE(S) CREW LEAD SIGNATURE & DATE(S) NOTE: CREW LEAD MUST CONDUCT A DAILY MEETING TO REVIEW ALL SAFTEY ITEMS. 1 2 3 4 5 NOTE: FOR MULTIPLE DAY JOBS,SAFETY MEETINGS MUST BE CONDUCTED EACH DAY. INDICATE BY INITIALING NEXT TO YOUR SIGNATURE FOR EACH ADDITIONAL DAY. SAINT MARYS DR A REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-7 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-8 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-9 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-10 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-11 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-12 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-13 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-14 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-15 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-16 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS REVDATEDESCRIPTION VERSION UR12/05/2023INITIAL RELEASE SHEET NAME SHEET NUMBER PV-17 PROJECT NAME SHEET SIZE ANSI B 11" X 17" DA N A G R A N 70 5 SA I N T M A R Y S D R , AN A C O R T E S , WA 9 8 2 2 1 , U S A AP N # P7 9 4 2 0 UT I L I T Y : PS E AH J : CI T Y O F A N A C O R T E S PR O J E C T N U M B E R : P- 0 0 9 2 8 9 7 A01/31/2024LAYOUT CHANGED SPEC SHEETS