Laserfiche WebLink
LUV LoCM J <br /> iC+ N � Q <br /> N 00 00 <br /> J t <br /> UaN <br /> ■ �' E <br /> N H <br /> c r ne e ence <br /> W m J <br /> 1211 34th Street `" <br /> Z <br /> Anacortes , Washington 3Z <br /> W E <br /> U <br /> m <br /> m <br /> c <br /> c <br /> as <br /> m <br /> c <br /> .Q <br /> STANDARD DETAILS ABBREVIATIONS PROJECT INFORMATION <br /> 3 <br /> Nailing per Plan w/Spcg. AB Anchor Bolt Mas. Masonry CLIENT: <br /> 10 TYPICAL NOTCHING & BORING O TYPICAL FLOOR / ROOF NAILING Denoted as @ A", B", C" ® TYPICAL CONCRETE SLAB JOINTS z O TYPICAL REINFORCING BAR BENDS A&B Above and Below Max. Maximum John Macartney <br /> A= Boundary Nailing — Dimension per Details Abv. Above MB Machine Bolt 1211 34th Street <br /> Fill w/Joint Sealant 1/8" o � Adn. Addition al MF Moment Frame The use of these plans and specifications shall be <br /> PENETRATIONS IN TOP PLATES &SILL PLATES Edge Nailing Along Edge of B = Edge Nailing CL_ ( ) Anacortes, WA 98221 <br /> g g g g �,, 6'p, restricted to the original site for which they were prepared <br /> C = Field Adj. Adjacent, Adjustable Mfr. Manufacture(r) and publication thereof is expressly limited to such use. <br /> ea. Panel _ '� p p y <br /> M t y R d Z <br /> am <br /> Space Notches @ 1-1/4"O Max. Bored Holes = �? -0 Alt. Alternate (ive) Min. Minimum, Minute ARCHITECT/DESIGNER: Reproduction or publication by any method,in whole or in <br /> 72" o.c., Min. iv Boundary Nailing @ Edge Cont. Panel Joint 0 0 0 0 I� Appd. Approved Mod. Modif(y), (ication) Alexei Ford Design Build part,is prohibited. Title to these plans and specifications <br /> x Q - remain with Alpine Engineering,LLC. without prejudice. <br /> of Floor/Roof Frmg. Perp. to Frmg. Arch. Architect(ural) Mtl. Metal 228 E. Maple Street Visual contact with these plans and specifications shall <br /> .. ........ . Avg. Average N/A Not Applicable constitute prima facie evidence of the acceptance of these <br /> Exp. Joint 2 d O 4d g ry. BoundaryA of pplicable restrictions. <br /> 2-1/2" Min. (360)220-5452 <br /> _ _ - _ _ Bldg. Building Nat. Natural <br /> — 9 g <br /> = L Engineer of Record: <br /> L L 12d for#6 & Larger Blk . Block in NTS Not to Scale <br /> MSTA24, Center 3-1/2 1 -0 Min. 1 -0 Min. Li_ o . _ _ _ _ _ _ (g) ( g) <br /> .. = L CU <br /> L) — _ _ _ _ _ = 0 0 0 0 6d for#5 & Smaller <br /> on Notch = — _ = o ' a Bm. Beam o/ Over <br /> Max. o <br /> _ ._ . I y <br /> o C ' O <br /> BN Boundary Nailing oc On Center <br /> - - L: - rY 9 <br /> a� <br /> O B O Bottom of OD Outside Diameter , <br /> o . Su ested Notes: J <br /> 0 1 Pour <br /> Space Notches r <br /> n - - - N <br /> Q B B Others n Opening <br /> @ o <br /> '. O Ot e s O O e <br /> - - - � Y g• <br /> 2 O Max. Bored Holes <br /> 1. Pour Slab in Alt. Bays, 12 0 S . Max. <br /> Y q <br /> 72 o.c. Min. <br /> - - - - I Dimension er Details �. <br /> - - - - - - - _ _ _ _ X Bot. Bottom Opp. Opposite ,� <br /> 2. Slab May be Poured Monolithically if <br /> x - Sawcut @ 12'-0" Max. Ea. Way w Brg. Bearing Opt. Optional <br /> 2"d Pour Btwn. Between Para. Parallel <br /> _ _ 3. Exp. Joints Locations per ARCHITECT, DESIGN PARAMETERS <br /> N _ _ _ �� - UNO. STANDARD TIES &STIRRUPS STANDARD END HOOKS BW Both Ways PCF Lbs per Cubic Ft. <br /> . I .o <br /> } Cant. Cantilever ed Pen. Penetrate tion 4083 <br /> ( ) ( ) ,+ <br /> - - Bar Size D H A rox. Bar Size D J -�� <br /> pp ) 'Py <br /> - - - - � :�• - - - - - - CIP Cast in Place Perf. Perforated APPLICABLE CODES: � <br /> , „ „ <br /> „ „ „ <br /> t <br /> - CJ Ceiling Joist Perim. Perimeter� - #3 1 12 #3 214- / 3 / 3 <br /> 12 - - - 9 MSTA26 Center 5 / 1 0 Min. 1 o Min. - TYP. PENETRATION THROUGH FOUNDATION 2o18IBc T <br /> N I.:.. <br /> 5 <br /> O C PCompletei n t Per Perpendicular <br /> on Notch Max. - : �:�:� - - - #4 2 3 #4 3 4" J Jo p. <br /> - - - - - �:#.. The 2018 International BuildingCode IBC is the <br /> Ftg. Reinf. per Plan & Penetration PI Panel Index governing code in the State of Washington which <br /> _ _ _ _ _ _ _ #5 2-1/2 3-3/4 #5 3-3/4 5" g g g <br /> Details CL Center Line PJP Partial Joint Pen. references: <br /> Space Notches @ #6 4-1/2" 4-1/2" #6 4-1/2" 6" CI Ceiling PL Plate <br /> 72" o.c., Min. 3"O Max. Bored Holes This Panel Joint Not Cont. Field Nailing Typ. to g• g ASCE 7-16 <br /> Provide Blkg. & Edge All Frmg. Members #7 5-1/4" 5-1/4" #7 5-1/4" 7" CMU Conc. Masonry Unit PLF Lbs per Linear Ft. NDS 2018 <br /> ° #8 6" 6" #8 6" 8" Col. Column PI. Plate AC1318-14 <br /> x Nailing at Perp. Panel JointsL Provide BN @ SW's & °' Com. Common Ply. Plywood <br /> `° as Occurs per Plan AISC 14r"EDITION <br /> >� �., g p Collector/Drag Members as 06 Note: Comp. Component Prep. Prepare, (tion) <br /> SW as Occurs per Plan Occurs per Plan q_1AP <br /> 0 All Bar Bend Diameters & End Lengths Must Conc. Concrete Press. Pressure SDPWS 2015 <br /> 71 M Conform to the CRSI Manual of Standard Practice Conn. Connection Proj. Project STRUCTURAL LOADS <br /> N Const. Construction Prop. Property <br /> m RoofLoads <br /> MSTA26, Center 5-1/2" V-0" Min. V-0" Min. O Cont. Continue (ous) PSF Lbs per Square Ft. Dead Loads (DL) 16 psf <br /> on Notch Max. TYPICAL 2x TOP PLATE SPLICE STD. DEVELOPMENT LENGTHS & LAP SPLICES Ctr. Center PSI Lbs per Square In. Live Loads (LL) 20 psfd Penny PT Pressure-Treated Snow Loads (S) 25 psf <br /> Dbl. Double R Radius Floor Loads-T <br /> NOTCHING LIMITS FOR WOOD STUDS BORING LIMITS FOR WOOD STUDS Before Next Splice: Yp /1�2x4 Dbl. TP-4'-0" Splice w/ (30) 16d Nails Defl. Deflection Rec(s). Recommendations) V/2x4- (30) 16d Nails ,_ U oebl. Ties @ ea. Dead Loads (DL) 15 psf2x6 Dbl. TP- 5 4 Splice w/ (46) 16d Nails Duct or Pipe Peeraon Deg. Degree Rect. Rectangular <br /> 2x6- 46 16d Nails Bot. Reinf. Bend Loc. U .E Live Loads (LL) 40 psf <br /> ( ) per Mech. or Plumb. Plans g Demo. Demolish (tion) Ref. Reference p <br /> Ties: Floor Loads- Deck <br /> Dep. Depressed) Reinf. Reinforce(d), (ment), ■� i-' <br /> DO NOT Locate Pen. w/n (� Ftg. Reinf. = (1) Bar T&B, Use U .� Dead Loads (DL) 10 psf <br /> L ° � � DF Douglas Fir (ing) <br /> 24" of Any Holdowns #3 Vert. w/ 180 Hook ea. End Dia. Diameter Req(d). Require(d) <br /> Live Loads (LL) 60 psf ._ <br /> 0.6w 0.4w 1 Ftg. Reinf. > (1) Bar T&B, Use <br /> Max. Max. Splice TP over U #3 Stirrup w/ 135° Hooks @Top Diaph. Diaphragm Reqs. Requirements +�+ N <br /> ol w w O O Stud, Typ. Stagger Adj. Class A Splices Ld Dif. Different Ret. Retain(ing) SOILS VALUES (Table 1806.2) Cl) <br /> 5/8" 5/8" 2Ld Min., or Use Class B* Splices Dim. Dimension RJ Roof Joist <br /> Bearing Pressure 1500 psf ♦, <br /> NAIL SPLICE <br /> MULTI-PLY BEAM SCREW SPACING Dist. Distance RR Roof Rafter <br /> � X X Min. Min. Concrete ONLY DJ Deck Joist RW Redwood M a) <br /> �? o �? o (A) " Min. Btwn. DL Dead Load SAD See Arch Dwg's <br /> `^� w 6" Min. End CONCRETE MASONRYIt <br /> Strap ES Break in TP Distance Fasteners Dwg. Drawing Sched. Schedule CA <br /> 2x4- MSTA24 (2) 16d @ 16" oc 1-7/16" Min. Bar Length of Lap, Ld Embed. of Bar Length of Embed. of (E) Existing Sgl. Single V <br /> 2x6- MSTA36 o o Edge Dist. Size Class A Class B Hook, L Size Lap, Ld Hook, L Ea. Each Sht Sheathing <br /> 0.4w 0.25w O do p do g. glot <br /> Max. Max. ° ° c 4" Min. Btwn. #3 16" 21" 7" #3 15" 5" EF Each Face Sim. Similar WIND DESIGN BASIS Q <br /> ° - 5/8 Min. EFP Equivalent Fluid SIP Str. Insulated Panel Ultimate Wind Speed, V 110 mph <br /> ° rn Non-Staggered #4 22" 28" 9" #4 26" 7" p uLr p <br /> Stagger o Rows gg Pressure SM Sheet Metal Nominal Wind Speed, VASD 85 mph <br /> in #5 27" 35" 11" #5 40" 9" Elev. Elevator, Elevation SMS Sheet Metal Screw <br /> Risk Category II <br /> 0 o Embed.Embed(ed), (ment) SOG Slab on Grade g Y <br /> Non-BearingBearing &/or Non-Bearing Bearing &/or #6 32" 42" 14" #6 74" 10" Exposure B <br /> 9 9 9 A-W B-W C-W Engr. Engineer Spec. Specifi(ed), (cations) <br /> Interior Wall Exterior Wall Interior Wall Exterior Wall #7 38" 49" 16" #7 101" 12" Importance Factor, IW 1.00 <br /> STRAP SPLICE Nominal Screw Length Allowable Load (Lbs)@ 12"o.c. (2 Rows) FOR Engineer ui Record Std. Standard <br /> #8 43 56" 18" #8 131 13 Eq. Equal, Equivalent Stl. Steel <br /> A-W 3-3/8" 1600(Either Side) ES Each Side Struc. Structure, (al) <br /> B-W 5" 1200(Head Side)/900(Point Side) EW Each Way SW Shear Wall SEISMIC DESIGN BASIS <br /> TYPICAL SHEAR WALL FRAMING NOTES: O TYPICAL SHEAR WALL FRAMING C-W 6-3/4" 1065(Head Side)/800(Point Side) Exp. Expand, Expansion Sym. Symmet(ry), (rical) <br /> (A) TYPICAL WOOD FRAMED OPENING Seismic Design Category D <br /> 1. Single sided shear walls may be placed on EITHER side of the framed wall. Ext. Exterior T&B Top and Bottom Site Class D <br /> 2. Sill plates on masonry or concrete to be pressure treated per Timber/ Lumber specifications. Sill plate thickness per SW Sched. Roof Frmg. per Plan Typ. Door Typ. Wndw. Fdn. Foundation T&G Tongue and Groove Seismic Factors <br /> 3. Wall studs and blk are required at all adjoining panel edges. Thickness of wall studs and blk at panel edges per SW Sched. FF Finished Floor Temp. Temporary <br /> 9• q 1 9 p 9 9• p 9 p SS/St 1.140/0.405 <br /> Cont. Dbl. 2x Top Roof Shtg. per Plan Dbl. TP per Specs. All Nailing to Conform FJ Floor Joist Thk. Thick ness <br /> 4. Where plywood is applied on both faces of a wall, edge nails shall be staggered on adjacent panel edges OR panel joints shall be Length of SW p p ( ) SDS/`SDI 0.912/0.512 <br /> Plate, Splice per w/the Governing Flr Floor in Thru Through <br /> offset to fall on different framing members. Plywood joint and sill plate nailing shall be staggered in all cases. per Plan Roof BN (g) ( g) Risk Category II <br /> 5. Plywood panels shall butt along centerlines of framing members. Minimum plywood dimension for shearwall shall be 12". 8/S-1.1 �� Building Code Table FOC Face of Concrete TN Toe-Nail Revision: <br /> ..... Solid Blkg. per Details 2304.10.1, Typ. FOM Face of Mason TP To Plate Importance Factor, le 1.00 <br /> 6. Nails shall be located at least 3/8"from all panel edges. Masonry p Resisting System: Wood Shear Walls <br /> 7. The use of nuematic nail guns for shear wall nailing is subject to continued satisfactory obsite performance and subject to the = = = FOS Face of Studs T-O Top of <br /> P 9 9 1 rY 1 P 1 Response Mod. <br /> review and approval b the Engineer of Record and/or Building Inspector. If the nail heads penetrate the outer I more than = _ _ = FOW Face of Wall TOB Top of Beam <br /> pp Y 9 g p p ply = _ _ Coefficient, R 6.5 <br /> SW BN Re d. SW BN to To PI. <br /> q @ <br /> p <br /> A35 Re d. To Frmg. Framing TOC To of Concrete <br /> would normal hand held hmmr, or minimum distances r notthe performance will m - - - - - - - - q @ p 9 9 p ou d be o a o a a d e d a e , o e u edge d s a ces are o a pe o ace be deemed - - - _ - _ _ <br /> Design Base Shear V 0.140W <br /> - Panel Edges & <br /> 9 <br /> 9 <br /> I <br /> Blk . to To PI. Shear <br /> of Dbl. Stud Ft. Foot Feet TOG To of Grade <br /> as unsatisfactoryand the continued use of pneumatic nail for shear wall nailing will not be permitted. - - - - - - - 9 p <br /> p 9 p g p Analysis Procedure: E v. Lateral Force <br /> - - - Entire Perim. of SW <br /> TransferH w. r W <br /> T . Ft . Footing TOM To of Mason <br /> d eS <br /> 8. At all bearingwalls both exterior and interior walls not noted as shear walls continuous full depth blocking shall be provided - - - - - Typ. 9 g p Masonry - -( ) p g p - - - - - _ _ _ _ _ _ _ _ = p (ASCE716,T. 12.61) <br /> Ga. Ga a Gau e TOS To of Steel <br /> - Sched. , <br /> between joists and rafters with LTP4 or A35 to to plates 32 oc at floors and 48 oc at roofs unless noted otherwise per Ian. „ 9 9 p <br /> - - - 12 oc Field Nailing Header per Plan <br /> 9 <br /> Galv. Galvanized TOW To of Wall <br /> 9. Refer to materials specifications for additional framing requirements. . . P <br /> p 9 q <br /> - - - - - - - - Re d. Int. of <br /> q @ <br /> - - - - - - - - - - - Upper sw per Plan H E ET INDEX <br /> - - - - - - - - - - - pp p GB Grade Beam TRU To Remain S <br /> Panel Use Dbl. King Stud GC General Contractor Unchanged <br /> Floor Sht per Plan g <br /> _ _ = 9 p „ <br /> > - <br /> - Sans 8 0 <br /> G Gypsum Trmr. Trimmer Stud <br /> HEAR WALL LEGEND ,S G <br /> ht . P Panel Y Y TYPICAL HEAR WALL INTERSECTIONS TI N - - - - - - - - s a e <br /> LY C S S C O S - - - <br /> g 11 - - - <br /> S-1.1 Structural Title Sheet <br /> = Sill PI. to Blk ./Rim <br /> UNO per Plan <br /> O - - Hldn. Holdown T Typical <br /> - - - g p Typ. Yp <br /> T INTERSECTION "T"INTERSECTION HD STRAP . Shear Transfer Hdw. S 1.2 Structural Specifications <br /> _ _ _ = Hdr. Header UNO Unless Noted p <br /> . Cont. Stud or Blk <br /> HD Strapfrom Abv. Alin 9. <br /> g <br /> TYPICAL OR WITH HD = per SW Sched. Hdw. Hardware Otherwise <br /> HD Strap & Post as <br /> Panel Ed es <br /> Use Dbl. Trmr. Stud <br /> p <br /> w/HD Post Blw. - - - <br /> @ 9 <br /> H r. Hanger Vert. Vertical <br /> 9 9 - <br /> I P Headers 6x10 S 2.1 Foundation and Floor Framing Plan <br /> Occurs per Ian - - - 'II I.- - - - - SW BN to Si P <br /> r W ,Frmg. e S @ P g <br /> 9 p <br /> - - - - - _ _ _ - - _ - - = Hor iz . Horizontal VIF Verify in Field <br /> - - 4 x12 or Larger, ( ) fY <br /> HD to Blw. - - - <br /> - - - Sched. 9 , - <br /> S 2.2 Roof Framing Plan <br /> - - - I g <br /> = _ = Floor BN Ht. Height VWA Verify with Arch <br /> UNO per Plan g <br /> SW Type, Refer to SW ID Inside Diameter w/ With <br /> Yp , Solid Blk . or Rim per <br /> Proj. Engr.: D. Shapiro <br /> PT Sill Plate Size g p <br /> In. Inch es w/n Within S 3.1 Structural Details <br /> Sched. for Sht Nailing, . _ _ Inch(es) <br /> 9•, 9, - - - - Details <br /> A35 Re d. Bot. <br /> 16d or SDS Tranfer q I @ <br /> Pro'. Mn r.. B. Hausmann <br /> - � per SW Sched. <br /> J 9- P- - - - - Ins Ins ect ion w/o Without <br /> AB s Transfer Hdw. Etc. SW BN T - .2 tr t r I D t it <br /> YP• <br /> P• p ( ) S3 S ucua eas <br /> v- . of Dbl. Kin Stud <br /> er SW Sched. - - 9 <br /> p SW BN to To P. <br /> - - p In Interior W W r w <br /> i <br /> t. S Wood Screw- - - Date: 9 Sept. 2022 Scale: NTS <br /> HD P r Plan T Post e a & <br /> Length f W Min. - - - - - - - - - <br /> p Typ_ <br /> t o S <br /> SW BN T - Inv. Invert Inverted Wndw. Window <br /> Yp <br /> - - - Blk . to To PI. Shear <br /> - - - - - - - - - - - - HD Sched. 9 p <br /> ¢ 16d or SDS TranferWeightAlpine En 2 e . Job No.: 2 053 <br /> Jst. Joist Wt. P 9 <br /> P - - - - - - Tr n f r H w. r W <br /> HD & Post as ase d e S <br /> HD Strapfrom Abv. NOT <br /> per SW Sched. <br /> - - P <br /> p = 0 K Kips 1 000 pounds) WWF Welded Wire Fabric <br /> _ _ _ _ - - _ - HD as Occurs per ill PI. r p , p <br /> Occurs er Plan - - - - - p Sched. S per Specs ( ) <br /> Cont. to Level Blw. Alin p <br /> g = _ _ Plan KLF Kips per Linear Ft. Yd. Yard <br /> Li Post Blw. to Match HD Post <br /> "L"INTERSECTION 2x4 WALLS "L"INTERSECTION 2x6 WALLS Lower SW per Plan King King Stud <br /> Abv. & BN per SW Type p - KP King Post @ At STRUCTURAL <br /> FORCOIlgcO HD to Blw. HD Strap & Post as HD Strap & Post as AB Size,Spacing, PT Sill Plate & Dbl. 2x Sill @ Wndw. KSF Kips per Square Ft. ° Degrees <br /> y O { Occurs per Plan ��Occurs per Plan and PI. Washer per Anchorage per Specs. Recommended Non-Str. Int.Wall Hdr. Opng, KSI Kips per Square In. > Greater Than TITLE SHEET <br /> & SW Sched. Lb(s). Pound(s) < Less Than <br /> SW Sched. San 2x4 Wall 2x6 Wall <br /> ans for Specific Transfer& p LL Live Load # Number, Pound(s) <br /> Retighten AB s Prior <br /> Detail at each Shear Wall Location HD Anchor per HD <4'-0" Dbl. 2x4 Flat Dbl. 2x6 Flat Loc. Location / Per <br /> Sched. _ to Closing in Hdw. LW Light Weight % Percent(age) <br /> �4 ��' o� ® 16d or SDS Tranfer — < 6'-0" 4x4 4x6 Flat ± <br /> COR �` per SW Sched. ® 16d or SDS Tr <br /> r IIII= Plus or Minus <br /> o Ln <br /> e <br /> N�r s SW BN, Typ. per SW Sched. < 8'-0" 4x6 6x6 � <br /> N o SW BN, Typ. Span in Feet Equals Beam <br /> a� HD & Post per Plan > 8'-0" p <br /> De th in Inches <br /> a)InHD & Post per Plan SHEAR WALL ELEVATION SHEAR WALL SECTION <br /> (n N DO NOT SCALE THESE DRAWINGS. Refer to Architectural plans for all dimensions. <br />