Laserfiche WebLink
A <br /> �QFOR CODE c,OSo <br /> w�' 1� Y O <br /> M <br /> N�% Co'� 3- 6` NEW PERCENT OF LOT COVERED <br /> O FIELD 1N LOT AREA 8738 SQ. FT. <br /> EXISTING ROCKERY 78' ELEVATION Jr /, HOUSE,PORCH*DECK 3000 SQ. FT. <br /> SO ELEVATION ' PERCENT OP COVERAGE 35% <br /> li c�^"oc�o�T—o� ocv oc� �c roc o rover <br /> • <br /> • <br /> EXISTINGSLOPE <br /> 125.06' N <br /> -I 9c158'16"E 1\\ <br /> i <br /> 5'5ET BACK 0%SLOPE I ® .6 I, <br /> -4 TILL <br /> NEW IMPERVIOUS AREA <br /> 1 N` u u, it —' LOT AREA 8738 SQ. FT. <br /> 21_811 Beacom aasai . L3!I Q HOUSE, PORCH*DECK 3066 SQ. FT. <br /> 5�'` ill \, ICJ 20' j W CONCRETE DRIVEWAY I308 SQ. FT. <br /> Mr; - _ 1 '`i 0 I CZ TOTAL 4374 SQ. PT. <br /> Recommended to it 1 ;; I CZ j PERCENT OF IMPERVIOUS 50% <br /> shift perforated stubN y,,�o� r ".`r ;;' ModL —---------- mIm w o �by k=t_ , II <br /> out away from the .S 5 _ `Y " 1J O <br /> D N a 4"SOLID PIPE I !tt! 1 D 0'] <br /> as m FROM ROOF s----I 1` ,-L i- O z <br /> foundation, so t0 �• ONQ r 4FOOTING FTTTT�-- \ (2121 <br /> not infiltrate into the oI• <br /> o -._ 1 = �_=' FJ I o I <br /> building area. o. 5`6' Grea,Raom 1 1 1 1 1 o f z <br /> oI, I I• DRAWING INDEX: <br /> T k--------- z = <br /> BMP T5. ___ 75.5' ELEVATION <br /> PERFORATED STUD °' i = Q I . SITE PLAN <br /> OUT CONNECTION ,i_r_�t—J~- <br /> /�' 4"PEREPIPE I covered Dec. I; LT-- 1 m • Q 2. CONSTRUCTION SITE PLAN <br /> 57.5'ELEVATION I T •'I II \-f\ j I II I <br /> ) Bedroom I Bedroom 3. LANDSCAPE PLAN <br /> DRIVEWAY o <br /> :' >11111m ,I1-1 POWER <br /> I 20' Maximum ELEVATIONS <br /> mill � !IB II 5. NORTH SOUTH ELEVATIONS <br /> 9 I'-I I" L________�L G � =�_____ _ POWER, <br /> I driveway width at 6. MAIN FLOOR PLAN <br /> �� sir, _= CI WATER II <br /> • I ,� lo'SEI BACK —I b• <br /> '' I curb cut. 7. DAYLITE BASEMENT PLAN <br /> I 4 SOLID PIPE :�% 8. FOUNDATION PLAN <br /> EXISLOP SANITARY SEWER • 9. UPPER FLOOR FRAMING PLAN <br /> E SLOPE <br /> 2'DEEP\jai <br /> 10. ROOF PLAN <br /> ' N89c15G'IG"E I25.00' DRIVEWAY II2. RROOF <br /> SECTIONALS S <br /> I-�STORM SEWER <br /> 55' ELEVATION tl" 20'x 5'ACCESS EASEMENT — TO 27 I 0 <br /> 73' ELEVATION PINE HYDRANT I <br /> .,....1K.... <br /> RANDOM FILL I CITY OF ANACORTES <br /> 2�uaw FILTER FABRIC <br /> Z '' ""Y 4'PEREPIPE �/,r CANNING AND BUILDING DEPT: <br /> li <br /> I `��=A'_—� APPROVED PLANS <br /> I-I/2"ED R REVIEWED FOR CODE COMPLIANCE <br /> I WASHED ROCK �— <br /> za^ =1 <br /> .m.. <br /> 1' <br /> wa�s,.ii BCD-2021-0073 <br /> PERFORATED STUB .nlm�nm�nmin■mMMIi,,;i:;r;,i,x - W PERMIT#: <br /> s m uis mmnn s mmnn�. <br /> OUT CONNECTION " '"""'I"""""""""""""""c°'I ADDRESS: 2706 Washin ton Blvd <br /> nnnnnmmnnnnmmunnnmmnnnm_ J <br /> SECTIONAL .,immmm�nnnnNINNmnnnnmm�m <br /> ni nn�mmm�mmm�mnnu�mmm�■u ) <br /> „' minmmmmnmm�,■nmmnmZIONEmm�,■nnlnnn■ ,.g:,:•':;.r': ,.E,.r•': ',^n,."•:^",^E,.I :' 9-5. APPROVED BY: <br /> BMP T5. IOC nmm�mnmm�mm�mm�mm�mm�nnnmm�mm�nmm w 2,f <br /> .,,.,:,.,:.+:emnnnmm�ul■nmm�nnmm�mmumn nmm�nnnmm�nnu:. .::.::.:.:.:.:.:.::a dr:ir',a,^xra r',:IE',Eexra r'r:EAvE':°ra r'r: j� <br /> TOP PLATE mmmnmmm■mm�■mnpmn■mnpm■ nn�__mnpmn■mnpmnl a +.,,..,,. 75.5 OI Q `./'FIGURE I I I—3. I .8 ELEVATI N u SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT <br /> I uJ w <br /> 33' 9 1/ —.`�—'�0000 �' N BE ALTERED WITHOUT AUTHORIZA ON. <br /> —I ICI ICI I _-- <br /> SUB-FLOOR a 1►i. I► ,—IU—lil—u-9,.=_'- . . <br /> l 0o PI ATE II II 1 1 1 I _ _ f <br /> IIIIII.IIl1!1�ll11 ---■ — i 1-------- l 0 1 2 I, MID-ROINr .. I I"x 1 7"PAPER SIZE---SCALE 15 1"=20' (COPIED @ 100%) <br /> - <br /> LLJ I 9 EXISTING GRADE EXISTING GRADE <br /> ----- ---------- 22"x 34"PAPER SIZE---SCALE IS I"= 1 0' (COPIED @ 200%) <br /> REV.#1 02/04/2 I <br /> z TOP of SLAB <br /> E R2 ZONING <br /> �I___ D ICK FRAME <br /> ELDING SITE PLAN <br /> F� EXISTING GRADE WOO <br /> �' 57.5' ELEVATION BUILDER TO VERIFY ALL DIMENSIONS HARLON MILES RESIDENCE <br /> �I CONSTRUCTION NEEDS TO COMPLY WITH <br /> 2015 WASHINGTON STATE ENERGY CODE(WSEC) ADDRESS: 2706 WASHINGTON BOULEVARD <br /> BUILDING TO COMPLY WITH THE <br /> IRC 201 5 BUILDING CODES PARCEL #: P 117653 <br /> PLUMBING TO COMPLY WITH THE <br /> 201 5 UNIFORM PLUMBING CODE XrefId: 4770-000-027-0000 <br /> FOR FAMILY DWELLINGS <br /> DRAWN BY:BRUCE RUSTAD DATE: 07/20/20 <br />