My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit File BLD-2018-0399 2418 15th Street (2)
>
BUILDING CONSTRUCTION AND MODIFICATION PERMIT FILES (VALID)
>
Active
>
2418 15th Street
>
Permit File BLD-2018-0399 2418 15th Street (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2022 10:00:01 AM
Creation date
2/16/2022 9:59:53 AM
Metadata
Fields
Template:
PL_PermitFile
Street Name
15th Street
Street Number
2418
Parcel
P56405
Permit Number
BLD-2018-0399
Document Type
Permit
Address
2418 15th Street
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
6 -3 1 /2" <br />lluE copy <br />32" X 60" SHOWER TO BE SAME <br />JEWETT REMODEL <br />DIMENSION BOTH <br />3616 SL 3616 SL SIDES <br />4' VANITY <br />P <br />- <br />s <br />m <br />o <br />m <br />ELECTRIC WALL HEATER <br />v <br />M1 <br />EAST. ELECTRICAL <br />PANEL <br />HALF -WALL (4'TAU.) <br />DO MASTER <br />2'-6" AUGN W/ OVERHEAD BEDROOM <br />m <br />BESUITE <br />8 CEILING HT. <br />CLOSET <br />0 <br />I n <br />I <br />32" LOUVERED <br />BI-FOLD DOOR <br />AUGN WALL W/ <br />OVERHEAD BEAM <br />OPPICE NOOK <br />LIVING ROOM <br />F*7 <br />2418 15th STREET <br />ANACORTES, WASHINGTON <br />a HEADERS OVER NEW PARCEL # P5 6405 <br />m WINDOWS TO BE 4 X 8 DF2 <br />m <br />0 <br />N � <br />� J <br />W N <br />w � <br />3 <br />SD W <br />3065- <br />(90/co (90/CO 1 3 1-3 .1 <br />LINE OF EXIST. OVERHEAD <br />BEAM <br />(E) CONCRETE PATIO <br />INTERIOR REMODEL <br />PROJECT DESCRIPTION: INTERIOR REMODEL ONLY, NO CHANGES <br />TO BUILDING FOOTPRINT. EXISTING FAMILY ROOM TO BE <br />CONVERTED TO MASTER SUITE. <br />KITCHEN BEDROOM 2 <br />00 BEDROOM 3 <br />00 <br />DINING <br />oao <br />�� BATN <br />CARPORT <br />CITY OF ANACORTE 4jVjd d es i g n <br />PLANNING & BUILDING DEPT <br />DUNLAP <br />APPROVED PLANS JIM(360) 982-0-0535 <br />PERMIT III, �OI%� 03� JIM@JDDESIGNDRAFTING.COM <br />ADDRESS: y/g / s �� <br />APPROVEDBY: ficc�_/'acr� <br />SUWECT TO FIELD INSPECTION- APPROVED PLANS <br />WALL µ 'T BE ALTERED WIMAG 1T AUTF40RV.AT101`I <br />FLOOR PLAN NOTES <br />• THE FOLLOWING NOTES APPLY TO ANY NEW <br />CONSTRUCTION ELEMENTS OR ANY EXISTING <br />ELEMENTS BEING REMODELED. <br />• WRITTEN DIMENSIONS TAKE PRECEDENCE OVER <br />SCALED DIMENSIONS. VERIFY ALL DIMENSIONS AND <br />CONDITIONS IN THE FIELD. <br />• CONFIRM ALL DOOR, WINDOW, CLOSET, AND ANY <br />OTHER ROUGH OPENING SIZES WITH OWNERI <br />CONTRACTOR PRIOR TO WALL CONSTRUCTION. <br />• ALL WOOD IN CONTACT WITH CONCRETE MUST BE <br />PRESSURE TREATED MATERIAL USE CORROSION <br />RESISTANT FASTENERS WHEN IN CONTACT WITH <br />PRESSURE TREATED LUMBER. <br />• ALL INTERIOR WALLS TO BE FRAMED WITH 2 X 4 <br />STUDS AT 1(." O.C. AND SHEATHED WITH 1/2" GYPSUM <br />WALLBOARD UNLESS NOTED OTHERWISE. <br />• ALL GLASS TO HAVE LOW E (0.40) GLAZING. GLAZING <br />IN HAZARDOUS LOCATIONS TO BE TEMPERED PER <br />IRC SECTION R308. SEE R308.4 FOR DEFINITION OF <br />HAZARDOUS AREAS. <br />• PROVIDE SMOKE DETECTORS ON OR NEAR THE <br />CEIUNG OF EACH FLOOR, IN ALL BEDROOMS, AND <br />JUST OUTSIDE EACH BEDROOM. SMOKE DETECTORS <br />TO BE WIRED TO THE ELECTRICAL SYSTEM WITH <br />BATTERY BACKUP URC R311.1 i R311.2). <br />• BEDROOMS TO HAVE AT LEAST ONE WINDOW MEETING <br />THE FOLLOWING CONDITIONS: WINDOW SILLS TO BE <br />WITHIN 44" OF FINISHED FLOOR WITH A NET CLEAR <br />OPENING OF 5.1 SQ. FT. MIN. THE OPENING TO HAVE <br />MIN. CLEAR OPENING HEIGHT OF 24" AND WIDTH OF <br />20" URC SECTION R310). <br />• ALL SHOWER AREAS TO BE FINISHED WITH A SMOOTH, <br />HARD 6 NON -ABSORBENT MATERIAL TO MIN. 12" <br />ABOVE DRAIN INLET. THIS MATERIAL TO BE <br />INSTALLED OVER WATER RESISTANT PLASTER <br />BOARD. <br />• TOILETS TO BE LOCATED IN AREA WITH MIN. 30" <br />WIDTH OF TOTAL FINISHED CLEARANCE, AND HAVE <br />CLEARANCE OF MIN. 21" IN FRONT OF TOILET. TOILETS <br />TO BE LIMITED TO 1.6 GALLONS PER FLUSH. <br />• PROVIDE EXHAUST FAN IN KITCHEN AT MIN. 100 CFM <br />AND BATHROOMS AT MIN. 50 CFM. ALL FANS AND <br />DRYER EXHAUST TO BE VENTED TO OUTSIDE OF <br />RESIDENCE. <br />PROJECT NOTES <br />• AREA BEING REMODELED (THE PORTION OF THE <br />ENTRY <br />cLd <br />LA <br />FASTING FAMILY ROOM THAT IS BEING TURNED INTO <br />THE MASTER SUITE) IS APPROAMATELY 433 S.F. <br />• HOUSE HAS 8 GEIUNGS THROUGHOUT. <br />• MASTER BATHROOM TO HAVE IN -WALL ELECTRIC <br />PWDR <br />HEATER INSTALLED. <br />O <br />• COMBINATION SMOKE DETECTOR/CARBON MONOADE <br />DETECTOR DOES NOT NEED TO BE INSTALLED IF ONE <br />o o <br />ALREADY EASTS IN CLOSE VICINITY OF SUGGESTED <br />LOCATION (SEE NOTE ABOVE ABOUT SMOKE <br />DETECTOR REQUIREMENTS). <br />• ALL NEW WINDOWS ARE LABELED WITH THEIR <br />�� <br />DIMENSIONS OE: '361(p SL' = 3-6" WIDE X I'-b" HIGH <br />COVID PORCH <br />r—I <br />BEDROOM I <br />SLIDING WINDOW). <br />FLOOR PLAN <br />LAUNDRY <br />----------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />GARAGE <br />I <br />i <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />----------J <br />JUN 2 0 201E <br />CITY OF ANACOR?'r-^ <br />FLOOR PLAN <br />LEGEND <br />EAST. WALL <br />= <br />NEW WALL OR FRAMING <br />SMOKE DETECTOR <br />.SD/CO <br />VEX <br />SMOKE/C.O. DETECTOR <br />0AN <br />EXHAUST FAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.