--- -- site Wikstrom Residence
<br /> _ _
<br /> • a .
<br /> ..
<br /> - o 0 0 A UNDERWOOD
<br /> - � eg o off _ [ ° 0� 00n 0n A [r� a © oJto W
<br /> ` the'St &ASSOCIATES,LLC
<br /> ail 1 1
<br /> CITY OF ANACORTES 10054thStreet
<br /> in-
<br /> Iiiiiii .--
<br /> anacortes, washington 98221
<br /> "'" PLANNING & BUILDING DEPT: 360.588.0471
<br /> q �, mike underwood, AIA
<br /> I;21 ! 10tri St .- I 1 PERMIT LANS
<br /> tt: APPROVEDF Q ?o
<br /> ` 5 I)- 209lilta - t. icil a MIS* 3
<br /> www.underwoodarchitecture.com
<br /> �I II +� •
<br /> ADDRESS: 1 j 1 10 -ill S"r
<br /> S APPROVED 8Y: /y� yr Is /ZF72o
<br /> ' -� rh-.�t
<br /> t
<br /> SUBJECT TO FIELD INSPECTION. APPROVED PLANS
<br /> L . - SHALL NOT BE ALTERED WITHOUT AUTHORIZATION,
<br /> Z •
<br /> - `' i_ ffi
<br /> - , t -Anacortes•
<br /> FILE COPS,
<br /> Ill:_ - /J .- .
<br /> Architecturalsheet
<br /> List
<br /> 1 : - : . --,1;27i:11-0.:.:\ Nr,U Sheet
<br /> t Number I
<br /> Sheet Name
<br /> r1 ,
<br /> I
<br /> . r ;5 AO.0 Title Sheet
<br /> • A1.1 Site Plan + Landscape Plan
<br /> A2.1 Foundation Plan
<br /> Vicinity
<br /> r1" Map
<br /> IL 1 A3.1 Demo and Floor Plan
<br /> /4 V �l��l I�ty IVIap M.1 Lateral & HVAC Plans
<br /> \ 1/4" = 1'-0" A4.2 Floor Framing Plan & Fence Details
<br /> A4.3 Roof Framing Plan
<br /> A5.1 Building and Wall Sections
<br /> A6.1 Building Elevations
<br /> A6.3 Interior Elevations
<br /> SP1 General Notes
<br /> Grand total: 11
<br /> This Is A Standard List Of Abbreviations Used By This Office. Items
<br /> Listed May Or May Not Be Used On This Set Of Drawings.
<br /> kb. Anchor Bolts �± Ga. Gauge p R. Riser
<br /> AAc. Acoustical V Galv. Galvanized R Rad., R Radius 9878 Registered
<br /> Add. Addition Glu-lam Glue Laminated R.d. Roof Drain ARCHITECT
<br /> Adj. Adjustable/Adjacent GLB Glue Lam Beam Ref. Reference
<br /> A.f.f. Above Finished Floor Gr. Grade Reqd. Required �--
<br /> Michael G. Underwood
<br /> Alt. Alternate GWB Gypsum Wallboard Rm. Room
<br /> State of Washington
<br /> RO Rough Opening
<br /> Bld. Building HB Hose Bib 9/22/21
<br /> B Blk Block H HC Hollow Core
<br /> B.O. By Owner Horiz. Horizontal SC Solid Core
<br /> Btm. Bottom Hr. Hour S Sect. Section Permit Set
<br /> B.U.C. Built Up Column Hdr. Header SF Square Feet
<br /> BWP Braced Wall Panel Shtg. Sheathing General Notes Building Code Energy Code Notes Project Directory Building Information
<br /> Sim. Similar Project name:
<br /> Insul. Insulation Spec. Specification
<br /> cCab. Cabinet Int. Interior Sq. Square 1. All potential contractors shall thoroughly Zoning Category: OT, Old Town This building is governed by the 2015 WSEC,Prescriptive Energy Code,for Owner: Brom and Anne Wikstrom Site Address: 1211 10th Street W i kstro rn
<br /> Cdr. Cedar SS Stainless Steel Small Dwelling Unit. 1.5 Points 2715 W Lynn Place Anacortes,WA 98221
<br /> C.j. Control Joint Jt. Joint familiarize themselves with job conditions before
<br /> Clkg. Caulking J Jst. Joist Std. Standard bidding to ensure that they understand the scope of Occupany Group: R3 Energy Credit Requirements: 3.5 points Seattle,WA 98199 Residence
<br /> C.L. Centerline Stl. Steel the work. These notes aregeneral in nature and are Parcel Number: P55411
<br /> Energy Credits Proposed: 3.5 points
<br /> Stor. Storage intended to set the minimum standards for Construction Type:V-B Architect: Underwood &Associates, LLC
<br /> CMU Concrete Masonry Unit K Kit. Kitchen yP
<br /> SS Storm Sewer 1005 4th Street Legal Description:
<br /> Col. Column construction. Any conditions which are not clear or Efficient Building Envelope 1a:0.5 Energv Credits
<br /> Susp. Suspended Anacortes, WA 98221 LOTS 5 AND 6, BLOCK 78, MAP OF THE CITY OF ANACORTES, SKAGIT Project Address:
<br /> Conc. Concrete L Lay. Lavatory are different than required by code or site conditions Permitted uses: Prescriptive compliance is based on Table R402.1.1 with the
<br /> Constr. Construction Ivl Microlam timber shall be brought to the attention of the designer Single Family Dwelling units following modifications: 360-588-0471 COUNTY, WASHINGTON,AS PER PLAT RECORDED IN VOLUME 2 OF
<br /> Cont. Continuous Is' Timberstrand timber T.TOF Tread
<br /> Top of Footing immediately. The contractor shall verify all Vertical fenestration U=028 PLATS, PAGES 4 THROUGH 7, RECORDS OF SKAGIT COUNTY, 1211 1 0th Street
<br /> T
<br /> TOC Top Of Curb dimensions and conditions on all sheet drawings Lot Size (minimum in zone): Floor R-38 Contractor: Quantum Construction WASHINGTON.
<br /> D. Dryer Mat. Materialand in the field, and notifythe designer of any6,000 sf for Single-Family 12761 Quantum Lane
<br /> Dbl. Double T&G Tongue & Groove 9 9 Y High Efficiency HVAC Equipment 3d: 1.0 Energy Credits
<br /> Anacortes, WA 98221 BuildingAreas:
<br /> Max. Maximum discrepancies before proceeding, 7,500 sf for Duplex
<br /> Thk. Thick P P 9 P
<br /> Df Douglas Fir M.b. Machine Bolt Ductless Split System HeatPumps,Zonal Control:ln homes 360-293-0656 Existing Residence Area: 768 sf
<br /> Dn. Down Mech. Mechanical TOW Top Of ab
<br /> TOW Top Of Wall 2. Specific notes and details shall take precedence Setbacks: where the primary space heating system is zonal electric #QUANTCI166DF Demo of Existing Residence Area :240 sf
<br /> DS Downspout Memb. Membrane heating,a ductless heat pump system shall be installed and Project Year: 2019
<br /> Tv Television over general notes and typical details, Front: 20 feet provide heating to the largestzone of the housing unit.To
<br /> C Dtl. Detail Min. Minimum Issue Date: 12/20/19
<br /> E DW Dishwasher Washer Mir. Mirror Typ. Typical Side Interior Lot: 5 feet quality to claim this credit,the building permit drawings shall Codes Existing Garage Area: 527 sf
<br /> Mtl. Metal 3. Dimensions shall supersede scale, and are Rear: 20 feet specify the option being selected and shall specify the Demo of Garage Area: 527 sf
<br /> I.
<br /> 0 UNO Unless Noted Otherwise measured from edge of stud. Where the rear yard abuts a platted alley, a heating equipment type and the minimum equipment 1. building 2015 IRC Revisions
<br /> EEa. Each
<br /> EL Elevation detached accessory structure,or that portion of the efficiency 2. mechanical 2015 IRC Addition to Residence: 1,284 sf
<br /> Elec. Electrical (n) New Var. Varies No. Date Description
<br /> N NIC Not In Contract `I 4. All work shall conform to the latest approved primary structure used as an accessory structure, may Efficient Water Heating Category 5a 0.5 Energy Credits 3. plumbing: 2015 UPC
<br /> b Elev. Elevator NTS Not To Scale V VCT Vinyl Composition Tile editions of the standards listed in "codes", be built in a rear yard up to the alley property line, Total Residential Area: 1,812 sf
<br /> Vert. Vertical residential bathroom lavitory sink faucet: 1.0 gal/min 4. energy and ventilation: 2015 WSEC
<br /> EQ Equal provided that it is set back a minimum of three feet
<br /> Vest. Vestibule residential kitchen faucet. 1.75 gal/min Equip. Equipment OC On Center 5. Provide 6" high temporary and permanent from any side property line, and is no larger than oneSite Area: 6,000 sf
<br /> (e) Existing
<br /> OFCI Owner Furnish I W Washer address numbers on site that are viewable from the thousand square feet and no more than sixteen feet in residential shower heads: 1.75 gallmin
<br /> g Q q Project Description
<br /> Exist. Existing Contractor Installed W WI With street. height. Efficient Water Heating Category 5c: 1.5 Enemy Credits Lot Coverage by Building: 2,070 sf 16,000 sf= 34.5% <35% ok!!
<br /> , Ext. Exterior Opng. Opening WC Water Closet ° Water heating system shall include one of the following:Gas, Remodel and partial demolition of existing °
<br /> OSB Oriented Strand Board WD Wood 6. Confirm location of all utilities within easements Lot Coverage (maximum allowed): 35/o or oil water heater with a minimum EF of 0.91 Lot Coverage by Impervious Surfaces: 3,806 sf/6,000 sf= 63.4/o
<br /> FD Floor Drain propane residence with addition.
<br /> N F Fin. Finish W/O Without and on site prior to excavation work,
<br /> o P-lam Plastic Laminate WP Water Proof Allowable Height: 25 feet Landscaping: 1,200 sf=20%
<br /> F.f. Finished Floor P Ply Plywood WWF Welded Wire Fabric Proposed: 19'-9"
<br /> r4 FS Finished Slab PR Pair
<br /> FLR Floor PSL Parallam timber
<br /> End. Foundation Parking: Two off-street parking spaces per dwelling unit.
<br /> F.o.c. Face Of Concrete
<br /> PT Pressure Treated
<br /> Title Sheet
<br /> B Fo.s. Face Of Studs
<br /> o Ft. Foot Or Feet
<br /> Fur. Furring Project Info r n n -�
<br /> m F.e. Are Extinguisher
<br /> > 1J 1/4" = 1'-0" t I,I 1'I co
<br /> iii
<br /> 11 DEC 232019IL pjj . 0
<br /> it,
<br /> ^ITY OF ANAGORTES
<br /> U 12/20/2019 3:49:07 PM
<br />
|