Loading...
HomeMy WebLinkAboutPermit File BLD-2022-0276 1310 15th Street • ''. City of Anacortes Invoice/Permit#: BLD-2022-0276 \ 904 6th Street Applied date: 04/18/2022 `70 P.O.Box 547 Issue date: 04/18/2022 Anacortes, WA 98221-0547 Expire date: 10/15/2023 ,Q1I J 1-z (360) 293-1901 Job Address: 1310 15TH ST Permit Type: Mechanical Permit ANACORTES WA 98221-2213 Project: APN: P55580 Remarks: Install a ductless heat pump, 3 zones. Owner: RICCARDI JAMES A Contractor: MARSHALLS MECHANICAL LLC Address: PO BOX 1573 Address: 142 HARRINGTON RD ANACORTES WA 98221-6573 COUPEVILLE WA 98239 Phone: Phone: (360)678-5402 License#: General Information: Fees: #of Heat Pumps<=3 Hp 3 Mechanical Permit Fees 67.60 Total Calculated: 67.60 Deposits/Receipts: 0.00 Total Due: 67.60 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order, proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and e this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUE Y y ,o PLANNING, COMMUNITY,&ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547,Anacortes, WA 98221 4'P Office Location: 904 6th Street, Anacortes WA 98821 a �cc - Phone: (360) 293-1901 PLUMBING & MECHANICAL PERMIT APPLICATION Please complete all applicable information and submit to buildin;;permit@cityofanacortes.orK PROPERTY INFORMATION PROJECT ADDRESS ASSESSORS PARCEL NUMBER 1310 15th street 3772-093-017-0006 PROJECT VALUATION 13,700.00 Ei RESIDENTIAL El COMMERCIAL PROPERTY OWNER OWNER PHONE JIM RICCARDI 3608091196 OWNER ADDRESS OWNER EMAIL PO BOX 1573, ANACORTES WA 98221 jimriccardi47@gmail.com APPLICANT INFORMATION El PROPERTY OWNER CONTRACTOR OTHER: NAME PHONE GREG MARSHALL 3606785402 ADDRESS EMAIL 142 HARRINGTON ROAD, COUPEVILLE WA 98239 marshallsmechanical@comcast.net CONTRACTOR INFORMATION NAME PHONE MARSHALLS MECHANICAL INC 3606785402 CONTRACTOR'S BUSINESS LICENSES* STATE LICENSE# EXPIRATION *All Contractors & Subcontractors must have a valid MARS H M I813J H 04/23 City of Anacortes business license prior to doing work UBI LICENSE# EXPIRATION in the city. 602 653 746 09/03/22 ADDRESS(STREET,CITY,STATE,ZIP) EMAIL 142 HARRINGTON ROAD, COUPEVILLE, WA 98239 marshallsmechanical@comcast.net PROJECT INFORMATION DESCRIPTION OF PROPOSED WORK: Install Ductless Heat Pump IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? r YES X NO If YES,provide the permit/application number: Plumbing/Mechanical Permit Application Updated December 2021 Page 1 of 3 MECHANICAL APPLIANCE/EQUIPMENT INFORMATION(NEW AND RELOCATED) EQUIPMENT TYPE Indicate the number of fixtures for each equipment type TOTAL GAS ELECTRIC OTHER-Please specify COMMENT Furnace Wall Heater Water Heater Heat Pump 3 zone ductless heat pump 3 Air Conditioner/Handler Radiant/Hydronic Heating Exhaust Fans Range Hood Fireplace Clothes Dryer&Duct Stove/Range/Oven Refrigeration Unit Gas Piping/Outlet(s) Boiler BTUs: Other TOTAL MECHANICAL OUTLETS PLUMBING FIXTURES FIXTURE TYPE(NEW AND RELOCATED) TOTAL FIXTURE TYPE(NEW AND RELOCATED) TOTAL Toilets Refrigerator water supply Kitchen Sink Pressure Reduction Valve/Regulator Utility Sink Water Service Line Tub Water Piping Hand Sink Washing Machine Shower Electric Water Heater:Tank-less? Yes❑ No Dishwasher Backflow Prevention Device Urinal Hose Bib Floor Drain/Floor Sink Drinking Fountain Hydronic Heat in:OFloor OWall Grease Interceptor Other-please specify: TOTAL PLUMBING FIXTURES Plumbing/Mechanical Permit Application Updated December 2021 Page 2 of 3 PLUMBING & MECHANICAL PERMIT APPLICATION CHECKLIST COMMERCIAL RESIDENTIAL 3 .o O SUBMITTAL REQUIREMENTS 2 C rri C 2 z W z m D "A Z P- 0 g G) m Plumbing&Mechanical Permit Application ✓ ✓ ✓ ✓ Mechanical Plans ✓ Structural Calculations ✓ State Non-Residential Energy Code Compliance Form ✓ Manufacturer's Specifications/Cut Sheets ✓ ✓ ✓ Plumbing Plans I Listed&Tested Fire Stopping Assemblies I Elevation View for Roof Mounted Equipment ✓ ✓ Existing Floor Plan ✓ I I I New Floor Plan ✓ I I I NOTE: 1. Handouts and standard details may be found on the City's Planning, Community, & Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, &reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. If installing a backflow prevention device, it will need to pass test results of which will need to be submitted to the city for review. ACKNOWLEDGEMENTS & SIGNATURE By affixing my signature hereto,I certify that I am the owner,or am acting as the Owner's authorized agent, and that the application and documents contained with this submittal are complete and accurate�to the best of my knowlleedgeeaandnd abilities. ���'% `//��a-/..t. 4/18/2022 SIGNAT� DATE Plumbing/Mechanical Permit Application Updated December 2021 Page 3 of 3 Job Name: Tag# rDAIKIN Submittal Data Sheet 3MXS24RMVJU 3 Port, 2-Ton Outdoor Heat Pump tr. Efficiency SEER EER HSPF COP e-i- - - - - 1.-7„." DAIKIN _ Non-Ducted 18 12.7 12.5 3.53 ---=---= f Ducted 14 9.7 8.2 3.44 Mixed 15.95 11.2 10.35 3.49 :--,�� Performance =��_.______—s' Cooling(Btu/hr) —,—.-- � Rated 24,000 -, Operating Range 14°F-115°F Rated Cooling Conditions: Indoor:80°F DB/67°F WB Outdoor:95°F DB/75°F WB e, f Heating(Btu/hr) t r Rated 24,000 pi=1z r:J Operating Range 5°F-60°F j 11 f I P E) Rated Heating Conditions: Indoor:70°F DB/60°F WB Outdoor:47°F DB/43°F WB `',iA RR A N-r NEP Complete warranty details available from your local dealer or at Electrical www.daikincomfort.com.To receive the 12-Year Parts Limited 208/60/1 230/60/1 Warranty,online registration must be completed within 60 days of System MCA 21.9 21.9 installation.Online registration is not required in California or Quebec. System MFA 25 25 If product is installed in a commercial application,limited warranty Compressor RLA 15.5 15.5 period is 5 years. Outdoor fan motor FLA .25 25 Outdoor fan motor W 73 73 Outdoor Specifications MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) Compressor Hermetically Sealed Swing Type RLA:Rated load amps(A) W:Fan motor rated output(W) Refrigerant R-410A Factory Charge(Lbs) 6.17 Refrigerant Oil PVE(FVCSOK) Cooling Heating Piping Liquid(in) %x 3 H 2,094 H 2,094 Airflow Rate(cfm) Gas(in) 3/8 x 1, M 2,094 M 1,981 %2 x 2 Drain(in) 11/16 1,981 L 1,119 Max.Interunit Piping Length(ft) 230 Sound Power Level(dBA) 52/54 Max.Interunit Height Difference(ft) 49.25 Dimensions(H x W x D)(in) 28-15/16 X 34-1/4 x 12-5/8 Chargeless(ft) 131.6 Weight(Lbs) 137 Additional Charge of Refrigerant(oz/ft) .21 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:December 2019 Page 1 of 7 a oa L N . 3 e0 ✓ a -c H co m U HANDLE 9/16{14} 34 1/4(870) _I 3-9/16(90) WIRING 114(7) 12-5/8(320) 1-3/16{30) '7ERCONNECTINGPIPING OUTDOOR AIR THERMISTOR •c Q • a. L BRAND NAME PLATE 1 E „ ,_.. .___ ..._.._ r. ==,,,____,i,,_._ _-_._ _== _ _ f MANUFACTURERS �� I M T_==-, --______ LABEL _ NN _ — —_ _— _— / N •U II 7 C O \■ O Op• • I 1 — N b00 O U zi 4-HOLES FOR FOUNDATION BOLTS `^ O (MB OR M10) 23-5/8(600) 4 15/16(125) 14-1:2(368j m -a-ti , i,3-1/16(78} t o c CO' — a al 110 In Q. '•i z 1-=N LL O c coI O MINIMUM SPACE FOR AIR PASSAGE I c E a� i — p rn O(a z';r <ROOM A> WALL HEIGHT ON AIR OUTLET SIDE=LESS THAN 1200 ti 0 }r —i GAS PIPE y44,4•97.6,69 YWAW.viiri ti .OD CO V i_ {43/8(49.5)SINGLE UNION) rn - 3 LIQUID PIPE - - J c Q ^ '� 20 11/16(525) ($1/4(¢6.4)SINGLE UNION) y _ r rco DRAIN OUTLET <ROOM B> i oco • ,u m GAS PIPE i V °? v v o (I.D O(415.9)HOSE FOR CONNECTION b Q (�1/2(�12.7)SINGLE UNION) ; co E v c C WITHDRAINJOINT LIQUID PIPE 1-15/16(50) - m 1-15/16(50) )' s c O 4-GROUND TERMINALS ( 1/4(46.4)SINGLE UNION} �s, o�1 . go rpm' r GAS PIPE c tn. {�1/2(�12.7)SINGLE UNION) % YO C� LIQUID PIPE o E Q) _ III I (@1/4(46.4)SINGLE UNION) $ v 5iIII . el.1- b g o +Ic 'III■� Q 7 A� .- [LIQUID 41l4(46.4) 2-9I16(ss) 1111 A muII1i1uI a ' ;� _M ''3 v N 115l16(SO)co — a 6cO N SERVICE PORT/ LIQUID STOP VALVE ` T " ° E fGAS STOP VALVE v v �y IN CASE OF REMOVING STOP VALVE C.3D093198 LL COVER AND TERMINAL STRIP COVER 1-11/16(43) 11/16(18) c N Y (0 0 N s CO 7 n X o gg 5 G -• E C ) Q Ja Optional Accessories P, Included Part Number Description DACA-WB-3 Mounting Bracket KEH063A4E Drain Pan Heater 2/3/4MXS&2/3MXL KPW063B4 Air Adjustment Grille KKG063A42 Back protection wire net KKG063A43 Side protection wire net KPS063A41 Snow hood(intake side plate) KPS063A44 Snow hood(intake rear plate) KPS063A47 Snow hood(outlet) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:December 2019 Page 3 of 7 3MXS24RMVJU Capacity Tables 7e'rEIAIKIN1 Non- Ducted, 60 Hz, 208-230V Cooling Capacity of each indoor unit a Heating Capacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room Rating (min"'max) 07 7.60 - - 7.60 7.30-8.40 8.80 8.80 8.70-9.70 09 9.80 9.80 7.40-10.80 11.30 11.30 10.00-12.50 12 13.00 13.00 7.50-14.40 15.00 - - - 15.00 9.90-16.70 15 16.30 - 16.30 8.90-18.00 18.80 18.80 9.40-20.80 18 19.50 19.50 8.90-21.60 22.50 22.50 9.40-25.00 07+07 7.60 7.60 15.20 8.90-16.80 8.75 8.75 17.50 9.30-19.40 07+09 _ 7.69 9.61 17.30 8.90-19.20 8.89 11.11 20.00 9.20-22.20 07+12 7.31 12.79 20.10 9.00-22.80 8.25 14.45 22.70 9.10-26.60 07+15 6.31 15.79 22.10 10.00-26.40 6.69 16.71 23.40 8.70-31.30 07+18 6.00 18.00 24.00 10.10-30.00 6.00 18.00 24.00 8.70-36.00 09+09 9.75 9.75 19.50 9.00-21.60 11.25 11.25 22.50 9.10-25.00 09+12 8.92 12.48 21.40 9.10-25.20 9.63 13.48 23.10 9.00-29.70 09+15 7.80 15.60 - - 23.40 10.10-28.80 7.93 15.87 23.80 9.70-34.40 09+18 7.06 16.94 24.00 10.10-30.00 7.06 16.94 24.00 8.60-36.00 12+12 11.70 11.70 - - 23.40 9.20-28.80 11.90 11.90 - - 23.80 9.00-34.40 12+15 9.88 14.12 - - 24.00 10.20^'30.00 9.88 14.12 - - 24.00 8.60-36.00 12+18 8.84 15.16 - - 24.00 10.20^'30.00 8.84 15.16 24.00 8.60-36.00 15+15 12.00 12.00 24.00 10.80-30.00 12.00 12.00 24.00 8.40-36.00 15+18 10.91 13.09 24.00 10.80-30.00 10.91 13.09 24.00 8.40-36.00 18+18 12.00 12.00 - - 24.00 10.90-30.00 12.00 12.00 - 24.00 8.30-36.00 07+07+07 7.13 7.13 7.13 - 21.40 10.00-25.20 7.70 7.70 7.70 23.10 8.60-29.70 07+07+09 6.98 6.98 8.73 - 22.70 10.10-27.60 7.26 7.26 9.08 23.60 8.60-32.90 07+07+12 6.40 6.40 11.19 - 24.00 10.10-30.00 6.40 6.40 11.20 24.00 8.50-36.00 07+07+15 5.33 5.33 13.33 - 24.00 10.80-30.00 5.33 5.33 13.32 24.00 8.30-36.00 07+07+18 4.80 4.80 14.40 - 24.00 10.80 30.00 4.80 4.80 14.40 - 24.00 8.30-36.00 07+09+09 6.86 8.57 8.57 - 24.00 10.10^'30.00 6.85 8.57 8.57 - 24.00 8.50-36.00 07+09+12 6.00 7.50 10.49 - 24.00 10.20^'30.00 6.00 7.50 10.50 24.00 8.50-36.00 07+09+15 5.05 6.32 12.63 - 24.00 10.90^'30.00 5.05 6.32 12.63 - 24.00 8.30-36.00 07+09+18 4.57 5.71 13.71 - 24.00 10.90^'30.00 4.57 5.71 13.71 - 24.00 8.30-36.00 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:December 2019 Page 4 of 7 3MXS24RMVJU Capacity Tables DAIK/IV Cooling Capacity of each indoor unit Heating Capacity of each indoor unit al Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room 1 D room Rating (min^'max) 07+12+12 5.33 9.33 9.33 - 24.00 10.30-30.00 5.34 9.33 9.33 - 24.00 8.40-36.00 07+12+15 4.57 8.00 11.43 - 24.00 10.90"'30.00 4.57 8.00 11.42 24.00 8.30-36.00 07+12+18 4.17 7.30 12.52 - 24.00 10.90^'30.00 4.17 7.30 12.52 24.00 8.30-36.00 07+15+15 4.01 10.00 10.00 - 24.00 11.20^'30.00 3.99 10.00 10.00 - 24.00 8.20-36.00 09+09+09 8.00 8.00 8.00 - 24.00 10.20-30.00 8.00 8.00 8.00 - 24.00 8.50-36.00 09+09+12 7.06 7.06 9.89 - 24.00 10.30"'30.00 7.06 7.06 9.88 - 24.00 8.40-36.00 09+09+15 6.00 6.00 12.00 - 24.00 10.90"'30.00 6.00 6.00 11.99 - 24.00 8.30-36.00 09+09+18 5.45 5.45 13.10 - 24.00 10.90-30.00 5.45 5.45 13.08 - 24.00 8.30-36.00 09+12+12 6.32 8.84 8.84 - 24.00 10.30-30.00 6.31 8.84 8.84 - 24.00 8.40-36.00 09+12+15 5.45 7.64 10.91 - 24.00 10.90-30.00 5.45 7.64 10.91 - 24.00 8.20"'36.00 09+12+18 5.00 7.00 12.00 - 24.00 10.90-30.00 5.00 7.00 12.00 - 24.00 8.20"'36.00 09+15+15 4.80 9.60 9.60 - 24.00 11.20-30.00 _ 4.80 9.60 9.60 - 24.00 8.20^'36.00 12+12+12 8.00 8.00 8.00 - 24.00 10.40-30.00 8.00 8.00 8.00 - 24.00 8.40-36.00 12+12+15 7.00 7.00 10.01 - 24.00 11.00-30.00 7.00 7.00 10.00 - 24.00 8.20-36.00 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:December 2019 Page 5 of 7 3MXS24RMVJU Capacity Tables flDAIKI$ Ducted, 60 Hz, 208-230V Cooling Capacity of each indoor unit Heating Capacity of each indoor unit A Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room Rating (min"max) 7.1 7.1 7.30-7.10 7 8.3 8.3 9.00-9.70 09 9.1 9.1 7.30-9.60 10.7 10.7 10.40-12.50 12 12.1 - 12.1 7.30-12.10 14.3 14.3 10.40-16.70 15 14.8 - - - 14.8 8.10-15.40 16.6 - - 16.6 10.10-20.80 18 17.6 - 17.6 8.10-18.80 18.9 - 18.9 10.10-25.00 07+07 6.95 6.95 13.9 8.80-14.30 7.9 7.9 - 15.8 9.60-19.40 07+09 7.02 8.78 - - 15.8 8.80-16.60 7.73 9.67 - 17.4 9.60-22.20 07+12 6.73 11.77 - - 18.5 8.80-19.90 7.13 12.47 - - 19.6 9.60-25.90 07+15 6.09 15.21 - - 21.3 9.40-23.30 6.23 15.57 - - 21.8 9.40-28.40 07+18 6 18 - - 24 9.40-26.60 6 17.99 - - 24 9.40-31.00 09+09 8.8 8.8 - - 17.6 8.80-18.80 11.05 11.05 - - 22.1 9.60-25.00 09+12 8.45 11.84 - - 20.3 8.80-22.10 8.79 12.3 - - 21.1 9.60-27.60 09+15 7.7 15.4 - - 23.1 9.40-25.50 7.77 15.53 - - 23.3 9.40-30.10 09+18 - 7.06 16.94 - - 24 9.40-27.00 7.06 16.94 - - 24 9.40-32.00 12+12 11.55 11.55 - - 23.1 8.80-25.50 11.65 11.65 - - 23.3 9.60-30.10 12+15 9.88 14.12 - - 24 9.40-27.00 9.88 14.12 - 24 9.40-32.00 12+18 8.84 15.16 24 9.40-27.00 8.84 15.16 - 24 9.40-32.00 15+15 12 12 24 9.90-27.00 12 12 - 24 9.10-32.00 15+18 10.91 13.09 - - 24 9.90-27.00 10.91 13.09 - 24 9.10-32.00 18+18 12 12 - - 24 9.90-27.00 12 12 - - 24 9.10-32.00 07+07+07 6.77 6.77 6.77 - 20.3 9.90-22.10 7.03 7.03 7.03 - 21.1 9.00-27.60 07+07+09 6.83 6.83 8.54 - 22.2 9.90-24.40 6.92 6.92 8.65 22.5 9.00-29.30 07+07+12 6.4 6.4 11.19 - 24 9.90-26.60 6.4 6.4 11.19 24 9.00-31.10 07+07+15 5.33 5.33 13.33 - 24 10.40-26.70 5.33 5.33 13.32 24 8.80-31.40 07+07+18 4.8 4.8 14.4 - 24 10.40-26.90 4.8 4.8 14.4 24 8.80-31.60 07+09+09 6.86 8.57 8.57 - 24 9.90-26.60 6.86 8.57 8.57 24 9.00-31.00 07+09+12 6 7.5 10.5 - 24 9.90-26.70 6 7.5 10.5 24 9.00-31.30 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:December 2019 Page 6 of 7 3MXS24RMVJU Capacity Tables D41/KIN1 Cooling Capacity of each indoor unit Heati n Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room Rating (min^'max) 07+09+15 5.05 6.32 12.63 - 24 10.40-26.80 5.05 6.32 12.63 24 8.80-31.50 07+09+18 4.57 5.71 13.71 - 24 10.40-26.90 4.57 5.71 13.7 24 8.80-31.80 07+12+12 5.33 9.33 9.33 - 24 9.90-26.80 5.32 9.33 9.33 24 9.00-31.50 07+12+15 4.57 8 11.43 - 24 10.40-26.90 4.57 8 11.43 - 24 8.80-31.80 07+12+18 4.17 7.3 12.53 - 24 10.40-27.00 4.17 7.3 12.51 - 24 8.80-32.10 07+15+15 4.01 10 10 - 24 10.70-27.00 4 10 10 - 24 8.60-32.10 09+09+09 8 8 8 - 24 9.90-27.00 8 8 8 - 24 9.00-32.00 09+09+12 _ 7.06 7.06 9.88 - 24 9.90-27.00 7.06 7.06 9.87 - 24 9.00-32.00 09+09+15 6 6 12 - 24 10.40-27.00 6 6 12 - 24 8.80-32.00 09+09+18 5.45 5.45 13.1 - 24 10.40-27.00 5.45 5.45 13.09 - 24 8.80-32.00 09+12+12 6.32 8.84 8.84 - 24 9.90-27.00 6.33 8.84 8.84 - 24 9.00-32.00 09+12+15 5.45 7.64 10.91 - 24.00 10.40"'27.00 5.45 7.64 10.91 - 24 8.80-32.00 09+12+18 5.00 7.00 12.00 - 24.00 10.40^'27.00 5 7 12 24 8.80-32.30 09+15+15 4.80 9.60 9.60 - 24.00 10.70"'27.00 4.8 9.6 9.6 - 24 8.60-32.30 12+12+12 8.00 8.00 8.00 - 24.00 9.90"'27.00 8 8 8 - 24 9.00-32.00 12+12+15 7.00 7.00 10.00 - 24.00 10.40^'27.00 7 7 10 - 24 8.80-32.30 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:December 2019 Page 7 of 7