Laserfiche WebLink
�;;;00 <br />Shed Roof <br />Construction <br />30 YEAR COMPOSITION ROOFING OVER 15# <br />ROOFING PAPER OVER 7/16 EXTERIOR <br />ROOF SHEATHING OVER ENGINEERED <br />ROOF TRUSS OR 2X12 ROOF RAFTERS 16" <br />O.C. W/ R-49 BATT INSULATION INTERIOR <br />5/8" TYPE"X" GYP.BOARD TAPE AND SEAL <br />PRIME AND PAINT OR 3/4" T&G INTERIOR <br />DECKING PER OWNER SELECTION VENT <br />ROOF ASSEMBLY FROM SOFFIT WITH MIN 1" <br />_ AIRSPACE <br />DOUBLE 2X8 HEADER AT ALL DOOR <br />AND WINDOW OPENINGS WEATHER <br />SEAL ALL OPENINGS PRIOR TO <br />INSTALLATION WITH WATERPROOF <br />TAPE AND CAULK ALL WINDOWS <br />AND DOORS AT INSTALLATION PER <br />MANUFACTURERS SPECIFICATIONS <br />L <br />Typ. Exterior Wall - <br />Construction <br />PAINTED HARDIE BOARD LAP SIDING <br />OVER TYVEK BUILDING WRAP OVER <br />7/16" EXTERIOR SHEATHING OVER 2X6 <br />FRAME WALLS AT 16" O.C. W/ R-21 <br />BATT INSULATION 1/2" TYPE "X" GYP. <br />BOARD INTERIOR FINISH TAPE AND <br />SEAL PRIME PAINT TO OWNERS <br />SELECTION <br />MA. E <br />00M <br />Deck over <br />conditioned <br />POLYUREA OR SIMILAR WATERPROOF <br />MEMBRANE OVER 3/4" EXT.GRADE <br />PLYWOOD OVER 2X DECK FRAMING RUN <br />MEMBRANE VERTICALLY UP SIDE <br />OF ELEVATION MIN. 12" AND LAP <br />00 010 "10 <br />EDGE MIN. 6" AT EDGE <br />Typ. Floor <br />Construction <br />FIN. FLOOR MATERIAL OVER 3/4" <br />T&G PLYWD. OVER 11-7/8"TJI <br />360 /W PRE MANUFATURED <br />KNOCKOUTS FOR MECH/ELECT. <br />W/ R38 BATT INSULATION <br />UNVENTED RAFTER BAYS TO COMPLY WITH IRC R806.5 <br />WHERE ONLY AIR -IMPERMEABLE INSULATION IS <br />PROVIDED, IT SHALL BE APPLIED IN DIRECT CONTACT <br />WITH THE UNDERSIDE OF THE STRUCTURAL ROOF <br />SHEATHING. <br />Jk. <br />WHERE AIR -PERMEABLE INSULATION IS INSTALLED <br />DIRECTLY BELOW THE STRUCTURAL SHEATHING, <br />.'' <br />RIGID BOARD OR SHEET INSULATION SHALL BE <br />,•>> <br />INSTALLED <br />DIRECTLY ABOVE THE ROOF SHEATHING IN <br />ACCORDANCE WITH THE R-VALUES IN TABLE R806.5 <br />FOR CONDENSATION CONTROL. <br />Typ. Exterior Wall <br />Construction <br />PAINTED HARDIE BOARD LAP SIDING <br />OVER TYVEK BUILDING WRAP OVER <br />7/16" EXTERIOR SHEATHING OVER 2X6 <br />FRAME WALLS AT 16" O.C. W/ R-21 <br />BATT INSULATION 1/2" TYPE "X" GYP. <br />BOARD INTERIOR FINISH TAPE AND <br />SEAL PRIME PAINT TO OWNERS <br />SELECTION <br />Conc. Floor <br />Construction <br />4" THICK CONC. SLAB SLOPE TO <br />DOORWAY OVER WIRE MESH <br />REINFORCING OVER UNDERSLAB <br />WATERPROOF MEMBRANE <br />OVER 20 MIL VAPOR BARRIER <br />OVER 12" CLEAN DRAIN ROCK <br />OVER COMPACTED SOIL FINISH <br />AND SEAL TO OWNERS <br />SPECIFICATIONS <br />ENLARGED WALL SECTION <br />NTS <br />FINISH GRADE <br />FINISH GRADE <br />A2.2 <br />�-- � - ENLARGED <br />�` WALL SECTION <br />3 I I <br />I <br />AT4 I I <br />I I <br />I <br />I I <br />I ' I <br />I I <br />I I <br />I I <br />I I <br />2 I FA2.5 MINI -SPLIT-> <br />I 11 WALL LOCATION <br />I I <br />I I <br />DECK MA ER BE <br />I I <br />I I <br />I I <br />I I <br />I I <br />I 1 I <br />A2.5 <br />Shed Roof <br />Construction <br />30 YEAR COMPOSITION ROOFING OVER 15# <br />ROOFING PAPER OVER 7/16 EXTERIOR <br />ROOF SHEATHING OVER ENGINEERED <br />ROOF TRUSS OR 2X12 ROOF RAFTERS W/ <br />R-49 BATT INSULATION <br />3 <br />A2.4 <br />SIM. <br />Typ. Floor <br />Construction <br />M.BATH FIN. FLOOR MATERIAL OVER 3/4" <br />T&G PLYWD. OVER 11-7/8"TJI <br />360 /W PRE MANUFATURED <br />KNOCKOUTS FOR MECH/ELECT. <br />T; W/ R38 BATT INSULATION <br />O <br />I I <br />I I <br />�I <br />I I <br />I I <br />I I 3 <br />I I A2.2 <br />SHOP <br />I I <br />I i I <br />I I <br />GARAGE <br />I I <br />I � •I <br />I I <br />1 1 <br />---------- <br />EXISTIN NO CHANGE 1 0 <br />EXISTING WAL <br />EXISTING NO CHANGE <br />SECTION <br />1/4" = V-0" <br />Shed Roof <br />Construction <br />30 YEAR COMPOSITION ROOFING OVER 15# <br />ROOFING PAPER OVER 7/16 EXTERIOR <br />ROOF SHEATHING OVER ENGINEERED <br />ROOF TRUSS OR 2X12 ROOF RAFTERS W/ <br />R-49 BATT INSULATION <br />1 <br />A2.2 <br />CLOSET <br />GARAGE <br />CONC. STEMWALL <br />MASTER <br />A2.1 <br />SECTION <br />1/4" = V-0" <br />3 <br />4..A <br />MAIN FLOOR LEVEL <br />00 <br />FINISH GRADE <br />GAR. FLOOR LEVEL <br />1 <br />A2.4 <br />l <br />BUILDING SECTION GENERAL NOTES <br />1. VERIFY ALL SOILS PREPARATION PRIOR TO CONSTRUCTION. <br />2. BUILDING PADS SHALL BE GRADED 2% TOWARD APPROVED <br />DRAINAGE FACILITIES AND PROVISIONS SHALL BE MADE TO <br />CONTROL AND DRAIN SURFACE WATER AROUND BUILDING. <br />3. FOUNDATION GRADE OR PRESSURE TREATED MUDSILL <br />REQUIRED. COLUMNS OR POSTS LOCATED ON CONCRETE OR <br />MASONRY FLOORS AND THAT SUPPORT PERMANENT <br />STRUCTURES SHALL BE SUPPORTED BY CONCRETE PIERS OR <br />METAL PEDESTALS PROJECTING ABOVE EXPOSED EARTH A <br />MINIMUM OF 6" AND AT LEAST 1" ABOVE SUCH FLOORS UNLESS <br />TREATED WOOD IS USED. INDIVIDUAL CONCRETE OR MASONRY <br />PIERS SHALL PROJECT AT LEAST 8" ABOVE EXPOSED GROUND <br />UNLESS THE COLUMNS OR POSTS THAT THEY SUPPORT ARE OF <br />WOOD RESISTANT TO DECAY. <br />4. MINIMUM CLEARANCE FROM GROUND UNDER GIRDERS SHALL BE <br />12 INCHES; UNDER JOISTS SHALL BE 18 INCHES. <br />5. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE - <br />PERMEABLE FLOORS THAT ARE EXPOSED TO THE WEATHER, <br />SUCH AS CONCRETE OR MASONRY SLABS SHALL BE APPROVED <br />WOOD OF NATURAL RESISTANCE TO DECAY OR TREATED WOOD <br />UNLESS SEPARATED FROM SUCH FLOORS BY AN IMPERVIOUS <br />MOISTURE BARRIER. <br />6. ALL ENCLOSED ROOF AREAS SHALL BE VENTED TO PREVENT THE <br />ACCUMULATION OF CONDENSATION. A MINIMUM 1" AIR SPACE <br />SHALL BE MAINTAINED BETWEEN THE TOP OF THE INSULATION <br />AND THE ROOF DECKING. A CONTINUOUS BAFFLED ABS ROOF <br />VENT SHALL BE INSTALLED ALONG THE RIDGE AND AT ROOF TO <br />WALL LOCATIONS WHERE SHED ROOFS CANNOT VENT TO THE <br />RIDGE. ALL VENTS INSTALLED IN EAVES SHALL BE TESTED, <br />RATED AND APPROVED BY THE STATE FIRE MARSHAL FOR <br />INSTALLTION IN THE SOFFIT. ALL VENTS INSTALL IN SOFFITS <br />SHALL HAVE A GALV. METAL INSECT SCREEN WITH OPENINGS NO <br />GRATER THAN 1/8" SQUARE <br />7. FOR ROOF AREAS THAT CAN NOT BE VENTED DUE TO FRAMING <br />CONDITIONS, THE FOLLOWING METHOD SHALL BE USED: <br />8. ALL ENCLOSED ROOF AREAS SHALL BE INSULATED WITH BASF <br />COMFORT FOAM 178 SPRAYED TO UNDERSIDE OF ROOF <br />SHEATHING WITH NO AIR VOIDS TO ALLOW FOR AN UNVENTED <br />ROOF SYSTEM THAT DOES NOT ALLOW FOR CONDENSATION TO <br />FORM. MANUFACTURER'S INSTALLATION METHODS MUST BE <br />ADHERED TO IN EVERY ASPECT OF THE INSTALLATION. <br />A. FOR TRUSSED ROOF APPLICATIONS: <br />THE SPRAY APPLIED INSULATION WILL BE APPLIED BY <br />INSTALLERS CERTIFIED BY BASF POLYURETHANE FOAM <br />ENTERPRISES. COMFORT FOAM 178 APPLIED TO THE UNDERSIDE <br />OF THE ROOF SHEATHING SPRAYED TO 6-1/2 " TO ACHIEVE AN R- <br />VALUE OF R-39. ENTRY TO THE ATTIC IS LIMITED TO SERVICE OF <br />UTILITIES AND THERE ARE NO HEAT PRODUCING APPLIANCES IN <br />THIS SPACE, THEREFORE IGNITION BARRIER IS NOT REQUIRED. <br />AIR IN ATTIC SHALL NOT CIRCULATE TO OTHER PARTS OF THE <br />BUILDING. THE THERMAL BARRIER IS 5/8" TYPE X DRYWALL <br />APPLIED TO THE BOTTOM CHORD OF THE ROOF TRUSS. IT IS <br />INSTALLED IN A MANNER SO THAT THE FOAM PLASTIC <br />INSULATION IS NOT EXPOSED TO THE INTERIOR. <br />B. FOR RAFTER FRAMED ROOF APPLICATIONS: <br />THE SPRAY APPLIED INSULATION WILL BE APPLIED BY <br />INSTALLERS CERTIFIED BY BASF POLYURETHANE FOAM <br />ENTERPRISES. COMFORT FOAM 178 APPLIED TO TEH UNDERSIDE <br />OF THE ROOF SHEATHING SPRAYED TO 3-1/2 " TO ACHIEVE AN R- <br />VALUE OF R-21. R-19 UNFACED BATTS WILL BE APPLIED DIRECTLY <br />BENEATH THE COMFORT FOAM 178 TO ACHIEVE A TOTAL R-VALUE <br />OF R-40. THE THERMAL BARRIER IS 5/8" TYPE X DRYWALL <br />INSTALLED IN A MANNER SO THAT THE FOAM PLASTIC <br />INSULATION IS NOT EXPOSED TO THE INTERIOR. <br />9. UNDERFLOOR VENTS SHALL EQUAL 1 SQUARE FOOT FOR EACH <br />150 SQUARE FEET OF UNDERFLOOR AREA, AND MUST PROVIDE <br />CROSS VENTILATION. OPENINGS MUST BE COVERED WITH A <br />PROTECTIVE NON CORROSIVE MESH WITH NO OPENINGS <br />EXCEEDING 1/8" <br />10. OPENINGS EXTENDING VERTICALLY THROUGH FLOORS SHALL <br />BE ENCLOSED IN A SHAFT OF FIRE -RESISTIVE <br />CONSTRUCTION. CHUTES AND SHAFTS WITH A CROSS - <br />SECTIONAL AREA OF NOT MORE THAN 9 SQUARE FEET MAY <br />BE EITHER OF APPROVED FIRE -RESISTIVE WALL <br />CONSTRUCTION OR MAY HAVE THE INSIDE LAYERS OF THE <br />ASSEMBLY REPLACED BY A LINING OF NOT LESS THAN 26 <br />GAUGE GALVANIZED SHEET METAL WITH JOINTS <br />LOCKLAPPED. OPENINGS SHALL BE PROTECTED WITH A 1 3/8" <br />SOLID WOOD DOOR. <br />11. FOUNDATION SUPPORT REQUIRED FOR EXTERIOR ROCK <br />VENEER. ANCHOR TIES SHALL BE PROVIDED TO HORIZONTAL <br />T Floor JOINT REINFORCEMENT WIRE OF N0. 9 GAUGE OR <br />yp• EQUIVALENT. DETAIL REQUIRED FOUNDATION SUPPORT <br />Construction 12. NO VENTS SHALL BE INSTALLED IN THE EAVES OR CORNICES - <br />FIN. FLOOR MATERIAL OVER 3/4" <br />00 T&G PLYWD. OVER 11-7/8"TJI 13. EAVES AND SOFFITS SHALL BE PROTECTED WITH IGNITIION <br />360 /W PRE MANUFATURED RESISTANT MATERIAL. <br />KNOCKOUTS FOR MECH/ELECT. <br />W/ R38 BATT INSULATION 14. ALL EXTERIOR WALL COVERINGS SHALL BE APPROVED <br />NON- COMBUSTIBLE OR IGINITION RESISTANT MATERIALS. <br />00 <br />MAIN FLOOR LEVEL <br />CONC. RET. WALL <br />GAR. FLOOR LEVEL <br />- 2 <br />A2.1 SIM. <br />15. ALL EXTERIOR GLAZING SHALL BE INSULATED WITH AT LEAST <br />ONE PANE TEMPERED. FOR SIMPLICITY, ALL EXTERIOR <br />GLAZING, BOTH PANES ON THIS PROJECT ARE TO BE <br />TEMPERED. <br />16. EXTERIOR DOOR ASSEMBLIES SHALL HAVE STILES AND RAILS <br />THAT ARE 1- 3/4" THICK AND A FIELD PANEL THICKNESS OF 1- <br />1/2 " MINIMUM. <br />17. EXTERIOR DECKING SURFACES, STAIR TREADS, RISERS AND <br />LANDINGS OF DECKS WHERE ANY PORTION OF THE DECK IS <br />WITHIN 10 FEET OF THE PRIMARY STRUCTURE SHALL BE <br />CONSTRUCTED OF IGNITIION RESISTANT MATERIAL OR HEAVY <br />TIMBER. <br />18. ALL FOUNDATION WALLS ADJACENT TO PATIO AREAS AND/OR <br />RETAIN EARTH AT CRAWLS SPACES SHALL BE <br />WATERPROOFED WITH A SELF -ADHERED WATERPROOFING <br />FINISH MEMBRANE SYSTEM INSTALLED PER MANUFACTURER'S <br />GRADE REQUIREMENTS. AT ALL DOOR AND WINDOW OPENINGS THAT <br />ARE FLUSH TO FLOOR FINISH, IN ADDITION TO THE <br />WATERPROOFING MEMBRANE, GALV. MTL FLASHING SHALL <br />ALSO BE INSTALLED AND CARRIED DOWN 12" BELOW <br />RETAINED EDGE. <br />19. PROVIDE SILL PLATE SEAL AT ALL EXTERIOR WALLS BETWEEN <br />THE FOUNDATION AND P.T. SILL - PROTECTO WRAP PW 100 / <br />40 BUTYL OR EQUAL <br />N <br />� <br />U <br />. <br />M <br />O <br />U <br />fu <br />O <br />L <br />M <br />a..r <br />N <br />3: <br />O <br />M <br />C <br />fa <br />Q <br />� <br />C�2 <br />dp <br />� <br />fo <br />a)& <br />1 <br />N <br />d' <br />OU <br />� <br />.V) <br />V) <br />cn <br />U <br />M <br />ra <br />a)O <br />a)- <br />E <br />Ln <br />C <br />j- <br />O <br />Y CN <br />U co <br />0 <br />(M <br />X CN U <br />� C:) � <br />Q N Q <br />Document Date: <br />Document Phase: <br />Construction Documents <br />rev. date remark <br />Building <br />Sections A,B <br />A3.3 <br />The use of these plans and specifications is restricted to the original site for which they were prepared. Re -use, reproduction or publication by any method <br />in whole or in part is prohibited, unless authorized by Michael Trafton. Ownership of the design, plans and specifications is solely with Michael Trafton. <br />