HomeMy WebLinkAboutPermit File BLD-2022-0276 1310 15th Street • ''. City of Anacortes Invoice/Permit#: BLD-2022-0276
\ 904 6th Street
Applied date: 04/18/2022
`70 P.O.Box 547
Issue date: 04/18/2022 Anacortes, WA 98221-0547 Expire date: 10/15/2023
,Q1I J 1-z (360) 293-1901
Job Address: 1310 15TH ST Permit Type: Mechanical Permit
ANACORTES WA 98221-2213 Project:
APN: P55580
Remarks: Install a ductless heat pump, 3 zones.
Owner: RICCARDI JAMES A Contractor: MARSHALLS MECHANICAL LLC
Address: PO BOX 1573 Address: 142 HARRINGTON RD
ANACORTES WA 98221-6573 COUPEVILLE WA 98239
Phone: Phone: (360)678-5402
License#:
General Information: Fees:
#of Heat Pumps<=3 Hp 3 Mechanical Permit Fees 67.60
Total Calculated: 67.60
Deposits/Receipts: 0.00
Total Due: 67.60
The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of
the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State.To the extent the issuance or
granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or
federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be
valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order, proclamation,guidance advice or decision of
the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,
inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or
decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is
suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and e this application and know the same to
be true and correct.
SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUE Y
y ,o PLANNING, COMMUNITY,&ECONOMIC DEVELOPMENT DEPARTMENT
Mailing Address: P.O. Box 547,Anacortes, WA 98221
4'P
Office Location: 904 6th Street, Anacortes WA 98821
a �cc - Phone: (360) 293-1901
PLUMBING & MECHANICAL PERMIT APPLICATION
Please complete all applicable information and submit to buildin;;permit@cityofanacortes.orK
PROPERTY INFORMATION
PROJECT ADDRESS ASSESSORS PARCEL NUMBER
1310 15th street 3772-093-017-0006
PROJECT VALUATION
13,700.00 Ei RESIDENTIAL El COMMERCIAL
PROPERTY OWNER OWNER PHONE
JIM RICCARDI 3608091196
OWNER ADDRESS OWNER EMAIL
PO BOX 1573, ANACORTES WA 98221 jimriccardi47@gmail.com
APPLICANT INFORMATION
El PROPERTY OWNER CONTRACTOR OTHER:
NAME PHONE
GREG MARSHALL 3606785402
ADDRESS EMAIL
142 HARRINGTON ROAD, COUPEVILLE WA 98239 marshallsmechanical@comcast.net
CONTRACTOR INFORMATION
NAME PHONE
MARSHALLS MECHANICAL INC 3606785402
CONTRACTOR'S BUSINESS LICENSES* STATE LICENSE# EXPIRATION
*All Contractors & Subcontractors must have a valid MARS H M I813J H 04/23
City of Anacortes business license prior to doing work UBI LICENSE# EXPIRATION
in the city. 602 653 746 09/03/22
ADDRESS(STREET,CITY,STATE,ZIP) EMAIL
142 HARRINGTON ROAD, COUPEVILLE, WA 98239 marshallsmechanical@comcast.net
PROJECT INFORMATION
DESCRIPTION OF PROPOSED WORK:
Install Ductless Heat Pump
IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? r YES X NO
If YES,provide the permit/application number:
Plumbing/Mechanical Permit Application
Updated December 2021 Page 1 of 3
MECHANICAL
APPLIANCE/EQUIPMENT INFORMATION(NEW AND RELOCATED)
EQUIPMENT TYPE Indicate the number of fixtures for each equipment type TOTAL
GAS ELECTRIC OTHER-Please specify COMMENT
Furnace
Wall Heater
Water Heater
Heat Pump 3 zone ductless heat pump 3
Air Conditioner/Handler
Radiant/Hydronic Heating
Exhaust Fans
Range Hood
Fireplace
Clothes Dryer&Duct
Stove/Range/Oven
Refrigeration Unit
Gas Piping/Outlet(s)
Boiler BTUs:
Other
TOTAL MECHANICAL OUTLETS
PLUMBING FIXTURES
FIXTURE TYPE(NEW AND RELOCATED) TOTAL FIXTURE TYPE(NEW AND RELOCATED) TOTAL
Toilets Refrigerator water supply
Kitchen Sink Pressure Reduction Valve/Regulator
Utility Sink Water Service Line
Tub Water Piping
Hand Sink Washing Machine
Shower Electric Water Heater:Tank-less? Yes❑ No
Dishwasher Backflow Prevention Device
Urinal Hose Bib
Floor Drain/Floor Sink Drinking Fountain
Hydronic Heat in:OFloor OWall Grease Interceptor
Other-please specify:
TOTAL PLUMBING FIXTURES
Plumbing/Mechanical Permit Application
Updated December 2021 Page 2 of 3
PLUMBING & MECHANICAL PERMIT APPLICATION CHECKLIST
COMMERCIAL RESIDENTIAL
3 .o
O SUBMITTAL REQUIREMENTS 2 C rri C
2 z W z m
D "A Z
P- 0 g G) m
Plumbing&Mechanical Permit Application ✓ ✓ ✓ ✓
Mechanical Plans ✓
Structural Calculations ✓
State Non-Residential Energy Code Compliance Form ✓
Manufacturer's Specifications/Cut Sheets ✓ ✓ ✓
Plumbing Plans I
Listed&Tested Fire Stopping Assemblies I
Elevation View for Roof Mounted Equipment ✓ ✓
Existing Floor Plan ✓ I I I
New Floor Plan ✓ I I I
NOTE:
1. Handouts and standard details may be found on the City's Planning, Community, & Economic
Development website or can be obtained at city hall during normal business hours.
2. Plans, calculation, &reports prepared by state licensed architects or professional engineers must
be stamped and signed by the design professional.
3. If installing a backflow prevention device, it will need to pass test results of which will need to be
submitted to the city for review.
ACKNOWLEDGEMENTS & SIGNATURE
By affixing my signature hereto,I certify that I am the owner,or am acting as the Owner's authorized
agent, and that the application and documents contained with this submittal are complete and
accurate�to the best of my knowlleedgeeaandnd abilities.
���'% `//��a-/..t. 4/18/2022
SIGNAT� DATE
Plumbing/Mechanical Permit Application
Updated December 2021 Page 3 of 3
Job Name:
Tag# rDAIKIN
Submittal Data Sheet 3MXS24RMVJU
3 Port, 2-Ton Outdoor Heat Pump
tr. Efficiency
SEER EER HSPF COP
e-i- - - - - 1.-7„." DAIKIN _
Non-Ducted 18 12.7 12.5 3.53
---=---= f Ducted 14 9.7 8.2 3.44
Mixed 15.95 11.2 10.35 3.49
:--,��
Performance
=��_.______—s' Cooling(Btu/hr)
—,—.-- � Rated 24,000
-, Operating Range 14°F-115°F
Rated Cooling Conditions: Indoor:80°F DB/67°F WB
Outdoor:95°F DB/75°F WB
e, f Heating(Btu/hr)
t r
Rated 24,000
pi=1z r:J Operating Range 5°F-60°F j
11 f I P E) Rated Heating Conditions: Indoor:70°F DB/60°F WB
Outdoor:47°F DB/43°F WB
`',iA RR A N-r
NEP
Complete warranty details available from your local dealer or at Electrical
www.daikincomfort.com.To receive the 12-Year Parts Limited 208/60/1 230/60/1
Warranty,online registration must be completed within 60 days of System MCA 21.9 21.9
installation.Online registration is not required in California or Quebec. System MFA 25 25
If product is installed in a commercial application,limited warranty Compressor RLA 15.5 15.5
period is 5 years.
Outdoor fan motor FLA .25 25
Outdoor fan motor W 73 73
Outdoor Specifications MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A)
Compressor Hermetically Sealed Swing Type RLA:Rated load amps(A) W:Fan motor rated output(W)
Refrigerant R-410A
Factory Charge(Lbs) 6.17
Refrigerant Oil PVE(FVCSOK)
Cooling Heating Piping
Liquid(in) %x 3
H 2,094 H 2,094
Airflow Rate(cfm) Gas(in) 3/8 x 1,
M 2,094 M 1,981 %2 x 2
Drain(in) 11/16
1,981 L 1,119
Max.Interunit Piping Length(ft) 230
Sound Power Level(dBA) 52/54 Max.Interunit Height Difference(ft) 49.25
Dimensions(H x W x D)(in) 28-15/16 X 34-1/4 x 12-5/8 Chargeless(ft) 131.6
Weight(Lbs) 137 Additional Charge of Refrigerant(oz/ft) .21
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 1 of 7
a
oa
L N
. 3 e0
✓ a
-c
H
co
m
U
HANDLE 9/16{14} 34 1/4(870) _I 3-9/16(90) WIRING
114(7) 12-5/8(320) 1-3/16{30) '7ERCONNECTINGPIPING OUTDOOR AIR THERMISTOR •c
Q •
a.
L BRAND NAME PLATE 1 E
„ ,_.. .___ ..._.._ r.
==,,,____,i,,_._
_-_._ _== _ _ f MANUFACTURERS �� I
M T_==-,
--______ LABEL _ NN _ — —_ _— _— / N •U
II 7 C O
\■ O Op•
• I 1 — N b00
O U zi
4-HOLES FOR FOUNDATION BOLTS `^ O
(MB OR M10) 23-5/8(600) 4 15/16(125) 14-1:2(368j m -a-ti , i,3-1/16(78} t o c
CO' — a al
110
In Q. '•i
z
1-=N LL O c
coI
O MINIMUM SPACE FOR AIR PASSAGE I c E
a�
i — p rn O(a z';r <ROOM A> WALL HEIGHT ON AIR OUTLET SIDE=LESS THAN 1200 ti 0
}r —i GAS PIPE y44,4•97.6,69 YWAW.viiri ti .OD
CO V i_ {43/8(49.5)SINGLE UNION) rn - 3
LIQUID PIPE - - J c
Q ^ '� 20 11/16(525) ($1/4(¢6.4)SINGLE UNION) y _
r rco
DRAIN OUTLET <ROOM B> i oco
• ,u
m GAS PIPE i V °? v v o
(I.D O(415.9)HOSE FOR CONNECTION b
Q (�1/2(�12.7)SINGLE UNION) ; co E v c
C WITHDRAINJOINT LIQUID PIPE 1-15/16(50) - m 1-15/16(50) )' s c
O 4-GROUND TERMINALS ( 1/4(46.4)SINGLE UNION} �s, o�1 . go rpm'
r GAS PIPE c tn.
{�1/2(�12.7)SINGLE UNION) % YO C� LIQUID PIPE o E
Q) _ III I (@1/4(46.4)SINGLE UNION) $ v
5iIII . el.1- b g o
+Ic 'III■� Q 7
A�
.-
[LIQUID 41l4(46.4) 2-9I16(ss) 1111
A muII1i1uI
a '
;� _M ''3 v N 115l16(SO)co — a 6cO N SERVICE PORT/ LIQUID STOP VALVE ` T " ° E
fGAS STOP VALVE v v
�y IN CASE OF REMOVING STOP VALVE C.3D093198
LL COVER AND TERMINAL STRIP COVER 1-11/16(43) 11/16(18) c
N Y
(0 0
N
s
CO 7 n
X o
gg
5
G -• E
C ) Q Ja
Optional Accessories P,
Included Part Number Description
DACA-WB-3 Mounting Bracket
KEH063A4E Drain Pan Heater 2/3/4MXS&2/3MXL
KPW063B4 Air Adjustment Grille
KKG063A42 Back protection wire net
KKG063A43 Side protection wire net
KPS063A41 Snow hood(intake side plate)
KPS063A44 Snow hood(intake rear plate)
KPS063A47 Snow hood(outlet)
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 3 of 7
3MXS24RMVJU Capacity Tables 7e'rEIAIKIN1
Non- Ducted, 60 Hz, 208-230V
Cooling Capacity of each indoor unit
a Heating Capacity of each indoor unit
Combination of indoor Each Capacity Total Indoor Unit Capacity
unit A room B room C room D room Rating (min"'max)
07 7.60 - - 7.60 7.30-8.40
8.80 8.80 8.70-9.70
09 9.80 9.80 7.40-10.80
11.30 11.30 10.00-12.50
12 13.00 13.00 7.50-14.40
15.00 - - - 15.00 9.90-16.70
15 16.30 - 16.30 8.90-18.00
18.80 18.80 9.40-20.80
18 19.50 19.50 8.90-21.60
22.50 22.50 9.40-25.00
07+07 7.60 7.60 15.20 8.90-16.80
8.75 8.75 17.50 9.30-19.40
07+09 _ 7.69 9.61 17.30 8.90-19.20
8.89 11.11 20.00 9.20-22.20
07+12 7.31 12.79 20.10 9.00-22.80
8.25 14.45 22.70 9.10-26.60
07+15 6.31 15.79 22.10 10.00-26.40
6.69 16.71 23.40 8.70-31.30
07+18 6.00 18.00 24.00 10.10-30.00
6.00 18.00 24.00 8.70-36.00
09+09 9.75 9.75 19.50 9.00-21.60
11.25 11.25 22.50 9.10-25.00
09+12 8.92 12.48 21.40 9.10-25.20
9.63 13.48 23.10 9.00-29.70
09+15 7.80 15.60 - - 23.40 10.10-28.80
7.93 15.87 23.80 9.70-34.40
09+18 7.06 16.94 24.00 10.10-30.00
7.06 16.94 24.00 8.60-36.00
12+12 11.70 11.70 - - 23.40 9.20-28.80
11.90 11.90 - - 23.80 9.00-34.40
12+15 9.88 14.12 - - 24.00 10.20^'30.00
9.88 14.12 - - 24.00 8.60-36.00
12+18 8.84 15.16 - - 24.00 10.20^'30.00
8.84 15.16 24.00 8.60-36.00
15+15 12.00 12.00 24.00 10.80-30.00
12.00 12.00 24.00 8.40-36.00
15+18 10.91 13.09 24.00 10.80-30.00
10.91 13.09 24.00 8.40-36.00
18+18 12.00 12.00 - - 24.00 10.90-30.00
12.00 12.00 - 24.00 8.30-36.00
07+07+07 7.13 7.13 7.13 - 21.40 10.00-25.20
7.70 7.70 7.70 23.10 8.60-29.70
07+07+09 6.98 6.98 8.73 - 22.70 10.10-27.60
7.26 7.26 9.08 23.60 8.60-32.90
07+07+12 6.40 6.40 11.19 - 24.00 10.10-30.00
6.40 6.40 11.20 24.00 8.50-36.00
07+07+15 5.33 5.33 13.33 - 24.00 10.80-30.00
5.33 5.33 13.32 24.00 8.30-36.00
07+07+18 4.80 4.80 14.40 - 24.00 10.80 30.00
4.80 4.80 14.40 - 24.00 8.30-36.00
07+09+09 6.86 8.57 8.57 - 24.00 10.10^'30.00
6.85 8.57 8.57 - 24.00 8.50-36.00
07+09+12 6.00 7.50 10.49 - 24.00 10.20^'30.00
6.00 7.50 10.50 24.00 8.50-36.00
07+09+15 5.05 6.32 12.63 - 24.00 10.90^'30.00
5.05 6.32 12.63 - 24.00 8.30-36.00
07+09+18 4.57 5.71 13.71 - 24.00 10.90^'30.00
4.57 5.71 13.71 - 24.00 8.30-36.00
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 4 of 7
3MXS24RMVJU Capacity Tables DAIK/IV
Cooling Capacity of each indoor unit
Heating Capacity of each indoor unit al
Combination of indoor Each Capacity Total Indoor Unit Capacity
unit A room B room C room 1 D room Rating (min^'max)
07+12+12 5.33 9.33 9.33 - 24.00 10.30-30.00
5.34 9.33 9.33 - 24.00 8.40-36.00
07+12+15 4.57 8.00 11.43 - 24.00 10.90"'30.00
4.57 8.00 11.42 24.00 8.30-36.00
07+12+18 4.17 7.30 12.52 - 24.00 10.90^'30.00
4.17 7.30 12.52 24.00 8.30-36.00
07+15+15 4.01 10.00 10.00 - 24.00 11.20^'30.00
3.99 10.00 10.00 - 24.00 8.20-36.00
09+09+09 8.00 8.00 8.00 - 24.00 10.20-30.00
8.00 8.00 8.00 - 24.00 8.50-36.00
09+09+12 7.06 7.06 9.89 - 24.00 10.30"'30.00
7.06 7.06 9.88 - 24.00 8.40-36.00
09+09+15 6.00 6.00 12.00 - 24.00 10.90"'30.00
6.00 6.00 11.99 - 24.00 8.30-36.00
09+09+18 5.45 5.45 13.10 - 24.00 10.90-30.00
5.45 5.45 13.08 - 24.00 8.30-36.00
09+12+12 6.32 8.84 8.84 - 24.00 10.30-30.00
6.31 8.84 8.84 - 24.00 8.40-36.00
09+12+15 5.45 7.64 10.91 - 24.00 10.90-30.00
5.45 7.64 10.91 - 24.00 8.20"'36.00
09+12+18 5.00 7.00 12.00 - 24.00 10.90-30.00
5.00 7.00 12.00 - 24.00 8.20"'36.00
09+15+15 4.80 9.60 9.60 - 24.00 11.20-30.00
_ 4.80 9.60 9.60 - 24.00 8.20^'36.00
12+12+12 8.00 8.00 8.00 - 24.00 10.40-30.00
8.00 8.00 8.00 - 24.00 8.40-36.00
12+12+15 7.00 7.00 10.01 - 24.00 11.00-30.00
7.00 7.00 10.00 - 24.00 8.20-36.00
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 5 of 7
3MXS24RMVJU Capacity Tables flDAIKI$
Ducted, 60 Hz, 208-230V
Cooling Capacity of each indoor unit
Heating Capacity of each indoor unit A
Combination of indoor Each Capacity Total Indoor Unit Capacity
unit A room B room C room D room Rating (min"max)
7.1 7.1 7.30-7.10
7 8.3 8.3 9.00-9.70
09 9.1 9.1 7.30-9.60
10.7 10.7 10.40-12.50
12 12.1 - 12.1 7.30-12.10
14.3 14.3 10.40-16.70
15 14.8 - - - 14.8 8.10-15.40
16.6 - - 16.6 10.10-20.80
18 17.6 - 17.6 8.10-18.80
18.9 - 18.9 10.10-25.00
07+07 6.95 6.95 13.9 8.80-14.30
7.9 7.9 - 15.8 9.60-19.40
07+09 7.02 8.78 - - 15.8 8.80-16.60
7.73 9.67 - 17.4 9.60-22.20
07+12 6.73 11.77 - - 18.5 8.80-19.90
7.13 12.47 - - 19.6 9.60-25.90
07+15 6.09 15.21 - - 21.3 9.40-23.30
6.23 15.57 - - 21.8 9.40-28.40
07+18 6 18 - - 24 9.40-26.60
6 17.99 - - 24 9.40-31.00
09+09 8.8 8.8 - - 17.6 8.80-18.80
11.05 11.05 - - 22.1 9.60-25.00
09+12 8.45 11.84 - - 20.3 8.80-22.10
8.79 12.3 - - 21.1 9.60-27.60
09+15 7.7 15.4 - - 23.1 9.40-25.50
7.77 15.53 - - 23.3 9.40-30.10
09+18 - 7.06 16.94 - - 24 9.40-27.00
7.06 16.94 - - 24 9.40-32.00
12+12 11.55 11.55 - - 23.1 8.80-25.50
11.65 11.65 - - 23.3 9.60-30.10
12+15 9.88 14.12 - - 24 9.40-27.00
9.88 14.12 - 24 9.40-32.00
12+18 8.84 15.16 24 9.40-27.00
8.84 15.16 - 24 9.40-32.00
15+15 12 12 24 9.90-27.00
12 12 - 24 9.10-32.00
15+18 10.91 13.09 - - 24 9.90-27.00
10.91 13.09 - 24 9.10-32.00
18+18 12 12 - - 24 9.90-27.00
12 12 - - 24 9.10-32.00
07+07+07 6.77 6.77 6.77 - 20.3 9.90-22.10
7.03 7.03 7.03 - 21.1 9.00-27.60
07+07+09 6.83 6.83 8.54 - 22.2 9.90-24.40
6.92 6.92 8.65 22.5 9.00-29.30
07+07+12 6.4 6.4 11.19 - 24 9.90-26.60
6.4 6.4 11.19 24 9.00-31.10
07+07+15 5.33 5.33 13.33 - 24 10.40-26.70
5.33 5.33 13.32 24 8.80-31.40
07+07+18 4.8 4.8 14.4 - 24 10.40-26.90
4.8 4.8 14.4 24 8.80-31.60
07+09+09 6.86 8.57 8.57 - 24 9.90-26.60
6.86 8.57 8.57 24 9.00-31.00
07+09+12 6 7.5 10.5 - 24 9.90-26.70
6 7.5 10.5 24 9.00-31.30
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 6 of 7
3MXS24RMVJU Capacity Tables D41/KIN1
Cooling Capacity of each indoor unit
Heati n
Combination of indoor Each Capacity Total Indoor Unit Capacity
unit A room B room C room D room Rating (min^'max)
07+09+15 5.05 6.32 12.63 - 24 10.40-26.80
5.05 6.32 12.63 24 8.80-31.50
07+09+18 4.57 5.71 13.71 - 24 10.40-26.90
4.57 5.71 13.7 24 8.80-31.80
07+12+12 5.33 9.33 9.33 - 24 9.90-26.80
5.32 9.33 9.33 24 9.00-31.50
07+12+15 4.57 8 11.43 - 24 10.40-26.90
4.57 8 11.43 - 24 8.80-31.80
07+12+18 4.17 7.3 12.53 - 24 10.40-27.00
4.17 7.3 12.51 - 24 8.80-32.10
07+15+15 4.01 10 10 - 24 10.70-27.00
4 10 10 - 24 8.60-32.10
09+09+09 8 8 8 - 24 9.90-27.00
8 8 8 - 24 9.00-32.00
09+09+12 _ 7.06 7.06 9.88 - 24 9.90-27.00
7.06 7.06 9.87 - 24 9.00-32.00
09+09+15 6 6 12 - 24 10.40-27.00
6 6 12 - 24 8.80-32.00
09+09+18 5.45 5.45 13.1 - 24 10.40-27.00
5.45 5.45 13.09 - 24 8.80-32.00
09+12+12 6.32 8.84 8.84 - 24 9.90-27.00
6.33 8.84 8.84 - 24 9.00-32.00
09+12+15 5.45 7.64 10.91 - 24.00 10.40"'27.00
5.45 7.64 10.91 - 24 8.80-32.00
09+12+18 5.00 7.00 12.00 - 24.00 10.40^'27.00
5 7 12 24 8.80-32.30
09+15+15 4.80 9.60 9.60 - 24.00 10.70"'27.00
4.8 9.6 9.6 - 24 8.60-32.30
12+12+12 8.00 8.00 8.00 - 24.00 9.90"'27.00
8 8 8 - 24 9.00-32.00
12+12+15 7.00 7.00 10.00 - 24.00 10.40^'27.00
7 7 10 - 24 8.80-32.30
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 7 of 7