Loading...
HomeMy WebLinkAboutPermit File 2611 Fir Crest Boulevard `.S Y o„ CITY OF ANACORTES 4WASHINGTON 2 �' BUILDING DEPARTMENT cos' CERTIFICATE`OF OCCUPANCY This is to certify that the(Description of Building or Structure): ., , Single Family Residence Located At: 2611 Fircrest Blvd. it STREET&NUMBER Owner: Strandberg Construction Constructed By: owner OWNER OR CONTRACTOR Bldg. Permit#: BLD-2004-9670 Date Issued: September 22, 2004 Occ. Group: R3 Use Zone: R2 I Has Been Inspected And Occupancy Is Hereby Authorized. k[ This 9th Day of June 20 05 6 CI AUT110RIZ1 F ICIPL SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. TV OF ANACORTES "AS-BUILT" Sewer {�, ET�'Storm NTRACTOR: :7Y7#cKlipi s`1-C., ti•, L, kT/DIVISION: 1-1itt4Zc Y Lo'r I BLOCK TADDRESS: 2 it f-1Qets TE: 1 2--l3 -&'1 • ZMIT# J J 1 14170 SCALE P-%/r E _ ��1 TREET ��-- Ctill - - a 11 NMI MEMBEnOMMEMIE.11111====n11111 �.�..�=IMMO= N. nr1111 N� t iiMEMIENIF__BILI...Partisidllia. Er 1===1111111a111. Lim SEMI 'ATE STREET(S)ON GRID MAP WATE DEPTH AND DISTANCES OF CLEANOUTS TY OF ANACORTES "AS-BUILT" RSewer Storm NITRACTOR: 5://24W40Bi�U, EX C� £pg \T/DIVISION: it\12C...a+%5'I_ to V 1 3 BLOCK CADDRESS. i(: hi Cltzeasy gt,.Vt) TB: 7-Z3 -01 4ITa :�'c'c y y1/7G SCALE ref r-a- = TREET J,. CCA:• L r r / •i 1:59ri - �! _1 r i t-Lc at-s ::Rd 41(, CATE STREET(S)ON GRID MAP 7CATE DEPTH AND DISTANCES OF CLEANOUTS 0426604-1 0009 09/22/2004 002 4 Permit Fees 003054 $8,844.98 it) Y O fi, City of Anacortes Permit#: BLD-2004-9670 904 6th Street Issue date: O9/22/2004 P.O.Box 547 Expire date: 09/22/2005 "�'`-__—r CO. Anacortes, WA 98221-0547 ' w (360) 293-1901 C Job Address: 2611 FIR CREST BLVD Permit Type: Single Family Residence Permit ANACORTES WA 98221 Project: APN: Remarks: New single family residence. Owner: STRANDBERG CONSTRUCTION Contractor: STRANDBERG CONSTRUCTION Address: PO BOX 319 Address: PO BOX 319 ANACORTES WA 98221 ANACORTES WA 98221 Phone: (360)293-7431 Phone: (360)293-7431 License#: STRANCI020CC General Information: Fees: Lot Area 5789 Plan Review Deposit 100.00 1st Floor Square Footage 1472 Building Permit Fee 800.50 2nd Floor Square Footage 980 Plan Review Fee 420.33 Garage Square Footage 555 Mechanical Permit Fees 114.65 Building Valuation 246815 Plumbing Permit Fee 132.00 # Forced Air Furnace <=1,000 1 State Building Code Fee 4.50 #of Bathtubs 2 Sewer Inspection Fee 50.00 #of Clothes Dryers 1 Storm Drain GFC-Residential 1,126.00 #of Clothes Washers 1 Sewer GFC-Residential 4,682.00 #of Dishwashers 1 Park Impact Fee 615.00 #of Gas Fireplace 1 Traffic Impact Fee 900.00 #of Gas Piping 1 Total Calculated: 8,944.98 #of Gas Water Heaters 1 Deposits/Receipts: 100.00 #of Water Piping 1 #of Hose Bibbs 2 Total Due: 8,844.98 #of Kitchen Sinks 1 #of Lavatories 3 #of Range Hoods 1 #of Showers 2 #of Ventilation Fans 4 ' #of Water Closets 3 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY ...,.:.>:. .. ..:.. liga Stu,ADDRESS: 2(el i • 1 `t re 4-6 V U d. ASSESSOR Na: LOT: ( 3 BLOCK: DIV: • ADDITION: 1 /1. Cre5 — . _ ... : :: ... . ....... : .:.. ..::...:..:<> :.>..>.,,_:,>;,<..z,o:•..: as,.,,:.e:<Mes,'<..: c-,.:.<a..;ri ,a.�.`?�::;;r<;s=::: •.<..W.,».:..:W>:.::3``.`.<::.,.:,:-.vyi?,?>a<<ri-ay>v;a»;rim,.- I+:AQAYk::w:<R::nri,'::.aw:+Sj:.:.>.w.. �:.>:.:,:>.:;.>.a..t,.a.::.-..,.. .:. <,,,-:,.;.� ,_.::»;::.:. ' ..:....._.,,,:...s.::.,.,.,aaa.::..,:....,.:£'.,�+l`l`I2A... ..>.. ...,..xx.,.,:._. ... ,�R>�.,>,r.�.y�y�� , :<:. sad 'phi. �».:-.: �, 'T]) R:;_ �;:x4hz�;. >;.,.....�<�':,ptf.YAi.1.l�:S:Cr:iaL,>u::as.:,-o-`:^:�:��s::'.:-:,iri•: n?:::-.'„::`<'.n.,aa'>� ..._ .. -: _. ... ...... . ... .. - . Name: Name: Name: Zinc- Mailing S trc .i-.c. oad5, Covt5'M a:L ta.S h:K) h.>. �-cd '-'(-e S-h-andlar s au-4 tvt.-cKe-, . Address: Mailing Address: Mailing Address: `- 0 "3o'F- 3lei i(°"` + (orn.,,, )0 3e/- lit City: State: Zin: City: State: Zia: City: State: Zio: , nti.L6+/kr; wA . inn I .cavitss Ltt 98zzt . u.c ) Lai %zz I Phone No.: Phone No.: • • Phone No.: (36a1 2-13 ^7 Y 3 ( Contractor License: Contact Person: VOe..S or tharliC- PhoneNo.: (d..l-o`toy (Akh) O.i - 124`tCCl'tm- I.'Icl .....,.:.:o:.::.:.:.::..a,v-.vx:-v..v:reRliayu.a[.y,yam:.:,romp..a.,,>r...r.'»'-nixw5:..>t:,y '` : ..^ >r....'t^� aAN.v:._ vvi'<xyT.x•......�:.n.,:.,.:o:r .L,. rmG-ax<3... .»,..t x:.:. ....i..o. .-:, .::ay.: _.,:.:,_.,M.,.,9.[:a.,..a./vtt..-..,�„:>.:.. .>. .,. '> ,_>..: .. ):.:.,ny:`.:'. wti:<>w,vorc>Y>a..n"a:v.,.i�:Y +=_>.a-.,. ti4::,..<.,aii.. a.>:..-:.<::.�;.:. . a . :....�5�:.:..r:.ah:x_.,.,y.::.:....ru^�:,. :..w^g::`...<..,<.:.<..ii<.a:..:. .._.. .. ... ... .._. t::,._ ... ..;h:.,F,,:<.:. ,a<:>r..>:::>.:waw:.:-:�-.>;£<:�.,.:.-».:hA::hi...,.h:,.: :a.aoceur.ArrT. :>.:..,.. .. .__ , . . :.., .�:.� �.� ow::-�a^o`.Y:'i.,',..c<eJ>:}.r.a::>i�.�t G_Ry::`:;.•a: a-.:...).a':yF..^,:✓.,.y:.: >y>:a:..,r•:`::...:,,,...,v..:.:.. ... . ... ..: ..........z..e. .._ :<:> ...a+.. (Check One) Single Family: Multi-Family: Apartment: Condominium: Senior Housing: Retail: Office: Restaurant: Manufacturing: Storage: Bank: Assembly:____ Accessory: Automotive Repair: Other(Specify): DESCRIBE OF WORK: LSTI — si:r<. i. <~:>r:~; s:::>'c; >;»:> i=';:" 1 MAT .ON.: :'><>_;<:.<i; ;: '>:t":::« i.<:;:<,:: >::::::: .:i >:::_:: ;<? ea x GEI`IERAT:IFFt� a. nawizf >_. - :.;aa;<:.ta:;.;auvca:e;:aaa...;av,xs.:.,v. 'vN-`.s:;;z::.i::z;'aw::A;:,:asaahe.A.:,tarTd,:oS-r.�a:;tz<-:._.:>nogv,�..,::.,:>:e,.a awsh:`:%kk::�'i`,.»asa.•.rav Xo:'.::>.. ISSIMIN Street Setback: /o ft. 2nd Floor q g 0 sf. (Circle Y or N) 1st Side Setback: 5 ft. 3rd Floor. q3,t 2nd Side Setback: SIZo ft. Basement: sf. Shoreline/Wetlands (D N t Rear Setback: 5 ft. Occ. Group: Water on/Adj. to Property N Use Zone: #'-1 t''�a Carport Area: sf. Soils Report N Type of Construction: LJoaLT-rtmc- Garage Area: 55 S sf. Sensitive Area a) N Lot Area: 578'9 sf. No. of Stories: 2-..I-d4S7S Latecomers Agreement Y No. of Dwelling's:, ) Building Height:Z 3 '(o''sf. Fire Hydrant(250 FT) N Lot Coverage:_ _ 3j,1, Deck Area: sf. Variance Y 1st Floor: j 4 72 s£ 3 `I h Covenant Y .._. q 0 `tr / )5 Project Valuation(Labor and Material Cost): r THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE OVISIONS1OF THE UNIFORM BUILDING CODE, AND SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED IirthIt;t t�8o' AY$OF'°°THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PR6PERTY FOR-WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HERE OT,INCLUD FOR INSP TIO. • +'�, ^ P, , SIGNATURE: 2 ''ft,.=F._____ - DE4E1 : ,/ / 4 / F.:n.Y: wj:.:..: . .ter>,:".::...:. ........:.:..>y :x!. :.: !A ..:. :. .:a/;^..('p.(\p NINZTELUIVIBINSP&ZIE✓':.>..}...:->i :::>.>r,.._:..,..:.>r:.: v:. .::.. :m:..(/''}�::.c:'::^ Qjpp''':� `fix SITE ADDRESS: 2(e t k;,r Cie* 1,1 v 1 ASSESSOR'S NO .: LOT: 13 BLOCK: ADDITION: r i — Cv St ,y5 S x.:<. .fx i, ».�i!n .a.�.;;<:a. C>;:1:<.x :ax. � <'>'s:^"% �j.?rA::„�,„v, ..A .` :a. :�'`ro:.mre:.%µo,Yn`:7:Yan...F?ar':�i.!:.0.«:. :^,.iidGyP):?»xww«\:YF4✓. 1ST ,}?i7%.>:,. .,..a6!..x:>n,.F,��.a v.Q>i;?�..n? Uy<�'.".:'.'�:'.ma.:v... y'�� '�y ...... ... ..... ....... .. cy�'f m�:.bq.'F.S ems.u:. : � .�.1'Y. .L]�y�F<F:nyT 'm> :..wino a.S'a:..na .:.F:F f.,.:..a.:..:_n,...v..:.. ._,n:... ........... ..... ...:xH».[..utF+r.<,F'.�r:I:;,... ....c>y,:.:n..:::i, •y...i». . >: t: Name: S'f'fonako n.� ('�,,..s-}ns th;0—. Tnc. Name: 3tro ncAcsj Cov.S'iur...-�ja1 lc. , . Mailing Address: phi o 3a* 3tek Mailing Address: -NA< 311 City: Aw1c.f1Fca State: wA. Zip: gtz21 City: Ank.c..l-c3 State: wit: Zip: ?8221 Phone No.: ($_4.0) 211- 7./3 ( Phone No.: (36o) 213 - 7 eV Contractors License No.: STQA rut Iotocc .,. <...:....:...... ....n.... ... .i.,........v....... ii/......I.....n v.:.. ..... ...:x>v...:.... :.:... ..f...rv:..:.}..�'.::.ii/.,.'r A ::>An>`e'%.:.�Q::[:/CY: ..:n...!i:..,:x:,..:.n...:vn.... (�!irnJett:.:..✓<:...n;....::qu:.....a .i:i.viv..... n x..,. n.» .. .n, }y� �(Y� gj]rpgl..:v:� N?5�:+�� � n.!:i:>x--...3.:n<en...>,..p..I. :.:..:.:v... ....:.r.o nn <.:. :rv:ir^ »v.<[m.. .....>i'0. �4:�V 4 } NO: Type of Fixture NO: Type of Equipment gl Water Closet 1.5 GPI" Air Cond. Unit HP ..... Bathtub Refrigeration Unit HP it Shower 2.5 GPM Boiler BTU/HP / Dishwasher 2.5 GPM J Forced Air System um '3 Lavatory 2.5 GPM Floor Furnace I Kitchen Sink 2.5 GPM Wall Heater I Clothes Washer J` Clothes Dryer Urinal 1.0 GPM 7 Ventilation Fan Drinking Fountain / Range Hood Floor Sink or Drain Air Handling Unit CFM Slop Sink Pre-Manf. Stove or Fireplace IWater Piping / Gas Fireplace l' Hose Bibs Gas Water Heater Back Flow Prevention Device Gas Piping Other(Describe) Other scribe) GA ELEC: OTHER: THIS APPLICATION IS RECEIVED BY THE BUILDING DEPARTMENT UNDER THE PROVISIONS OF THE UNIFORM PLUMBING AND MECHANICAL CODES AND SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN 180 DAYS OF THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCE GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITH, WHETHER SPECIFIED HEREIN OR NOT, INCLUDING CALLS FOR INSPECTION. SIGNATURE: c� DA1h: �X2 ar Washington State Energy Code: 2001 Edition, Prescriptive Worksheet Zone 1 Conditioned Floor Area 2452 Glazing Area Contractor Strandberg Construction Inc. Area Weighted PO Box 319 Feet2 U-Factor Anacortes WA 98221 Vertical Glazing 339.0 0.33 Overhead Glazing 16.0 Fir Crest Phase I Door 20.0 0.49 Lot 13 2611 Fir Crest Boulevard 602.7.2 Exception, Area X 3_ Glazing Area Total 375.0 Glazing To Floor Area Ratio 15.3% Glazing Atea Total/Conditioned Floor Area 602.7.2 Exception Ratio 602.7.2 Glazing Area Total tCandi,oneFloor Area,not to exceed 1% ' Table 6-1 PRESCRIPTIVE REQUIREMENTS"FOR GROUP R OCCUPANCY Select CLIMATE ZONE 1 One Option Glazing Glazing U-Factor Doors Wall Wall Wall Slab4 Option Area0 U- Ceiling"` Vaulted Above Int" Ext4 Floors On � %of Floor Vertical Overheadil factor Ceilings Grade Below Below Grade Grade Grade I 12% 0.35 0.58 0.20 R-38 R-30 R-15 R-15 R-10 R-30 R-14 I� II* 15% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 III Unlimited I I Group R-3 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Occupancy Only See code text for footnote references Exterior Doors Plan Component Door Percent Width Height Glazing Door Door ID Description Ref. U Glazed Qt. Feet 1noh Feet Inch Area Area UA U A =UXA 3ft fiberglass codel doors garage 0.500 2 3 6 8 40.0 20.0 fiberglass french door 0.480 50% 2 3 6 8 20.0 40.0 19,2 One Exempt Door, If 24 Square Feet or Less. 1 3 6 8 20.0 Sum of Area and UA(do not include exempt door) 20,0 80.0 39.2 Area Weighted U= UA/Area 0.49 Copyright 2002 WSUCEEP 02-054 Copie ermission from Washington State University Cooperative Extension Energy Program. (see copy__ 'ons) 5/18/2004 1 of 2 Washington State Energy Code: 2001 Edition, Prescriptive Worksheet Zone 1 Vertical Glazing (Windows, Doors using Exception 602.6 #1) Plan Component Glazing Width Height Glazing ID Description Ref. U Qt. Feet Inch Feet inch Area UA U A =UXA vinyl with low a squared picture W01 0.310 2 1 6 6 18.0 5.58 vinyl with low a squared picture W02 0.310 3 2 2 12.0 3.72 vinyl with low a squared xo W03 0.340 2 3 4 24.0 8.16 vinyl with low a squared xo W04 0.340 2 4 2 16.0 5.44 vinyl with low a squared glass block W05 0.340 1 4 4 16.0 5.44 vinyl with low a squared xo W06 0.310 2 4 4 32.0 9.92 vinyl with low a squared picture W07 0.310 4 4 6 96.0 29.76 vinyl with low a squared xo W08 0.340 2 6 5 60.0 20.40 vinyl with low a squared xo W09 0.340 2 5 4 40.0 13.60 vinyl with low a squared xo W10 0.340 1 5 5 25,0 8.50 vinyl with low e squared vinyl with low a squared vinyl with low e squared vinyl with low e squared vinyl with low a squared Sum of Area and UA 3390 110.52 Area Weighted U= UA/Area 0.33 Overhead Glazing Plan Component Glazing Width Height ID Description Ref. U Qt. Feet inch Feet Rich Area UA U A =UXA no skylights 2 2 4 16.0 Sum of Area and UA 16.0_ Area Weighted U=UA/Area Section 602.7.2 Exception Plan Component Width Height Area ID Description Ref. Qt. Feet inch Feet inch Area X3 Sum of Area and Area X3 Copyright 2002 WSUCEEP 02-054 Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 5/17/2004 2 of 2 City of Anacortes 2001 WSEC&VIAQ Residential Prescriptive Compliance Form Page 3 of 6 (a) (b) Glazing Percentage In order to use option I, the glazing percentage cannot exceed 12%. In order to use option II,the glazing percentage cannot exceed 15%. WHOLE HOUSE VENTILATION USING THE PRESCRIPTIVE METHOD Purpose: We have all heard about office and school buildings which cause people to become ill.If improperly ventilated,our homes can cause some of us to become ill too.With all of the new materials we use to construct and furnish our buildings, it is very important that our homes are ventilated in such a way as to provide us with method to get the stale air out and fresh air in. Please check the appropriate box to describe which of the four prescriptive Whole House Ventilation Systems you will be using,and fill in any blanks or boxes under the system you choose. Option 1. Whole house Ventilation Using Exhaust Fans(VIAQ 303.4.1) ❑ CFM Exhaust Fan Flow Rating Per Table 3-2(attached). Location of whole house exhaust fan(s)must be shown on the plans O Fan Controls:24 hour dock timer with capability of continuous operation,manual and automatic control&accessible O Whole house fans located 4 feet or less from the interior grille shall have a sone rating of 1.5 or less at 0.1 inches w.g. O Outdoor Air shall be distributed to each habitable room by individual Outdoor Air inlets. Exception:Exhaust only ventilation systems do not require outdoor air inlets if the home has a ducted forced air heating system that communicates with all habitable rooms and the interior doors are undercut a minimum of 4 inch. Option 2. Whole house Ventilation Integrated with a Forced Air Heating System(VIAQ 303.4.2) ❑ inch Fresh air duct,connected to the furnace return plenum,sized Per Table 3-5(attached) , ❑ Fresh Air inlet duct Damper Selection:(Choose one) Motorized Damper(no testing of ventilation flow rates as long as the prescriptive duct sizing per Table 3-5 are met EIManual Damper meeting Table 3-2 flow rates: CFM(see attached Table 3-2) El Automatic Flow-Regulated Device per VIAQ 030.4.2.1#3.(Requires field testing or calculation.) O Outdoor Air inlets shall be screened or otherwise protected from entry by leaves or other material and located per VIAQ 303.4.2.4 O All Ventilation supply ducts in the conditioned space shall be insulated to a minimum of R-4(VIAQ 303.4.2.3) IIOption 3. Whole house Ventilation Using a Supply Fan(VIAQ 303.4.3) ❑ inch Outdoor air inlet duct,connected to the furnace supply air stream,sized Per Table 3-6(attached) O Fresh Air inlet duct Back-draft Damper Selection:(Choose one) 0 Calibrated manual volume damper installed and set to meet the measured flow rates in Table 3-2(attached)by field testing with a pressure gauge and/or following manufacturer's installation instructions. ElA manual volume damper installed and set to meet the measured flow rates specified in Table 3-2 by field testing with a flow hood or flow measuring station. ❑ An automatic flow-regulating device sized to the specified flow rate in Table 3-2 which provides constant flow over a pressure range of 0.20 to 0.60 inches water gauge. O Outdoor Air inlets shall be screened or otherwise protected from entry by leaves or other material and located per VIAQ 303.43.6 0 All Ventilation supply ducts in the conditioned space shall be insulated to a minimum of R-4(VIAQ 303.43.5) 0 Option 4. Whole house Ventilation Using a Heat Recovery Ventilation System(VIAQ 303.4.4) ❑ AR duct work in heat recovery system shall be at least 6 inches in diameter D Balancing dampers shall be installed on the inlet and exhaust side. O Flow measurement grids shall be installed on the supply and return. O System minimum flow rating shall not be less than specified in Table 3-2.Maximum rates in Table 3-2 do not apply. O Outdoor air inlets shall be screened or otherwise protected from entry by leaves or other material and located perMAQ 303.4.4.4 0 Ventilation Supply Ducts in the conditioned space upstream of the heat exchanger shall be insulated to a minimum of R-4(VIAQ 303.4.4.3) THE FOLLOWING ARE REQUIRED IN ADDITION TO THE OPTION CHOSEN ABOVE: City of Anacortes 2001 WSEC&VIAQ Residential Prescriptive Compliance Form Page 4 of 6 ❑ At the time of final inspection,the automatic control time shall be set to operate the whole house fan for at least 8 hours per day, ❑ A label shall be affixed to the control that reads'Whole House Ventilation'(see operating instructions) ❑ 24-hour clock timer installed with capability of continuous operation,manual and automatic control,readily accessible. ❑ Installer shall provide the manufacturer's installation,operating instructions,and a whole house ventilation system operation description. REFERENCE TABLES Table 3-2: Ventilation Rates for all Group R Occupancies four stories and less * Minimum and Maximum Ventilation Rates: Cubic Feet per Minute(CFM) Floor Number of Bedrooms Area.flz 2 or less 3 4 5 6 7 8 Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. <500 50 75 65 98 80 120 95 143 110 165 125 188 140 210_ 501-1000 55 83 70 105 85 128 100 150 115 173 130 195 145 218 - 1001-1500 60 90 75 113 90 135 105 158 120 180 135 203 150 225_ 1501-2000 65 98 80 120 95 143 110 165 125 188 140 '210 155 233 _ 2001-2500 70 105 85 128 100 150 115 173 130 195 145 218 _ 160 240 _ 2501-3000 75 113 90 135 105 158 120 180 135 203 150 225 165 248 - 3001-3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 _ 3501-4000 85 128 100 150 115 173 130 195 145 218 160 240 _ .175 263_ 4001-5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 - 5001-6000 105 158 120 180 135 203 150 225 165 248 180 270 195 293 - 6001-7000 115 173 130 195 145 218 160 240 175 263 190 285 205 308 - 7001-8000 125 188 140 210 155 133 170 255 185 278 200 300 215 323 8001-9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 >9000 145 218 160 240 175 263 190 285 205 308 220 330 235 353 - . For residences that exceed 8 bedrooms,increase the minimum requirement listed for 8 bedrooms by an additional 15 CFM per bedroom. The maximum CR4 is equal to 1.5 times the minimum Table 3-3: Prescriptive Exhaust Duct Sizing Fan Tested CFM @ Minimum Flex Maximum Length Minimum Smooth Maximum Length Maximum Elbows 0.25"W.G Diameter (feet) Diameter Feet h . • SO 4 inch 25 4 inch 70 3 — 50 5 inch 90 5 inch 100 3 50 6 inch No Limit 6 inch No Limit 3 • 80 4 indh2 NA 4 inch - 20 3 80 5 inch 15 5 inch 100 3 • 80 6 inch 90 6 inch No Limit 3 100 5 ince NA 5 inch 50 3 • 100 6 inch 15 6 inch No Limit 3 125 6 inch 15 6 inch No Limit 3 125 7 inch 70 7 inch _ No Limit 3 1. For each additional elbow subtract 10 feet from maximum length 2. Rex ducts of this diameter are not permitted with fans of this size. Table 3-5: Prescriptive Integrated Forced Air Supply Duct Sizing Required Flow(CFM)Per Minimum Smooth Duct Minimum Roble Maximum Maximum Number of Table 3-2 Diameter Duct Diameter Lenat h' lbows2 - 50-80 6" 7" 20' 3 80-125 7" 8" 20' 3 115-175 8" 10" 20' 3 170-240 9" 11" 20' 3 1. For lengths over 20 feet increase duct diameter 1 inch 2. For elbows numbering more than 3 increase duct diameter 1 inch. Table 3-6: Prescriptive Supply Fan Duct Sizing City of Anacortes 2001 WSEC&VIAQ Residential Prescriptive Compliance Form Page 5 of 6 Supply Fan Tested at 0.40"W.G. Specified Volume Minimum Smooth Duct Minimum Flexible from Table 3-2 Diameter Duct Diameter 50—90 CFM 4 inch 5 inch 90-150 CFM 5 inch 6 inch 150—250 CFM 6 Inch 7 inch 250—400 CFM 7 inch 8 inch SOURCE SPECIFIC VENTILATION (VIAQ 302.2 Source specific exhaust ventilation is required in each kitchen,bathroom,water closet, laundry room,indoor swimming pool,spa, and other rooms where excess water vapor or cooking odor is produced.Source specific ventilation systems must be controlled by a manual switch,de-humidistat,timer or other approved means.Controls must be readily accessible. Ducts must terminate outside the building. Exhaust ducts which are designed to operate intermittently must be equipped with back-draft damper.All exhaust ducts in unconditioned spaces must be insulated to a minimum of R-4.Terminal elements must have at least the equivalent net free area of the duct work.Terminal elements for exhaust fan duct systems must be screened or otherwise protected from entry by leaves or other material. Table 3-1: Minimum Source Specific Ventilation Capacity Requirements Bathrooms Kitchens Intermittently operating 50 cfm 100 cfm Continuous operation 20 cfm 25 cfm Please be sure to note the locations of your source specific fans on your construction drawings and include the cfm rating you plan to install. MOISTURE CONTROL (WSEC 502.1.6) In order to help prevent moisture from collecting within the framing of the building,a vapor retarder must be installed to minimize vapor movement through what is called the diffusion process.Components of the house requiring a vapor retarder are: - Floors between heated and unheated spaces. - Walls—on the inside(warm side in winter) - Ceilings averaging less than 12 inches of ventilated area above the insulation to the underside of the roof sheathing. Check the appropriate boxes to indicate which method of interior vapor retarder will be used to meet Moisture Control requirements: MATERIAL LOCATION Exterior Grade Backed , 4—Mil Clear Vapor Retarder Paint Not required if ventilation space Plywood or OMPlastic 2 (1.0 perm rating) average 12"above insulation Floors N/A N/A N/A Walls N/A N/A Ceilings N/A 1 Backed baits at walls and ceilings must be faced stapled.(Paper should extend over studs or rafters towards interior heated space) 2 Plastic Is to be applied on the interior faze of studs,ceiling joists,and rafters.(This does not replace the requirement for 6-mil black polyethylene(plastic)to be laid over the ground within crawl spaces. PRESCRIPTIVE HEATING SYSTEM SIZING Heating and cooling design loads for the purpose of sizing HVAC systems are required and calculations in accordance with accepted engineering practice,including infiltration and ventilation must be provided when plans are submitted for the building permit. EXCEPTION: Design heat load calculations are not required to be submitted if the heating system installed is equal to or less than 20 Btu/h*ft3. • •City of Anacortes 2001 WSEC&VIAQ Residential Prescriptive Compliance Form Page 6 of 6 if you plan to use this exception please complete the following calculation. Heated floor area 2`too x 20 = ygooO Btu/h*ft(maximum heating appliance rating) Please note that if the heating equipment you actually install exceeds the value calculated in this table,the building inspector may require that you provide design head load calculations prior to field approval. CT 'Y OF ANACORTES BUIDLING DEPARTMENT RESIDENTIAL CHECKLIST (This form is to be completed prior to issuing the building permit) Site Address: ?CO � �` Date 724 0 Contact Person: 1 J v Phone No.: ( t —° °" Assessors No,: Lot: � i2" Block, Addition: (Building Department Checklist fot Completeness) OK NA OK ' NA ❑ ❑ Fire Department Access 0 0 Fire Hydrant Located within 250 feet ❑ ❑ Fire Flow Required 0 0 Shoreline or Wetlands ❑ ❑ Site Plan 0 0 Covenant Approval ❑ 0 Variance Required 0 0 Regulated Slopes ❑ ❑ Plat Facts and Findings Compliance ❑ ❑ Survey in File ❑ ❑ Fill on Site Received and Reviewed by: Date: (Engineering Department Checklist for Completeness) • OK NA OK NA E ❑ Water Extension/Meter ❑ Sewer Extension/Connection ❑ Street Improvements/Sidewalks gj 0 Site Drainage Plan IN 0 Covenant Not to Oppose Future LID Pg 0 Latecomers Agreement r3 0 Street Drainage ® 0 Driveway location,slope,culvert ❑ Storm Drain Fmrnsion ([�/ �s"Received and Reviewed by: � +fie% % Date —24 1u I • 'FURTHER COMMENTS] Zoning: ..I c� Lot Size: J IC.) Coverage Allowed: s � III Actual Coverage: d2 LT c BUILDING INFORMATION FidaI o I 1 LANDSCAPE LEGEND • OWNER Island ,F, I O NORWAY MAPLE 2" CALIPER STRANDBERG CONSTRUCTION INC, Architeds P.O. BOX 319 ACER PLATANOIDES w_ I EUROPEAN WHITE BIRCH 8-10' �' ANACORTES, WA 98221 LLC PHONE 360-293-7431 BETULA PENDULA �� FAX 360-299-8660 909 Seventh Street �� RED JAPANESE MAPLE 4-5' • BUILDING Anacortes, WA 98221 �- ►.� ACER PALMANTUM "ATROPURPOREUM' F OORDEL RE 360-588-0471 FLOOR AREA - 1479 SF MIKE UNDERWOOD a DAVID VIBURNUM 2 GAL. !? • GARAGE AREA 555 SF VIBURNUM DAVIDII E-mail mikeunderwoodOisomedic.com PAUL SCHWULST � ) DWARF RHODODENDRON 2 GAL. • SITE E-mail paulschwulst®isomedia.corrh i `^r LOT 13, F1R CREST DECIDUOUS AZALEA 2 GAL. �I • ZONING PUO URIOPE SPICATOR 'CREEPING ULY'TUURF" • SETBACKS SEE SITE PLAN IOIitAIILWir.: y:� rlijii VINVA MAJOR "BIG PERIWINKLE" • HEIGHT MAX. ALLOWED: 35' PROPOSED: 23' t 6' • PARKING NOTES PARKING SPACES PROVIDED - 2 IN GARAGES DRAWING INDEX A1.1 SITE PLAN TITLE SHEET PROJECT INFO r;' I 20'-0' A p FRONT YARD SETBACK i FOUNDATION DETAILS , 1 . FOUNDATION PLAN 1 _ _ BUILDING CODE FLOOR FRAMING — . _ . _ . _ . — . —. _,. . _ . • _ • _ • _ • — • _ • _ _ . CONCRETE, 93'00 PROPERTY LINE 1 A3.1 MAIN FLOOR PLAN • W'uxWAY '' • OCCUPANCY TYPES LATERAL PLAN R-3 OCCUPANCY I A3.2 UPPER FLOOR PLAN LATERAL PLAN v.'' • RATINGS BASED ON DISTANCE TO PROPERTY LINES (TABLE 5A) NO RATED WALLS OR OPENINGS REQUIRED A4.1 MAIN FLOOR FRAMING PLAN , -� - I LOWER ROOF FRAMING PLAN PROPERTY UNE r -"1 Li L.1 [, I LAW I sy9 ;:, t ° 'RORG{ ,,, SETBACK LINE I • CONSTRUCTION TYPE - TYPE V-N A4.2 UPPER ROOF FRAMING PLAN W" r — �-— —�- - -- �-— -- — —; I • ALLOWABLE BUILDING AREA (TABLE 5B) = UNLIMITED A5.1 BUILDING SECTIONS r I I A5.2 WALL SECTIONS Lill/sr I I I CODES AB.1 BUILDING ELEVATIONS 1 I 1i(e) <, UNIFORM BUILDING CODE - 1997 EDITION A7.1 DETAILS • UNIFORM MECHANICAL CODE - CURRENT EDITION SPI GENERAL NOTES RESIDENCE I UNIFORM PLUMBING CODE - CURRENT EDITION - ( UNIFORM ELECTRICAL CODE - CURRENT EDITION11 WASHINGTONLOCALORDINANCES -STALE ENERGY CURRENT CODEEDI-TIONCURRENT EDITION I 1 I PROPERTY LINE {'; . ; 4 + 1-- , I- - - - — -- - T o• I GENERAL NOTES ,;. CONGRETk I�RlY>rWAY , 1. ALL POTENTIAL CONTRACTORS SHALL THOROUGHLY FAMILIARIZE I• ; r r>, k, GARAGE I C] THEMSELVES WITH JOB CONDITIONS BEFORE BIDDING TO ENSURE THAT THEY �` UNDERSTAND THE SCOPE OF THE WORK. ANY CONDITIONS WHICH ARE NOT i ;, I CLEAR OR ARE DIFFERENT THAN REQUIRED BY CODE SHALL BE BROUGHT 'w,' " ` • TO THE ATTENTION OF THE DESIGNER PRIOR TO BIDDING THE WORK. DO I ' : y BURWNG LINE. - -r' 'I L. J I FPA¶O' NOT SCALE OFF DRAWINGS. NOTIFY THE DESIGNER IMMEDIATELY OF ANY , , S DISCREPANCY IN DIMENSIONS. �z ,, N + I , ,+}ACC 4t J I Cq )' 'J � ROQF 001.410 0'ig " ^- , e 2. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL ' " ' s '*d" , '. ` , i — " : ''';‘ ' NOTES AND TYPICAL DETAILS. r ,; W . ," L �- - -- — — -- 1 '- ( 3. DIMENSIONS SHALL SUPERCEDE SCALE, AND ARE MEASURED FROM EDGE T Y o, < OF STUD. �- -� — .SETBACK L1NE. �� N . — . • - . . — — . . 4. ALL WORK SHALL CONFORM TO THE LATEST APPROVED EDITION OF THE \ 93.00' FOLLOWING STANDARDS: UNIFORM BUILDING CODE UNIFORM MECHANICAL PROPERTY UNE /I / -' CODE UNIFORM ELECTRICAL CODE UNIFORM PLUMBING CODE LOCAL CODES 'I- I AND ORDINANCES. I I s r f- R CREST BLVD `— 42nd COURT STRANDBERG 40 Construction I I INC 1 ' Anacortes, WA j LOT 1 . FIR CREST LOT 13 �� SITE PLAN ryh/ 39 f H2 I • I TITLE SHEET SCALE : lien malealliiii FIR CREST / L SITE PLAN N o z' a B' 36 PROJECT INFO z Westwood Or. _� c 34 W[ < r j • 38 33 30_� 29 26 _ 25 22 21 • W 37 44.0 32 31 28 27 24 23 20 DATE SHEET . �O , FIR clt""#LR kD 5/5/04 / 18 r 17 16 I 'r ty„''; 12 9 8 5 4 1 )) ■ 19 15 T14•• 11 10 7 L6 3 2 (�flT .��.i I .�. ..._..�.. l lii VISIONS �\ /- C MAY 2 0 2004 �II KEYPLAN -- -_a -- 1 __ _ , , til c L i t i � C�rt-s•< ��