My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit File BLD-2021-0767 2617 Washington Boulevard (12)
>
BUILDING CONSTRUCTION AND MODIFICATION PERMIT FILES (VALID)
>
Active
>
2617 Washington Boulevard
>
Permit File BLD-2021-0767 2617 Washington Boulevard (12)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2022 9:24:16 AM
Creation date
9/21/2022 9:20:19 AM
Metadata
Fields
Template:
PL_PermitFile
Street Name
Washington Boulevard
Street Number
2617
Parcel
P117635
P117635
Permit Number
BLD-2021-0767
Address
2617 Washington Boulevard
Comments
Approved plans that were revised
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Underwood. & Associates <br />November 22, 2021 <br />City of Anacortes <br />Planning, Community, & Economic Development <br />904 6th Street <br />Anacortes, WA 98221 <br />Attn: Rob Frisinger, Plans Examiner <br />BP Reference: 2617 Washington Boulevard, Yelle Family Residence Comments Response <br />Dear Rob, <br />Below are copies of your comments regarding the building review and my responses that follow each <br />item. <br />1. Trap primer required for floor drain. <br />a. RESPONSE: Please see revised floor drain note to include call out for trap primer <br />on sheet A3.1. <br />2. Please verify that braced wall panels conform with the requirements of R3O1.2.2.6 (3). <br />Revise as necessary. <br />a. RESPONSE: Please see revised sheet A2.3; added shear blocking between floor <br />joists. Please see revised first floor lateral plan lengthening the shear call out to <br />the edge of the opening. Please see sheet A4.1 for added header across opening. <br />This is revised per R3O1.2.2.6 (3) that allows for shear wall offsets in plane. <br />3. 5,798 fire area, 2,000 gpm, double hydrant flow test required. Fire flow report required <br />prior to issuing permit: <br />a. RESPONSE: Commercial Fire Protection will be on site to test the hydrants closest <br />to the site on December 1st. I will forward that report when received. <br />4. Completed storm water application required. <br />a. RESPONSE: Please see attached. <br />5. Only one vehicle access point is allowed per lot. <br />a. RESPONSE: Site plan has been updated to remove existing driveway curb and <br />replace with curb/gutter. Please see revised site plan sheet. <br />If you have any questions, comments, or concerns please don't hesitate to contact me. <br />Sincerely, <br />JEREMY MCNETT <br />ARCHITECT <br />1005 4ch Street Anacortes, WA 98221 . 360-840-3294 <br />
The URL can be used to link to this page
Your browser does not support the video tag.